• Title/Summary/Keyword: 병원인지도

Search Result 24,193, Processing Time 0.062 seconds

Validity of Clinically Used Tray Transmission Factor (임상적으로 쓰이는 차폐선반투과율의 타당성에 관한 연구)

  • 윤형근
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.218-224
    • /
    • 2003
  • Purpose:By evaluating the dependence of the tray transmission factor (tray factor) on collimator setting and tray thickness, we determined the validity of the clinically used single tray factor for standard radiation field size (10${\times}$10 $\textrm{cm}^2$). Methods and Materials:For each X ray energies (6 and 10 MV), outputs were measured by using 5 steps of tray thickness (0, 6, 8, 10, 12 mm) and 7 steps of radiation field size (5${\times}$5, 10${\times}$10, 15${\times}$15, 20${\times}$20, 25${\times}$25, 30${\times}$30, 35${\times}$35 $\textrm{cm}^2$) at 10 cm phantom depth. Outputs were measured in both 'with tray' and 'without tray' conditions by using radiation with the same monitor units, and the tray factors were determined by the ratios of the two outputs. To evaluate the validity of a single tray factor obtained for standard radiation field, we analyzed the pattern of the field sizes in cases treated at our hospital in 2002. Results : In the 6 MV X-ray, the increases in the tray factor between the standard field (l0${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.835%, 1.058%, 1.066% in 6, 8, 10, and 12 mm thickness tray, respectively. In the 10 MV X-ray, the increases in the fray factor between the standard field (10${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.836%, 1.058%, 1.066% in 6, 8, 10, 12 mm thickness tray, respectively. In a major portion of clinical cases, when the field size was smaller than 20${\times}$20 $\textrm{cm}^2$, the tray factor was in good agreement with the standard tray factor. However, in cases where the field sizes were 30${\times}$30 $\textrm{cm}^2$ and 35${\times}$35 $\textrm{cm}^2$, the error could exceed 1.0%. Conclusion:The tray factor increased with increasing field size or decreasing tray thickness. The difference of tray factor between the small field and the large field increased with increasing tray thickness. Furthermore, the standard tray factor was valid in most clinical cases except for when the field size was greater than 30${\times}$30 $\textrm{cm}^2$, wherein the error could exceed 1.0%.

  • PDF

The comparison of predicted adult height change and height gain after gonadotropin-releasing hormone agonist and combined growth hormone treatment in girls with idiopathic central precocious puberty (진성 성조숙증으로 진단 받은 여아에서 gonadotropin-releasing hormone agonist 단독치료 및 growth hormone의 병합치료 시 예측 성인키의 변화 및 성장 획득의 비교)

  • Seo, Ji-Young;Yoon, In-Suk;Shin, Choong-Ho;Yang, Sei-Won
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.3
    • /
    • pp.305-311
    • /
    • 2006
  • Purpose : GnRH analogues(GnRHa) are used to treat central precocious puberty(CPP). However, in some patients, the GV decrease is so remarkable that it impairs predicted adult height(PAH); and there fore, the addition of growth hormone(GH) is suggested. We analysed the growth changes during two years and final adult height(FAH) in girls with idiopathic CPP treated with combined therapy, compared with those of girls treated with GnRHa alone. Methods : For the analysis, we classified the patients, who was treated for longer than two years, into three groups depending on the initial PAH and combination of GH; PAH_L, treated with GnRHa and PAH less than midparental height(MPH) - 5 cm. PAH_H, treated with GnRHa and PAH greater than MPH - 5 cm. GnRHa+GH, combined GH treatment, regardless of PAH before treatment. We analysed the GV and PAH change during the first two years and FAH. Results : In PAH_L, the PAH(SDS) at first year of therapy was significantly increased to $153.5{\pm}6.5cm(-1.4{\pm}1.3)$ from $149.7{\pm}6.4cm(-2.1{\pm}1.3)$ before treatment(P=0.004). In PAH_H, there was no significant increase in PAH during the two years of treatment. During the first year of combination of GH and GnRHa, GV and PAH increased significantly. We observed significant increases in FAH, comparing to the initial PAH in the PAH_L and GnRHa+GH groups. The height gains(FAH - initial PAH) were significantly higher in the PAH_L and GnRHa+GH groups than that in the PAH_H group. Conclusion : This study suggests the FAH and height gains are improved in patients, whose predicted adult height before treatment was shorter than those with higher predicted adult height, with the treatment of GnRHa alone or in combination with GH. GH could not improve the final adult height, but compensated the growth in patients whose growth velocity was decelerated by GnRHa alone.

The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.

Clinical Features of Acute Nonspecific Mesenteric Lymphadenitis and Factors for Differential Diagnosis with Acute Appendicitis (급성 비특이성 장간막 림프절염의 임상 소견과 급성 충수돌기염과의 감별 인자)

  • Shin, Kyung Hwa;Kim, Gab Cheol;Lee, Jung Kwon;Lee, Young Hwan;Kam, Sin;Hwang, Jin Bok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.31-39
    • /
    • 2004
  • Purpose: Although acute nonspecific mesenteric lymphadenitis (ANML) is probably common cause of abdominal pain in children, which can be severe enough to be an abdominal emergency, the clinical features of mesenteric lymphadenitis are not clear. Also, a differential diagnosis with acute appendicitis (APPE) is indispensable to avoid serious complications. The clinical features of ANML were determined, and the risk factors for differential diagnosis with APPE were analyzed. Methods: Between November 2000 and May 2001, data from 26 patients (aged 1 to 11 years) with ANML and 21 patients (aged 2 to 13 years) with APPE were reviewed. ANML was defined as a cluster of five or more lymph nodes measuring 10 mm or greater in their longitudinal diameter in the right lower quadrant (RLQ) without an identifiable specific inflammatory process on the ultrasonographic examination. There were risk factors on patient's history, physical examination, and laboratory examination; the location of abdominal pain, abdominal rigidity, rebound tenderness, fever, nocturnal pain, the vomiting intensity, the diarrhea intensity, the symptom duration, and the peripheral blood leukocytes count. Results: Of the 26 ANML patients and 21 APPE patients, abdominal pain was noted on periumbilical (76.9% vs 14.2%), on RLQ (11.5% vs 71.4%), with abdomen rigidity (7.6% vs 80.9%), with rebound tenderness (0.0% vs 76.1%)(p<0.05), in the lower abdomen (11.5% vs 14.2%), and at night (80.8% vs 100.0%) (p>0.05). The clinical symptoms were vomiting (38.4% vs 90.4%), the vomiting intensity ($1.5{\pm}0.7$ [1~3]/day vs $4.5{\pm}2.9$ [1~10]/day), diarrhea (65.3% vs 28.5%) (p<0.05), and fever (61.5% vs 76.2%)(p>0.05). The period to the subsidence of abdominal pain in the ANMA patients was $2.5{\pm}0.5$ (2~3) days. The laboratory data showed a significant difference in the peripheral blood leukocytes count ($8,403{\pm}1,737[5,900{\sim}12,300]/mm^3\;vs\;15,471{\pm}3,749[5,400{\sim}20,800]/mm^3$)(p<0.05). Discriminant analysis between ANML and APPE showed that the independent discriminant factors were a vomiting intensity and the peripheral blood leukocytes count and the discriminant power was 95.7%. Conclusion: The clinical characteristics of ANML were abrupt onset of periumbilical pain without rigidity or rebound tenderness, a mild vomiting intensity, normal peripheral leukocytes count, and relatively short clinical course. If the abdominal pain persist for more than 3 days, and/or the vomiting intensity is more than 3 times/day, and/or the peripheral leukocytes count is over $13,500/mm^3$, abdominal ultrasonography is recommended to rule out APPE.

  • PDF

Leukocyte count and hypertension in the health screening data of some rural and urban residents (일부 농촌과 도시의 건강선별조사 자료로 본 백혈구수와 고혈압과의 관계)

  • Lee, Choong-Won;Yoon, Nung-Ki;Lee, Sung-Kwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.3 s.35
    • /
    • pp.363-372
    • /
    • 1991
  • We used the health screening data of some rural and urban residents to examine the cross-sectional association between leukocyte count and hypertension. The 206 male and 203 female rural residents were selected by multi-stage cluster sampling method in Kyungsan-Kun area of Kyungbuk province in 1985 and 600 urban residents were selected by the same sampling method as the rural residents in Daegu city of the same province in 1986 compatible with age-sex distribution of Daegu city of 1985 census, but of whom 384 actually responded. The rest of 600 were replaced by age and sex with those who were members of the medical insurance plan visiting the health management department of the university hospital to get the biannual preventive medical checkups. Excluded in the analysis were those having hypertensive history, diseases and extreme outlying values of the screening tests, leaving 373 rural and 571 urban residents. Leukocyte count was measured with ELT-8 Laser shadow method and the unit $cells/mm^3$, Blood pressures were determined with an aneroid sphygmomanometer with pre-standardized method and hypertensives were defined as those showing systolic blood pressure more than 140mmHg and/or diastolic blood pressure more than 90mmHg. Total residents pooled (N=944) showed a significant difference between hypertensives and normotensives ($6965.93{\pm}1997.01\;vs\;6490.61{\pm}1941.32,\;P=0.00$) and in rural residents was noted the similar significant difference (P=0.03). None of significant differences were noted in any stratum stratified by residency and sex. Compared to the lowest quintile of WBC, 2/5 quintile showed odds ratio 0.99 (95% Confidence interval, Ci 0.62-1.59), 3/5 quintile 1.41 (95% CI 0.90-2.21), 4/5 quintile 1.76 (95% CI. 1.14-2.72), and highest quintile 1.80 (1.15-2.82) in the total residents. Likelihood ratio test for linear trend for it indicated a significant trend ($X^2_{trend}=5.53,\;df=1,\;P<0.05$). There were no other significant odds ratios compared to the lowest quintile of WBC in strata stratified by residency and sex. The odds ratios in total residents which had showed significant odds ratios became nonsignificant and of reduced magnitude after controlling age, frequency of smoking and drinking with multiple logistic. regression. In each stratum, it changed magnitudes of odds ratios slightly and unstably. None of the trend tests showed any significant trend. These results suggest that the Friedman et al's finding of association between leukocyte count and hypertension may be due to an statistical type I error resulting from the data dredging in an exploratory study, in which more than 800 variables were screened as possible predictors of hypertension.

  • PDF

Association of Serum Copper and Zinc Levels with Liver Cirrhosis and Hepatocellular Carcinoma (간경변 및 간암과 혈청 구리와 아연농도와의 관련성)

  • Hyun, Myung-Soo;Suh, Suk-Kwon;Yoon, Nung-Ki;Lee, Jong-Young;Lee, Seoung-Hoon;Lee, Mu-Sik
    • Journal of Preventive Medicine and Public Health
    • /
    • v.25 no.2 s.38
    • /
    • pp.127-140
    • /
    • 1992
  • This study was done to identify the association between serum copper and zinc levels and the cirrhosis and hepatocellular carcinoma(HCC), and to evaluate its diagnostic value on liver diseases. Sixty-three healthy persons, 60 patients with cirrhosis and 33 patients with hepatocellular carcinoma were rendomly selected and investigated for their general characteristics from October 1990 to August 1991. For analysis of the biochemical markers in liver function test and the serum copper and zinc levels, their fasting venous blood were sampled at 9:00 to 11:00 in the morning and centrifuged to separate the serum within one hour. All the samples were immediately analysed for biochemical markers and stored at $-20^{\circ}C$ in polypropylene tubes further copper and zinc analysis. Mean of serum coppper levels was $91.97{\pm}4.76{\mu}g/dl$ in control, $106.21{\pm}2.73{\mu}g/dl$ in cirrhosis and $127.05{\pm}0.77{\mu}g/dl$ in HCC. The value of HCC was statistically significantly higher than that of the control and cirrhosis(p<0.05). Serum zinc levels were $110.82{\pm}7.24{\mu}g/dl$ in control, $68.10{\pm}5.43{\mu}g/dl$ in cirrhosis and $63.78{\pm}2.20{\mu}g/dl$ in HCC. The values of cirrhosis and HCC were statistically significantly lower than that of control(p<0.05). The Cu/Zn ratio was statiatically significantly different among three groups(p<0.05). Test total protein, albumin, ALP and total bilirubin of biochemical markers of liver function were statistically significantly different among three groups(p<0.05). Differences between cirrhosis and HCC for ALT and AST, and between the control and HCC for direct bilirubin were not statistically significant. Biochemical markers statistically significantly correlated with serum copper and zinc levels and Cu/Zn ratio(p<0.05), were variable in three groups. In multiple logistic regression, odds ratio of serum copper level and Cu/Zn ratio had no statistical significance on the cirrhosis and the HCC, but that of serum sinc was statistically significant as 0.951 and 0.952(p<0.05). Serum copper and zinc levels and Cu/Zn ratio were not statistically significantly different between the cirrhosis and HCC. H\Albumin, ALP, zinc, total bilirubin and age among all variables were selected as main variables for three-group discriminant analysis. Percentage of 'grouped' cases correctly classified by these five variables was 98.4 for control, 73.4 for cirrhosis, 75.7 for HCC and 84.0 for all subjects. This study suggests that zinc level is considered to play a role as diagnostic marker on the hepatic disorders and be more useful than serum copper level and Cu/Zn ratio in diagnosis of the liver diseases.

  • PDF

Clinical Presentation of the Patients with Non-traumatic Chest Pain in Emergency Department (응급의료센터에 내원한 비외상성 흉통환자의 임상 양상)

  • Chung, Jun-Young;Lee, Sam-Beom;Do, Byung-Soo;Park, Jong-Seon;Shin, Dong-Gu;Kim, Young-Jo
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.283-295
    • /
    • 1999
  • Background: Patients with acute non-traumatic chest pain are among the most challenging patients for care by emergency physicians, so the correct diagnosis and triage of patients with chest pain in the emergency department(ED) becomes important. To avoid discharging patients with acute myocardial infarction(AMI) without medical care, most emergency physicians attempt to admit almost all patients with acute chest pain and order many laboratory tests for the patients. But in practice, many patients with non-cardiac pain can be discharged with simple tests and treatment. These patients occupy expensive intensive care beds, substantially increasing financial cost and time of stay at ED for the diagnosis and treatment of myocardial ischemia and AMI. Despite vigorous efforts to identify patients with ischemic heart disease, approximately 2% to 5% of patients presented to the ED with AMI and chest pain are inadvertently discharged. If the cause for the chest pain is known, rapid and accurate diagnosis can be implemented, preventing wastes in time and money and inadvertent discharge. Methods and Results: The medical records of 488 patients from Jan. 1 to Dec. 31, 1997 were reviewed. There were 320(angina pectoris 140, AMI 128) cases of cardiac diseases, and 168(atypical chest pain 56, pneumothorax 47) cases of non-cardiac diseases. The number of associated symptoms were $1.1{\pm}0.9$ in non-cardiac diseases, $1.4{\pm}1.1$ in cardiac diseases and $1.7{\pm}1.1$ in AMI(p<0.05). In laboratory finding the sensitivity of electrocardiography(EKG) was 96.1%, while the sensitivity of myoglobin test ranked 45.1%. Admission rate was 71.6% in for cardiac diseases and 50.6% for non-cardiac diseases(p<0.01). Mortality rate was 8.8% in all cases, 13.8% in cardiac diseases, 0.6% in non-cardiac diseases, and 28.1% especially in AMI. Conclusion: In conclusion, all emergency physicians should have thorough knowledge of the clinical characteristics of the diseases which cause non-traumatic chest pain, because a patient with any of these life-threatening diseases would require immediate treatment. Detailed history on the patient should be taken and physical examination performed. Then, the most simple diagnostic approach should be used to make an early diagnosis and to provide treatment.

  • PDF

Prediction of Life Expectancy for Terminally Ill Cancer Patients Based on Clinical Parameters (말기 암 환자에서 임상변수를 이용한 생존 기간 예측)

  • Yeom, Chang-Hwan;Choi, Youn-Seon;Hong, Young-Seon;Park, Yong-Gyu;Lee, Hye-Ree
    • Journal of Hospice and Palliative Care
    • /
    • v.5 no.2
    • /
    • pp.111-124
    • /
    • 2002
  • Purpose : Although the average life expectancy has increased due to advances in medicine, mortality due to cancer is on an increasing trend. Consequently, the number of terminally ill cancer patients is also on the rise. Predicting the survival period is an important issue in the treatment of terminally ill cancer patients since the choice of treatment would vary significantly by the patents, their families, and physicians according to the expected survival. Therefore, we investigated the prognostic factors for increased mortality risk in terminally ill cancer patients to help treat these patients by predicting the survival period. Methods : We investigated 31 clinical parameters in 157 terminally ill cancer patients admitted to in the Department of Family Medicine, National Health Insurance Corporation Ilsan Hospital between July 1, 2000 and August 31, 2001. We confirmed the patients' survival as of October 31, 2001 based on medical records and personal data. The survival rates and median survival times were estimated by the Kaplan-Meier method and Log-rank test was used to compare the differences between the survival rates according to each clinical parameter. Cox's proportional hazard model was used to determine the most predictive subset from the prognostic factors among many clinical parameters which affect the risk of death. We predicted the mean, median, the first quartile value and third quartile value of the expected lifetimes by Weibull proportional hazard regression model. Results : Out of 157 patients, 79 were male (50.3%). The mean age was $65.1{\pm}13.0$ years in males and was $64.3{\pm}13.7$ years in females. The most prevalent cancer was gastric cancer (36 patients, 22.9%), followed by lung cancer (27, 17.2%), and cervical cancer (20, 12.7%). The survival time decreased with to the following factors; mental change, anorexia, hypotension, poor performance status, leukocytosis, neutrophilia, elevated serum creatinine level, hypoalbuminemia, hyperbilirubinemia, elevated SGPT, prolonged prothrombin time (PT), prolonged activated partial thromboplastin time (aPTT), hyponatremia, and hyperkalemia. Among these factors, poor performance status, neutrophilia, prolonged PT and aPTT were significant prognostic factors of death risk in these patients according to the results of Cox's proportional hazard model. We predicted that the median life expectancy was 3.0 days when all of the above 4 factors were present, $5.7{\sim}8.2$ days when 3 of these 4 factors were present, $11.4{\sim}20.0$ days when 2 of the 4 were present, and $27.9{\sim}40.0$ when 1 of the 4 was present, and 77 days when none of these 4 factors were present. Conclusions : In terminally ill cancer patients, we found that the prognostic factors related to reduced survival time were poor performance status, neutrophilia, prolonged PT and prolonged am. The four prognostic factors enabled the prediction of life expectancy in terminally ill cancer patients.

  • PDF

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

Application of MicroPACS Using the Open Source (Open Source를 이용한 MicroPACS의 구성과 활용)

  • You, Yeon-Wook;Kim, Yong-Keun;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Tae-Sung;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: Recently, most hospitals are introducing the PACS system and use of the system continues to expand. But small-scaled PACS called MicroPACS has already been in use through open source programs. The aim of this study is to prove utility of operating a MicroPACS, as a substitute back-up device for conventional storage media like CDs and DVDs, in addition to the full-PACS already in use. This study contains the way of setting up a MicroPACS with open source programs and assessment of its storage capability, stability, compatibility and performance of operations such as "retrieve", "query". Materials and Methods: 1. To start with, we searched open source software to correspond with the following standards to establish MicroPACS, (1) It must be available in Windows Operating System. (2) It must be free ware. (3) It must be compatible with PET/CT scanner. (4) It must be easy to use. (5) It must not be limited of storage capacity. (6) It must have DICOM supporting. 2. (1) To evaluate availability of data storage, we compared the time spent to back up data in the open source software with the optical discs (CDs and DVD-RAMs), and we also compared the time needed to retrieve data with the system and with optical discs respectively. (2) To estimate work efficiency, we measured the time spent to find data in CDs, DVD-RAMs and MicroPACS. 7 technologists participated in this study. 3. In order to evaluate stability of the software, we examined whether there is a data loss during the system is maintained for a year. Comparison object; How many errors occurred in randomly selected data of 500 CDs. Result: 1. We chose the Conquest DICOM Server among 11 open source software used MySQL as a database management system. 2. (1) Comparison of back up and retrieval time (min) showed the result of the following: DVD-RAM (5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. (2) The wasted time (sec) to find some data is as follows: CD ($156{\pm}46$), DVD-RAM ($115{\pm}21$) and Conquest DICOM Server ($13{\pm}6$). 3. There was no data loss (0%) for a year and it was stored 12741 PET/CT studies in 1.81 TB memory. In case of CDs, On the other hand, 14 errors among 500 CDs (2.8%) is generated. Conclusions: We found that MicroPACS could be set up with the open source software and its performance was excellent. The system built with open source proved more efficient and more robust than back-up process using CDs or DVD-RAMs. We believe that the operation of the MicroPACS would be effective data storage device as long as its operators develop and systematize it.

  • PDF