• Title/Summary/Keyword: 밸브위치

Search Result 162, Processing Time 0.025 seconds

Valve Openings and Minimum Pump Head for Precise Operation of Multiple Groundwater Injection Wells (군정의 주입량의 정밀 제어를 위한 유량조절밸브의 개도 및 최소 펌프 소요양정)

  • Park, Namsik;Jang, Chi Woong;Cho, Kwangwoo
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.10
    • /
    • pp.869-877
    • /
    • 2015
  • Freshwater may be injected into aquifers to combat sea water intrusion in groundwater or to store water for later retrieval. For these cases to achieve the desired goal groundwater modeling is commonly used to determine locations and rates of injection wells. When these wells are connected to a pipe network, a flow control valve is installed for each well to regulate the injection rate. When a valve opening is modified, pressure changes in the entire pipe network and thereby changes flow rates in other wells. Therefore, desired valve openings must be determined for all injection wells. The pipe flow analysis allows estimation of the minimum pump power in addition to valve openings. Methods are developed to identify valve openings for multiple wells and the minimum pump power. The methodology developed in this work can contribute to precise operation of multiple injection wells.

Finite Element Analysis and Design Verification Test of Circular Plate Spring in Thruster Valve of Satellite Propulsion System (위성 추진시스템 추력기 밸브 내 원형 판스프링 유한요소해석 및 설계 검증시험)

  • Ko, Sujeong;Son, Miso;Kim, Namhui;Kim, Jonghak;Yoon, Hosung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.838-842
    • /
    • 2017
  • The thruster valve, which is one of the key components applied to the mono-propellant system for the satellite, has a circular plate spring structure. It can be designed as a structure that does not have positional deformation and particles by friction and repetitive motion. In this study, finite element analysis and verification were performed by setting the width of the circular plate spring as a design parameter with the material, thickness and radius of the circular plate spring as fixed variables. The linearity of the spring constant is shown by the graph that is spring force with displacement. It is confirmed that the optimization design of the circular plate spring is possible by the spring force tendency according to the total area of circular plate spring.

  • PDF

A Study on the Development of Electric Actuator Control Device for Driving Time Setting Valve Using VHDL (VHDL을 이용한 구동 시간 설정 밸브 전동 엑추에이터 제어 장치 개발에 관한 연구)

  • Kang, Dae-Guk;Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.452-459
    • /
    • 2020
  • The electric actuator receives the user's command input signal (open/closed/stop), checks the status of various sensors (valve position, rotational force, motor status, etc.)in the actuator, and controls the motor forward/reverse to open and close the valve. It is a device that outputs the current state of an actuator (valve) and is used in various fields such as dams, power plants, water and sewage facilities, and oil pipeline facilities. If an electric actuator is installed in a power plant and a problem occurs during operation, it can cause a large economic loss, so system reliability is vert important. In this study, in order to increase the safety of the electric actuator, the development of an electric actuator control device capable of setting the ON/OFF time in hardware was conducted to solve the reliability problem that may occur in software. In addition, the electric actuator control device development environment was developed using Xilinx's Spartan7 FPGA and Altium tool.

Defining Flushing Path and Priority for Flushing Operation (플러싱공법을 위한 세척구역 및 순서 결정방안)

  • Gim, A Rin;Jo, Yeong Bin;Ha, Jeong Tae;Kim, Jin Hyeok;Jun, Hwan Don
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.239-239
    • /
    • 2020
  • 상수관망은 수용가에게 용수를 공급하는 사회기반시설물로, 용수를 공급하는 과정에서 관내에 이물질, 스케일 등의 생성은 불가피하다. 관로 변경, 단수로 인한 비상시 용수 공급 등의 유향 및 유속이 변화가 발생할 경우 스케일이 박리되어 적수사고 등의 수질문제가 발생 할 수 있으며, 이에 사전에 스케일을 제거 할 필요성이 있다. 스케일을 제거하기 위해서는 주기적인 관세척이 필요하며, 대표적인 공법으로는 플러싱공법이 있다. 현재까지 플러싱공법에 대한 연구는 실험을 통한 적용 권장 기준으로 진행되어 왔으나, 실제 상수관망에서 적용권장 기준을 확보하기 위한 방안에 대한 연구는 미흡한 실정이다. 플러싱공법의 대표적은 종류는 재래식 플러싱공법과 단방향 플러싱공법이 있다. 재래식 플러싱공법은 제수밸브를 조작하지 않는 방법으로, 모든 소화전에서 용수를 방출하는 공법이다. 단방향 플러싱공법은 제수밸브를 조작하여, 일정한 방향으로 요수를 방출하는 공법이다. 단방향 플러싱공법은 재래식 플러싱공법보다 유속확보 측면에서 유리하여 관로 세척을 위한 유량 및 유속 확보가 용이하다. 단방향 플러싱공법을 적용하기 위해서는 관로의 유속을 확보하기 위해 세척구역 정의하는 것이 필요하다. 이에 본 연구에서는 세척구역 정의를 통한 플러싱공법 적용 방안을 제안하고자 한다. 세척구역은 크게 3단계로 구분한다. 먼저 블록단위의 세척순서를 결정하고, 블록 내 관망 세척구역을 결정한다. 이때 관로의 관경, 곡선구간, 세척구역의 길이를 고려하여 세척구역을 정의한다. 마지막으로 결정된 세척구역을 제수밸브의 위치, 조작 횟수에 근거하여 세척순서를 결정한다. 본 연구를 통해 실제 상수관망 플러싱공법 적용 절차 수립에 기여할 수 있다.

  • PDF

A Study on the Dynamic Behavior Characteristics of a Small Fishing Crane (소형 어로 크레인의 동적 거동 특성에 관한 연구)

  • 이원섭;이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.163-173
    • /
    • 2001
  • The dynamic behavior characteristics of a small fishing crane for inshore and coastal fishing vessels was experimentally analyzed in order to improve the fishing operation and to reduce considerably manual work of fisherman. The small fishing crane was designed to be controlled electro-hydraulically by means of proportional valves and solenoid valves, and also to be controlled the speed of each operation. The dynamic behavior characteristics was investigated by measuring the changes of parameters such as oil pressure, swing angle of load, load tension, the lifting angle and the swing angle of crane arm when the arms extended in a side way was given a test load. The results obtained are summarized as follows: 1. The designed small fishing crane can be proportionally controlled by means of proportional valves and rapidly by operating the solenoid valves, respectively. The capacity, turning angle, maximum reach of crane were 2 T-M, $180^\circ$, 3.7m, respectively. 2. The vertical change of crane arm on the extension of lifting cylinder was $1.2^\circ$/cm, and the swing speed of crane arm due to the extension of swing cylinder by on/off operations of solenoid valves was $15^\circ$/sec, with the swing period of 1.4 sec and the angle fluctuation of $\pm$11.0$^{\circ}$. 3. When changing simultaneously the horizontal and vertical positions of the lifting load by on/off operations of solenoid valves, the swing and lifting speeds of crane arm were $4.46^\circ$/sec and $6.4^\circ$/sec, respectively. 4. The movements of the designed crane were particularly smooth as they are controlled with the aid of proportional valves than by means of solenoid valves.

  • PDF

An evaluation of the pipe failure impact in a water distribution system considering subsystem isolation (상수관 파괴시 관망의 부분적 격리를 고려한 피해범위 산정)

  • Jun, Hw-Andon
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.2 s.163
    • /
    • pp.89-98
    • /
    • 2006
  • To evaluate the pipe failure impact, current methodologies consider only a broken pipe as the impacted area. However, these approaches are accurate if the broken pipe is the only area isolated from tile system. Depending on the number and locations of on-off valves, more pipes which are adjacent to a broken pipe may be isolated. Using the concept of Segment suggested by Walski, the methodology evaluating the pipe failure impact incorporated with on-off valve locations has been suggested by Jun. However, a segment cannot account for all possible pipe failure impacted areas since it does not consider additional failures, namely the network topological failure and the hydraulic pressure failure. For this reason, a methodology which can consider the network topology and hydraulic pressure limitation as well as on-off valve locations is suggested. The suggested methodology is applied to a real network to verify its applicability As results, it is found that a single pipe failure can affect huge areas depending on the configuration of on-off valves and the network topology. Thus, the applicability of the suggested methodology for evaluating the pipe failure impacts on a water distribution network is proved.

가스관련 소식-도시가스시설 검사 처리 세부지침 개선

  • Korea Mechanical Construction Contractors Association
    • 월간 기계설비
    • /
    • no.9 s.218
    • /
    • pp.68-69
    • /
    • 2008
  • 도시가스시설 검사 처리 세부지침이 개선되었다. 개정된 주요 내용은 $\Delta$내압 기밀시험 실시방법 개선 $\Delta$전기방식 생략 $\Delta$사용자공급관 입상관 밸브 설치위치 개선 $\Delta$용접 및 비파괴시험 공정 입회범위 개선 $\Delta$방호구조물 설치기준 제정 $\Delta$사용자공급관 계통도 제출 $\Delta$완성검사 필증현장 발급대상 추가 등이다. 기타 자세한 내용은 대한설비건설협회 홈페이지(http://www.kmcca.or.kr) 공개자료실에 게재되어 있다.

  • PDF

Selection of Butterfly Valve Seat on Upper Deck for Ice Class Vessel (외기와 접하는 버터플라이 밸브 재질 선정)

  • Park, S.H.;Ok, Y.K.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.17-18
    • /
    • 2006
  • 최근 중동지방의 정세 불안과 원유 자원의 고갈로 인한 대체 지역으로 러시아 시베리아 유전이 각광을 받고 있임. 시베리아 유전 원유 수송이 파이프라인을 통해 발틱 연안에 위치한 프리모스크항 도달하여 해상을 통한 원유 수출이 증가함에 따라 ICE Class 대형 Tanker의 수요가 급격히 증가하고 있는 실정.

  • PDF

무선 인터넷을 이용한 웹기반 진동해석 및 제어시스템 구축에 관한 연구

  • 문경주;김영배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.281-281
    • /
    • 2004
  • 본 논문에서는 레이들(ladle)에 실린 용강의 균일한 혼합을 위해 사용되는 저취 시스템의 버블 강도를 예측하기 위해 진동센서를 이용한 안착대를 설계하고 제작하였다 또한 무선 인터넷을 이용해 안착대로부터 진동 데이터를 수신하여 실시간으로 원격지에 위치한 서버에 저장하는 시스템을 구현하였다. 이와 함께 저취 시스템에 사용되는 유량제어밸브를 컨트롤하기 위해 기존에 사용되는 프로토콜 변환기를 변경한 데이터 처리장치를 설계하고 제작하였다. 데이터처리장치는 4개의 직렬 신호를 동시에 처리 가능하며 비구조화된 데이터를 보관하다록 하기 위해 플래쉬 메모리를 장착하였으며, CPU의 데이터 처리를 위해 SRAM을 장착하도록 구성하였다.(중략)

  • PDF

가스계소화설비의 약제 방출량에 대한 이론적 고찰 및 방출시험 (II)

  • Park, Sin-Yeong;Kim, Wi-Gyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.71-72
    • /
    • 2013
  • 가스계 소화설비는 소방관계법에 따른 인증 프로그램에 의해 설계를 수행한다. 하지만, 현장에 설치되는 가스계 소화설비는 공급배관의 규모 및 형상에 차이가 있어 인증 프로그램의 적절성을 보장 할 수가 없다. 따라서 모의시험을 통해 선택밸브 위치에 따른 차이점을 검증하여 모의시험의 개선방향을 제시하고 직접 방출시험의 소개와 가스계 소화설비의 판정방법 개선 필요성을 제시하고자 한다.

  • PDF