• Title/Summary/Keyword: 변형온도

Search Result 1,224, Processing Time 0.03 seconds

Critical Buckling Temperatures of Anisotropic Laminated Composite Plates considering a Higher-order Shear Deformation (고차전단변형을 고려한 비등방성 적층복합판의 임계좌굴온도)

  • Han, Seong Cheon;Yoon, Seok Ho;Chang, Suk Yoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.201-209
    • /
    • 1998
  • The presence of elevated temperature can alter significantly the structural response of fibre-reinforced laminated composites. A thermal environment causes degradation in both strength and constitutive properties, particularly in the case of fibre-reinforced polymeric composites. Furthermore, associated thermal expansion, either alone or in combination with mechanically induced deformation, can result in buckling, large deflections, and excessively high stress levels. Consequently, it is often imperative to consider environmental effects in the analysis and design of laminated systems. Exact analytical solutions of higher-order shear deformation theory is developed to study the thermal buckling of cross-ply and antisymmetric angle-ply rectangular plates. The buckling behavior of moderately thick cross-ply and antisymmetric angle-ply laminates that are simply supported and subject to a uniform temperature rise is analyzed. Numerical results are presented for fiber-reinforced laminates and show the effects of ply orientation, number of layers, plate thickness, and aspects ratio on the critical buckling temperature and compared with those obtained using the classical and first-order shear deformation theory.

  • PDF

Hot ductility behavior of steel as low cycle high temperature fatigue (저주기 고온 피로에 따른 강의 열간 연성 거동)

  • 박병호;김현정;손광석;김동규
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.86-86
    • /
    • 2003
  • 주편은 1차 냉각 지역인 수냉 몰드를 통과한 후, 2차 냉각 지역에서 guide roll, pinch roll 그리고 driven roll등에 의해 반복적인 압축하중을 받고 있으며, roll과 roll사이에서는 철정압에 의한 주편 bulging 현상이 발생하고 주편의 표면은 인장응력을 받게 된다. 특히 연속주조 중 주편의 변형기구가 단순 탄소성 변형 이 아닌 creep에 의한 변형임을 고려할 때, 2차 냉각 지역에서 주편의 표면은 전술한 압축 및 인장변형 이 반복되는 저주기 고온 피로 환경을 거침을 알 수 있다. 본 연구에서는 탄소함량에 따른 주편의 bulging시의 크랙 발생에 미치는 저주기 고온 피로의 효과를 조사하였다. 또한, 용체화 처리 온도에서 시험 온도까지의 냉각 속도의 영향을 조사하기 위하여 1$^{\circ}C$/s 및 1$0^{\circ}C$/s로 냉각 속도를 변화시켜 열간 연성 곡선을 작성하였다. 본 연구에서 얻어진 결과는 다음과 같다. 저탄소강의 경우는 저주기 피로의 영향이 관찰되지 않았으며, 중탄소강의 경우, 저온에서는 저주기 피로로 인해 열간 연성이 증가하였으나, 고온에서는 변형유기 페라이트의 생성으로 인해 열간 연성 이 감소하였다. 고탄소강의 경우는 저주기 피로로 인하여 열간 연성이 모든 온도 구간에서 증가하였다. 또한 용체화 처리후 시험 온도까지의 냉각 속도가 감소함에 따라 열간 연성이 증가하였는데, 이는 입 계 석출물의 조대화로 인해 열간 연성이 증가하는 것으로 판단된다.

  • PDF

superplastic deformation conditions of $YBa_{2}Cu_{3}O_{7-x}$ superconducting materials ($YBa_{2}Cu_{3}O_{7-x}$ 계 초전도체의 초소성 변형조건)

  • Kim, Byeong-Cheol;Jo, Beom-Rae;Song, Jin-Tae
    • Korean Journal of Materials Research
    • /
    • v.5 no.3
    • /
    • pp.371-378
    • /
    • 1995
  • YBCO 산화물 초전도체의 초소성 변형에 대한 최적 변형조건을 파악하고자 80$0^{\circ}C$~93$0^{\circ}C$의 온도범위에서 1.0 $\times$ $10^{-3}$s^{-1}$!1.0 $\times$ $10^{-7}$s^{-1}$의 초기변형속도로 압축시험을 수행하였다. 변형속도 민감지수는 m=0.50 $\pm$ 0.1로 나타났다. 이는 결정립계 미끄러지\ulcornerㄹ 주 변형기구로 하는 초소성임을 의미한다. 결정립크기에 따른 유동응력과의 관계는 $\sigma$\propto$d^{1.8 $\pm$ 0.3}$의 지수함수식을 이루고 있으며 Nabarro-Hering 크\ulcorner과 상응하는 격자확산이 확산경로임을 보였다. 초소성 변형에 대한 활성화에너지는 Q=571 $\pm$ 30 kJ/mole이었다. 본 실험온도 구간에서 압축 변형시 변형속도, 변형응력 및 결정립크기에 따른 고온 변형거동 관계식은 $\varepsilon$=A$\sigma$^{2.00 $\pm$ 0.04 - 1.8 $\pm$ 0.3}$ exp(-571 $\pm$ 30kJ/RT)와 같이 유도 되었다. 본 실험조건에서 최적 초소성 변형조건은 86$0^{\circ}C$ 부금, 초기변형속도 ~1.0 $\times$ $10^{-4}$S^{-1}$이었다.

  • PDF

A Study on the Evaluation of Thermal Stress of Massive Concrete Structure (매스콘크리트구조물의 온도응력평가에 관한 연구)

  • 강석화;정철헌;정한중;이용호;박칠림
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.2
    • /
    • pp.126-135
    • /
    • 1995
  • Thermal cracks are occured when thermal stress due to the hydration of cement exceeds the tens~le strength of concrete. Since crackmg causes poor durability of concrete, the effect of ther ma1 cracking should be includod for the design and construction of massive concrete structures. In this study, an experiment is performed for the investigation of time dependent thermal stress history. In order to evaluate thermal stress. two methods are employed. One 1s the evaluation method of thermal stress based on the measurement from embedment stram gauge with non-stress strain gauge and the other 1s based on the measurement from concrete stress gauge. As a result of this study, the value corrected by the former shows good agreement with the latter. The validity of the proposed method for the evaluation of thermal stress 1s explored.

Evaluation of Rutting Resistance of Modified Asphalt Concrete by Accelerated Pavement Testing (포장가속시험을 통한 개질아스팔트 혼합물의 소성변형 저항성 평가 연구)

  • Kim, Jun Hyung;Suh, Young Chan;Kwon, Soo Ahn;Cho, Yong Ju
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2D
    • /
    • pp.285-292
    • /
    • 2006
  • The objective of this study is to introduce the development of the first Korean full-scale APT(Accelerated Pavement Tester) and to compare the performances of general dense grade asphalt mixture and modified asphalt mixtures as the first running of the tester. The tests evaluated the rutting resistance for dense grade mixture and three different modified asphalt mixture under three different temperature conditions (25-30, 40, $50^{\circ}C$). The results of the testing were compared with the laboratory test results. Results of the tests indicated that the all the modified asphalt sections showed higher rutting resistance than the dense grade section. Especially, the difference was more noticeable at higher temperature condition. Additionally, $G^*/sin{\delta}$ is found out to be an important factor for permanent deformation prediction whereas the resilient modulus was not.

Papers : Simultaneous Monitoring of Strain and Temperature During and After Cure of Unsymmetric Cross - ply Composite Laminate Using Fiber Optic Sensors (논문 : 비대칭 직교적층 복합재료 적층판의 성형시 및 성형후 광섬유 센서를 이용한 변형률 및 온도의 동시 모니터링)

  • Gang,Hyeon-Gyu;Gang,Dong-Hun;Hong,Chang-Seon;Kim,Cheon-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.49-55
    • /
    • 2002
  • In this paper, we present the simulation monitoring of strain and temperature during and after the cure of unsymmetric composite laminate using fiber optic sensors. Fiber Bragg grating/extrinsic Fabry-Perot interferometric (FBG/EFPI) hybrid sensors are used to measure those measurands. The characteristic matrix of the sensor is analytically derived and measurements can be done without sensor calibration. A wavelength-swept fiber laser is utilised as a lighr source. Two FBG/EFPI sensors are embedded in a graphite/epoxy unsymmetric cross-ply composite laminate in different directions and different locations. We perform a real time monitoring of fabrication strains and temperatures at two points of the composite laminate during cure process in an autoclave. Also, the thermal strains and temperatures of the fabricated laminate are measured in a thermal chamber. Through these experiments, we can provide a basis for the efficient smart processing of composite and know the thermal behavior of unsymmetric cross-ply composite laminate.

Design of Flexure Mounts for Satellite Primary Mirrors (인공위성 주반사경의 플렉셔 마운트 설계)

  • 엄태경;박강수;조지현;이완술;이준호;윤성기;이응식;우선희;이승훈
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.138-139
    • /
    • 2003
  • 반사경을 지지하는 데에 있어서의 기계적, 열적 변형이 광학 부품에 미치는 영향을 최소화 하도록 광학 요소를 이러한 영향으로부터 차단하는 기계 장치를 플렉셔(flexure)라고 한다. 기계적 영향은 중력, 관성, 진동에 의한 하중 및 조립 시의 오차에 의한 응력 등에 의해 발생하는 변형을 말한다. 또한 열적 영향은 열적 평형 상태와 과도 상태 하에서 주위 환경의 온도변화에 의한 변형을 말한다. 예를 들어 작은 열팽창 계수를 가진 반사경 또는 렌즈와 큰 열팽창 계수를 갖는 지지구조가 어떤 온도 하에서 조립된 후 처음 온도와 다른 온도에 놓이는 경우를 생각해 보자. (중략)

  • PDF

Thermal Stress Analysis for the Heat of Hydration Considering Creep and Shrinkage Effects in Mass Concrete (크리이프와 건주수축영향을 고려한 매스콘크리트에서의 수화열에 대한 온도응력해석)

  • 김진근;김국한
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.3
    • /
    • pp.101-111
    • /
    • 1992
  • 매스콘크리트 구조물에서의 시멘트 수화열은 구조물의 균열을 발생시킬 만큼 큰 내부온도를 발생시킨다. 따라서 매스콘크리트 구조물에서의 설계와 시공단계에서 내부온도응력을 예측할 수 있다면 이와같은 균열로 인한 구조물의 피해를 예방할 수 있을 것이다. 그리고 수화열에 의한 온도증가는 타설초기에 발생하므로 크리이프에 의한 영향도 매우크다. 따라서 온도응력해석시 크리이프와 건조수축의 영향을 고려하는 것이 구조물의 안전성과 사용성을 정확히 파악하는데 필요하다. 본 연구는 먼저 매스콘크리트의 온도이력을 유한요소법에 의해 해석하고, 작용하중이나 온도이력을 크리이프와 건조수축영향을 고려하여 콘크리트 구조물의 응력과 변형을 유한요소법에 의해 계산하였다. 본 연구에서 온도이력 계산과 콘크리트구조물의 응력과 변형의 계산을 위해 작성한 프로그램 결과를 실제 구조물의 실험결과와 비교하였을 때 양호한 결과를 얻었다.

Measurements of Thermal Gradient and Thermal Strain of Mortar Specimens Using Fiber Bragg Grating Sensor (광섬유 격자 센서를 이용한 모르타르시편의 온도구배 및 열 변형 측정)

  • Rhim, Hong-Chul;Lee, Eun-Joo;Chun, Heung-Jae;Park, Dong-Nyuck
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.133-138
    • /
    • 2003
  • As concrete structures are heated, thermal strain can be developed. Because of the boundary conditions, the thermal stress may be arisen. Thermal strain and temperature were measured simultaneously using an optical fiber sensor. Fiber Bragg Grating Sensor(FBG sensor) was used in the measurement. Because it can measure the strains more than two points with one line, it was possible to measure both thermal strain and temperature with one line. To compare data measured by FBG sensor, strain and temperature were measured using strain gauge and thermocouple. The FBG sensor could measure the strain under the temperature greater than $60^{\circ}C$ but strain gauge couldn't. Both the FBG temperature sensor and thermocouple could measure the temperature and the results are related each other linearly.

A Study on deformation and electrical efficiency of PV cell according to hot-air temperature at soldering process (솔더링 공정에서 열풍온도에 따른 PV셀의 변형량 및 전기효율에 관한 연구)

  • Lee, Jong-Hwan;Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4065-4071
    • /
    • 2014
  • The analysis results of the temperature distribution and deformation at the PV cell with a thickness of $200{\mu}m$ according to hot-air temperature at the soldering process of a PV cell and ribbon tend to agree somewhat with the experimental measured values. The best result of the electrical efficiency appears in the module soldered at a hot-air temperature of $390^{\circ}C$. An analysis of the soldering PV cell with a thickness of $150{\mu}m$ at a hot-air temperature of $350^{\circ}C$ confirmed that the maximum deformation was approximately 5.9mm. As the temperature of hot air is set to decrease, the deformation is reduced and it is predicted that the electrical efficiency can be improved.