• Title/Summary/Keyword: 보온커튼

Search Result 35, Processing Time 0.028 seconds

Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse (이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The objective of the present study is to provide data needed to find double covering method to be able to improve environment of temperature, humidity and PPF in tomato greenhouse. The distribution charts of temperature, humidity and PPF which were measured in environment control conditions such as thermal insulation, air heating, roof ventilation and air fog cooling in conventional and air inflated double layers greenhouses were drawn and analysed. The thermal insulation effect of the air inflated greenhouse was the same as that of conventional greenhouse because the temperature between insulation curtain and roof covering material was equal in heating season. The ventilation effect of the air inflated greenhouse was superior to the conventional greenhouse. The temperature distribution in the fog cooled greenhouse was uniform and the cooling effect was about $3.5^{\circ}C$. The condensation on the roof covering surface could be controlled by removing the moisture between insulation curtain and roof covering by using humidifier. The PPF of conventional greenhouse was more decreased than the air inflated greenhouse as time went by because the transmittance of conventional greenhouse declined by dust collected on the inside plastic film owing to rolling up and down operation for ventilation.

Survey of ICT Apply to Plastic Greenhouse, Rack·Pinion Adaption to Single Span and CFD Analysis (온실 ICT융복합 실태조사와 복숭아형 랙피니언천창 적용 단동온실 및 CFD 유동해석)

  • Cho, Kyu Jeong;Kim, Ki Young;Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.4
    • /
    • pp.308-316
    • /
    • 2015
  • This study was conducted to investigate the situation of ICT apply to plastic greenhouse, and the results be apply to design of new one. A CFD analysis were conducted to monitering the ventilation and energy saving of the single span greenhouse newly designed. The causes of delay to apply ICT to plastic greenhouse are the high cost for installation(24%), insufficiency of after services(19%), often disorder(16%), unskillful management of soft ware(15%), insufficient ICT efficiency(13%) and unsatisfying of income increase(12%). The parts of problem occurred in ICT plastic greenhouse are the structure, actuator, environmental control system and sensor(approximate 14%, respectively), remote control technique(13%), plant management technique(12%), energy saving technique(10%) and utilization of software(8%). In the condition of lateral window closed, the average wind speed changed to slow, but it was faster in the condition of leeward side window opened than in the condition of lee and winward side window opened. The air movement in the condition of lateral window closed occur by air moving fan not by out air. It is not affect the room temperature but effective the uniformity of room temperature. The average temperature of low height greenhouse was uniform than high height one. The average temperature in condition of 3rd curtain opened become same with outside temperature after 2 hours, but take more 5 hours in condition of 3rd curtain closed.

Effect of Lavor-saving Opening and Shutting of Thermal Screen on Growth of Tomato in Greenhouse (보온커튼의 성력개폐가 토마토의 생장에 미치는 영향)

  • 조삼증;조일환;허노열;권영삼;김성봉;김진한
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1995.10a
    • /
    • pp.52-53
    • /
    • 1995
  • 우리나라에서 원예생산시설의 형태는 아취형과 터널형이 '94년에 전체 시설면적 37,800ha중 98%를 차지하고 있고, 난방방법에 있어서는 무가온재배가 83%이고 가온재배가 16%로서 아직도 거의가 환경관리에 많은 인력을 요구하는 방식을 채택하고 있다. 그리고 농가인구에 있어서는 매년 감소하여 현재는 11%로 양적으로 줄었고 질적으로도 노동연령의 고령화로 점차 열악해지고 있으며 반면에 소비자의 수요욕구는 고급화하며 외국의 수입개방 압력은 높아져서 시설재배시 기계화와 정밀한 환경관리가 요구되고 있는 실정이다. (중략)

  • PDF

Development of the thermal curtain opening and closing device under heavy load (시설하우스 중하중용 동력개폐장치 개발)

  • 김승희;이공인;김진영;최덕규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.372-377
    • /
    • 2003
  • '92년부터 추진한 농업구조개선으로 시설원예 농업은 현대화 대형화되어 환기를 위한 천측창 개폐장치와 보온을 위한 커튼개폐장치의 자동화로 시설원예농업의 편의성을 증대시켰다. 천측창 동력개폐장치에 있어서는 설치개소가 많고 빈번한 작동으로 일찍이 동력개폐기 문제점이 지적되었고, 그에 따른 많은 개선이 이루어졌다 초기의 동력개폐기는 2단 웜기어 감속방식을 사용하여 동력전달효율이 낮아지고 웜기어의 마모로 고장이 잦고 수명이 짧아지는 문제가 있어 감속방식을 유성기어로 전환하여 실용화되면서 많은 발전을 이루어 왔다. (중략)

  • PDF

업체탐방 - 바이오맥 - 계사 단열은 인슐래드로 해결! -

  • Jang, Seong-Yeong
    • KOREAN POULTRY JOURNAL
    • /
    • v.41 no.5
    • /
    • pp.110-113
    • /
    • 2009
  • 단열목적으로 개발한 최첨단 진공세라믹 소재 인슐래드를 축사에 접목해 탁월한 효과를 자랑하는 기업이 있다. 지난해 벤처기업으로 등록된 바이오맥은 보온 보냉 효과가 뚜렷한 꿈의 소재 '인슐래드' 제품 판매와 '바이오 커튼'을 개발해 업계에서 주목받고 있다. 또한 부화율과 산란율 개선에 효과를 나타내는 항생제대체용 사료첨가제 '애니웰' 제품 개발과 금년부터 의욕적으로 시행하는 HACCP 컨설팅 등 기자재, 사료첨가제, 사양관리 등 축산농가의 모든 부분에 대해 연구하는 기업, 바이오맥을 찾았다.

  • PDF

Experimental Study on the Infiltration Loss in Plastic Greenhouses Equipped with Thermal Curtains (보온커튼을 설치한 플라스틱 온실의 틈새환기전열량 실측조사)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.100-105
    • /
    • 2015
  • The calculation method of infiltration loss in greenhouse has different ideas in each design standard, so there is a big difference in each method according to the size of greenhouses, it is necessary to establish a more accurate method that can be applied to the domestic. In order to provide basic data for the formulation of the calculation method of greenhouse heating load, we measured the infiltration rates using the tracer gas method in plastic greenhouses equipped with various thermal curtains. And then the calculation methods of infiltration loss in greenhouses were reviewed. Infiltration rates of the multi-span and single-span greenhouses were measured in the range of $0.042{\sim}0.245h^{-1}$ and $0.056{\sim}0.336h^{-1}$ respectively, single-span greenhouses appeared to be slightly larger. Infiltration rate of the greenhouse has been shown to significantly decrease depending on the number of thermal curtain layers without separation of single-span and multi-span. As the temperature differences between indoor and outdoor increase, the infiltration rates tended to increase. In the range of low wind speed during the experiments, changes of infiltration rate according to the outdoor wind speed could not find a consistent trend. Infiltration rates for the greenhouse heating design need to present the values at the appropriate temperature difference between indoor and outdoor. The change in the infiltration rate according to the wind speed does not need to be considered because the maximum heating load is calculated at a low wind speed range. However the correction factors to increase slightly the maximum heating load including the overall heat transfer coefficient should be applied at the strong wind regions. After reviewing the calculation method of infiltration loss, a method of using the infiltration heat transfer coefficient and the greenhouse covering area was found to have a problem, a method of using the infiltration rate and the greenhouse volume was determined to be reasonable.

Study on Heating Load Characteristics and Thermal Curtain Effects for Simple Silkworm Rearing Houses(II) -Effects of the Thermal Curtain on Energy Preservation and Review of its Application- (간역잠실(簡易蠶室)의 난방부하특성(暖房負荷特性) 및 보온(保溫)커튼 설치(設置)효과에 관한 연구(硏究)(II) -보온(保溫)커튼의 열(熱) 절감(節減) 효과(効果) 및 적응성(適應性) 검토(檢討)-)

  • Choe, K.J.;Jung, D.H.;Park, K.K.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.1
    • /
    • pp.83-89
    • /
    • 1991
  • One of the most serious problems in Korean sericulture farms is to improve the adiabatic conditions for the simple silkworm rearing houses which has been widely adapted since early 1980'. Thus, this study is aimed to solve the problems by selecting the thermal screen material and by finding the method of its instalation. For the study, 4 kinds of materials which are (1) TE005,(2) NW60, (3) NW300 and (4) AL110 are selected and 4 different types of methods which are surrounding boundary of rearing bed(type A), surrounding inside of wall and ceiling (type B), installing on inside of wal ony (type C) and installing on ceiling Inly (type D) are installed. Decision criteria of the best combination of screen material and installation methods is made by calculating the heating load coefficients and by testing the application at the simple silkworm rearing houses. The obtained results are summarized as follows ; 1. The effect of thermal screen on reducing the thermal energy is remarkable. It saves energy more 50% than unscreened simple silkworm rearing houses. 2. From a stand point of a good screed material on thermal energy reduction, the NW300, AL110 and PE005 are recommanded materials. However, NW60 and PE005 are regarded as desirable materials from the practical point view. 3. Also, the effect on thermal energy reduction is largely affected by the method of thermal screen installation. The surrounding boundary of the silkworm rearing bed(type A) is the most desirable method to reduce the energy, which saves 56.6% of it. 4. In the practical application, NW60 and type A is considered to be the best combination of material and installation method. By this combination, the level of maximum heating load can be reduced at the rate of 43% for spring season and 40% for autumn season. 5. Another heating method, comparted heating, can be recommended to save the energy.

  • PDF

Analysis of the Insulation Effectiveness of the Thermal Insulator by the Installation Methods (보온단열재의 설치방법에 따른 보온성 효과 분석)

  • Kim, Young-Bok;Lee, Si-Young;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.332-340
    • /
    • 2009
  • In this study, the thermal insulation effectiveness of the greenhouse insulators by the installation methods was investigated to find the right installation way of the insulation materials. Physical properties of the insulators such as thickness, air transmissivity, apparent density, ultraviolet rays cutoff ratio, reflectance, thermal conductivity, moisture absorptivity were evaluated and the insulation ability of the insulators were measured by the module experiments. For the same insulator, the insulation ability of the case with the outward direction of the black colored face, i.e., with the inward direction of the white colored face, was better than that of vice versa. The case of the black colored both surfaces was better than the case of the white colored both surfaces. For aluminium reflection material, the case with the outward direction of the lustre face, i.e., with the inward direction of the non-lustre face, was better than that of vice versa. For the same material with the inner thin polyethylene foam (or polyester) and the chemical wool, the case with the outward direction of the inner thin polyethylene foam (or polyester), i.e., with the inward chemical wool, was better than that of vice versa. Addition of the inner thin polyethylene foam increased the insulation effect very much.

Effectiveness of the Aluminum Thermal Screens Depending on the Allocation Type (알루미늄반사재의 배치형태에 따른 보온 효과)

  • Kim, Young-Bok;Park, Joong-Choon;Huh, Moo-Ryong;Lee, Si-Young;Jeong, Sung-Woo
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.284-290
    • /
    • 2007
  • Thermal insulation effectiveness of the aluminum insulator depending on the direction of its glossing face, number of layer and allocation position was investigated. Modules were assembled by the combination of the variables levels and experimented for the case of 100 W and 40 W heating in the modules. The temperatures in the modules with the aluminum insulator were higher than those of the modules with polyester curtains. For the modules with one layer aluminum insulator, the inside temperatures of the modules with the direction of the glossing face outward were higher than those of the modules of inward. For two layer of aluminum insulator, the directions of those glossing faces were recommended to be the same direction for higher thermal insulation effectiveness. For the modules without heating, the temperature difference between the modules were not significant. The black globe temperatures in the modules were changed with the similar tendencies with the dry bulb temperatures in the modules. Those of the black globes were higher than those of the dry bulb temperatures as a whole. It was more distinguished for the modules of inward direction.

Effect of Heat Insulation by Plastic Curtain with Air Cell in Greenhouse (플라스틱 공기막 커튼을 활용한 온실의 보온력 향상)

  • Kim, Hak-Ju;Lee, Si-Young;Yeom, Sung-Hyun;Nam, Yooun-Il;Jeon, Hee;Yoon, Nam-Kyu
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2003.04a
    • /
    • pp.203-206
    • /
    • 2003
  • 우리나라 시설원예 면적은 '95년 43,093ha에서 '01년 말 현재 52,125ha로 연평균 3.2%의 증가율을 보인 반면 난방면적은 연평균 10.8%씩 증가하여 12,710ha로 전체 시설재배 면적의 24.4%를 차지하고 있다. 또한 난방연료의 95% 이상이 경유이며, 최근 국제정세 불안 등으로 유가가 급등하여 시설재배농가의 연료비 부담은 더욱 가중되고 있다. (중략)

  • PDF