A Study on the Fluid Interception Valve According to Non Rubbing Top and Bottom operation Shaft (무마찰 상하작동 축에 의한 유체차단 밸브에 관한 연구)

  • Cho, Myung-Hyun
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.4
    • /
    • pp.27-32
    • /
    • 2005
  • Liquid valve is divided into cylinder and liquid part or composed of a single body structure. It becomes a connected structure to cylinder head after inserting stainless(STS) shaft to Teflon packing. In injecting and intercepting fluid, working efficiency becomes low because of the top and bottom round trip operation the friction between Teflon packing and STS shaft fluid leakage, decline of working environment, and each part replacement. And so target value is unattainable in productivity liquid valve design, quality, and structure change are studied. In this paper, designed to solve the existing problems basically, to prevent friction of Piston by developing diaphragm linked with piston, to satisfy long life, and to provide the prevention of leakage. The objective of the study is also to prevent remains fluid at nozzle tip after dispensing fluid, and bell close with the suction function in piston retreating.

Development of a diaphragm type actuator (다이어프램형 방식의 파일럿 액추에이터 개발)

  • Lee, Joongyoup;Jeong, Daeseong;Han, Sangyeop
    • Aerospace Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.160-166
    • /
    • 2014
  • The shutoff valve of a Liquid Rocket Engines (LRE) controls the flow of propellant between turbo-pump and combustion devices of LRE using pilot pressure and spring force. The shutoff valve is closed when the pilot pressure is removed from the diaphragm type actuator. During designing process of life cycle is when should be analyzed according to the characteristics of forces with respect to the opening and closing of diaphragm actuator. A valve has been designed to adjust the control pressure which is required to open a poppet and to determine the working fluid pressure at which a valve starts to close. During flow capacity test under room temperature as a part of life cycle tests, the leakage in diaphragm was occurred due to the leakage of sheet welding sections. The operating cycle of the diaphragm type actuator is about 61 times with 22 MPa of pilot pressure.

The Performance of a New Pressure Reducing Valve Automatically Preventing Pressure Equalization (자동 균압 방지 감압밸브의 감압성능에 관한 연구)

  • Park, Yong-Hwan;Kim, Sang-Wook;Kim, Beom-Kyu
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.26-30
    • /
    • 2013
  • It is necessary to use pressure reducing valves to provide required water pressure in water-based fire suppression systems of the tall buildings. In many cases, however, pressure reducing valves lose their function due to the phenomenon of pressure equalization caused by valve leak. This study carried out performance evaluation of the recently developed pressure reducing valve to prevent pressure equalization and found it can maintain designed pressure reducing ratio within 11% variation and prevent pressure equalization by automatic self-lock function of the piston.

Evaluation the Impact of Installing a Isolation Valve on Condensate System of Nuclear Power Plan (원자력발전소 복수기 수실 차단밸브 설치 영향 평가)

  • Lee, Sun-Ki
    • Journal of Industrial Convergence
    • /
    • v.18 no.4
    • /
    • pp.15-21
    • /
    • 2020
  • Because there are no isolation valves in condensate system of nuclear power plants, circulating water pump was shutdown for the condenser repair. When circulating water pump was shutdown, power plant output decreased about 45%. These output decreasing can minimize by establishing isolation valves. In this paper, evaluated effect to flow conditions change of condensate system, structural integrity of system, condenser pressure of in case of establish isolation valves to condensate system. Results of the evaluation, the flow rate due to the installation of the isolation valve decreased 0.3% when the valve was fully opened and 4.5% when fully closed. In addition, it was found that the vacuum degree of the condenser decreased with decreasing flow rate, but the integrity of the system was maintained.

Study for Failure Examples Including with Gas filter Clogging of Emergency Cutting Valve, Assemblying Part Damage of Solenoid Valve, Contact Damage of LPG Switch Connector Fin in a LPG Car (LPG 자동차의 긴급차단밸브 기상필터막힘, 솔레노이드밸브 조립부손상, LPG 스위치 커넥터 핀 접촉불량에 관련된 고장사례 연구)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Kim, Jee Hyun;Kim, Sung Mo;Jung, Dong Hwa;You, Chang Bae;Moon, Hak Hoon;Lee, Jeong Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • This paper is a purpose to study and analyze the engine starting failure examples for LPG car. The first example, the researcher verified the phenomenon that didn't supply the fuel because of filter clogging by fine alien substance in the gas valve line when he inspected the emergency cutting valve. The second example, there was no the influence of gas leakage when the solenoid operated at first. But the damage part of solenoid assemblying face wad downed a durability according to running a valve. Eventually, the researcher checked on the phenomenon of engine stopping by no gas feeding in solenoid because of leaking of gas. The third example, the researcher sought that the wiring sheaths of connector fin between EGR 10A fuse and LPG switch verified the burn-out phenomenon due to the bad contacting as tension damage produced the overheating. Therefore, the manager of a car has to do pre-inspection no producing electric failure and he must maintain his car with optimum condition.

A Study on Durability Test of Check Valve for CNG Vehicles (천연가스 차량용 체크밸브의 내구성능에 관한 연구)

  • Kim, Chang-Gi;Lee, Sun-Youp;Cho, Gyu-Baek
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.15-20
    • /
    • 2009
  • The number of compressed natural gas (CNG) vehicles have increased gradually by virtue of korea government's urban air quality improvement policy since 1998. Although the use of CNG as transportation fuel gives environmental benefits, there is a possibility of huge accidents from unexpected fire. Therefore, needs for the guarantee of safety are indispensible for the reliable operation of CNG vehicles. A check valve is a safety device which prevents leakage of the pressurized fuel charged in a fuel tank. Durability of this component should be guaranteed in spite of repeated operation. This research has performed durability tests of a CNG check valve regarding the repeated usage, extreme chattering, and the effect of compressor oil.Although a check valve used for CNG vehicle satisfies validation requirements in the test results, it has been found that problem in the function of leakage prevention in a check valve could take place in the case of prolonged exposure to compressor oil.

  • PDF

Status of Thermal Stratification Research on Piping System in Korea Nuclear Power Plant (국내원전 배관계통 열성층 연구개발 현황)

  • Lee, Sun Ki
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.2
    • /
    • pp.25-33
    • /
    • 2016
  • The thermal stratification phenomenon in the nuclear power plant can cause abnormal deformation of the piping, contact with the support, damage to the support system. Repetition of the thermal stratification phenomenon or variation of the thermal boundary layer can cause thermal fatigue. Thermal stratification phenomenon in nuclear power plants is still an ongoing issue and active research has been carried out. In this paper, the current situation in Korean nuclear power plants is described, followed by the status of research and the future problems on the thermal stratification phenomenon in Korea.

A Study on the Lubrication Characteristics of Spool Valve with Spiral Groove (스파이럴 그루브가 가공된 스풀밸브의 윤활 특성 연구)

  • Hong, Sung-Ho;Son, Sang-Ik;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.28 no.6
    • /
    • pp.303-314
    • /
    • 2012
  • In this research, spool valves with spiral grooves are suggested and their lubrication characteristics are investigated by numerical analysis. The three-dimensional flow field is obtained by solving the Navier-Stokes equations in dimensionless form, so that the performance variables such as lateral force, friction force and volume flow rate are determined. Also, the lubrication characteristics of spool valves with spiral grooves are compared with those with typical grooves under variable working conditions. It is shown that spool valves with spiral grooves can get better performance in aspect of mitigation of uneven pressure distribution surrounding spool. Moreover, it is found that the minimum distance between spool edges and grooves, the type of spiral groove, and the groove angle have noticeable effect on the lubrication characteristics.

Study on the Current Safety Management Status and Safety Improvement of Gas Valve (가스밸브의 안전관리 현황 및 안전성 향상 연구 (모니터링을 중심으로))

  • Choe, Byeong-Gyu;Cha, Min-Chang;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.57-63
    • /
    • 2016
  • Though a valve is a very important part in a system to control properly, it has potential failure caused by gap from valve stem to ball connection, and abrasion, crack, fixation causing operational trouble and accidents. 64% of the valve failure in the real case was the failure of airtightness and most accidents of leakage and explosion were occurred while fixing the failure. While there are no proper safety manual, maintenance procedure and regulation for industrial valves excluding safety valve, safety management for the valves is left to the discretion of the maintenance company. Strict maintenance that removes hazards and emergency response procedure are required to prevent and reduce the loss of accident. This study suggests safety enhancement measures through valve monitoring by investigating the status of use of valve and current maintenance. Enhancement of gas safety management can be acquired by a monitoring system that provides diagnosis for valve status, monitoring real-time gas leakage, management of entire cycle lifetime that can reduce maintenance cost.