• Title/Summary/Keyword: 보강 웨브

Search Result 42, Processing Time 0.024 seconds

Minimum Weight Design for Web Frames of Cargo Tanks in the LPG Carrier (LPG 운반선 화물창의 웨브 프레임 최소중량설계)

  • Park, Myeong-Chul;Shin, Sang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.103-108
    • /
    • 2020
  • Generally, the cargo tank of LPG carriers corresponds to an independent tank Type A defined by the International Maritime Organization (IMO). The outside of the tank is insulated by polyurethane foam, and the tank is made of expensive low temperature steel that can withstand temperatures as low as -50℃. The cargo tank is composed of outer shell plates, bulkheads, stiffeners, web frames, and stringers. Among them, the outer shell plates, bulkheads, and stiffeners can be designed without structural analysis by the Classification Rules and are constructed easily through optimal design. On the other hand, optimal design, including numerous structural analysis, is not performed because web frames and stringers should be designed and approved through structural analysis. Only adequate design, which determines the design dimensions through several dozen structural analysis, is performed. In this study, for finite element analysis, eight loading conditions were applied, and the deformation of the entire ship for each loading condition was considered. The minimum weight design was performed for the web frames of cargo tanks in the 82,000 ㎥ LNG carrier through the gradient-based optimization technique, and the weight was reduced by approximately 108 tons per ship.

Seismic Performance Evaluation of Concrete-filled U-shaped Mega Composite Beams (콘크리트 채움 U형 메가 합성보의 내진성능 평가)

  • Lee, Cheol Ho;Ahn, Jae Kwon;Kim, Dae Kyung;Park, Ji-Hun;Lee, Seung Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.2
    • /
    • pp.111-122
    • /
    • 2017
  • In this paper, the applicability of a 1900mm-deep concrete-filled U-shaped composite beam to composite ordinary moment frames (C-OMFs) was investigated based on existing test results from smaller-sized specimens and supplemental numerical studies since full-scale seismic testing of such a huge sized beam is practically impossible. The key issue was the web local buckling of concrete-filled U section under negative bending. Based on 13 existing test results compiled, the relationship between web slenderness and story drift capacity was obtained. From this relationship, a 1900mm-deep mega beam, fabricated with 25mm-thick plate was expected to experience the web local buckling at 2% story drift and eventually reach a story drift over 3%, thus much exceeding the requirements of C-OMFs. The limiting width to thickness ratio according to the 2010 AISC Specification was shown to be conservative for U section webs of this study. The test-validated supplemental nonlinear finite element analysis was also conducted to further investigate the effects of the horizontal stiffeners (used to tie two webs of a U section) on web local buckling and flexural strength. First, it is shown that the nominal plastic moment under negative bending can be developed without using the horizontal stiffeners, although the presence of the stiffeners can delay the occurrence of web local buckling and restrain its propagation. Considering all these, it is concluded that the 1900mm-deep concrete-filled U-shaped composite beam investigated can be conservatively applied to C-OMFs. Finally, some useful recommendations for the arrangement and design of the horizontal stiffeners are also recommended based on the numerical results.

Experimental Study on Fatigue Crack in Welded Crane Runway Girders(I) -Initiation and Propagation of Fatigue Crack- (크레인 거더의 피로균열에 관한 실험적 연구(I) -피로균열의 발생과 진전-)

  • Im, Sung Woo;Kim, Jin Ho;Chang, In Hwa;Shinga, Atsumi
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.237-248
    • /
    • 1997
  • Three types of fatigue cracks frequently observed in the crane runway girders are verified experimentally using two testing-purpose girders with the size of $6400{\times}600{\times}300$ in millimeters. The fatigue cracks are observed in the vicinity of load-bearing points, at the end of gusset plates and at the fillet welded joints between the lower flange and the web. The load-bearing-point cracks are initiated at the intersection of the fillet welds between the upper flange and the web, where the vertical stiffener is located. The cracks grow up toward the diagonal direction of the web. The cracks observed at the fillet welded joints grow up perpendicularly to the crane runway girder. Compared with the JSSC fatigue design code, the joint class is classified as follows: E for the vicinity of load-bearing points, G or H for the end of gusset plates and D for the lower fillet welded joints. The tests reveal that the class of joint classification at the end of gusset plates and at the lower flange coincides with the fatigue design code.

  • PDF

Moment-Curvature Relationship of Structural Wells with Confined Boundary Element (단부 횡보강된 구조벽의 모멘트-곡률 관계)

  • Kang, Su-Min;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.323-334
    • /
    • 2003
  • For performance-based design using nonlinear static analysis, it is required to predict the inelastic behavior of structural members accurately. In the present study, a nonlinear numerical analysis was peformed to develop the method describing the moment-curvature relationship of structural wall with boundary confinement. Through the numerical analysis, variations of behavioral characteristics and failure mechanism with the arrangement of vertical reinforcement and the length of boundary confinement were studied. According to the analysis, the maximum moment-carrying capacity of structural walls with adequately confined boundary elements is developed at the moment the unconfined concrete reaches the ultimate compressive strain. Walls with flexural re-bars concentrated on the boundaries fails in a brittle manner. As vortical re-bars in the web increases, the brittle failure is prevented and a ductile failure occurs. Based on the findings, moment-curvature curves for walls with a variety of re-bar arrangement were developed. According to the proposed relationships, deformability of the structural walls wth boundary confinement increases as the compressive strength of the confined concrete increases compared to the applied compressive force.

Study on Fire Resistance of H-Section Beams Filled with Concrete at Web (웨브 보강 형태에 따른 H형강 보부재의 내화성능에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.76-84
    • /
    • 2011
  • Steel beams are one of primary member and those carries the horizontal load and floor load to axial member. To avoid structural failure when the steel beams are exposed to fire, fire resistance performance requires. Till now, the evaluation for fire resistance of the beam was conducted using the maximum load and standard fire curve defined in the KS F 2257. But recently the constructional patterns are changing toward multi-function performance to get a better structural performance and fire resistance as well. In this paper to get the databases for fire resistance, limiting temperatures of the beam, load-bearing fire tests according to load ratios, two grades of compressive concrete strengths were applied.

A Parametric Study for Bending Behavior of Perfobond FRP-Concrete Composite Beam (퍼포본드 FRP-콘크리트 합성보의 휨거동에 관한 매개변수 연구)

  • Yoo, Seung-Woon;Kook, Moo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2396-2402
    • /
    • 2012
  • In recent years, the use of hybrid fiber reinforced polymer(FRP)-concrete members with a dual purpose of both formwork and reinforcement, has been considered in some structures and has been applied in a small number of bridge decks. Numerical simulations of the beam failure tests were performed using nonlinear finite element program and a parametric study was performed with variables of perfobond shape. The ultimate strength was increased with perfobond shape because of dowel action. It was showed a good performance in case of approximately perforate diameter 25~35mm in this case.

Monotonic Loading Test for CFT Square Column-to-Beam Partially Restrained Composite Connection (CFT 각형 기둥-보 합성 반강접 접합부의 단조가력 실험)

  • Choi, Sung Mo;Park, Su Hee;Park, Young Wook;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.325-335
    • /
    • 2005
  • This study tackles the development of an improved detail of partially restrained CFT square column-to-beam connection and the evaluation of its mechanical behavior under monotonic loading. The connection is designed to strengthen shearing capacity at the bottom of the connection due to the ultimate behavior of PR-CC by its detail of the bottom connection and simplify the fabrication process. The suggested connection is the welded bottom beam flange connection(M-2) and is compared with the existing PR-CC of bolted seat angle connection(M-1). Two specimens were fabricated in actual size and tested under monotonic loading. Based on the test results, the welded bottom beam flange connection exhibited about 85% of the stiffness of steel beam. It was similar to the bolted seat angle connection and behaved as PR-CC. The specimen of the supposed connection type failed at the shear connection of web but was similar to the bolted seat angle connection until the failure. It obtained sufficient stiffness and capacity through the reinforcingsteel and the capacity and deformational ability equivalent to the full-plastic moment through the anchor inside the steel tube at the web connection. So, it can be said that the suggested connection exhibits sufficient ductile behavior.

An Experimental Study on the Behaviours of Reinforced Concrete Beam with Openning (철근 콘크리트 유공보의 거동에 관한 실험적 연구)

  • Kim, Cheol-Hwan;Jung, Hwan-Mok;Lee, Chang-Dae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.3 s.13
    • /
    • pp.57-63
    • /
    • 2004
  • Many researches have been conducted to describe the structural behaviour of reinforced concrete beams with openings, and were generally concentrated on the shear behaviours. The objective of this paper is to study the shear and bending capacities of RC beams with openning. In experimental study, a total of seven RC beam with circular opennings under monotonic loading conditions were investigated. The parameters used in this study include the openning size and the existence of re-bar.

  • PDF

Study on the Vibration Characteristics of Light-Weight Void Composite Floor using GFRP (GFRP를 이용한 경량중공 합성 바닥의 진동 특성에 관한 연구)

  • Ryu, Jae-Ho;Park, Se-Ho;Ju, Young-Kyu;Kim, Sang-Dae
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.35.1-35.1
    • /
    • 2010
  • 최근 고층형 주거 시설이 많이 보편화됨에 따라 층고절감과 시공의 효율성 제고 등에 대한 요구가 크게 증가하고 있다. 이에 층고를 절감하면서 동시에 장스팬을 구현할 수 있는 GFRP를 이용한 경량 중공 합성 바닥을 개발하였다. 이 바닥 시스템은 웨브에 개구부를 가지는 비대칭 철골보와 중공 경량체, 콘크리트 그리고 내력 보강 및 내화 성능 증진을 위해 비대칭 철골보 하부에 부착한 GFRP(Glass Fiber Reinforced Plastics)로 구성된다. 본 연구에서는 이 GFRP를 이용한 경량중공 합성 바닥의 진동 특성을 부재 단위 실험체를 제작하여 실험적으로 검토하였으며, 이를 통해 본 개발 합성 바닥의 고유 진동수 및 감쇠율을 측정하였다, 그 결과 기존의 이론에 근접한 진동 특성을 나타내었다.

  • PDF

Flexural Capacity of the Encased(Slim Floor) Composite Beams with Web Openings -Deep Deck Plate and Asymmetric Steel Beam to be Welded Cover Plate- (매립형 (슬림플로어) 유공 합성보의 휨성능 평가 -춤이 깊은 데크플레이트와 비대칭 H형강 철골보-)

  • Kwak, Myong Keun;Heo, Byung Wook;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.575-586
    • /
    • 2004
  • This paper presents an experimental study on the flexural capacity of an encased(slim-floor) composite beam, which is a wider plate under bottom flange of H-beam with web openings. Five simple full-scale bending tests were conducted on the encased(slim-floor) composite beams at varying steel beam heights (250mm and 300mm), positions of web openings, and loading conditions. The test results revealed that the web-open encased composite beam had sufficient composite action, without any additional shear connection devices, because of the inherent shear-bond effects between the steel beam and the concrete, and a stable structural performance without web-opening reinforcements.