• Title/Summary/Keyword: 벽면 이격거리

Search Result 9, Processing Time 0.023 seconds

A Study on the Optimal Installation of Ducted Fan Ventilation System in Long Mine Airways - Focused on the Wall Separation Distance and the Gap Length between Ducts (장대 광산갱도내 풍관 접속 통기선풍기 최적 설치 방안연구 - 벽면과 풍관간의 이격거리 중심으로)

  • Lee, Chang Woo;Nguyen, Van Duc
    • Tunnel and Underground Space
    • /
    • v.27 no.1
    • /
    • pp.12-25
    • /
    • 2017
  • In local underground mines heavily depending on the natural ventilation, ducted fan auxiliary ventilation system is strongly recommended instead of the total mine ventilation system requiring large capital and operating costs. Optimizing the installation of ducted fans in series in long large-opening mines is required to assure the economy and efficiency of the ventilation system. The two most critical design parameters for optimization are the wall separation distance and gap length between adjoining ducts. This study aims at deriving the optimal values for those two parameters concerning the economic and environmental aspects through the extensive CFD analysis, which minimizes pressure loss, leakage and entrainment of the contaminated air in the gap space. The ranges of the wall separation distance and gap length for study are selected by taking into consideration the existing recommendations and guidelines. The ultimate goal is to optimize the auxiliary ventilation system using ducted fans in series to provide a reliable and efficient solution to maintain clean and safe workplace environment in local long underground mines.

Analysis on Activation Characteristic of Heat Detectors in a Compartment Fire (실내화재에서의 열감지기 동작특성 분석)

  • Ryu, Hocheol
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.598-608
    • /
    • 2014
  • The first operation of alarm system starts at a detector. And the largest effect is produced on the operation of detector by the fire source position and installation position. Nevertheless, the Korean standard for the installation of detector only specifies matters of fire detector installation according to area and height, without consideration of installation position and fire source position. Therefore, this study carried out a fire test in consideration of detector installation position and fire source position (5 places) in order to minimize casualties owing to the fast operation of fire detector when a fire occurred. Considering that it took the longest time for a detector close to a wall to work in the results of this test, it was possible to find that a minimum clearance to the wall was required.

Numerical Simulation on Characteristics of Laminar Diffusion Flame Placed Near Wall in Microgravity Environment (미소중력 환경내의 벽면 근방 확산 화염 특성에 관한 수치 해석)

  • Choi Jae-Hyuk;Fujita Osamu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.140-149
    • /
    • 2006
  • Characteristics of a laminar diffusion flame placed near wall in microgravity have been numerically analyzed in a two-dimension. The fuel for the flame is $C_2H_4$. The flame is initiated by imposing a high temperature ignition source. The flow field, temperature field, and flame shape in microgravity diffusion flame are detailed. Especially, effects of surrounding air velocity and fuel injection velocity on the microgravity diffusion flame have been discussed accounting for standoff distance. And, the effect of curvature rate has been also studied. The results showed that velocities in a diffusion flame were overshoot because of volumetric expansion and distribution of temperature showed regularity by free-buoyancy This means that the diffusion flame in microgravity is very stable, while the flame in normal gravity is not regular and unstable due to buoyancy. Standoff distance decreases with increase in surrounding air velocity and with decrease in fuel injection velocity. With increasing curvature rate, the position of reaction rate moves away the wall.

A Study on Improvement of 5G In-Building Quality using Antenna Orientation Principle (안테나 지향성 원리를 이용한 5G 건물 내 품질향상에 관한 연구)

  • Lee, Byung-Chan;Lee, Sung-Hwa;Kim, Jin-Tae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.4
    • /
    • pp.41-48
    • /
    • 2022
  • This study is a study that designed in-building antennas with improved orientation to improve 5G quality in buildings as 5G is stabilized and more and more traffic is expected to occur in buildings. Instead of applying the forward arrangement of antenna elements, which is the Yagi antenna propagation orientation principle, the antenna design method of vertical arrangement applied to the base station antenna was proposed, and it was confirmed through experiments that antenna orientation increased. According to the experimental results, the directivity did not increase significantly within 10m of the separation distance from the antenna, but the directivity increased by about 3dB at the distance separated by more than 10m. Considering that the wireless environment in the building has various variables such as structure of internal structure, materials such as concrete and glass, closed space, and walls, it is expected that antenna with improved orientation can expand the scope of 5G quality improvement and maintain stable communication service in the building.

3-Dimensional Numerical Simulation of Floating Device for Vortex Mitigation in Sump (흡수정 와류 저감을 위한 부유식 장치의 성능 3차원 수치모의)

  • Kim, Hyung-Jun;Rhee, Dong Sop;Yoon, Kwang Seok;Park, Sung Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.325-325
    • /
    • 2017
  • 빗물펌프장은 도시지역 저지대의 우수를 강제로 배출하여 제내지의 치수안전도를 향상시키기 위한 방재시설이다. 변화하는 기상조건에 맞추어 침수취약지역의 치수안전도를 유지 또는 향상시키기 위해서는 빗물펌프장 설계시 목표한 치수성능을 지속적으로 구현할 필요가 있다. 그러나, 펌프시설의 고속운전, 변화하는 펌프운영조건 등의 영향으로 펌프의 성능은 지속적으로 저하된다. 이와 같은 펌프성능의 주요원인은 펌프운영시 발생하는 공기연행이 주요 원인중 하나이다. 흡수정 설계단계에서는 와류에 의한 공기연행을 제어하기 위하여 흡입관경, 흡수정 벽면으로부터의 이격거리 등의 설계요소를 반영하고 있지만, 도심지역의 제한적인 공간특성으로 인하여 설계기준치를 만족하지 못하는 경우가 발생하게 된다. 설계시 흡수정 내에 형성되는 와류를 억제하기 위하여 흡수정의 벽면 모서리를 완만하게 시공하거나, 흡수정 내에 날개벽 또는 별도의 시설을 설치하는 방법을 채택하고 있다. 그러나, 이와 같은 와류방지시설은 고정된 설계조건에 대하여 성능구현이 가능하지만, 홍수시 흡수정 내의 흐름은 하천의 수위 및 유입되는 유량에 의하여 시시각각 변화하게 된다. 이와 같은 운영조건의 변화에 대응할 수 있는 방법을 제시하기 위하여 본 연구에서는 수면에 부유식 와류방지장치를 설치하고 이에 대한 성능을 3차원 수치모의를 통하여 재현한 후 정량적으로 분석하였다. 부유식 와류방지장치에 대한 성능검토결과, 다양한 운영조건에서도 부유식 와류방지장치가 유효한 와류저감효과를 구현하고 있는 것을 확인하였다.

  • PDF

A Model Test on the Settlements of Adjacent Structures by Excavation (모형실험을 통한 굴착시 인접 구조물의 침하량 평가)

  • 석정우;최광철;김운영;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.2
    • /
    • pp.17-27
    • /
    • 1999
  • It comes to be an important point to judge precisely the effects of excavation on adjacent ground and structures. It is incorrect to evaluate the ground settlement by excavation without considering the adjacent structure. In this study, laboratory scale tests were carried out by varying the position of structure under the condition of different system stiffness and wall friction to evaluate the behavior of adjacent structures and ground by excavation. When the distance between the structures and the wall was less than 0.3 times of the excavation depth, the ground settlement increased by 181%. No additional effect was observed when the distance was more than 1.0H. As the embedded depth was deeper, the influence zone was smaller, and few additional settlements and angular displacement were observed when the embedded depth was more than 0.75H.

  • PDF

Model Tests on Ground Deformation during Trench Excavation for Diaphragm Walls (지중연속벽 시공을 위한 트렌치 굴착시 지반변형에 관한 모형실험)

  • Hong, Won-Pyo;Lee, Moon-Ku;Lee, Jae-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.12
    • /
    • pp.77-88
    • /
    • 2006
  • A series of model tests were performed to investigate the ground deformation during trench excavation for diaphragm walls. An apparatus was manufactured to observe the failure pattern of a slurry-supported trench in sandy ground. Ground deformations including settlement and lateral displacement of the surrounding ground adjacent to the trench were carefully monitored during excavation. Experimental observations indicated that the settlement of the adjacent ground increased with closing to the trench. Especially, the considerable settlement occurred at the distance which was equal to 40% of the excavation depth. And, the higher settlement was obtained when the relative density of ground was looser and the ground water table was higher. Also, the lateral wall face of excavated trench was bulged with lowering the slurry level In stages and then the upper part of trench failed finally. The envelope of ground surface settlement could be represented as a hyperbolic line and the measured settlement was smaller than those predicted by Clough and O'Rourke (1990).

Effect of Compaction Method on Induced Earth Pressure Using Dynamic Compaction Roller (진동롤러에 의한 다짐방법이 인접구조물의 다짐토압에 미치는 영향)

  • Roh, Han-Sung
    • International Journal of Highway Engineering
    • /
    • v.3 no.4 s.10
    • /
    • pp.127-136
    • /
    • 2001
  • To increase the structural integrity of concrete box culvert good compaction by the dynamic compaction roller with bi9 capacity is as effective as good backfill materials. It is needed for effective compaction that a compaction roller closes to concrete structure with high frequency. However structural distress of the culvert could be occur due to the excessive earth pressure by great dynamic compaction load. To investigate the characteristics of Induced stress by compaction, a box culvert was constructed with changing cushion materials and compaction methods. Two types of cushion material such as tire rubber chip and EPS(Expanded Polystyrene) were used as cushion panels and they are set on the culverts before backfill construction. Laboratory test result of cushion material says that the value of dynamic elastic modulus of rubber is lesser than that of EPS. On the other hand, material damping of rubber material is greater than that of EPS. In most case, dynamic compaction rollers with 10.5 ton weights were used and vibration frequency was applied 30Hz for the great compaction energy. This paper presents the main results on the characteristics of dynamic earth pressures during compaction. The amounts of induced dynamic pressures$(\Delta\sigma\;h)$ by compaction are affected with construction condition such as compaction frequency, depth of pressure cell, distance between roller and the wall of culvert and roller direction. Based on the measured values dynamic lateral pressure on the culverts, it could be said that orthogonal direction of roller to the length of culvert is more effective to compaction efficiency than parallel direction.

  • PDF

A study on the location of microphones in measurement considering the frequency characteristics of elevator noise in households (세대 내 승강기 소음 주파수특성을 고려한 측정 시 마이크로폰 위치에 관한 연구)

  • Min-Woo Kang;Yang-Ki Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.124-132
    • /
    • 2023
  • When the building becomes high, the number of households increases and they are adjacent to the elevator. So, frequency of use of elevators will increase. Elevator noise is bound to increase in the future. However, there are currently no legal standards for elevator noise or measurement and evaluation methods that can clearly measure elevator noise in Korea. Although some methods for measuring elevator noise are presented in KS F ISO 16032, this standard is not a standard established for elevator noise. It is a standard that integrates the overall measurement method of building equipment and equipment, and the position of the microphone is selected by the experimenter during measurement. Elevator noise is characterized by a low sound pressure level as the noise in the mid-low frequency band is important. However, even today, complaints from residents about elevator noise are increasing. In this study, the position of the microphone that can most sensitively pick up the elevator noise when measuring the elevator noise was studied. According to the distance from the wall and the height from the floor, a total of 9 microphone positions were measured and analyzed. As a result of the experiment, it was confirmed that the elevator noise has a very high influence in the 63 Hz band. The measured value at the center point was identified as a factor that lowered the overall elevator noise level value.