A Experimental Investigation on the PD Characteristics depending on the various Artificial Voids In Epoxy Insulator (에폭시 절연체의 보이드 크기에 따른 부분방전 특성연구)

  • Choi, C.K.;Lee, J.S.;Kim, J,T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1853-1855
    • /
    • 2000
  • An experimental investigation has been performed in order to understand the $\Phi$-q-n characteristics related to the PD taking place from the various size of artificial defects inserted in epoxy insulation. In this purpose, PD has been detected simultaneously by two different methods such as commercialized PD detector(TE571) and our detection system using self designed CT type sensor. Under the presence of void in epoxy insulation, PD has been initiated at the voltages between 16kV and 20kV which are much lower than the dielectric strength of epoxy insulation (130kV/mm$\sim$l50kV/mm). And also it is revealed that $\Phi$-q-n characteristics have been observed to be dependent upon the size of the artificial defects. Throughout this work, the on site applicability of the self designed Sensor has also been proved by comparing the results with those from the commercialized PD detector. And more one, considerable basic data regarding the insulation, diagnosis could be provided to understand the presence of the voids possibly inserted into the epoxy insulation system of the power apparatus.

  • PDF

The Effects of Two - Phase Swirling Flow on Void Distribution and Pressure Drop in a Vertical Tube (수직관에서 2상선회유동이 보이드분포와 압력강하에 미치는 영향)

  • Kim, I.S.;Son, B.J.;Shin, H.D.;Kwack, K.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.190-201
    • /
    • 1989
  • This experimental investigation has been conducted to determine the effects of swirling angle and flow patterns on distributions of void fraction, bubble velocity and two-phase pressure drop in a vertical straight tube. Swirling angles of $0^{\circ}$ (non swirling), $30^{\circ}$, and $45^{\circ}$ were tested with air-water two components over a range of superficial air velocities. A transparent lucite tube of 38mm in internal diameter was used for the test section. The void fraction and bubble velocities were measured by means of a optical fiber probe at the upper part of the swirler in the test section. Pressure drops which seem to be closely related with flow patterns and swirling angle were measured by a differential pressure transducer. It is shown that the probability density functions of pressure drop demonstrate peculiar features for both swirling angles and flow patterns, whereas the distributions of void fraction and bubble velocities are parabolic and flat shape in the vicinity of tube center, respectively except bubbly flow in any swirling angle cases, and the void fraction increases with increasing swirling angle around the center of tube.

  • PDF

Eliminating Voids in Direct Bonded Si/Si3N4‖SiO2/Si Wafer Pairs Using a Fast Linear Annealing (직접접합 실리콘/실리콘질화막//실리콘산화막/실리콘 기판쌍의 선형가열에 의한 보이드 결함 제거)

  • Jung Youngsoon;Song Ohsung;Kim Dugjoong;Joo Youngcheol
    • Korean Journal of Materials Research
    • /
    • v.14 no.5
    • /
    • pp.315-321
    • /
    • 2004
  • The void evolution in direct bonding process of $Si/Si_3$$N_4$$SiO_2$/Si silicon wafer pairs has been investigated with an infrared camera. The voids that formed in the premating process grew in the conventional furnace annealing process at a temperature of $600^{\circ}C$. The voids are never shrunken even with the additional annealing process at the higher temperatures. We observed that the voids became smaller and disappeared with sequential scanning by our newly proposed fast linear annealing(FLA). FLA irradiates the focused line-shape halogen light on the surface while wafer moves from one edge to the other. We also propose the void shrinking mechanism in FLA with the finite differential method (FDM). Our results imply that we may eliminate the voids and enhance the yield for the direct bonding of wafer pairs by employing FLA.

A Study on the Diagnosis of Treeing Breakdown and Fractal Characteristics Using the Method of Acoustic Enission (음향방출 계측법을 이용한 프랙탈 특성과 트리잉 파괴진단에 관한 연구)

  • 김성홍;심종탁;김재환
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.50-56
    • /
    • 1997
  • As the purpose of the breakdown prediction of three degradation of insulating materials caused by partial discharge occurring at various defects in the polymer insulator itself and at the interfaces between electrodes and the insulating materials. Treeing due to partial discharge os one of the main causes of breakdown of the insulating materials. Recently, the necessity of establishing the way to diagnoses the aging of insulation materials and to predict of insulation breakdown become improtant. The purpose of our work are to use acoustic emission System and fractal dimension and to investigated the treeing phenomena in polymeric insulation under appliec AC voltage 11[kV] with an artificial needleshaped void(1.5[mm]) using the above system.

  • PDF

Partial Discharge Characteristics of XLPE According to Electrode Shape and Void (전극형상 및 보이드에 따른 XLPE의 부분방전 특성)

  • Shin, Jong-Yeol;Kim, Guin-sik;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.50-57
    • /
    • 2016
  • Transmission equipment is mainly used for the XLPE (cross-linked polyethylene) insulation cable for ultra high voltage power to minimize power loss. The experiment examined the partial discharge characteristics according to the insertion of the bar electrode and needle electrode into the XLPE specimen and the air voids. XLPE insulation cable manufactured by T. company and tungsten electrode material by K. company were used for specimens, by adhering conductive tape on the semi-conductive material of the lower electrode of XLPE specimen with the dimension of $16{\times}40{\times}30$ [mm] was used as negative electrode. In order to investigate the PD with ${\phi}$-q-n of XLPE specimen according to the electrode shape and the size of air voids. we examined the PD by varying the voltage after applying voltage of 3~20 kV on the electrode. Therefore, it was confirmed from the result of PD characteristics of specimen that the larger the air void than the gap between electrode (+) and electrode(-), the larger effect on the discharge when the bar electrode and needle electrode inserted into XLPE, and the closer the distance between the insulation and the needle electrode, the faster insulation breakdown.

A Study on the Subtraction Method and Characteristics as Design Organization found in the Architecture of Aires Mateus (아이레스 마테우스 건축에 나타난 디자인 조직체로서의 서브 트랙션 방법과 특성에 관한 연구)

  • Kim, Jong-Jin
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.2
    • /
    • pp.3-12
    • /
    • 2016
  • Aires Mateus Architects is one of the most well-known Portuguese architects after $\acute{A}lvaro$ Siza and Eduardo Souto de Moura. The studio shows clear design methods in which the relationship between solid mass and void space are creatively inter-connected. Subtractive transformation of form is the fundamental aspect of this relationship. Most of Aires Mateus' projects were designed based on the subtractive method. Although subtraction can be seen as architectural formal presentation, in Aires Mateus' cases, there are deeper logics, strategies, and meanings. Not only to create a form, subtractive method has been flexibly used to organize and compose different programs and spatial atmosphere. To examine this hidden dimension of Aires Mateus' unique design process, 5 case projects were selected and analyzed in detail based on program, light & visual-perception, and site's placeness. From the case study results, it is found that there are much deeper role of subtraction: relationship between solid-void are constantly changing to generate serviced and servant spaces, there are central spaces that are contrast against the complexity of exterior forms, aiming to build an archetypal form that transcends ever-changing time, ambivalent balance between universality and peculiarity in the genealogy of contemporary architecture. The study concluded that the unique characteristics of subtraction method as design organization have various possibilities that can apply on other architectural and interior projects which would have similar ideas and circumstances.

Influence of Partial Discharge Properties due to Void in Cable Joint Parts (케이블 접속재 부분방전 특성에 미치는 보이드의 영향)

  • 신종열;홍진웅
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.69-74
    • /
    • 2003
  • To investigate the partial discharge and electric field distribution in cable joint parts, we measured the partial discharge and electric field in specimen. The specimens which cross-linked polyethylene(XLPE) and ethylene propylene diene ethylene(EPDM) are used to insulating material for underground cable md cable jointing parts. The polymers are used to insulating material in switchgear which is a kind of transformer equipment and in ultra-high voltage cable. Its using is increasing gradually, the electrical insulation properties are not only excellent but also mechanical property is excellent. And because it is possible to be made void of several type in insulator while it is produced, which the electrical field distribution is changed by void, it has a critical influence to insulator performance. The underground cable is connecting by the jointing material, insulating breakdown and the electric ageing which are caused by several mixing impurity and the damage of cable insulator layer, which reduced the life of cable while intermediate joint kit is connected. Therefore, the computer simulation is used to estimating insulator performance, XLPE is used to the insulating material of ultra-high voltage cable and EPDM is used to insulator layer in joint material kit, and which are produced as specimen. And it is analyzed the electric field concentrating distribution and partial discharge by modeling of computer simulation in void and cable joint kit.

A Study on Feature Extraction of Partial Discharge Type Using Wavelet Transform (웨이블렛변환을 이용한 부분방전 종류의 특징추출에 관한 연구)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.6 no.1
    • /
    • pp.65-70
    • /
    • 2003
  • In this papers, we proposed the new method in order to diagnosis partial discharge type of transformers. For wavelet transform, Daubechie's filter is used,, we can obtain wavelet coefficients which is used to extract featrue of statistical parameters(maximum value, average value, dispersion, skewness, kurtosis) about high frequency current signal per 3-electrode type(needle-plane electrode, IEC electrode and Void electrode). Also, these coefficients are used to identify signal of internal partial discharge in transformer. As a result, from compare of high frequency current signal amplitude and average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. Otherwise, in case of skewness and kurtosis, we are obtained results of Void electrode> IEC electrode> Needle-Plane electrode. As improved method in order to diagnosis partial discharge type of transformers, we use neural network.

  • PDF

Electric Field Distribution of XLPE due to Position of Void (보이드 위치에 따른 XLPE 전계분포)

  • Park, Hyoung-Jun;Kim, G.S.;Shin, H.T.;Lee, J.P.;Kim, G.Y.;Lee, S.W.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.220-223
    • /
    • 2003
  • This paper is aimed at determining the e-field distribution by apply voltage of air void, which can be generate air void in the XLPE cable for ultra high voltage. E-field distribution had an effect in XLPE due to the type and position of void, compared and studied. This method of analysis is based on the quasi-static electromagnetic 3D simulation program by boundary element method (BEM): Applied AC 3[kV], discretization of 2000 elements, 4 angular periodicity, The result of experiment indicate that E-field distribution appeared the highest levels on the void position of electrode 2[nm] outer boundary and shape of the smallest inner angle in the void. This will serve to explain the XLPE cable degradation studied of possible, connected cable variation of position and shape of void effects to e-field concentration.

  • PDF

Partial Discharge Characteristics due to shift of Void Position in XLPE (XLPE에서 보이드 위치변화에 따른 부분방전특성)

  • Kim, Tag-Yong;Yang, Jae-Hoon;Kim, Weon-Jong;Shin, Hyun-Taek;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.86-89
    • /
    • 2004
  • To estimate a electrical performance of the extra high voltage XLPE cable the discharge properties due to shift of void position were investigated. The ${\phi}-q-n$ properties have been measured at room temperature by rising voltage ratio of 0.5[kV]. An obtained data was stored to personal computer through A/D converter. The period of applied wave form and discharge values were divided into 64 parts and discharge values generated during 10 seconds were accumulated by phases. As a result, it was confirmed that the charge, phase angle and counts of discharge changed due to void position.

  • PDF