Search Result 319, Processing Time 0.033 seconds

A Study on the Design Standard of Demand Factor and Load Characteristics in Underground Streets (지하상가시설의 부하특성과 수용률 기준설정에 관한 연구)

  • 김세동
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.4
    • /
    • pp.62-67
    • /
    • 1996
  • 본 연구는 국내 지하상가시설의 설비구성 및 가동특성을 고려한 전기설비현황 및 전력사용부하 특성을 실측, 조사하여 변전시설용량의 합리적 설계를 위한 부하종별 수용률 기준을 설정하여 제시한다.

  • PDF

Diagnosis of power supply by analysis of chaotic nonlinear dynamics (카오스 비선형 동력학 해석에 의한 수·변전설비의 진단)

  • Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.1
    • /
    • pp.113-119
    • /
    • 2013
  • In this paper, n order to degrade of diagnosis of power supply by using Poincare map and fractal dimension with temperature measured by infrared camera. we review the characteristic of temperature variation according to pattern variation of power supply in chemical industry complex. As a simulation results we can be realized the characteristic behaviors of nonlinear dynamics in the poincare mal and fractal dimension. In the future verification method requires through additional research.

A Study on Harmonic Analysis and Countermeasure at the High Speed Railway Substation (고속전철 변전소의 고조파 분석과 대책에 관한 연구)

  • 김재철;박수만;강창원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.138-143
    • /
    • 2004
  • This paper analyzed harmonics from high speed railway traction to high speed railway substation and provide a reduction method of harmonics using the passive filter. A substation supplies the electric power to a train or can supply the electric power to several trains. According to the number of trains covered by a substation, characteristics of harmonics are investigated. These harmonics affect transformer heating and inductive interference. In order to get rid of the damage from the harmonics, this paper presented minimizing method of harmonics. The proposed method is verified in simulation using the PSCAD/EMTDC.

Verification of The Buffered Report based Data Transmission Function of Substation Automation (변전자동화 버퍼방식의 데이터 전송 통신 기능 검증)

  • Lee, N.H.;Jang, B.T.;Lee, M.S.;An, Y.H.;Song, I.J.;Kim, B.H.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.227-229
    • /
    • 2009
  • IEC 61850 변전자동화시스템은 상위시스템과 다수의 IED 간에 서버와 클라이언트의 관계를 가지고 리포트 서비스를 통해 정보의 전달이 이루어지는 시스템이다. 규격에서 정의하는 리포트는 IED에 발생한 이벤트의 버퍼 저장 유무에 따라. Unbuffered Report와 Buffered Report로 나눈다. 본 논문은 변전자동화 시스템을 구축하는 데 있어서 상위운영시스템과 IED간 서버와 클라이언트의 네트워크 구성을 통해 데이터전송을 하는 방식인 Buffered Report의 성능을 검증하고자 Buffered Report Control Block의 설정과 전송된 리포트의 적합 여부를 판정할 수 있는 시험내용을 설명하고자 한다.

  • PDF

Diagnosis of power supply using time-series of infrared camera (열화상 카메라의 시계열 데이터를 이용한 수·변전설비의 진단)

  • Hwang, Suk-Seung;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1443-1447
    • /
    • 2012
  • In this paper, the characteristic of temperature variation was reviewed according to pattern variation. In order to degrade of diagnosis of power supply by using time series data for temperature measured by infrared camera it was transformed into 2 dimension phase plane using Takens embedding method. As a simulation results we cannot completely confirm the characteristic behaviors of nonlinear dynamics in phase plane. However these results has a certain patterns, it requires verification method through additional research in the future.

Development and Operation of Air Cooling System for 154kV Power Transformer (154kV 변압기 공냉형 수냉식 냉각설비 개발 및 운전)

  • Min, Byeong-Wook;Shin, Myoung-Sik;Cho, Hwan-Gu;Choi, Joon-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.932-933
    • /
    • 2011
  • 지속적인 경제발전 및 이상 기후변화 등으로 인한 전력수요의 지속적 증가로 2010년에 최대 66,511MW, 2011년에는 4월 현재까지 최대 68,154MW를 기록하고 있어 원활한 전력공급을 위한 전력설비의 지속적인 건설이 요구되고 있다. 그러나 건설지역 주민들의 민원 등으로 인해 건설은 갈수록 어려워지고 있는 실정이다. 한전에서는 변전소 건설의 경제성을 확보하고 변전소 건설 부지면적 및 건물면적을 최소화한 154kV Compact형 변전소를 개발하게 되었다. 이를 위해서는 변전소 면적의 상당부분을 차지하고 있는 변압기 설치면적 최소화가 필수적이다. 이를 위해 변압기 설치공간 최소화하고 냉각효율 및 민원 등을 고려한 냉매냉각방식(HCFC:Hydro Chloro Carbons, 수소화염화불화탄소)의 적용을 추진하였으나 HCFC는 오존파괴물질로 규정되어 생산과 수입이 규제될 예정으로 한전은 냉매냉각방식의 대안으로 기존 수냉식 냉각방식의 환경문제, 냉각탑 관리의 어려움 등과 물 비산에 따른 상하수도 이용요금 부담 등의 단점을 개선한 공냉형 수냉식 냉각방식을 개발하게 되었다. 본 논문에서는 154kV 변압기 공냉형 수냉식 냉각방식의 개발내용 및 운전현황에 대해 기술하고자 한다.

  • PDF

A Study on Development of Message Integration Bus for Supervisory Control And Data Acquisition (변전설비 감시제어시스템 메시지통합버스 개발에 관한 연구)

  • Oh, Do-Eun;Jung, Nam-Joon;Ko, Jong-Min;Song, Jae-Ju;Yang, Il-Kwon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.830-832
    • /
    • 2008
  • 변전설비 감시제어시스템은 그 목적상 실시간의 대규모 측정정보 취득을 목적으로 한다. 취득정보는 RTU(Remote Terminal Unit)를 통해서 감시제어시스템에 전달된 후 필요에 따라 해당 정보를 요청하는 애플리케이션들에게 다시 전송된다. 현재 감시제어시스템에 널리 사용되는 DNP(Distribute Network Protocol)는 취득포인트 정보와 취득값만 가지고 있으므로 포인트 리스트에 대한 정보가 없는 경우에는 취득한 데이터를 판독할 수 없다. 따라서 감시제어시스템을 구축하기 위해 우선 RTU에 감시 선로정보를 입력하고, 이 정보를 다시 감시제어시스템의 DB에 포인트 정보와 매핑을 수행해야만 한다. 또한, 새로운 애플리케이션에서 취득값을 얻기 위해서는 이들 포인트 정보와 매핑 정보를 가지고 있는 감시제어시스템의 DB에 직접 연결해야만 한다. 본 논문은 공통정보모델과 이를 기반으로 작성된 메시지 교환 표준 인터페이스를 이용하여 감시제어시스템 취득정보의 효과적인 교환이 가능한 메시지 통합버스에 대하여 기술한다.