Determination of L-Dopa by Spectrofluorimetry Using Co-fluorescence Enhancer (보조 형광증가제를 이용한 L-Dopa의 형광분광법적 정량)

  • Lee, Sang Hak;Ahn, Jung Mi
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.541-546
    • /
    • 2000
  • Methods to determine L-dopa(L-3,4-dihydroxyphenylalanine) in aqueous solution by spectrofluorimetry based upon the ligand sensitized luminescence of Tb(III) ion L-dopa complex have been studied. Tb(III) ion and Lu(III) ion were used as ligand sensitized fluorescencer and co-fluorescence enhancer, respectively. The effects of excitation wavelength, pH, concentration of Tb(III) ion, concentration of Lu(III) ion and emission wavelength on the fluorescence intensity were investigated. The fluorescence intensity of the Tb(III) ion L-dopa complex was further increased with addition of Lu(III) ion. The calibration curve for L-dopa was linear over the range from 5.0 ${\times}$ $10^{-7}$ M to 1.0${\times}$ $10^{-4}$ M and the detection limit was 4.0 ${\times}$ $10^{-8}$ M under the optimal experimental conditions of 300 nm, 8.0, 1.0 ${\times}$ $10^{-4}$ M and 545 nm for excitation wavelength, pH, concentration of Tb(III) ion and emission wavelength, respectively. When Lu(III) ion was added to Tb(Ⅲ) ion L-dopa complex, the concentration range of linear response and detection limit were 1.0${\times}$$10^{-8}$ M to 2.0 ${\times}$ $10^{-4}$ M and 1.0 ${\times}$ $10^{-9}$ M, respectively under the optimal experimental conditions of 300 nm, 8.5, 1.0 ${\times}$ $10^{-5}$ M, 1.0 ${\times}$ $10^{-5}$ M, 545 nm for excitation wavelength, pH, concentration of Tb(III) ion, concentration of Lu(III) ion and emission wavelength, respectively.

  • PDF

Development of a Pacemaker with a Ventricular Assist Device for End-Stage Heart Failure Patients (말기 심질환 환자를 위한 심실보조장치용 심박조율기의 개발)

  • Kim, Yoo-Seok;Park, Sung-Min;Choi, Seong-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1205-1211
    • /
    • 2011
  • In this paper, we developed a pacemaker that can increase the efficacy of a left ventricular assist device (LVAD) and increase the survival rate for patients suffering end-stage heart failure. Because LVAD patients can experience arrhythmia, the pacemaker incorporated into the LVAD has the important role of sustaining sufficient blood circulation during arrhythmia. The electrode of the pacemaker is located at the apex of the left ventricle, where the VAD's inlet cannula is connected. This is efficient placement, in that the electrode can transmit electrical stimulation directly to the Purkinje fibers of the myocardium. The pacemaker can change the stimulation rate from 0 bpm to 191.4 bpm when a button is pressed on the external control module, and the pacemaker normally stimulates the heart at 60 bpm with 0.25 J of energy. We performed animal experiments to evaluate the performance and reliability of the combination of the LVAD and pacemaker. At pacemaker stimulation rates of 86.4 bpm, 100.2 bpm, 126.6 bpm, we recorded the ECGs, aortic pressures, and flow rates to analyze the heart loads.

A Study on the Status of Practical Application of Oral Hygiene Devices :with labor of the D heavy industries (D중공업 근로자의 구강위생용품 사용실태 조사)

  • Park, Hong-Ryurn
    • Journal of dental hygiene science
    • /
    • v.6 no.2
    • /
    • pp.93-99
    • /
    • 2006
  • This study was carried out to investigate practical application status of oral hygiene devices through making a survey of labor of the D industrial company-about carefully curing oral disease in home, the status of practical application of tooth brush, the status of practical application of fluoridated toothpaste, status of practical application of auxiliary oral hygiene devices, a motive use or unuse of auxiliary oral hygiene devices. 1. In home, carefully curing oral disease is dental caries(62.4%). 2. Status of practical application toothbrush showed the highest user ratio of mideum size(79.6%). 3. Showed the highest user ratio of horizontal plane toothbrush(73.5%). 4. Answerd don't take a prudent attitued in choice of fluoridated toothpaste(73.5%). 5. In the status of reconition of oral hygiene devices, showed the highest user ratio of eletric toothbrush(77.0%). 6. In the status of reconition of auxiliary oral hygiene devices, showed the highest user ratio of wooden wedge stimulator(89.4%)and gargle liquid(84.5%). In using of oral hygiene devices, showed the highest user ratio of electric toothbrush(13.3%), toohbrush for periodontal patients(2.7%). In using of auxiliary, wooden wedge stimulator (58.4%)and gargle liquid(41.2%). In effect using of oral hygiene devices showed the highest user ratio of denture brush(50.0%)and eletric toothbrush(43.3%), in effect using of auxiliary oral hygiene devices showed the highest user ratio of water pick(80.0%) and dental floss(75.8%). 6. A motive of the use auxiliary oral hygiene device is choice by oneself through TV, advertisement, public information(57.6%), and the reason-they don't use of auxiliary oral hygiene devicebecause of they don't know proper to them the kind of auxiliary oral hygiene device.

  • PDF

Quality Tests for the Knee-Orthosis Velcro and Locking System (무릎보조기 벨크로 및 잠금장치에 대한 품질시험 연구)

  • Jung, Se-Wook;Seo, Won-San;Cho, KiHun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.275-283
    • /
    • 2016
  • In this study, three knee-orthoses (dial lock type, medium size, right side) were used for a quality level test (static bending test and solidity test of the locking system) of the knee-orthosis locking system. In the static bending test, a smaller maximum load was observed in samples A and C compared to the reference standard value (KS P 8408 standard value: 1000 N, sample A: 865 N, sample C: 833 N). In addition, in the solidity test of the locking system, a smaller maximum load was observed in the all samples compared to the referenced standard value (KS P 8411 standard value: 200 N, sample A: 41 N, sample B: 97 N, sample C: 54 N). Korean industrial standards for knee-orthoses and systematic test methods are lacking. Therefore, a systematic management plan for knee-orthoses is required. The result of the current study showed that a systematic management plan for the knee-orthosis locking system is required. In particular, the development of a quantitative and objective test method is needed. The findings of the current study may be useful for monitoring the quality of the knee-orthosis locking system and may provide foundational information for the development of a quantitative and objective test method.

Development of Ankle Power Assistive Robot using Pneumatic Muscle (공압근육을 사용한 발목근력보조로봇의 개발)

  • Kim, Chang-Soon;Kim, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.771-782
    • /
    • 2017
  • This paper describes the development of a wearable robot to assist ankle power for the elderly. Previously developed wearable robots have generally used motors and gears to assist muscle power during walking. However, the combination of motor and reduction gear is heavy and has limitations on the simultaneous control of stiffness and torque due to the friction of the gear reducer unlike human muscles. Therefore, in this study, Mckibben pneumatic muscle, which is lighter, safer, and more powerful than an electric motor with gear, was used to assist ankle joint. Antagonistic actuation using a pair of pneumatic muscles assisted the power of the soleus muscles and tibialis anterior muscles used for the pitching motion of the ankle joint, and the model parameters of the antagonistic actuator were experimentally derived using a muscle test platform. To recognize the wearer's walking intention, foot load and ankle torque were calculated by measuring the pressure and the center of pressure of the foot using force and linear displacement sensors, and the stiffness and the torque of the pneumatic muscle joint were then controlled by the calculated ankle torque and foot load. Finally, the performance of the developed ankle power assistive robot was experimentally verified by measuring EMG signals during walking experiments on a treadmill.

Comparison of X-ray Image Quality Between Multi-Function Device(MFD) and Weight Bearing Platforms(WBPs) (다기능 보조기구와 체중부하검사 보조기구의 X선 화질 비교)

  • Gil, Jong-Won;Lee, Kwang-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.605-611
    • /
    • 2019
  • The purpose of this study is to manufacture a multi-function device (MFD) which can be applied to various types of weight-bearing view of the lower leg, and to compare the results with the images from the existing weight-bearing platforms (WBPs), thereby suggesting a clinical utilization. The MFD was manufactured, by considering the minimum adjustable heights of the platform for weight-bearing foot/ankle, platform for hindfoot alignment view, and X-ray tube of the X-ray device. A foot/ankle phantom was used to take the images of weight-bearing lateral foot in MFD and WBPs to compare the resolutions of the X-ray images using a quick modulation transfer function (MTF) program. Between both the images taken from the MFD and WBPs, there was no statistically significant difference found in the mean cycles per pixel (C/P) and the lines per image height (LPH) of the 50%-Contrast Spatial Frequency (MTF50), and 10-90% of Maximum Energy Rise Distance (10-90%), where p>0.05. The MFD is suggested for its clinical trial as a useful positioning device that can secure the patient's safety and manifoldly perform various inspections. Also, the recommendation of the positioning device as a policy can activate dedicated manufacturers, while also improving the quality of medical services.

A Secure and Lightweight Authentication Scheme for Ambient Assisted Living Systems (전천 후 생활보조 시스템을 위한 안전하고 경량화 된 인증기법)

  • Yi, Myung-Kyu;Choi, Hyunchul;Whangbo, Taeg-Keun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.77-83
    • /
    • 2019
  • With the increase in population, the number of such senior citizens is increasing day by day. These senior citizens have a variety of care needs, but there are not enough health workers to look after them. Ambient Assisted Living (AAL) aims at ensuring the safety and health quality of the older adults and extending the number of years the senior citizens can live independently in an environment of their own preference. AAL provides a system comprising of smart devices, medical sensors, wireless networks, computer and software applications for healthcare monitoring. AAL can be used for various purposes like preventing, curing, and improving wellness and health conditions of older adults. While information security and privacy are critical to providing assurance that users of AAL systems are protected, few studies take into account this feature. In this paper, we propose a secure and lightweight authentication scheme for the AAL systems. The proposed authentication scheme not only supports several important security requirements needed by the AAL systems, but can also withstand various types of attacks. Also, the security analysis results are presented to show the proposed authentication scheme is more secure and efficient rather than existing authentication schemes.

Research on Safety and Quality Regulatory Policy for Assistive Products (보조기기 안전·품질관리 방안 연구)

  • Kim, Hye-Won;Kim, Dong-A;Seo, Won-San;Kim, Jang-Hwan;Ko, Myeong Han;Son, Byung-Chang;Yi, JinBok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.805-813
    • /
    • 2018
  • The research was conducted with the purpose of providing effective safety and quality control system for assistive products for handicapped those are used extensively. Assistive products couldn't be classified independently due to collision with the act of medical device and lack in legal basis. The issues about safety and quality have been solved by other legal frames on a case by case basis. We couldn't find any abroad case of independent safety and quality control policy. For the practical solution, this article suggested hybrid classification system mixed with existing policies. Each classified branches are allocated to the appropriate policy of safety and quality control so those are ease of understanding and prospect. And also a delicacy process was suggested not to leave off any assistive products. Through these suggests of the improvement it is expected that blind areas of safety and quality control for assistive products for handicapped could be solved and identity of assistive products could be established to provide product safety for handicapped and boost relevant industries.

Usage intention and recognition of necessary functions for ICT-based care devices in older adults living alone (독거노인의 ICT 기반 돌봄 보조 기기 사용의향 및 필요 기능 인식에 대한 기술적 연구)

  • Paek, Min-So;Shin, Junseob;Shin, Yu-Seon
    • 한국노년학
    • /
    • v.41 no.1
    • /
    • pp.25-48
    • /
    • 2021
  • This study intended to examine the willingness to use as well as necessary functions for ICT-based care assistance devices in older adults living alone. A total of 241 older adults living alone from a city participated in the study. Study results show that many older adults living alone are willing to use ICT-based care assistance devices at their home and the functions of care assistance devices that they perceived as necessary were diverse. In addition, there were differences in perception of functional necessity by socio-demographics and medical and functional characteristics of older adults living alone. In particular, there were significant differences in the functions perceived as necessary according to the presence of osteoporosis, depression, insomnia, and limitations in daily activities. Our study findings suggest that the functions of ICT-based care devices should be developed in various ways in order to help healthy aging in place. Findings also imply that it is necessary to provide individualized services and customized care assistance devices according to individual's medical and functional characteristics and needs.

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.