• Title/Summary/Keyword: 벨트

Search Result 698, Processing Time 0.029 seconds

The Effects of Manual Traction Using Belt on Lumbar Intervertebral Space of Lumbar HIVD (벨트를 이용한 도수견인이 허리뼈 척추사이원반 탈출증 환자의 허리뼈 척추사이 공간에 미치는 효과)

  • Seong-gwan, Jeong;Ho-jun, Lee;Seung-byung, Lee
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.28 no.3
    • /
    • pp.1-7
    • /
    • 2022
  • Background: Manual traction with a belt is a physiotherapy treatment method that reduces disk pressure and widens the disk space. In clinical settings, it is applied to numerous patients with herniated intervertebral disk (HIVD). This study aimed to identify the effects of manual traction with a belt on the intervertebral space in patients with lumbar HIVDs. Methods: The intervention was performed on 17 patients with lumbar HIVDs who were divided into two groups: one with eight patients having HIVD at L4~L5 and another group with nine patients having HIVD at L5~S1. The participants received manual traction with a belt twice a week for 12 weeks, and radiographic imaging was used to visualize the intervertebral space and compare it before and after treatment. Results: Manual traction with a belt increased the lumbar intervertebral space at L4~L5 and L5~S1 in patients with L4~L5 HIVD. A significant difference was observed in the L4-L5 distance (p<.01); however, no significant difference was observed in the L5~S1 distance (p>.05). The intervertebral space significantly increased at both L4~L5 and L5~S1 in patients with L5~S1 HIVD (p<.05). Conclusion: Thus, manual traction with a belt increased the intervertebral space in patients with L4~L5 and L5~S1 HIVDs. These results are expected to guide studies on manual traction with belts in clinical settings in the future. Further studies using the present research as an objective study method are anticipated.

The Effect of Modified Constraint-induced Movement Therapy and Resistive Exercise Using Elastic Band with Pressure Belt on Affected Upper Limb Function in Stroke Patients (수정된 강제유도운동과 탄력밴드를 이용한 가압벨트 저항성 운동이 뇌졸중 환자의 상지 기능에 미치는 효과)

  • Kim, Tae-gon;Kim, Kyung-yoon;Bae, Sea-hyun
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.25-36
    • /
    • 2021
  • Background: This study aimed to investigate the effect of modified constraint-induced movement therapy (mCIMT) and resistive exercise using elastic band with pressure belt on improving upper extremity function in stroke patients. Methods: Sixteen patients with stroke were randomly assigned to a control group that received mCIMT and resistive exercise using elastic band (n=8) and an experimental group that received mCIMT and resistive exercise using elastic band with pressure belt (n=8). Over the course of four weeks, mCIMT were conducted 60 minute three times per week and resistive exercise using elastic band (with pressure belt) were conducted twice daily, three times per week. The function of the upper extremities were evaluated before, after 2 weeks and 4 weeks using the grip strength test (GST), the box and block test (BBT), and motor activity log (MAL). Results: The values for the GST, the BBT, and MAL increased in both groups as the treatment period progressed. The values for the GST (p<.01), the BBT (p<.001), and MAL (p<.001) were significantly higher in the experimental group than in the control group at 4 weeks after initiating the treatment. Conclusion: We found that mCIMT and wearing a pressure belt during resistive exercise was very useful in improving the function of the upper extremities in patients with stroke.

Effect of Shoulder Stabilization Exercise with Pelvic Compression Belt Application on Muscle Activity, Pain and Function of Muscles around Shoulder Joint in Subjects with Round Shoulders (둥근 어깨가 있는 대상자에게 골반 압박 벨트 적용을 동반한 어깨 안정화 운동의 수행이 어깨관절 주위 근육의 근활성도와 통증 및 기능에 미치는 영향)

  • Kim, Chung-Yoo;Lee, Yeon-Seop;Kim, Hyeon-Su
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.199-207
    • /
    • 2022
  • Purpose : The purpose of this study is to investigate the effect of shoulder stabilization exercise accompanied by application of a pelvic compression belt on the muscle activity, pain and function of the muscles around the shoulder in subjects with round shoulders. Methods : For the study method, 28 students who were enrolled in K University with a distance of 1 cm or more between the clavicle of the peak and the outer ear path were selected through GPS 400 global postural analysis system measurement. The subjects were randomly assigned to 14 participants in the group wearing a pelvic compression belt and 14 patients in the group not wearing a pelvic compression belt. In all subjects, the muscle activities of the middle trapezius, lower trapezius, and serratus anterior muscles and the shoulder pain disorder index (SPADI) were measured. The intervention was performed 3 times a week for 4 weeks, and the applied intervention was push-up plus and modified prone cobra exercise. The muscle activities of the middle trapezius, lower trapezius, and serratus anterior muscles and SPADI score were compared using dependent t test before and after intervention. Results : In this study, both groups showed that the muscle activity of the middle trapezius, lower trapezius, and serratus anterior significantly increased after the intervention compared to before the intervention. On the other hand, SPADI showed no significant difference. Conclusion : The results of this study showed that muscle activity in the peri-shoulder joint was increased after push-up plus and modified prone cobra exercise in both groups, regardless of whether pelvic compression was applied or not. Therefore, it was found that shoulder stabilization exercise using the pelvic compression belt also contributed to the enhancement of muscle activity in the joints around the shoulder.

A Smart Car Seat System Detecting and Displaying the Fastening States of the Seat Belt and ISOFIX (안전벨트와 아이소픽스의 체결 상태를 감지하여 알려주는 스마트 카시트 시스템)

  • SeungHeun Park;Sangeon Jeon;Beonghoon Kong;seunghwan Kim;Seung Hee Shin;Won-tak Seo;Jae-wan Lee;Min Ah Kim;Chang Soon Kang
    • Journal of Information Technology Services
    • /
    • v.22 no.6
    • /
    • pp.87-102
    • /
    • 2023
  • Existing child car seats do not have a monitoring means for the driver or guardian to effectively recognize the status of whether the seat belt of car seat is fastened and whether the ISOFIX of the car seat is fastened to the inside device of the vehicle. In this paper, we propose a smart car seat system which can monitor in real time, whether the seat belt of a child seated in the car seat is fastened and whether the ISOFIX of the car seat is fastened. The proposed system has been developed with a prototype, in which a Hall sensor, magnet, Bluetooth, and display device are used to detect whether these are fastened and to display the detection results. The prototype system provides the detection results as texts and alarm signal to the display for driver or guardian' smartphone in the car in motion. With functional tests of the prototype system, it was confirmed that the detection functions are properly operated, and the detection results were transmitted to the display device and smartphone via Bluetooth within 0.5 seconds. It is expected that the development system can effectively prevent safety accidents of child car seats.

The effect of Modified Sacroiliac Joint Taping on Back pain_A case report (변형된 엉치엉덩관절 테이핑의 요통 효과 사례보고)

  • Il-Young Cho
    • Journal of Digital Policy
    • /
    • v.3 no.1
    • /
    • pp.21-25
    • /
    • 2024
  • This is a case study that sought to consider whether taping, which focuses on instability of the sacroiliac joint, is a potential intervention method that may be helpful for low back pain. In the case of a 58-year-old participant, we summarized the notable results from a taping training session that a man with a history of back surgery due to disc herniation and stenosis participated in to reduce ongoing pain. As an intervention method, tape was applied between the 2nd and 4th sacrum on both sides from the spinous tuberosity. It was stretched to a tension of 80% and attached past the sacroiliac joint, and then the ends were raised at about 45° on both sides and attached toward the gluteus medius muscle. Then, along the erector spinae muscle from the iliac crest. Bilateral taping up to the level of the 10th rib was applied. Through this intervention, positive case results were observed from both VAS and ODI test tools, with VAS recorded as 5 to 0 and disability index recorded as 13 to 0, respectively.

Design of electric skateboard with gearbox (기어박스가 장착된 전동 스케이트보드 설계)

  • Sang-Hyun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.5
    • /
    • pp.687-692
    • /
    • 2024
  • Recently, electric skateboards have been used as a means of personal transportation due to their convenience and simplicity of operation, but the conventional skateboards driven by timing belts or hub motors have disadvantages such as low driving torque, high current and vibration. Therefore, in this paper, we propose a new type of electric skateboard that can run at high speeds for long periods of time so that it can be used as a auxiliary means of transportation. The planetary gear and motor unit are combined and installed inside one drive wheel, and power is supplied to the wheel through the integrated driving unit to prevent high currents and enable high-speed driving. First, the allowable current and running speed of the electric skateboard were set for efficient personal transportation and the appropriate reduction ratio, modules, and planetary gear dimensions were determined by comparing the torque required for the wheel axis and the maximum output torque of the motor. Additionally, an appropriate suspension device was added to reduce driving vibration for user convenience, and the feasibility of the proposed in-wheel gearbox was experimentally verified through fabrication.

Synthesis and Structure of the Layered Cathode Material $Li[Li_xMn_{1-x-y}Cr_y]O_2$ for Rechargeable Lithium Batteries (리튬2차전지용 양극 소재 $Li[Li_xMn_{1-x-y}Cr_y]O_2$의 합성 및 층상구조 연구)

  • 최진범;박종완;이승원
    • Journal of the Mineralogical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.223-232
    • /
    • 2003
  • The co-precipitation method is applied to synthesize the cathode material Li[L $i_{x}$M $n_{1-x-y}$C $r_{y}$ ] $O_2$ for lithium rechargeable batteries at $650^{\circ}C$ (CR650) and 8$50^{\circ}C$ (CR850), respectively. Rietveld indices indicate that $R_{wp}$ with respect to $R_{exp}$ ( $R_{wp}$/ $R_{exp}$) are 9.2%/10.1% for CR650 and 15.9%/9.76% for CR850, respectively. $R_{B}$ and S (GofF) shows 10.9%, 8.54% and 1.9, 1.6, respectively. Rietveld structure refinement reveals that layer structure of LiMn $O_2$ (R3m) coexists with lower symmetry of Li[L $i_{1}$3/M $n_{2}$3/] $O_2$ (C2/c) due to superlattice ordering of Li and Mn in metal-transition containing layers. Unit-cell parameters are calculated as a=2.8520(2)$\AA$, c=14.248(2)$\AA$, V=100.40(l)$\AA^3$ for CR650, and a=2.8504(1)$\AA$, c=14.2371(7)$\AA$, V=100.179(8)$\AA^3$ for CR850. Final chemistry is obtained as Li[L $i_{0.35}$M $n_{0.56}$C $r_{0.09}$] $O_2$ (CR650) and Li[L $i_{0.27}$M $n_{0.61}$C $r_{0.13}$] $O_2$ (CR850), respectively.y...y..vely.y...y..

Development of the Monte Carlo Simulation Radiation Dose Assessment Procedure for NORM added Consumer Adhere·Non-Adhere Product based on ICRP 103 (ICRP 103 권고기반의 밀착형·비밀착형 가공제품 사용으로 인한 몬테칼로 전산모사 피폭선량 평가체계 개발)

  • Go, Ho-Jung;Noh, Siwan;Lee, Jae-Ho;Yeom, Yeon-Soo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Radiation exposure to humans can be caused by the gamma rays emitted from natural radioactive elements(such as uranium, thorium and potassium and any of their decay products) of Naturally Occurring Radioactive Materials(NORM) or Technologically Enhanced Naturally Occurring Radioactive Materials(TENORM) added consumer products. In this study, assume that activity of radioactive elements is $^{238}U$, $^{235}U$, $^{232}Th$ $1Bq{\cdot}g^{-1}$, $^{40}K$ $10Bq{\cdot}g^{-1}$ and the gamma rays emitted from these natural radioactive elements radioactive equilibrium state. In this study, reflected End-User circumstances and evaluated annual exposure dose for products based on ICRP reference voxel phantoms and ICRP Recommendation 103 using the Monte Carlo Method. The consumer products classified according to the adhere to the skin(bracelet, necklace, belt-wrist, belt-ankle, belt-knee, moxa stone) or not(gypsum board, anion wallpaper, anion paint), and Geometric Modeling was reflected in Republic of Korea "Residential Living Trend-distributions and Design Guidelines For Common Types of Household.", was designed the Room model($3m{\times}4m{\times}2.8m$, a closed room, conservatively) and the ICRP reference phantom's 3D segmentation and modeling. The end-user's usage time assume that "Development and Application of Korean Exposure Factors." or conservatively 24 hours; in case of unknown. In this study, the results of the effective dose were 0.00003 ~ 0.47636 mSv per year and were confirmed the meaning of necessary for geometric modeling to ICRP reference phantoms through the equivalent dose rate of belt products.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Adakitic Signatures of the Jindong Granitoids (진동화강암체의 아다카이틱한 특성)

  • Wee, Soo-Meen;Kim, Yun-Ji;Choi, Seon-Gyu;Park, Jung-Woo;Ryu, In-Chang
    • Economic and Environmental Geology
    • /
    • v.40 no.2 s.183
    • /
    • pp.223-236
    • /
    • 2007
  • The eastern extension of the Cordilleran-type orogenic belt continues from southeastern China to the Chukot Peninsula through the Korean Peninsula. The Gyeongsang basin, located in the southeastern part of the Korean Peninsula and the Inner Zone of southwest Japan are characterized by extensive distribution of Cretaceous to Tertiary I-type calc-alkaline series of intrusive rocks. These intrusive rocks are possibly the result of intensive magmatism which occurred in response to the subduction of the Izanagi Plate beneath the northeastern part of the Eurasian Plate. The Jindong granitoids within the Gyeongsang basin are reported to be adakites, whose signatures are high $SiO_2,\;Al_2O_3$, Sr, Sr/Y La/Yb and, low Y and Yb contents. The major and trace element contents of the Jindong granitoids fall well within the adakitic field, whereas other Cretaceous granites in the same basin are plotted in the island arc ADR area in discrimination diagrams. Chondrite normalized REE patterns show generally enriced LREEs (La/Yb)C = 3.6-13.8) and slight negative to flat Eu anomalies. The mean Rb-Sr whole rock isotopic age of the Jindong granitoids is $114.6{\pm}9.1$ Ma with an initial Sr isotope ratio of 0.70457. These values suggest that the magma has mantle signature and intruded into the area during Early Cretaceous. The Jindong granitoids have similar paleogeographical locations, paleotectonic environments and intrusion ages to those of the Shiraishino granodiorites of Kyushu Island and the Tamba granitoids of San'yo belt located on southwestern Japanese arc.