• Title/Summary/Keyword: 보조선

Search Result 327, Processing Time 0.027 seconds

Enhancing Work Trade Image Classification Performance Using a Work Dependency Graph (공정의 선후행관계를 이용한 공종 이미지 분류 성능 향상)

  • Jeong, Sangwon;Jeong, Kichang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.1
    • /
    • pp.106-115
    • /
    • 2021
  • Classifying work trades using images can serve an important role in a multitude of advanced applications in construction management and automated progress monitoring. However, images obtained from work sites may not always be clean. Defective images can damage an image classifier's accuracy which gives rise to a needs for a method to enhance a work trade image classifier's performance. We propose a method that uses work dependency information to aid image classifiers. We show that using work dependency can enhance the classifier's performance, especially when a base classifier is not so great in doing its job.

Scenario and Network Performance Evaluation for A Do Not Pass Warning Service Based on Vehicle-to-Vehicle Communications (차량 간 통신 기반 추월보조 서비스를 위한 시나리오 및 네트워크 성능 평가)

  • Seo, Hyun-Soo;Jung, Jin-Su;Lee, Sang-Sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.3
    • /
    • pp.227-232
    • /
    • 2013
  • Due to the development of ITS technology, various services related to transportation under vehicular environments have been provided. Especially, as wireless communication technology, WAVE has been established as a standard for vehicle-to-vehicle communications. WAVE has fast connection and excellent mobility characteristics. A VSC-A project is conducting by global automotive OEMs in USDOT. This project introduces the advanced safety services with vehicle-to-vehicle communications. In this paper, we presented the scenario of a do not pass warning service, which prevents an accident during overtaking activity by using vehicle-to-vehicle communications. In addition, we analyzed network performance under WAVE. In conclusion, we introduced the simulation results. Finally, we summarized the communication range and delay values for consideration factors for a overtaking model.

Load transfer test of circular anchorage system according to ETAG 013 (ETAG 013 규정에 따른 원형 정착구의 하중전달실험)

  • Kim, Bum-Joon;Kim, Hyun-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.167-175
    • /
    • 2018
  • Load transfer experiments have been carried out to evaluate the performance of the anchorage and it has been stated that the specimens were manufactured and tested according to ETAG 013. On the other hand, the amount of spiral reinforcement and auxiliary reinforcement exceeded the amount specified in ETAG 013. In this study, the load transfer test method and the criteria specified in ETAG 013 were considered and the PT anchorage system was applied to manufacture specimens with high strength concrete and a high tensile prestressing strand. A load transfer test according to ETAG 013 was performed to evaluate the performance of the circular anchorage. As a result, it was confirmed that ETAG 013 is a very strict specification that does not satisfy the performance of an anchorage unless the specimens of an appropriate size and spiral reinforcement are used. To assess the stability of the specimens, increasing the size of the specimen by 15%, rather than increasing the amount of auxiliary reinforcement, is considered to be the correct method in accordance with ETAG 013.

Design and Implementation of a Linearizer Using the Feedforward Loop without Delay Lines (지연 선로가 없는 Feedforward Loop를 이용한 선형화기의 설계 및 제작)

  • 정승환;조경준;김완종;안창엽;김종헌
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.116-123
    • /
    • 2000
  • This paper presents a linearizer using the feedforward loop which can be applied to PCS base-station applications. This linearizer used a IM amplifier and an auxiliary amplifier in order to remove delay lines used in the predistortor using the feedforward technique. The delay line in error loop is changed by the main power amplifier(PA) and the error amplifier is utilized to amplify the error signal which fed to the output of main amplifier. The linearizer was simulated by HP ADS ver 1.1 and fabricated on GML 1000 with thickness of 0.8 mm and dielectric constant of 3.2. Two-tone signals at 1.85 GHz and 1.851 GHz with -7dBm/tone from synthesizers are injected into the main PA. The main PA with a 27 dB gain and a $P_{1dB}$ of 29 dBm(two-tone) was utilized. The reduction of intermodulation distortion (IMD) is around 17 dB.

  • PDF

Application for Workout and Diet Assistant using Image Processing and Machine Learning Skills (영상처리 및 머신러닝 기술을 이용하는 운동 및 식단 보조 애플리케이션)

  • Chi-Ho Lee;Dong-Hyun Kim;Seung-Ho Choi;In-Woong Hwang;Kyung-Sook Han
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.83-88
    • /
    • 2023
  • In this paper, we developed a workout and diet assistance application to meet the growing demand for workout and dietary support services due to the increase in the home training population. The application analyzes the user's workout posture in real-time through the camera and guides the correct posture using guiding lines and voice feedback. It also classifies the foods included in the captured photos, estimates the amount of each food, and calculates and provides nutritional information such as calories. Nutritional information calculations are executed on the server, which then transmits the results back to the application. Once received, this data is presented visually to the user. Additionally, workout results and nutritional information are saved and organized by date for users to review.

A study on the characteristics of tunnel deformation and support system according to tunnel portal reinforcement method (터널 갱구부 보강방법에 따른 터널 변형 및 지보재 응력특성에 관한 연구)

  • Moon, Kyoung-Sun;Seo, Yoon-Sic;Kang, Si-On;Kim, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.3
    • /
    • pp.625-639
    • /
    • 2018
  • This study is about the reinforcing type of reinforcement method which is reinforced in tunnel portal of tunnel with bad ground condition. Generally, it is known that the horizontal reinforcement method is more effective than the conventional reinforcement method. However, as a limitation of the tunnel construction technology, it is being constructed by the superposition reinforcement method. In recent years, high-strength large-diameter steel pipes and horizontally oriented longitudes (L = 30.0~50.0 m) construction technology have been developed. Therefore, it is required to study reinforcement method of tunnel portal reinforcement method. Therefore, 3-D numerical analysis (Midas GTS NX 3D) was performed by setting the reinforcement method (No reinforcement type, overlap reinforcement type and horizontal reinforcement type) and ground condition as parameters. As a result, it was considered that the reinforcement effect was the largest as the horizontal reinforcement type of the reinforcement method was the smallest in the displacement and the support material stress. Based on the results of the numerical analysis, horizontal steel pipe grouting was applied to the actual tunnel site. The displacement of the tunnel portal and the stress of the support material occurred within the allowable values and were considered to ensure sufficient stability.

A Study on the selection and noise test of elelctronic sensor for Vacuum Circuit Breaker (진공차단기용 전자식 센서의 선정 및 노이즈 시험에 관한 연구)

  • Lee, Ki Seon;Park, Jung Cheul;Chu, Soon Nam
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2503-2508
    • /
    • 2014
  • This study is about the selection and noise test of electronic sensor which is preceded by electric Operating Cell(EOC) development using electronic sensor technology to solve the structural weakness of Mechanism Operated Cell(MOC) in VCB, and has a final target in product development minimizing contact malfunction of the chattering or rebounce states caused by existing MOC. In this test results, when opening and closing VCB, rising velocity of surge voltage in opening time was measured 4.2 times faster than closing time and noise decibel value was measured respectively 120dB and 110dB. When supplying 60kV power frequency overvoltage, we found that sensor output graph in VCB opening and closing times operated stably without distortion. When supplying 150kV $1.2{\times}50{\mu}s$ impulse frequency voltage, we found that voltage graph of output contact in sensor opening and closing sides maintained a normal condition without distortion, and when supplying 2500A current, we found that tested result of electric field noise operated stably without distortion.

A Study on an Impedance Matching Technique for Rail Power Line Communication (레일 전력선통신을 위한 임피던스 정합방안 연구)

  • Seo, Ill-Kwon;Ahn, Seung-Ho;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.202-207
    • /
    • 2016
  • An auxiliary real-time train communications system among drivers, train-traffic controllers and field workers is necessary to share hazard information (i.e. rockfall detection, track maintenance) in low visibility zones (long tunnels and steep curved track). To develop the appropriate communication system, this paper proposes a new way of power line communication using the rail track (Rail - PLC), which has little noise and distortion of attenuation. Therefore, it is important to measure the impedance of the rail and to apply an impedance matching technique to increase the transmission characteristic of the Rail - PLC. This study would evaluate the reflection and the transmission characteristics of the rail using a network analyzer and an impedance matching transformer. The suitable impedance matching ratio was 1:3.28 from the result of back-to-back testing. The results confirmed that the transformer can improve the performance of the transmission signal in Rail - PLC using an impedance matching technique.

Effects of Ozone Treatment and Gamma Irradiation on the Quality Properties of Dried-Spirullina and Dried-Sea Tangle Powders (오존처리와 감마선 조사가 스피루리나와 다시마 분말의 품질특성에 미치는 영향)

  • Byun, Myung-Woo;Yook, Hong-Sun;Kwon, Oh-Jin;Jo, Sung-Kee;Lee, Sung-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.764-770
    • /
    • 1997
  • For the purpose of improving hygienic quality of dried-spirullina and dried-sea tangle powders as raw materials of health food, the comparative effects of ozone treatment and gamma irradiation on the microbial and physicochemical properties were investigated. Gamma irradiation at 7.5 kGy resulted in sterilization of total aerobic bacteria, coliforms and molds below detective levels $(<10^{1}\;CFU/g\;sample)$, while ozone treatment for 8 hr up to 18 ppm could not sufficiently eliminate the microorganisms of the samples. Physicochemical properties including compositions of fatty acid and amino acid, minerals, pH and natural pigments were not changed by gamma irradaition up to 10 kGy, whereas, ozone treatment caused changes in pH, TBA value, natural pigments and fatty acid compositions. Especially, ozone treatment markedly decreased unsaturated fatty acid of the samples.

  • PDF

The Relationship Between Serum Prostate Specific Antigen and Prostate Volume of Measured by Transrectal Ultrasonography (혈청 전립선특이항원과 경직장초음파로 측정된 전립선 용적과의 상관관계)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.239-243
    • /
    • 2010
  • Even though clinical use DRE, PSA and TRUS for screening while diagnosing prostate cancer early, however, we cannot achieve to diagnose it accurately by one method. Thus, mutual supplements are strongly required in diagnosis. It means that we should identify relationship between prostate volume and serum PSA under different ages for better diagnosis. The subjects(405 men) visited the department of diagnostic radiology in a general university hospital from January 2008 to December 2008, who was going to take the prostatic evaluation by TRUS. 13 men, who did definite diagnosis of prostate cancer before through biopsy, were excluded in this study. All data were expressed as mean and standard deviations by using SPSS 14.0 package programs and were analyzed by using one-way ANOVA to evaluate the effect of different ages. And Scheffe Post hoc comparison is accomplished in order to make significant difference in prostate volume, PSA and PSAD according to ages. Pearson correlation was used for ages, prostate volume, PSA and PSAD. According to examination, the subjects' prostate volume and serum PSA level increase as person's age. We can see significant difference between group over 70 years and group from 40 and 50 years. Moreover, age, prostate volume and serum PSA have significant positive correlation. Even though we can get variations in serum PSA level by changing prostate volume according to ages, it is worthwhile to mention that more strong association for prostate volume is observed than ages in elevation of serum PSA. Therefore, it is strongly recommended to consider prostate volume weightly when it comes to evaluate for men with elevated PSA level. Finally, TRUS is an excellent extra equipment to diagnose prostate cancer because it can contribute to early diagnose and pertinent treatment of prostate cancer.