• Title/Summary/Keyword: 밸브설계시스템

Search Result 261, Processing Time 0.028 seconds

Development and Application of Pipeline Network Optimization Simulator (파이프라인 네트워킹 최적화 모델의 개발 및 활용)

  • Sung Won-Mo;Kwon Oh-kwang;Lee Chung-Hwan;Huh Dae-ki,
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.56-63
    • /
    • 1997
  • This paper presents a hybrid network model(HY-PIPENET) implementing a minimum cost spanning tree(MCST) network algorithm to be able to determine optimum path and constrained derivative(CD) method to select optimum Pipe diameter. The HY-PIPENET has been validated with the published data of 6-node/7-pipe network. Networking system and also this system has been optimized with MCST-CD method. As a result, it was found that the gas can be sufficiently supplied at the lower pressure with the smaller diameters of pipe compared to the original system in 6-node/7-pipe network. Hence, the construction cost was reduced about $40\%$ in the optimized system. The hybrid networking model has been also applied to a complicated domestic gas pipeline network in metropolitan area, Korea. In this simulation, parametric study was peformed to understand the role of each individual parameter such as source pressure, flow rate, and pipe diameter on the optimized network. From the results of these simulations, we have proposed the optimized network as tree-type structure with optimum pipe diameter and source pressure in metropolitan area, Korea, however, this proposed system does not consider the environmental problems or safety concerns.

  • PDF

Design and simulation of hydraulic system for launch vehicle holding device (우주발사체 지상고정장치 유압시스템 설계 및 해석)

  • Kim, Dae Rae;Yang, Seong Pil;Lee, Jaejun;Kim, Bum Suk;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1087-1094
    • /
    • 2016
  • The responsibility of the vehicle holding device (VHD) is to hold the launch vehicle while it is stayed on launch pad and release the holding mechanism to allow a lift-off of launch vehicle at a moment of lift-off. During a release of the holding mechanism, in order to prevent the Ka doing a doing a doing mode which is vertical oscillation of entire liquid propellant and very severe for vehicle structure, gradual release of holding force is required. Also, a release operation of all 4 VHD should be synchronized very precisely. In this study, to comply the "gradual release and synchronized operation requirement", concept of VHD hydraulic system using an accumulator, pyro valve and orifice to control speed of hydraulic cylinder is proposed instead of using complicated hydraulic components. Then through multi-body dynamic analysis and computational hydraulic analysis, a size of orifice to meet a target speed of hydraulic cylinder is calculated. Through this study, simple and reliable VHD hydraulic system complying requirements is designed.

Modeling and Simulation of A Small Hydraulic Actuation System for the Tactical Missile (전술유도무기용 소형 유압식 구동장치의 모델링 및 시뮬레이션)

  • Lee, Doyun;Lee, Hosung;An, Sungyong;Park, Yeonjung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.4
    • /
    • pp.349-357
    • /
    • 2017
  • If an actuation system of the tactical missile is required very fast response time on conditions of short operating time and big loads on the actuator, we would prefer to adopt a small hydraulic system. In this paper, a mathematical model is proposed to analyze and simulate the small hydraulic actuation system. The mathematical model consists of a high pressure vessel model, a pressure regulator model, a hydraulic reservoir model and a actuator model. The suggested model is validated by comparison of simulation results with experimental data. The simulation results show that the mathematical model could be useful for designing a hydraulic actuation system.

Development of Pilot Injection Plant for CO2 Underground Storage (이산화탄소 지중저장용 파일럿 주입플랜트 개발)

  • Yoon, Seok-Ho;Kim, Young;Lee, Jun-Ho;Lee, Kong-Hoon
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.42-45
    • /
    • 2013
  • The worldwide issue of greenhouse gas reduction has recently drawn great attention to carbon capture and storage(CCS). In this study, we developed a 10,000 ton/year pilot injection plant for geological storage of carbon dioxide. Major components of the pilot plant include a pressure pump, a booster pump, and an inline heater to bring liquid carbon dioxide into its supercritical state. The test results show that the pilot plant readily achieves the injection pressure and temperature, showing satisfactory control performance. The overall power consumption is 2,000 ~ 2,500 W, more than 75% of which consumed by the pressure pump. This study will facilitate varied research on greenhouse gas reduction as the only domestically developed system for geological injection.

  • PDF

Development of pulse diagnosis possible simulator using the stepper motor pumps (스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발)

  • Ryu, Geun-Taek;Woo, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.915-918
    • /
    • 2016
  • Virtual testing devices are required due to rapid changes in the health care industry and the increase of the medical or nursing workforce. The importance of devices such as the simulator, blood vessels, and lab equipment for modeling blood flow to the heart is increasing too. In this study, we made heart pump by using a step motor and developed device which simulates arterial, venous blood pressure, and blood flow. We finally evaluated the function of proposed device. The proposed system is composed of the pump for simulating, the valve device to describe the resistance of the artery and vein, and a reducing device showing the characteristics of the venous system. We used BOXER pump for heart simulator and silicon tube for arterial and venous vessels, and designed a reducing device. We also used the pressure sensor to measure arterial blood pressure. For the evaluation of the proposed system, we selected a range of 50~100mmHg of the blood circuit 60 per minute and then compared the blood pressure of a person and the measured blood pressure.

  • PDF

Effect of Absorbent Thickness on the Noise Level Reduction of Fire-Extinguishing Nozzle (흡음재 두께가 소화노즐 소음도 저감에 미치는 영향)

  • Kim, Hak-Sun;Hwang, In-Ju;Kim, Youn-Jea
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.99-104
    • /
    • 2019
  • In a gas system fire extinguishing system, extinguishing agents are usually stored with approximately 280 bar at $21^{\circ}C$ and are released at approximately 8 MPa through the decompression valve and orifice to quickly suppress the fire. When extinguishing agents are discharged, they cause a loud noise (approximately 140 dB), which can damage electronics, such as hard disk drives (HDDs). Therefore, the noise is becoming a serious issue in the gas extinguishing system. The method of the noise reduction by adding an absorbent is most general and in this study, the thickness of the absorbent was as a selected design variable. The noise level at the observation point and the flow characteristics inside the nozzle were numerically calculated and analyzed using the commercial code ANSYS CFX ver. 18.1.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

FEA(Finite Element Analysis) Study for Electronic Hydrogen Regulator of Confidentiality Improvement (전자식 수소레귤레이터 기밀성 향상을 위한 FEA 연구)

  • Son, Won-Sik;Song, Jae-Wook;Jeon, Wan-Jae;Kim, Seung-Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.175-181
    • /
    • 2019
  • In the case of a conventional single stage decompression regulator used for large depressurization in the hydrogen fuel cell system of a fuel cell electric vehicle (FCEV), problems can arise, such as pulsation, slow response, hydrogen brittleness, leakage, high weight, and high cost due to high decompression. Most of these problems can be overcome easily using two decompression mechanisms (two-stage structures). In addition, a wide outlet-pressure control range can be secured if an electronic solenoid is applied to the second decompression. Accordingly, it is necessary to improve the precision of the outlet pressure of a two-stage pressure-reducing regulator and develop techniques, such as leakage prevention, durability, light weight, and price reduction. Therefore, to improve the outlet pressure accuracy and prevent leakage, the structural part before and after decompression to improve the air tightness were divided and the analysis was carried out assuming that the valve part was closed (open ratio: 0%) after each initial internal pressure application.

GIS based Effective Methodology for GAS Accident Management (GIS를 이용한 효율적인 가스사고관리 방법에 관한 연구)

  • 김태일;김계현;전방진;곽태식
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.399-406
    • /
    • 2004
  • 최근 급속한 도시의 팽창과 산업의 발전으로 인하여 가스시설은 급속히 확대되고 있는 실정이다. 이러한 가스시설물의 중요성을 인식하고 많은 도시가스업체에서는 가스관망 시설정보를 전산화하여 항상 최신의 현황을 유지할 수 있는 가스시설물관리시스템을 개발하여 사용하고 있다. 그러나 이러한 시스템은 가스시설물의 현황파악 및 유지관리를 위한 기본적인 기능만을 제공하는 관계로, 가스 누출사고 발생시 정확한 사태의 파악과 함께 신속한 대책 마련을 위한 의사결정 지원이 어려운 실정이다. 따라서 체계적인 가스사고관리를 수행할 수 있는 응용시스템의 필요성이 증대되고 있다. 이러한 시점에서 본 연구에서는 가스사고분석을 신속하고 체계적으로 수행할 수 있는 가스사고관리 적용알고리즘 분석 및 최적의 알고리즘을 정립하여 가스사고관리시스템을 구현하였다. 본 연구를 통한 결과는 1ㆍ2차 차단밸브의 산정이 가능해짐으로써 빈번한 가스 누출사고 발생시 실시간으로 적정대처방안의 제시가 가능하게 되었다. 또한, 누출 최대가스량을 제시함으로써 누출에 대한 피해예상 분석을 위한 정보 제공 및 가스의 신속한 재공급을 위해 필요한 의사결정 지원 정보의 제공이 가능하게 되었다. 아울러, 가스누출사고에 의한 가스공급중단 관로 및 수용가에 대한 속성현황의 파악은 물론 시각적인 도식을 통한 전체적 현황파악이 가능하였다. 이러한 가스사고관리시스템의 개발을 통하여 사고 발생시 신속한 사고방안 제시 및 사고피해의 최소화를 위해 필요한 의사결정 지원 정보의 제공이 가능하게 됨으로써 국민의 안전 및 복지와 도시가스업체의 업무 효율화로 인한 예산절감 효과를 기대할 수 있다. 가시권 분석기능을 이용하여 실제 지형공간상에서 전파경로 손실치를 도시화함으로써 전파관리자가 무선서비스지역 설계, 전파음영지역 판단, 최적 중계기와 기지국 위치 선정에 기여할 것으로 판단된다.하지 않은 지역과 서로 다른 분광특성을 나타내므로 별도의 Segment를 형성하게 된다. 따라서 임상도의 경계선으로부터 획득된 Super-Object의 분광반사 값과 그 안에서 형성된 Sub-Object의 분광반사값의 차이를 이용하여 임상도의 갱신을 위한 변화지역을 탐지하였다.라서 획득한 시추코아에 대해서도 각 연구기관이 전 구간에 대해 동일하게 25%의 소유권을 가지고 있다. ?스굴 시추사업은 2008년까지 수행될 계획이며, 시추작업은 2005년까지 완료될 계획이다. 연구 진행과 관련하여, 공동연구의 명분을 높이고 분석의 효율성을 높이기 위해서 시료채취 및 기초자료 획득은 4개국의 연구원이 모여 공동으로 수행한 후의 결과물을 서로 공유하고, 자세한 전문분야 연구는 각 국의 대표기관이 독립적으로 수행하는 방식을 택하였다 ?스굴에 대한 제1차 시추작업은 2004년 3월 말에 실시하였다. 시추작업 결과, 약 80m의 시추 코아가 성공적으로 회수되어 현재 러시아 이르쿠츠크 지구화학연구소에 보관중이다. 이 시추코아는 2004년 8월 중순경에 4개국 연구팀원들에 의해 공동으로 기재된 후에 분할될 계획이다. 분할된 시료는 국내로 운반되어 다양한 전문분야별 연구에 이용될 것이다. 한편, 제2차 시추작업은 2004년 12월에서 2005년 2월 사이에 실시될 계획이다. 수백만년에 이르는 장기간에 걸쳐 지구환경변화 기록이 보존되어 있는 ?스굴호에 대한

  • PDF

Design of a Neural Network PI Controller for F/M of Heavy Water Reactor Actuator Pressure (신경회로망과 PI제어기를 이용한 중수로 핵연료 교체 로봇의 구동압력 제어)

  • Lim, Dae-Yeong;Lee, Chang-Goo;Kim, Young-Baik;Kim, Young-Chul;Chong, Kil-To
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1255-1262
    • /
    • 2012
  • Look into the nuclear power plant of Wolsong currently, it is controlled in order to required operating pressure with PI controller. PI controller has a simple structure and satisfy design requirements to gain setting. However, It is difficult to control without changing the gain from produce changes in parameters such as loss of the valves and the pipes. To solve these problems, the dynamic change of the PI controller gain, or to compensate for the PI controller output is desirable to configure the controller. The aim of this research and development in the parameter variations can be controlled to a stable controller design which is reduced an error and a vibration. Proposed PI/NN control techniques is the PI controller and the neural network controller that combines a parallel and the neural network controller part is compensated output of the controller for changes in the parameters were designed to be robust. To directly evaluate the controller performance can be difficult to test in real processes to reflect the characteristics of the process. Therefore, we develope the simulator model using the real process data and simulation results when compared with the simulated process characteristics that showed changes in the parameters. As a result the PI/NN controller error and was confirmed to reduce vibrations.