• Title/Summary/Keyword: 변위 게이지

Search Result 48, Processing Time 0.034 seconds

Strain Analysis by Measured Displacement Data (측정 변위를 이용한 변형률 해석)

  • Kim, Tae Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.4
    • /
    • pp.147-155
    • /
    • 2002
  • To find the safety and serviceability of bridges, it must consider the behaviour of structural member and evaluation of the exact resistance of the member subjected to external loads. To evaluate the behaviour and the resistance of the structural member, it must measure the strains and displacements of the structures. Usually we use the strain gauge to measure the strains. When, the bridge is long span and high pier, the setting of strain gauge is very difficult and not economic. It is not recommendable for the use of strain gauge, when the structural member has many cracks and moisture. Thus, to make up for this demerits, the algorithm of strain analysis by measured displacements data is proposed.

Fatigue crack Propagation Rate and Crack Opening behavior in Weldment Observed by Laser ISDG Method (레이저간섭변위 게이지로 관찰한 용접재에서의 피로균열 열림거동과 피로균열 전파속도)

  • Song, Sam-Hong;Kim, Hyun;Choi, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.908-917
    • /
    • 1995
  • The constant .DELTA.K fatigue tests are performed in SS41 and its weldments to investigate crack opening behavior and fatigue crack propagation behavior at each parts of weldment and its boundary layer. The weldments were annealed after welding for the purpose of relieving residual stress. Every weldments has notch at weld metal zone, and fatigue crack propagates from weld metal zone to vase metal zone perpendicular to weld line. The Laser ISDG method is used in order to determine the crack opening ratio, this method is more precise than indirect measurement method, and faster and easier than other direct measurement method.

A Study on the Measurement and Application of Long Gauge fiber Brags Grating Sensors (긴 게이지 길이 광섬유 격자 센서의 측정과 응용)

  • Kim, Ki-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.343-349
    • /
    • 2005
  • In this research, the fiber Bragg grating sensors with long gauge for displacement measurement in the long distance is developed and tested. The sensors show an accuracy and a capability for displacement measurement oin long distance. Monitoring using static logger of system of FBG sensor with strained optical fiber shows the capability of measurement in the harsh environment such as strong wind. Measurement of long distance displacement by optical fiber sensor if use $250{\mu}m$ optical fiber and impose some strong pre-tension shows possibility in monitoring of nuclear containment structure.

Measurement of Thermal Expansion Coefficient of Poly-Si Thin Film Using Microgauge (마이크로 게이지를 이용한 다결정 샐리콘 박막의 열팽창 계수 측정)

  • Chae, Jeong-Heon;Lee, Jae-Yeol;Gang, Sang-Won
    • Korean Journal of Materials Research
    • /
    • v.8 no.1
    • /
    • pp.85-91
    • /
    • 1998
  • 인이 높은 농도로 도핑되어진 LPCVD 다결정 실리콘 박막의 열팽창 계수를 마이크로 게이지법을 이용하여 측정하였다. 기존의 박막의 열팽창 계수 측정 법에서는 박막이 기판에 증착되어진 상태에서 측정이 이루어지므로, 기판의 탄성계수와 열팽창계수를 미리 알고 있어야 한다. 이에 비해 마이크로 게이지법에서는 박막의 열\ulcorner창 계수를 도출하기 위하여 기판의 탄성계수 값과 열팽창 계수 값을 필요로 하지 않는다는 장점이 있다. 마이크로 게이지법에서는 전류를 가할 경우 줄 발열에 의해 발생한 마이크로 게이지에의 변위를 측정하고, 그 때 계산된 마이크로 게이지의 평균 온도의 관계에서 열팽창 계수를 계산한다. 다결정 실리콘 박막의 열팽창 계수는 2.9 x $10^{-6}$$^{\circ}C$로 측정되었으며, 이 값들의 표준편차는 0.24x$10^{-6}$$^{\circ}C$였다.

  • PDF

Study of Output Characteristics of Pressure T/D using Piezo Capacitor Type (Piezo-Capacitor방식 입력 Transducer와 출력특성 고찰)

  • Lee, Seong-Jae;Yoo, Byung-Ki
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.245-246
    • /
    • 2009
  • 정전용량형 후막 스트레인 게이지(piezocapacitive thick film strain gage)는 세라믹 ($Al_2O_3$)을 주 원료로 하는 지지대(약 5mm)와 다이어프램(약 $300{\mu}m$) 그리고 가드 링으로 구성된다. 전극 판은 도전성 페이스트를 이용하여 지지대와 다이어프램에 형성되었으며 극판 사이에는 유전체 메이스트를 사용하여 스크린 인쇄로 후막을 형성하였다. 극판 사이의 가드 링 두께는 약 $30{\mu}m$정도로 다이어프램의 변위 최대값을 유지시키는 데 필요한 간격이다. 따라서 정전용랑형 후막 스트레인 게이지는 지지대를 중심으로 다이어프램에 압력 (0.5~1.0bar)이 인가될 때 변위를 발생시키면서 커패시터 값이 압력의 크기에 따라 비례 특성을 가지고 변화하는 것을 이용한 것이다. 압력이 없을때 초기값은 35pF~40pF 정도이고 정격압력의 최대치를 인가시켰을 때 약 55pF~55p를 나타내었다.

  • PDF

Technique for the Measurement of Crack Widths at Notched / Unnotched Regions and Local Strains (콘크리트의 노치 및 비노치 구역에서의 균열폭 및 국부 변형률 정밀 측정기법)

  • Choi, Sok-Hwan;Lim, Bub-Mook;Oh, Chang-Kook;Joh, Chang-Bin
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.205-214
    • /
    • 2012
  • Crack widths play an important role in the serviceability limit state. When crack widths are controlled sufficiently, the reinforcement corrosion can be reduced using only existing concrete cover thickness due to low permeability in the region of finely distributed hair-cracks. Thus, the knowledge about the tensile crack opening is essential in designing more durable concrete structures. Therefore, numerous researches related to the topic have been performed. Nevertheless accurate measurement of a crack width is not a simple task due to several reasons such as unknown potential crack formation location and crack opening damaging strain gages. In order to overcome these difficulties and measure precise crack widths, a displacement measurement system was developed using digital image correlation. Accuracy calibration tests gave an average measurement error of 0.069 pixels and a standard deviation of 0.050 pixels. Direct tensile test was performed using ultra high performance concrete specimens. Crack widths at both notched and unnotched locations were measured and compared with clip-in gages at various loading steps to obtain crack opening profile. Tensile deformation characteristics of concrete were well visualized using displacement vectors and full-field displacement contour maps. The proposed technique made it possible to measure crack widths at arbitrary locations, which is difficult with conventional gages such as clip-in gages or displacement transducers.

Development of Horizontal Displacement Sensor for Rainfall-simulated Centrifugal Model Test (강우재현 원심모형실험에 적용하기 위한 수평변위 계측장치의 개발)

  • Lee, Chungwon;Park, Sungyong;Kim, Yongseong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.12
    • /
    • pp.71-77
    • /
    • 2014
  • Heavy rainfall induces many disasters including slope failure and infrastructure collapse. In this point of view, rainfall-simulated centrifugal model test can be a reasonable tool to evaluate the stability of geotechnical structure. In order to obtain the displacements of a model in centrifugal model test, in general, LVDT and laser displacement sensor are used. However, when the rainfall is simulated, the LVDT has the problem of excessive infiltration into the model ground, and the laser displacement sensor provides the measuring result with inaccuracy due to the dispersion of the laser radiation. Hence, in this study, horizontal displacement sensor for rainfall-simulated centrifugal model test was developed. This sensor produced with a thin elastic steel plate and gave the accurate relationship between the displacement and the strain.

Design of δ5 Clip Gage for CTOD Measurement (CTOD 측정용 δ5 Clip Gage 설계)

  • Park, Tai-Heoun;Nahm, Seung-Hoon;Kim, Am-Kee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.4
    • /
    • pp.343-351
    • /
    • 2004
  • The flaw assessment method based on ${delta}_5$ parameter was recently proposed and put to the practical use. However: since it is almost impossible to measure the ${delta}_5$ by the existing commercial clip gager, we need to develope the specially designed gages which are suitable for that purpose. In this research, a double cantilever type ${delta}_5$ clip gage with the traveling distance of 4mm was developed by the finite element analysis and the construction of Wheatstone bridge circuit including strain gages. The linearity of developed ${delta}_5$ clip gage was evaluated by the MTS extensometer calibrator with the proper adapters which allow the 6s clip gage to sit on the calibrator. Consequently, the 6s clip gage revealed the good linearity between the output voltage and the traveling distance of gage.

Sound Intensity Measurement in Near Field of Thin Plate Using Strain Gauge Bridge (스트레인 게이지 브리지를 이용한 얇은 평판의 근접장 음향 인텐시티 측정 방법론)

  • 김용조;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.71-76
    • /
    • 1996
  • 스트레인 게이지 브리지와 한개의 진동변위 탐촉자를 이용하여 평판의 근접장에서 음향 인텐시티를 측정하는 방법에 대하여 설명하였다. 또한 구조감쇠의 모델링을 통하여 음향방사파워에 대한 내부손실파워의 비를 나타내는 계수를 정의하여 내부손실파워의 정도를 평가하는 척도로 사용할 수 있음을 설명하였다. 임의의 경계조건을 가지는 평판에서 2개의 마이크로폰과 1개의 가속계를 이용하여 근사적으로 측정된 음향 인텐시티와 본고에서 제시한 방법으로 측정한 음향 인텐시티가 거의 일치함을 보이므로써 제시된 측정방법의 타당성을 검증하였다. 실험에 사용된 계(system)는 일반적인 해석에서 유체부하를 무시할 수 있는 계로 평판내부의 에너지 흐름에 비하여 외부로 방사되는 소음의 에너지 흐름이 매우 작기 때문에 평판내부의 에너지 흐름으로부터 방사되는 소음의 에너지 흐름을 알아내는 것이 매우 어려울 것으로 예상되었으나 본고에 제시된 방법으로 좋은 결과를 얻을 수 있었다. 앞으로 본 방법의 측정 오차에 대한 면밀한 고찰이 있어야 할 것이다. 그리고 평판의 내부손실이 비교적 큰 경우에 본 방법의 실험적으로 검증이 필요할 것이다. 또한 실질적인 문제에 응용되어 얼마만큼 유용한 정보를 제공할 것인가를 살펴보아야 할 것이다.

  • PDF

Load-Displacement Characteristics and Interactive Load Capacity Model for Metal Plate Connections in Wood (I) - Load-displacement characteristics - (목재(木材)-금속(金屬)플레이트 접합부(接合符)의 하중(荷重)-변위(變位) 특성(特性) 및 조합하중성능(組合荷重性能)에 대한 모형(模型) 분석(分析) (I) - 하중(荷重)-변위(變位) 특성(特性) -)

  • Park, Moon-Jae;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.21-27
    • /
    • 1995
  • 고도(高度)의 엔지니어링 구조물(構造物)로 경제성이 높은 경골(輕骨) 목조(木造) 트러스에 사용될 수 있는 소나무(Pinus densiflora) 재(材)에 적용한 20게이지 아연도금강(鋼) 플레이트 접합부(接合部)의 하중(荷重)-변위(變位) 특성(特性)을 평가하기 위하여 Foschi 모형을 사용하여 모형 모수(母數)를 산출하고 실험치와 계산치를 비교 분석하였다. 접합부(接合部)의 하중(荷重)-변위(變位) 곡선(曲線)은 비선형 특성을 나타내었다. 접합부의 하중성능 및 강성(剛性)은 플레이트 및 목리에 평행한 형태에서 최대치를 나타내었고, 플레이트에 직각이고 목리(木理)에 평행한 형태로부터 플레이트에 평행이고 목리에 직각인 형태순으로 감소하다 플레이트 및 목리에 직각인 형태에 최소치를 나타내었다. 3-모수(母數) 비선형 모형으로 예측된 스테인레스강(鋼) 및 아연도금강(鋼) 플레이트 접합부의 하중-변위 특성에 대한 계산치는 실험치와 잘 일치하였다.

  • PDF