• Title/Summary/Keyword: 보링시료

Search Result 7, Processing Time 0.022 seconds

Structural-Health Evaluation for Core Zones of Fill Dams in Korea using Electrical Resistivity Survey and No Water Boring Method (전기비저항 탐사와 무수보링을 이용한 국내 필 댐 코어존의 건전성 평가)

  • Lee, Sangjong;Lim, Heuidae;Park, Dongsoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.21-35
    • /
    • 2015
  • Electrical resistivity survey (2D and 3D) were employed for detection of possible weak zone of core zones of three central core earth-rockfill dams in Korea. In the 2D results, the core zones is lower resistivity zone with less than $50{\sim}400ohm{\cdot}m$, and the basement is relatively higher resistivity zone with over $1,000ohm{\cdot}m$. In the 3D results, especially, the weak zone with under $100ohm{\cdot}m$ was detected spatial distribution area in the dam. We also drilled boreholes to collect soil samples of core zones of each dam. Water was not used during boring, because water for rotary wash boring could cause structural damages in earth dams. We found that the soil samples of core zones from all of the boreholes correspond to CL (USCS), but we also found that the fluidized or water-saturated soil samples were found in lower resistivity zones. Therefore, the electrical resistivity survey and drilling method without water are a quick and efficient method for structural-health evaluation which is detection of possible weak zones in earth core rockfill dams.

Experimental and Numerical Methods for Thermal Conductivity of Backfill Soils for Subsea Pipeline (해저배관 뒤채움 흙의 열전도율 산정에 관한 실험 및 수치 해석적 연구)

  • Park, Dong-Su;Seo, Young-Kyo
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.103-110
    • /
    • 2017
  • The temperature of subsea pipeline, approximately as high as $100^{\circ}C$, is significantly higher than the temperature of surrounding sea water and sediment. In this reason, heat can be lost from the subsea pipeline to cause serious operation problem. Therefore it is important that the subsea pipeline must be designed to ensure that heat loss is small enough. Heat loss of unburied pipeline is higher than buried pipeline. For that purpose, trenching and backfilling system is a commonly used method for maintaining flow assurance in subsea pipeline installation. For this commonly used method, knowing thermal conductivity of backfill is essential to protect a heat loss of pipeline. This paper presents thermal conductivity of backfill soil using laboratory model test and numerical analysis for various backfill. In conclusion, it can be seen that higher the sand content of the man-made backfill sample, the higher the thermal conductivity. On the other hand, as the water content increases, the thermal conductivity becomes smaller.

A Study on Reappeared Consolidation Test of In-situ Property and Vertical Deformation of Sample Due to Stress Release (1차원 압밀점토의 응력해방에 의한 수직변형량과 현장재현 압밀시험에 관한 연구)

  • Kim, Jae-Young;Naotoshi, Takada
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.7
    • /
    • pp.75-80
    • /
    • 2008
  • When a saturated clay is sampled in an undisturbed manner from a bore hole, the sample extends vertically and shrinks horizontally under undrained conditions due to stress release. The conventional consolidation test specimen is trimmed from the expanded sample so that its diameter is equal to the inner diameter of the consolidation test ring, and this test procedure does not reproduce the actual consolidation behavior. The measurement of sample extension was conducted by means of overcoring method showed that the extension strains were 1 to 2%. To simulate the in-situ consolidation behavior, we proposed the consolidation test method that uses a specimen with a slightly smaller diameter than the inside diameter of consolidometer so that the specimen expands laterally to the inside of the ring.

The Corrosivity Evaluations on Soil Surrounding the Buried Steel Piles under Manufacturing Plants (플랜트 하부의 강파일 인접 토양의 부식성 평가)

  • Jung, Sungwon;Park, Kyeong-Wan;Jeon, Jae-Young
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.37-43
    • /
    • 2016
  • The corrosivity evaluations on soil surrounding the buried steel piles under manufacturing plants. It was proven that the soil structure of this sample area is composed of several soil layers, and that each layer show the different corrosivity. The predicted average corrosion rates of some layers are about 0.33mm/y, which is over than the general corrosion rate, 0.01-0.02mm/y.

  • PDF

The Characteristics of Sludge Landfill Site in Nanjido (난지도 하수슬러지 매립지의 슬러지 성상분석)

  • Namkoong, Wan;Hwang, Seon Suk;Kim, Chul Soo;Yeun, Bum Han;Ryu, Bum Su
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.4 no.2
    • /
    • pp.47-53
    • /
    • 1996
  • This study was carried out to estimate the amount and the characteristics of sewage sludge disposed of in the Nanjido sludge landfill site. Boring test was conducted to estimated the landfill volume and to get sludge samples to be analyzed. Total analysis and leaching test were performed to find the characteristics of sewage sludge. The Nanjido sludge landfill site had the surface area of $50,000m^2$ and the average depth of 15m. The estimated sludge volume was 600,000ton. Sewage sludge in Nanjido sludge landfill site was very stable. Results of total analysis of heavy metals indicated that the sludge could be classified as a non-hazardous waste according to the California state regulation. The sludge also could be used as compost based on compost quality criteria of foreign countries. Results of Korea Extraction Procedure showed that sewage sludge in Nanjido sludge landfill site was not a hazardous waste.

  • PDF

In-Situ Experiment Method on Evaluation of Debris Flow (토석류 발생량 평가를 위한 현장시험 방법)

  • Song, Byungwoong;Yoon, Hyunseok;Kim, Seongmoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.7
    • /
    • pp.31-38
    • /
    • 2013
  • After debris flow caused damage during recent years, many scholars and engineers have thrown their effort into analyzing risk from debris flow in Korea. But it is hard to predict damage by debris flow taken place in wide area. Recently, SINMAP program is widely well used to estimate the amount of debris flow and its' range. In order to make frequent use of it, the most important thing is selection of accurate input parameters. In-situ experiments, which are avaliable in the mountain, is to be suggested to get dependable input parameters for SINMAP. Those are permeability, cohesion, density, friction angle and thickness in SINMAP. To get those, test pit, block sampling, in-situ density test, auger boring, permeability test on ground surface, borehole shear test and dynamic cone test and so forth were selected. In addition, the reliability of the results will be increased through comparing with those by laboratory tests. Hence, the experiments are hard to enter the sites without temporary road and, if possible, licensing and many times are needed, too. Small size experiments are indeed necessary to get accurate parameters.

Compressional and Shear Wave Properties of Cement Grout Including Carbon Fiber (탄소섬유를 포함한 시멘트 그라우트의 압축파 및 전단파 특성)

  • Choi, Hyojun;Cho, Wanjei;Yune, Chanyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.15-24
    • /
    • 2021
  • In Korea, which is mostly mountainous, the proportion of tunnel and underground space development are increasing. Although the ground is reinforced by applying the ground improvement method during underground space development, accidents still occur frequently in Korea. In the grouting method, a representative ground reinforcement method, the effect was judged by comparing the total amount of injection material with the amount of injection material used during the actual grouting construction. However, it is difficult to determine whether the ground reinforcement is properly performed during construction or within the target ground. In order to solve this problem, it is necessary to study a new method for quality control during or after construction by measuring electrical resistivity after performing grouting by mixing carbon fiber, which is a conductive material, and microcement, which is a grout material. In this study, as a basic study, a cement specimen mix ed with 0%, 3%, 5%, 7% of carbon fiber was prepared to evaluate the performance of the grout material mixed with carbon fiber, which is a conductive material. The prepared specimens were wet curing for 3 days, 7 days, and 28 days under 99% humidity, and then compression wave velocity and shear wave velocity were measured. As a result of the compression wave velocity and shear wave velocity measurement, it showed a tendency to increase with the increase in the compounding ratio of carbon fibers and the number of days of age, and it was confirmed that the elastic modulus and shear modulus, which are the stiffness of the material, also increased.