• Title/Summary/Keyword: 보강비

Search Result 1,988, Processing Time 0.03 seconds

Flexural Behavior of Concrete Beams Reinforced with CFRP rebars (CFRP Rebar로 보강한 콘크리트 보의 휨 거동)

  • Lee, Young-Hak;Won, Dong-Min;Kim, Min-Sook;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2010
  • To address the problems caused by the corrosion of steel rebar, active research has recently been carried out on members where fiber-reinforced polymer (FRP) is used in place of rebar. As FRP bar is highly brittle and has a low modulus of elasticity, further research is needed on the evaluation of serviceability, in other words on the deflection of flexural concrete members reinforced with FRP rebars. Taking the reinforcement ratio as a variable, this paper analyzes the flexural capacity of concrete beams reinforced with CFRP rebar. The test results of specimens reinforced with CFRP rebar show an increase in stiffness and resisting force along with an increase in the reinforcement ratio. A reinforcement ratio of about 1.3 is needed for the member reinforced with CFRP rebar to show same section property of a steel member. Through a comparison for the value of an effective moment of inertia, the equation suggested by Bischoff & Scanlon predicted values closest to the actual results.

Ductile Strengthening of Reinforced Concrete Beams by Partially Unbonded NSM Hybrid FRP Rebars (부분 비부착 NSM Hybrid FRP 보강근에 의한 철근콘크리트보의 연성보강)

  • Lee, Cha-Don;Chung, Sang-Mo;Won, Jong-Pil;Lee, Sng-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.143-153
    • /
    • 2003
  • New strengthening method based on Near Surface Mounted technique (NSM) is suggested, which can overcome the brittle nature of failure inherent to those reinforced concrete beams strengthened with FRP composite materials. The suggested technique secures ductile failure of reinforced concrete beams by having the strengthening Hybrid FRP rebars unbonded in parts. Experiments were performed in order to compare structural behaviors of strengthened beams with and without unbending along the Hybrid FRP rebars. Test results showed that only those beams strengthened by partially unbonded NSM failed in ductile manner. Theoretical expressions were derived for the minimum unbonded length of Hybrid FRP rebars with which ultimate strength of the reinforced concrete beam with partially unbonded NSM could be reached. The suggested partially unbonded NSM technique is expected to significantly improve the structural behavior of the strengthened beam with FRP composite materials.

Behavior of GFRP reinforced decks with various reinforcement ratio (GFRP 보강근으로 보강된 바닥판의 보강비에 따른 거동 실험)

  • You, Young-Jun;Park, Ji-Sun;Park, Young-Hwan;Kim, Hyeong-Yeol;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.49-52
    • /
    • 2008
  • The tensile and bond performance of GFRP rebar are different from those of conventional steel reinforcement. It requires some studies on concrete members reinforced with GFRP reinforcing bars to apply it to concrete structures. GFRP has some advantages such as high specific strength, low weight, non-corrosive nature, and disadvantage of larger deflection due to the lower modulus of elasticity than that of steel. Bridge deck is a preferred structure to apply FRP rebars due to the increase of flexural capacity by arching action. This paper focuses on the behavior of concrete bridge deck reinforced with newly developed GFRP rebar. A total of three real size bridge deck specimens were made and tested. Main variable was reinforcement ratio of GFRP rebar. Static test was performed with the load of DB-24 level until failure. Test results were compared and analyzed with ultimate load, deflection behavior.

  • PDF

New Constitutive Models for Tensile/Compressive Nonlinear Elastic Behaviors of Composite Materials with Fiber Waviness (굴곡진 보강섬유를 가진 복합재료의 인장/압축 비선형 거동을 예측하기 위한 새로운 해석모델의 개발에 관한 연구)

  • 전홍재;신재윤;최흥섭
    • Composites Research
    • /
    • v.12 no.1
    • /
    • pp.59-67
    • /
    • 1999
  • The effects of fiber waviness on tensile/compressive nonlinear elastic behaviors of graphite/epoxy unidirectional composite materials are studied theoretically and experimentally. New constitutive models are proposed to predict elastic properties and tensile/compressive nonlinear behaviors of composite materials. Three types of wavy pattern are considered: uniform, graded and localized fiber waviness. Complementary energy density and incremental method are used to incorporate the material and geometrical nonlinearities due to fiber waviness. Tensile/compressive tests are conducted on the specimens with fiber waviness. It is found that the predictions are in good agreement with the experimental results.

  • PDF

Flexural Crack for Fiber-Reinforced-Polymer Reinforced Concrete Beams (GFRP 보강근 콘크리트 보의 휨균열)

  • Park, Jong-Sup;Park, Young-Hwan;You, Young-Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.273-276
    • /
    • 2008
  • The use of FRP(Fiber Reinforced Polymer) bars to replace conventional steel bars in reinforcing concrete structures is currently encouraged by many structural engineers, especially for their noncorrosive properties. The partial inferiority of the bond and mechanical properties for FRP bars, however, leads to wider and deeper cracks compared with those of steel reinforced concrete structures. This paper presents experimental results of concrete beams reinforced with FRP bars tested under static loading conditions up to failure. The study focuses on the effects of the reinforcement ratio on the behavior of concrete beams at various stages during loading. The study also attempts to establish a theoretical basis for the development of simple and rational design procedures for concrete beams reinforced with FRP bars.

  • PDF

Experimental Study On Seismic Behavior Of Masonry Walls With Column (기둥 및 벽체가 보강된 조적벽체의 지진거동에 대한 실험적 연구)

  • Kikuchi, Kenji;Park, Kang-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.2 s.20
    • /
    • pp.93-105
    • /
    • 2006
  • In order to investigate the effect of the height of application point of lateral loads and reinforcing steel bars in walls and columns in improving the seismic behavior of confined concrete block masonry walls, an experimental research program is conducted. A total of twelve one-half scale specimens are tested under repeated lateral loads. Specimens are tested to failure with increasing maximum lateral drifts while a vertical axial load was applied and maintained constant. The specimens adopted are two-dimensional (2D) hollow concrete block masonry walls with different parameters such as shear span ratio, inflection point and percent of reinforcement in confining columns and walls. Test results obtained for each specimen include cracking patterns, load-deflection curve, and strains in reinforcement and walls in critical locations. Analysis of test data showed that above parameters generate a considerable effect on the seismic performance of confined concrete block masonry walls.

  • PDF

Improvement of Seismic Performance of Existing Bridges using Isolation (지진격리장치를 이용한 기존 교량의 내진성능 향상)

  • 한경봉;김민지;박선규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.9-17
    • /
    • 2004
  • The seismic performance evaluation and retrofit process are very important in old existing bridges. If the result is not appropriate. then a retrofit process are required. Among various retrofit methods, the seismic isolation is a very useful method. because it can be applied by replacing old bridge bearings. In this study, the effectiveness of seismic isolation is rationally verified. For this purpose, two seismic isolations used widely are selected and non-linear static and dynamic analyses are performed. The responses of existing bridges are compared with those of retrofited bridges by seismic isolation bridge for earthquake of target level. and seismic performances are evaluated.

A study on reinforcement method of concrete structures using composite fiber panels (복합섬유 패널을 이용한 콘크리트 구조물의 보강공법에 관한 연구)

  • Kim, Woon-Hak;Hwang, Sung-Woon;Kang, Seok-Won;Kim, Jeong-Su
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.198-199
    • /
    • 2016
  • 기존 콘크리트 구조물의 내력 및 처짐에 저항하기 위하여 섬유시트를 사용한 복합섬유 패널 보강재를 셋 앵커를 이용하여 콘크리트 구조물과 일체화시키는 공법을 개발하였다.. 본 연구에서 적용된 실험 결과에 의하면 엥커+에폭시 보강 I 시험체가 기준시험체에 비하여 최대하중이 3.13배 증가, 동일 앵커갯수인 앵커보강시험체에 비하여 1.14배 증가하여으며, 에폭시보강시험체는 기준시험체에 비하여 최대하중이 3.08배 증가하였으나 계면에서 섬유박리로 인한 취성 파괴가 발생하였다.

  • PDF

The Effect of Preloading to Reinforced Clay (선행하중이 보강점성토에 미치는 효과)

  • ;Tatsuoka, Fumio
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.5
    • /
    • pp.19-25
    • /
    • 2000
  • 배수성과 인장강성을 가지는 복합 보강재를 사용하여 보강한 포화점성토의 거동에 선행하중이 미치는 영향을 조사하기위하여 평면변형을 시험을 수행하였다. 보강하지 않은 공시체와 보강한 공시체에 대하여 이방압밀(K=0.3, σ3'=50kPa)을 실시하고 비배수 및 배수전단시험을 일정변형율 속도를 실시하였다. 선행하중을 가한 시험의 경우는 이방압밀후 소정의 선행하중을 가하여 크리이프, 제하, 에이징 후에 비배수 전단시험을 실시하였다. 시험결과 분석한 결과 포화전성성토와 같이 연약한 토질이라도 다짐을 잘하고 보강토의 큰 배수압툭강도를 이용하여 큰 배수압축강도를 이용하여 큰 선행하중을 가하여 과압밀 상태로 함으로써 비배수 전단시에 큰 초기강성을 가지는 것을 알수 있었다. 즉, 점성토의 보강토의 경우 보강에 의한 배수강도의 증가는 큰 선행하중을 가하기 위하여 사용하는 것이 가장 효율적인 것으로 판단된다.

  • PDF

An Experimental Study on Flexural Behavior of RC Beams Strengthened with Hi-Strength Bars(3) (고장력 인장봉으로 보강된 RC 보의 휨 거동에 관한 실험적 연구(3))

  • Shin, Kyung-Jae;Kim, Yoon-Jung;Moon, Jeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.351-358
    • /
    • 2007
  • Unlike external bonded steel plate or carbon fiber, the external unbonded strengthening using hi-strength bar has some advantages in speed and simplicity of installation. It is not required surface preparations and not affected by environmental conditions. A set of nine laboratory tests on RC beams strengthened using the hi-tension bars are reported. Anchoring pin developed in former research is installed at the end of beam to connect the hish-tension bar to RC beam. The test results strengthened by hi-tension bars are compared with those of non-strengthened specimens. The main test parameters are the cross-sectional area of the high-tension bar, distance of stirrups and condition of supports. Test results show that the beams reinforced are superior to reference specimens, especially for the strength and deformation capacity. Also, shear resisting effect of hi-strength bar can be confirmed in the specimens which have lack of stirrups.