Borehole Disposal Concept: A Proposed Option for Disposal of Spent Sealed Radioactive Sources in Tanzania (보어홀 처분 개념: 탄자니아의 폐밀봉선원 처분을 위한 제안)

  • Salehe, Mikidadi;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.4
    • /
    • pp.293-301
    • /
    • 2013
  • Borehole Disposal Concept (BDC) was initiated by the South African Nuclear Energy Corporation (NECSA) with the view to improve the radioactive waste management practices in Africa. At a time when geological disposal of radioactive waste is being considered, the need to protect ground water from possible radioactive contamination and the investigation of radionuclides migration through soil and rocks of zone of aeration into ground water has becomes very imperative. This is why the Borehole Disposal Concept (BDC) is being suggested to address the problem. The concept involves the conditioning and emplacement of disused sealed radioactive sources in an engineered facility of a relatively narrow diameter borehole (260 mm). Tanzania is operating a Radioactive Waste Management Facility where a number of spent sealed radioactive sources with long and short half lives are stored. The activity of spent sealed radioactive sources range from (1E-6 to 8.8E+3 Ci). However, the long term disposal solution is still a problem. This study therefore proposing the country to adopt the BDC, since the repository requires limited land area and has a low probability of human intrusion due to the small footprint of the borehole.

Analysis of Soil Thermal Conductivities, Borehole Thermal Resistances and Initial Soil Temperature with In-Situ Testing in South Korea (현지 측정에 의한 남한지역의 지중유효열전도도, 보어홀 전열저항 및 초기온도 분석)

  • Ro, Jeong-Geun;Yon, Kwangseok;Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.68-74
    • /
    • 2012
  • Investigation of the effective soil thermal conductivity($k$) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. The first step is measured for initial soil temperature. This is done by supplying a only pump power into a borehole heat exchanger. They need to supply into water unload heat power more than 30 minutes. In this study, the initial soil temperature was found to analysis $14.1{\sim}16.0^{\circ}C$,the ratio was 68.7% represented. In this case of $k$, was 2.1~3.0 $W/m{\cdot}k$, $R_b$ was 0.11~0.20 $m{\cdot}K/W$. In this work, it is also shown that the distribution of a soil thermal conductivity and borehole thermal resistance were on the influence of initial soil temperature. And soil thermal conductivity was related with factors of equation by linear least square method, borehole thermal resistance was on the influence of composite factors.

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method (선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

An Experimental Study on Measurement of Flow Coefficient Using the Steady-Flow Test Rig (정상유동장치를 이용한 유량계수 측정에 관한 실험적 연구)

  • Park, Sang-Wook;Choi, Ik-Soo;Noh, Ki-Chol;Ryu, Soon-Pil;Yoon, Keon-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.423-429
    • /
    • 2012
  • Miller cycle is considered as an effective means to meet the regulation on Tier II and to reduce $CO_2$ emission. For this cycle, the amount of intake air supplied should be enough increased. Therefore, the intake system with minimized resistance for air flow is under consideration. In this study, the flow coefficients of intake valves were measured in order to obtain the basic data for the cycle simulation and intake port design. The flow coefficients were measured using the steady-flow test rig. As a test result for the poppet valve used the marine engine with medium speed, the flow coefficients are increased to about 0.62 with the valve lift. In addition it is confirmed that the flow coefficients have the characteristic value irrelevant to the S/B ratio.

Analysis of Interference Effect on FS System from ESIM with Motion Characteristics (이동 특성에 기반한 ESIM이 FS 시스템에 미치는 간섭영향 분석)

  • Kang, Young-Houng;Oh, Dae-Sub
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.5
    • /
    • pp.428-434
    • /
    • 2017
  • In recent years, owing to the growing user demand for the two-way internet service based on the mobile global broadband communications, a new type of satellite terminal has been developed, known as ESIM(Earth Station in Motion). This service was required by Resolution 158(WRC-15) to study on the coexistence with the co-primary FS(Fixed Service) in 27.5-29.5 GHz as a FSS(Fixed Satellite Service) uplink. In this paper, the average received power on ESIM within -10 dB of beam width of FS and its outage probability was analyzed theoretically and also simulated to account for the azimuth angle with uniform distribution. From the results, it can be concluded that this theoretical analysis is very useful to analyze the interference from ESIM into FS based on the statistical and probabilistic method. Therefore, it is necessary to control the azimuth angle due to a moving terminal as well as the inclination angle of moving path, the operation hours, and the speed of ESIM to protect the co-primary FS.

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Power Supply Regulation (부하변동에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Ro, Jeong-Geun;Yon, Kwang-Seok;Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.80-86
    • /
    • 2011
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. This is done by supplying a constant heat power into a borehole heat exchanger. There are two methods to supply a constant heat power. One is to employ the electricity provided by Korea Electric Power Corporation(KEPCO). The other is to use electricity generated by a generator. In this study, the power supply regulation was found to reduce when the electricity generated by the generator was used. This is because the generator evaluated with the power supply characteristically reduces the power supply regulation between an overload and a complex using. But it sometimes occurs a power supply regulation in In-situ thermal response test. In this case getting of k,$R_b$ requires delay times and restored normal state. However, the effect of the delay times and restored normal state on the soil thermal conductivity and borehole thermal resistance is very small. Therefore it is possible to use a generally accepted delay times and restored normal state in the analysis. In this work, it is also shown that an acceptable range of ${\Delta}k$, ${\Delta}R_b$ for normal state and regulation state might be approximately 0.01-0.16W/m k, and -0.004-0.007m K/W, respectively. Thus, restored normal state of power supply regulation is valuable to recommend.

Interpretation and Education of topic phrase shown on the Analects of Confucius (1) - Based on the examples of the 'DO' eventuality meaning phrase (논어 화제구의 해석과 교육(1) - '활동(DO)' 사건의미 표시구의 예를 중심으로)

  • 김종호
    • Journal of Sinology and China Studies
    • /
    • v.79
    • /
    • pp.245-275
    • /
    • 2019
  • The Chinese language is a topic-prominent language and the ancient form of the language is not an exception. This literature examines the theta roles and cases of the arguments by setting sentence structures regarding 'TopP', which marks the eventuality meaning of 'DO', from the Analects of Confucius. Summary of the analysis is as follows: 1. Like the contemporary Chinese, ancient Chinese has two topic types; one is a base-generated topic(so called dangling topic) and the other is a topic generated by the interior movement in the TP. 2. The sentence structure of TopP from the Analects of Confucius that marks the eventuality meaning of 'DO' can be divided into seven categories which are: T+S+V+O', 'T+ES+V+EO', 'T+ES+V+EO', 'T+S+V+EC', 'T+ES+V+C', 'T+ES+V+O+C', 'T+S+V+EO+C'. 3. The predicate(V-v) of TopP from the Analects of Confucius that marks the eventuality meaning of 'DO' has a meaning characteristics of [+ will] and [+ progressive]. 4. The subject of TopP from the Analects of Confucius that marks the eventuality meaning of 'DO' is assigned a thematic role of an , and the object is assigned a thematic role of a . 5. The complement of TopP from the Analects of Confucius that marks the eventuality meaning of 'DO' is composed of overt preposition head and its complements, which receives diverse thematic roles from the preposition. However, it does not have a direct selective relationship but an indirect relationship with the main verb of the sentence. 6. Every argument, which is the subject, object, complement, and adverb, of TopP from the Analects of Confucius that marks the eventuality meaning of 'DO' can theoretically be moved in front of the subject and be topicalized. 7. The topic phrase from the Analects of Confucius that marks the eventuality meaning of 'DO' is derived in the order of predicate(V-v), object, complement, adjunct, subject, and topic, but when interpreting it in Korean it is in inverse order, which is in the order of topic, subject, adjunct, complement, object and predicate(V-v).

Analysis of Thermal Performance of Ground-Source Heat Pump System (지열 이용 히트펌프 시스템의 열성능 해석)

  • Shin, U-Cheul;Baek, Nam-Choon;Kim, Ook-Joong;Koh, Deuk-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.95-101
    • /
    • 2006
  • The purpose of this study is to present the simulation results and an overview of the performance assessment of the Ground-Source Heat Pump(GSHF) system. The calculation was performed for two design factors: the spacing between boreholes and the depth of the vertical ground heat exchangers. And the simulation was carried out using the thermal simulation code TRNSYS with new model of water to water heat pump developed by this study. As a result, it was anticipated that the yearly mean COPs of heat pump for heating and cooling are about 3.7 and 5.8 respectively and the heat pump can supply 100% of heating and cooling load all the year around.

A Study on the Thermal Behavior of Vertical Borehole Heat Exchanger with 1-Dimensional Model (1차원 모델에 의한 지중열교환기의 열거동 해석)

  • Lee, Se-Kyoun;Kim, Dae-Ki;Woo, Joung-Son;Park, Sang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.97-104
    • /
    • 2005
  • A one-dimensional heat transfer model for the vertical borehole system is derived in this study to predict the thermal behavior of the system and surrounding soil. In this model the U-tube is replaced with one effective tube of effective diameter which is surrounded by concentric grout region. All thermal resistances of borehole are counted in the grout region with effective thermal conductivity of grout. Effective thermal conductivity of grout and sand are calculated through parameter estimation. The validity of this model is accomplished through comparison of the predicted temperature profiles of the model with experimental data.

Damping due to Radiation Loss for Axial Vibration of the Pipe in a Fluid-filled Borehole (유체로 채워진 보어홀 속의 파이프 종진동에 있어서 방사손실에 의한 감쇠)

  • 이현엽;류황진
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.631-636
    • /
    • 1997
  • A method to estimate the radiatio power to the surrounding formation due to axial vibration of the pipe in a fluid-filled borehole has been developed, by using the propagation modes of stress wave in an infinitely-long and uniform drilling borehole surrounded by a radially-infinite homogeneous formation. Also, the equivalent damping coefficient for the axial vibration of the pipe has been derived. As an example, results for a real drilling borehole has been presented. The analysis of the elastic motion of the infinite formation which has cylidrical cavity is simplified with the geometric axisymmetry and the low-frequency assumption so that the analytic solution is obtained.

  • PDF