• Title/Summary/Keyword: 보상조정

Search Result 226, Processing Time 0.031 seconds

Equal Bit Rate Control for Low Bit-rate Coder based on Frame Statistics (저 전송률 부호화기를 위한 프레임 특성에 근간한 균등 비트 할당 기법)

  • Seo Dong-Wan;Choe Yoon-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.4
    • /
    • pp.176-181
    • /
    • 2005
  • This paper presents an equal bit rate control algorithm utilizing the statistical change between the previous frame and the current frame. The previous studies on the model-based rate control have focused on the models of bit rate and distortion in types of coders, in terms of the quantization parameter. The proposed algorithm improves the typical model-based rate control by updating a model parameter instead of modeling a better model of the rate and distortion. The proposed algorithm updates this model parameter by recognizing the change in statistics between the previous frame and the current frame. We implement the proposed algorithm in MPEG-4 coders and verify its performance while comparing it to the TMN8's approach (up to 0.6dB of improvement).

  • PDF

Analysis of Reinforcement Learning Methods for BS Switching Operation (기지국 상태 조정을 위한 강화 학습 기법 분석)

  • Park, Hyebin;Lim, Yujin
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.2
    • /
    • pp.351-358
    • /
    • 2018
  • Reinforcement learning is a machine learning method which aims to determine a policy to get optimal actions in dynamic and stochastic environments. But reinforcement learning has high computational complexity and needs a lot of time to get solution, so it is not easily applicable to uncertain and continuous environments. To tackle the complexity problem, AC (actor-critic) method is used and it separates an action-value function into a value function and an action decision policy. Also, in transfer learning method, the knowledge constructed in one environment is adapted to another environment, so it reduces the time to learn in a reinforcement learning method. In this paper, we present AC method and transfer learning method to solve the problem of a reinforcement learning method. Finally, we analyze the case study which a transfer learning method is used to solve BS(base station) switching problem in wireless access networks.

Comparison of occusal aspects in monolithic zirconia crown before and after occlusal adjustment during intraoral try-in: a case report (CAD/CAM으로 제작된 monolithic zirconia crown의 시적 전후 교합양상에 대한 비교)

  • Yong, Ki-Hoon;Shim, Jun-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.246-251
    • /
    • 2014
  • In case of prosthesis fabrication by CAD/CAM, location, area and contour of occlusal contacts can be adjusted so more functional occlusion can be acquired. Also, errors in a manufacturing process is reduced compared to cast metal prostheses and porcelain fused metal prostheses fabricated by conventional methods such as casting and porcelain build up. Therefore, prostheses by CAD/CAM show superior occlusion accuracy. Recently, virtual articulator function has been introduced to CAD/CAM system, which reproduces mandibular movement against maxilla. Thus, it is possible to consider occlusal interference in anterior/lateral movement as well as closing movement. There have been many studies on the marginal and internal fit of prostheses using zirconia but the occlusal fit of zirconia crown fabricated by CAD/CAM has not been researched as much. In this case report, 7 zirconia crowns were designed and fabricated by CAD/CAM for total 5 patients. The models of zirconia crowns before and after occlusal adjustment during intraoral try-in were scanned for occlusal contacts, which were compared to evaluate accuracy of prostheses and understand patterns of occlusal adjustment. Most of the occlusal adjustments were done on functional cusps and slopes of zirconia crown, and the magnitude of occlusal adjustment ranged from $15{\mu}m$ to $60{\mu}m$. In the zirconia crown fabricated with CAD/CAM systems, the occlusal adjustment is a necessary procedure, so additional procedures will be needed for compensating reduced mechanical properties.

New CCM Single Stage PFC Full Bridge Converter (새로운 CCM 단일 전력단 역률보상 풀 브리지 컨버터)

  • Lim, Chang-Seob;Kwon, Soon-Kurl;Cho, Jung-Goo;Song, Doo-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.986-989
    • /
    • 2002
  • This paper proposes a new single stage power factor correction (PFC) full bridge converter which operates at continuous conduction mode(CCM). The proposed single stage PFC consists of typical zero voltage switching(ZVS) full bridge DC/DC converter, two transformer auxiliary windings, and two small inductors, and two diodes. Neither additional active switch nor any control circuit are added for PFC resulting in very low cost. The proposed converter provides input power factor correction with CCM control and tight output voltage regulation. All switching devices are operated under ZVS with minimum voltage stress. Operation principle and analysis are explained and verified with computer simulation and experimental results on a 1.2kW, 100kHz prototype.

  • PDF

Levitation System controlled by Output-compensation control method (출력보상형 제어기법에 의한 부상제어 시스템)

  • Sung, H.K.;Lee, J.M.;Jho, J.M.;Lee, J.M.;Yu, M.W.;Jho, H.J.;Nam, Y.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.313-315
    • /
    • 2006
  • Being controlled by a pole placement, levitation system should need many sensors that measure air-gap, velocity, acceleration, and so on. However, these sensors have observational errors by changed temperature. This paper proposed a output compensated command tracking controller for reducing the error and reducing sensors. Simulation results will be provided to show the validity of the proposed scheme.

  • PDF

Self-exciting A, C, generator (자동자식 교류발전기)

  • 윤병의
    • 전기의세계
    • /
    • v.18 no.3
    • /
    • pp.34-39
    • /
    • 1969
  • 종래 사용되어온 교류발전기의 자동전압조정기는 직류여자기의 계자전류를 제어함으로써 교류 발전기의 단자전압을 일정하게 유지하는 방식이었다. 이경우 정정시의 전압변동을 적게하는 것은 비교적 용이하지만 급격한 부하변동에 대해서는 불경하였다. 즉 발전기에 급히 부하가 걸리면 발전기의 특성에 의하여 결정되는 전압이 순간적으로 떨어지고 또 발전기에는 복권작용이 없고 직류여자기및 제어장치의 시정수에 의한 조정작용의 시간적 늦음이 있기때문에 발전기의 전압은 더욱 강하한다. 이 전압강하의 방지책으로 발전기를 필요이상 크게하여 단종비를 크게하고 또 속응여자를 행하고 있다. 그리고 발전기의 부하가 유도전동기이 가능한 것은 소용량에 한하고 거의 모두 감압기동을 하고 있었다. 이 난점을 보상하기 위해 주회로전류에 의한 복권특성을 갖는 자여자교류발전기가 개발되어 왔으며 근래에는 S.C.R (Silicon Controlled Rectifier)의 발달에 따라 자기증폭기식에서 Transistor-Thyristor식으로 변천하고 있다. 여기서는 자여자발전기를 이용한 정전압장치부 자려자교류벌전기 75KVA에 대한 특성을 소개하고자 한다.

  • PDF

ZVT single phase power factor correction circuit with low conduction loss and low cost (저도통 손실, 저가의 ZVT 단상 역률 보상 회로)

  • Baek, J.W.;Cho, J.G.;Kim, W.H.;Rim, G.H.;Song, D.I.;Kwon, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.255-258
    • /
    • 1996
  • A new low conduction loss, low cost zero-voltage-transition power factor correction circuit(PFC) is presented. Conventional PFC which consists of a bridge diode and a boost converter(one switch) always has three semiconductor conduction drops. Two switch type PFCs reduces conduction loss by reducing one conduction drop but the cost is increased because of increased number of active switches. The proposed PFC reduces conduction loss with one switch, which allows low cost. Conduction loss improvement is a little bit less than that of two switch type, but very close up. Operation and features are comparatively illustrated and verified by simulation and experimental results of 1 kW laboratory prototype.

  • PDF

Novel ZVT Full Bridge PWM Boost Converter with Active Clamp for Single Stage Power Factor Correction (단일 전력단 역률보상을 위한 능동 클램프를 갖는 새로운 영전압 스위칭 풀 브릿지 PWM 컨버어터)

  • 조정구;김학성;백주원;정창용;송두익;유동욱;임근희
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.247-250
    • /
    • 1997
  • A novel zero-voltage-switching(ZVS) isolated PWM converter for single stage power factor correction (PFC) is presented to improve the performance of the previously presented ZVT converter[5]. A simple clamp circuit in the primary side provides zero-voltage-switching condition to all semiconductor devices. This ZVS is achieved with minimum device voltage and current stresses. Operation principle, control strategy and features of the proposed converter are presented and verified by the experimental results from a 1.5 ㎾, 100 KHz laboratory prototype

  • PDF

LED Current controller development Using Buck Converter (벅 컨버터를 이용한 LED 전류제어기 개발)

  • Lee, Yong-Jae;Kim, Jin-Bae;Kim, Chun-Sung;Lim, Sang-Kil;Park, Sung-Jun;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.427-428
    • /
    • 2011
  • 조명용 LED 시스템은 크게 LED 광원과 이 광원을 구동하기 위한 Power부로 구성되며 LED를 이용한 조명용 광원을 구성할 경우 LED 자체가 점광원이므로 면광원 구성을 위해서는 많은 수의 LED Array 구성이 필요하다. LED Array 구성에 있어 직 병렬 구성 및 조합은 직류 공급 장치의 출력 사양을 결정하는 중요한 요인이 된다. 본 논문에서는 온도 변화에 따른 전류변동을 보상하기 위한 DC/DC 컨버터 구조를 제안한다. 컨버터의 Base 입력전압 최대치는 온도변화에 대한 전류변동의 최저치가 되며, 온도변화에 따른 전압 조정을 위한 컨버터는 0~6[V]만을 제어함으로서 낮은 전압으로 전류를 제어하고, 결과적으로 효율을 증대할 수 있을 거라 예상된다.

  • PDF

X-선 검출기의 이득 보정 및 신호처리회로 구성

  • 남욱원;최철성;문신행
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.04a
    • /
    • pp.22-22
    • /
    • 1993
  • 천체 B-선 관측용으로 많이 이용되고 있는 X-선 비례계수관을 실험실형으로 재작하고 그 특성을 조사하였다. X-선 검출기의 구조는 10 $\times$ 20 $\times$ 2cm3 인 검출체적내에 10개의 전극선이 설치되어있는 다중선 비례계수관이며, 검출가스로서 Argon(90%) + CH4 (10%)인 g혼합가스를 사용하였다. 이러한 구조에서 5.9 keV에 대한 에너지 분해능은 16%를 얻었으나, 정상적인 전극연결방법에서는 검출기 끝측에 위치한 전극에서 생기는 electric field 변형매문에, 양극선 배열방향에서 조정된 이득의 군일성이 나쁘게 나타났다. 따라서 다중선들의 각 전극선에 전압보상법(voltage compansation method)을 적용하여 검출기 전반에 걸친 이득의 균일성을 2 % (rms 값) 이내로 보정할 수 있었다. 아울러 신호처리회로 중 에너지분석을 위한 파고분석기, 비 X-선 재거를 위한 상승시간선별기(rise-time discriminator)등을 제작하였으며 이들을 이용한 전반적인 신호처리회로의 구성에 대하여 논하고자 한다.

  • PDF