Comparison of pollutant removal efficiency according to the locations of the supply and exhaust (격리병실내 급배기구 위치에 따른 오염물 제거효율 비교)

  • Won, An-Na
    • Journal of Urban Science
    • /
    • v.9 no.2
    • /
    • pp.13-20
    • /
    • 2020
  • The Recently, several countries have been affected by respiratory diseases, resulting in renewed research interest in their prevention and control. One such example was the 2015 outbreak of Middle East Respiratory Syndrome (MERS) in South Korea and COVID-19. In this study, we performed experiments and simulations based on concentration decay using CO2 as the tracer gas to elucidate the pollutant-removal efficiency for different inlet and exhaust locations and outdoor air-supply ratios. The wall inlet exhibited a higher pollutant-removal efficiency, owing to the upward movement of the air from the lower zone to the upper one. In conclusion, it is recommended that a total air-conditioning plan for isolation rooms be established as well as efficient system operation for pollutant removal and air-flow control to prevent the transmission of infections from the patients to others.

The Effectiveness of Environmental Management through Environmental Surveillance (환경감시를 통한 환경관리의 효과)

  • Mi Hyang Lee;Jae Yeun Kim;Sang Ha Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.557-561
    • /
    • 2023
  • This study aims to assess how effective environmental management can be accomplished through monitoring of environmental conditions in patient discharge rooms within healthcare facilities through direct observation and the use of fluorescent markers. From March to July 2013, this study evaluated 448 check-out beds in wards and intensive care units before and 494 after intensive environmental monitoring activities. The collected data were analyzed using the SPSS 21.0 program. According to the study's findings, direct observation increased from 95.2% prior to the implementation of intensive environmental monitoring activities to 98.9% following the implementation, which was statistically significant. The non-detection rate of fluorescent markers exhibited an increase from 96.1% prior to the commencement of intensive environmental monitoring activities to 98.0% following their implementation. However, it should be noted that this observed increase was not deemed statistically significant. In light of the results of this research, it is imperative to evaluate the effectiveness of environmental management by employing a variety of assessment methods, including direct observation and fluorescent markers.

Modeling Residual Chlorine and THMs in Water Distribution System (배급수계통에서 잔류염소 및 THMs 분포 예측에 관한 연구)

  • Ahn, Jae-Chan;Lee, Su-Won;Rho, Bang-Sik;Choi, Young-Jun;Choi, Jae-Ho;Kim, Hyo-Il;Park, Tae-Jun;Park, Chang-Min;Park, Hyeon;Koo, Ja-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.706-714
    • /
    • 2007
  • This study suggested a method for prediction of residual chlorine and THMs in water distribution system by measurement of residual chlorine, THMs, and other parameters, estimation of chlorine decay coefficients and THM formation coefficients, and simulation of water qualities using pipe network analysis. Bulk decay coefficients of parallel first-order were obtained by bottle tests, and pipe wall decay coefficients of first-order were estimated through evaluation of 5 models, which showed the lowest values of 0.03 for MAE(mean absolute error) and 0.037 MAE in comparison with the observed in field. And bottle tests were conducted to model first-order reaction of THM formation by nonlinear least square regression and the resultant coefficients were compared with the observed in field. As a result, the coefficients of determination$(R^2)$ for the observed and the predicted values were 0.98 in September and 0.82 in November, and the formation of THMs was predicted by modeling.

Style-Generative Adversarial Networks for Data Augmentation of Human Images at Homecare Environments (조호환경 내 사람 이미지 데이터 증강을 위한 Style-Generative Adversarial Networks 기법)

  • Park, Changjoon;Kim, Beomjun;Kim, Inki;Gwak, Jeonghwan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.565-567
    • /
    • 2022
  • 질병을 앓고 있는 환자는 상태에 따라 병실, 주거지, 요양원 등 조호환경 내 생활 시 의료 인력의 지속적인 추적 및 관찰을 통해 신체에 이상이 생긴 경우 이를 감지하고, 신속하게 조치할 수 있도록 해야 한다. 의료 인력이 직접 환자를 확인하는 방법은 의료 인력의 반복적인 노동이 요구되며 실시간으로 환자를 확인해야 한다는 특성상 의료 인력이 상주해야 하기에 이는 곧, 의료 인력의 부족과 낭비로 이어진다. 해당 문제 해결을 위해 의료 인력을 대신하여 조호환경 내 환자의 상태를 실시간으로 모니터링할 수 있는 딥러닝 모델들이 연구되고 있다. 딥러닝 모델은 데이터의 수가 많을수록 강인한 모델을 설계할 수 있으며, 데이터셋의 배경, 객체의 특징 분포 등 다양한 조건에 영향을 받기 때문에 학습에 필요한 도메인을 가지는 많은 양의 전처리된 데이터를 수집해야 한다. 따라서, 조호환경 내 환자에 대한 데이터셋이 필요하지만, 공개된 데이터셋의 경우 양이 매우 적으며 이를 반전, 회전기법 등을이용할 경우 데이터의 수를 늘릴 수 있지만, 같은 분포의 특징을 가지는 데이터가 생성되기에 데이터 증강 기법을 단순하게 적용하면 딥러닝 모델의 과적합을 야기한다. 또한, 조호환경 내 이미지 데이터셋은 얼굴 노출과 같은 개인정보가 포함 될 수 있으며 이를 보호하기 위해 정보들을 비식별화 해야 한다는 문제점이 있다. 따라서 본 논문에서는 조호환경에서 수집된 데이터 증강을 위한 Style-Generative Adversarial Networks 기법을 적용하여 조호환경 데이터셋 수집에 효과적인 증강 기법을 제안한다.

Camera Control based on Wireless Mobile and Web Environment (무선 모바일과 웹 환경 기반의 카메라 제어)

  • Seo, Jung-Hee;Park, Hung-Bog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.677-680
    • /
    • 2008
  • Miniaturization of equipments which have wireless network function and sensor have changed utilization method of computer in daily life, and have contributed to development for ubiquitous computing environment. In this paper, we design camera control system based wireless mobile and web-environmental through which nurse, doctor and family of patient can share and observe the information on condition of patient in hospital. Besides, this camera control system makes it possible to integrate diverse equipments of hospital into one system, and to conduct remote control function which can be applied to the patient control system. It is impossible to control shooting direction of camera apparatus in a remote area for observing patient in a hospital room through general web camera. So in this paper, we showed new design; we attached step motor which can rotate 360 degrees to web camera, and the step motor can operate through control board. Besides, we developed application for two environments, mobile and web-based environment, which enables us to offer proper efficiency in accordance with condition of observer through observation of control and collected image data.

  • PDF

Construction of Multi-agent-based Distributed Framework for Application Services of u-Hospital Information Systems (u-병원 정보 시스템의 응용 서비스를 위한 멀티에이전트 기반 분산 프레임워크 구축)

  • Jeong, Chang-Won;Shin, Chang-Sun;Joo, Su-Chong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.11
    • /
    • pp.861-865
    • /
    • 2009
  • As the hospital environment has been increasingly changed into a ubiquitous environment, the application services for the hospital environment are also faced with new requirements. In particular, the emergence of various mobile devices and the introduction of a wireless sensor network technology have accelerated the realization of the u-healthcare. The multi-agent paradigm has been introduced for satisfying both the integration of information and the various application scenarios established from various environments. This paper describes the software structure and u-applications for u-hospital information system based on ubiquitous environments. And it suggested the construction of a multi agent based distributed framework for supporting u-hospital information system. The suggested framework includes the JADE and distributed object group framework. And it implemented u-application services for supporting doctors and nurses, which provides the patient's health information and ward environment information. Especially, it is using a dynamic security mechanism on the security situation, which has not been emphasized in existing researches, and this paper shows the results for each user through the GUI.

Hospital Room Environment Monitoring System based on Wireless Communication (무선통신에 기반한 병실 환경 모니터링 시스템)

  • Lee, Seung-Chul;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.28-30
    • /
    • 2022
  • Recently, the number of confirmed cases has increased again with the new variant of COVID-19. Quarantine is recommended, especially to prevent the rapidly increasing spread, as environmental controls, such as minimizing contact with others, can increase safety. In addition, there are often cases in which the patient's condition cannot be confirmed from the standpoint of a guardian, such as visitation being prohibited under certain conditions. At this time, the sensor data values of oxygen, carbon dioxide concentrations, temperature and humidity, and alcohol, which are medical gases used in hospitals, are collected remotely using ZigBee wireless communication technology. Design a system that can be stored and monitored in a database. We propose an environmental monitoring system, which is a visualization system designed to allow hospitals to check and feedback data on the managed environment, and to give reliability to parents.

  • PDF

Comparative Study on the Infection Rates of Protected Environment versus Non-Protected Environment in Acute Myeloid Leukemia during Remission Induction Chemotherapy (급성 백혈병 환자에서 관해 유도 치료 시 일반 병실과 보호된 환경의 감염률 비교)

  • Sohn, Se-Hoon;Lee, Ha-Young;Kim, Dong-Geun;Park, Sung-Woo;Kim, Myung-Jin;Oh, Myung-Jin;Woo, Hye-Deok;Ryoo, Hun-Mo;Bae, Sung-Hwa;Lee, Kyung-Hee;Kim, Min-Kyoung;Hyun, Myung-Soo
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.113-121
    • /
    • 2010
  • Background and purpose : Patients with acute leukemia experience prolonged periods of neutropenia due to their disease or its treatment. For this reason, they often develop serious infectious complications. Although antibiotic therapy has improved in recent years, the fatality rate from infection remains high. For the control of infection, protected environment was developed. But because of economic issue, most of chemotherapy with acute myeloid leukemia have conducted in non-protected environment. So this study compared the rate of complete remission, days with neutropenia, rate of fever, rate of positive culture, rate of overt infection and use of antibacterial and antifungal agents with patients within non-protected environment and protected environment, retrospectively, Patients with acute myeloid leukemia during first remission induction chemotherapy were eligible for this study, Methods : Retrospective analysis was conducted between patients in non-protected (25 patients) and protected environment (14 patients) with acute myeloid leukemia during remission induction chemotherapy Results : Rate of overt infection, rate of fever, rate of positive culture and rate of use of antibiotics were significantly high in patients within non-protected environment compared with patients within protected environment. There were no differences in rate of complete remission and days of neutropenia Conclusions : This study suggests protected environment for patients with acute myeloid leukemia during remission induction chemotherapy could reduce rate of overt infection, and rate of use of antibiotics.

  • PDF

Computerization of Radiation Oncology Practice Using Order-Communicating System (처방전달 시스템을 이용한 방사선종양학과 진료업무의 전산화)

  • Shin, Sei-One;Yei, Ji-Won
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.97-109
    • /
    • 1996
  • Recently there has been attempts to develop hospital information system including order communicating system, patient tracing system, tumor registry system, office automation system and picture archiving and communication system(PACS). The authors devloped a practical system that was operated via order communication system of Yeungnam University Hospital. The system provided us the speed, accuracy, reliability, retention, economy and wide applicability through practical test. So we believed that this system would be one of standard computerized programs in radiation oncology practice and providing widely usable data for clinical statistics, medical record, tumor registry system and clinical researches.

  • PDF

A Study on Microbial Pollution of Indoor Air at Elderly Care Facilities (노인요양시설(老人療養施設)의 실내공기(室內空氣) 중 미생물(微生物) 오염(汚染)에 관(關)한 연구(硏究))

  • Kim, Sang-Ha;Kim, Young-Kwon
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.583-586
    • /
    • 2009
  • 우리나라에서의 실내공기 중 미생물에 대한 연구는 사무실, 유치원, 극장, 도서관등 다중이용시설과 병실 내 공간에 존재하는 곰팡이를 비롯한 오염 미생물 수에 대한 조사가 이루어지고 있으나 노인요양시설을 대상으로 한 바이오에어로졸이 포함되어 있는 미생물의 종류에 대한 연구는 아직 미비한 실정이다. 따라서 본 조사에서는 1개 광역도 1개 도농복합도시 지역의 노인요양시설을 대상으로 실내 미생물 오염상태가 건강에 미치는 영향과 적절한 실내 환경유지를 위한 미생물 오염 방지 및 개선방안에 대한 기초자료를 제공하고자 노인요양시설의 실내 미생물의 오염실태를 조사하였다. 2007년 4월 1일부터 5월 31일까지 2개월 동안 1개 광역도 1개 도농복합도시 지역의 노인요양시설 5곳을 대상으로 실내 외의 공기 중 바이오에어로졸 조사하기 위해 관성충돌 채취법을 적용한 미생물 채취기인 air IDEALTM(Biomerieux)를 이용하여 면양혈액한천배지와 Sabouraud Dextrose Ager를 사용하여 채취하여 배양하였다. 배양하여 분리 동정한 결과 다음과 같은 결론을 얻었다. 1. 각 시설별 전체 미생물의 분리는 300 L 실내에서 S 요양원이 263 cfu/m3로 가장 많았고, U 요양원이 123 cfu/m3로 가장 낮은 수가 분리되었다. 진균의 수는 300 L 실내에서 G 요양원이 73 cfu/m3로 가장 많았으며, C 요양원은 40 cfu/m3로 가장 낮은 비율로 분리되었다.

  • PDF