• 제목/요약/키워드: 밸런싱

Search Result 402, Processing Time 0.024 seconds

Enhanced Switching Pattern to Improve Energy Transfer Efficiency of Active Cell Balancing Circuits Using Multi-winding Transformer (다중권선 변압기를 이용한 능동형 셀 밸런싱 회로의 에너지 전달 효율을 높이기 위한 향상된 스위칭 패턴)

  • Lee, Sang-Jung;Kim, Myoungho;Baek, Ju-Won;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.4
    • /
    • pp.279-285
    • /
    • 2019
  • This study proposes an enhanced switching pattern that can improve energy transfer efficiency in an active cell-balancing circuit using a multiwinding transformer. This balancing circuit performs cell balancing by transferring energy stored in a specific cell with high energy to another cell containing low energy through a multiwinding transformer. The circuit operates in flyback and buck-boost modes in accordance with the energy transfer path. In the conventional flyback mode, the leakage inductance of the transformer and the stray inductance component of winding can transfer energy to an undesired path during the balancing operation. This case results in cell imbalance during the cell-balancing process, which reduces the energy transfer efficiency. An enhanced switching pattern that can effectively perform cell balancing by minimizing the amount of energy transferred to the nontarget cells due to the leakage inductance components in the flyback mode is proposed. Energy transfer efficiency and balancing speed can be significantly improved using the proposed switching pattern compared with that using the conventional switching pattern. The performance improvements are verified by experiments using a 1 W prototype cell-balancing circuit.

Design of 2.5kW DC power supply for 2.45GHz industrial magnetron (2.45GHz 산업용 마그네트론 구동을 위한 2.5kW DC 전원장치 설계)

  • Kim, Tae-Hyun;Bae, Jung-Soo;Kim, Shin;Kim, Do-Kyun;Kim, Hyeong-Suk;Yu, Chan-Hun;Han, Seong-Tae;Jang, Sung-Roc
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.251-253
    • /
    • 2019
  • 본 논문은 1.8kW (4.5kV, 450mA)출력의 마그네트론을 구동하기 위한 2.5kW (5kV, 0.5A) 고전압 DC 전원장치 설계에 대해 기술한다. 무선 전력 전송을 위한 위상배열 시스템에 이용되는 마그네트론의 경우 인가되는 전압의 리플 최소화는 필수적이다. 본 논문에서는 소프트 스위칭을 기반으로한 400kHz 이상의 스위칭 주파수로 컨버터를 설계함으로써 출력리플을 저감하고 필터성분을 최소화 하여 전력밀도를 높일 수 있도록 한다. 변압기의 누설인덕턴스 만을 이용하여 공진 인덕터를 구현하고 변압기의 기생 커패시터 성분과 직렬로 스택킹 된 출력 정류 다이오드의 전압 밸런싱을 위한 커패시터를 병렬 공진 커패시터로 활용한 LCC 공진형 컨버터 고밀도 설계에 대하여 기술한다. 또한, 공진전류의 Trapezoidal 해석 및 설계를 통해 도전 손실을 줄일 수 있는 LCC공진형 컨버터 기반의 마그네트론 구동전원 설계에 대하여 상세 기술하고 PSpice를 이용한 Simulation 및 실험 결과를 통하여 개발된 전원의 우수성을 검증한다.

  • PDF

Implementation and Fault-tolerance Tests of High Availability System in Cloud Environment (클라우드 환경에서의 고가용성 시스템 구현 및 결함 내성 시험)

  • Koh, Seok-ju;Son, Jong-young;Kim, Sun-hee;Cho, Hyun-kyung;Bae, Keun-ryeong;Ji, Ho-jun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.74-77
    • /
    • 2019
  • Many enterprises and public institutions are building their own server stabilization system. Nevertheless, many web servers including some public institutions have frequent obstacles due to the unexpected causes such as traffic concentration. Data loss during each of these situations and business interruption can cause a huge loss. In this study, we propose high-availability Web system that uses load balancing and session clustering. Each deals with the failure due to the over traffic by distributing incoming requests in the multiplexed web server and provides the continuous services by maintaining session information of the users in case of the failure of some servers.

  • PDF

Study on the Performance Evaluation of Smart Heating and Cooling Heat Pump System in a Balancing Well Cross-Conditioned Ground Heat Exchanger (Balancing Well 교차혼합 지중열교환기의 스마트 냉난방 히트펌프 시스템의 성능평가에 관한 연구)

  • Lee, Changhee;Kim, Donggyu;Yu, Byeoungseok;Kim, Booil
    • New & Renewable Energy
    • /
    • v.16 no.4
    • /
    • pp.41-48
    • /
    • 2020
  • This study performed a single hole operation method using a balancing well-cross-mixed underground heat exchanger, and conducted thermal performance studies of an SCW-type underground heat exchanger using a two-well. The study attempted to change the existing operating method of the two adjacent SCW underground heat exchangers with one ball each. The SCW-type geothermal heat exchanger is considered to enable up to 20% of bleed discharge at maximum load, which makes groundwater usage unequal. The efficiency factor of the geothermal system was improved by constructing the discharged water by cross-mixing two balancing wells to prevent the discharge of groundwater sources and keep the temperature of the underground heat exchanger constant. As a result of the cooling and heating operation with the existing SCW heat exchange system and the balancing well-cross-mixed heat exchange system, the measured performance coefficient improved by 23% and 12% in cooling and heating operations, respectively. In addition, when operating with a balanced cross-mixing heat exchange system, it has been confirmed that the initial basement temperature is constant with a standard deviation of 0.08 to 0.12℃.

Measuring gameplay similarity between human and reinforcement learning artificial intelligence (사람과 강화학습 인공지능의 게임플레이 유사도 측정)

  • Heo, Min-Gu;Park, Chang-Hoon
    • Journal of Korea Game Society
    • /
    • v.20 no.6
    • /
    • pp.63-74
    • /
    • 2020
  • Recently, research on automating game tests using artificial intelligence agents instead of humans is attracting attention. This paper aims to collect play data from human and artificial intelligence and analyze their similarity as a preliminary study for game balancing automation. At this time, constraints were added at the learning stage in order to create artificial intelligence that can play similar to humans. Play datas obtained 14 people and 60 artificial intelligence by playing Flippy bird games 10 times each. The collected datas compared and analyzed for movement trajectory, action position, and dead position using the cosine similarity method. As a result of the analysis, an artificial intelligence agent with a similarity of 0.9 or more with humans was found.

Case study of property extraction and utilization model for the game player models (게임 플레이어 모델을 위한 속성 추출과 모델 활용 사례)

  • Yoon, Taebok;Yang, Seong-Il
    • Journal of Korea Game Society
    • /
    • v.21 no.6
    • /
    • pp.87-96
    • /
    • 2021
  • As the industry develops, the technology used for games is also being advanced. In particular, AI technology is used to game automation and intelligence. These game player patterns are widely used in online games such as player matchmaking, generation of friendly or hostile NPCs, and balancing of game worlds. This study proposes a model generation method for game players. For model generation, attributes such as hunting, collection, movement, combat, crisis management, production, and interaction were defined, and patterns were extracted and modeled using decision tree method. To evaluate the proposed method, we used the game log of a commercial game and confirmed the meaningful results.

Coupled Inductor Based Voltage Balancing in Dual-Output CLL Resonant Converter for Bipolar DC Distribution System (양극성 DC 배전 시스템 적용을 위한 결합 인덕터 기반의 전압 밸런싱 이중 출력 CLL 공진형 컨버터)

  • Lee, Seunghoon;Kim, Jeonghun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.4
    • /
    • pp.348-355
    • /
    • 2022
  • A bipolar DC distribution system suffers from an imbalance in voltages when asymmetric loads are connected at the outputs. Dedicated voltage balancers are required to address the imbalance in bipolar voltage levels. However, additional components eventually increase the cost and decrease the efficiency and power density of the system. Therefore, to deal with the imbalance in output voltages without adding any extra components, this study presents a coupled inductor-based voltage balancing technique with a dual-output CLL resonant converter. The proposed coupled inductor does not require extra magnetic components to balance the output voltages because it is the result of resonant inductors of the CLL tank circuit. It can also avoid complex control schemes applied to voltage balancing. Moreover, with the proposed coupled inductor, the CLL converter acquires good features including zero voltage and zero current switching. Detailed analysis of the proposed coupled inductor is presented with different load conditions. A 3.6-kW hardware prototype was built and tested to validate the performance of the proposed coupled inductor-based voltage balancing technique.

High Efficiency Voltage Balancing Dual Active Bridge Converter for the Bipolar DC Distribution System (양극성 DC 배전 시스템을 위한 고효율 전압 밸런싱 듀얼 액티브 브리지 컨버터)

  • Lee, Minsu;Cheon, Sungmoon;Choi, Dongmin;Moon, Gun-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.391-396
    • /
    • 2022
  • In this study, a new voltage-balancing dual-active bridge converter that integrates a DAB converter with a voltage balancer is proposed for a bipolar DC distribution system. The proposed converter is configured to connect two loads to the transformer secondary center tap of the DAB converter, and no additional components are added. The proposed converter has the same operation as the conventional DAB converter, and it makes both output voltages similar. Moreover, the imbalanced current offset between the two loads is bypassed only on the secondary side of the transformer. Consequently, the proposed converter integrates a voltage balancer without any additional components, and no additional loss occurs in the corresponding components. Thus, high efficiency and high power density can be achieved. The feasibility of the proposed converter is verified using 3 kW prototypes under 380 V input and 190/190 V output conditions.

The Steel Coil Loading and Placement Automation System Development (철강 코일의 선적 및 배치 자동화 시스템 개발)

  • Sang-Hyun, Kim;Woo, Lee;Seung-Hong, Oh;Ju-Wan, Lee;Min-Woo, Son;Won-Jung, Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1259-1266
    • /
    • 2022
  • Stowage planning is an essential process for safe loading by establishing, agreeing on, and systematically implementing a reasonable loading and securing method based on information on cargo, loading/unloading and the ship. In addition, depending on the plan, there may be a difference of about 14% or more in the loading amount per ship, which causes a tolerance rate and leads to an increase in sea freight charges. In this study, work environment and process standards for steel coil shipment, and classification regulations and guidelines related to steel coil shipment were analyzed. In addition, we developed a steel coil loading and placement automation system that derives an optimal loading plan through performance data-based shipping balancing and stability analysis.

Battery Balancing Method using 2-Switch Flyback Converter (2-스위치 플라이백 컨버터를 이용한 배터리 밸런싱 기법)

  • Kim, Woo-Joon;Kim, Ui-Jin;Park, Seong-Mi;Park, Sung-Jun;Son, Gyung-Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.451-459
    • /
    • 2022
  • Recently, in accordance with the demand for a large capacity of a secondary battery according to an increase in the demand for energy storage devices, a modular series battery configuration is essential. Accordingly, various cell balancing techniques have been proposed to prevent high efficiency and performance degradation of the battery. In this paper, propose a battery voltage balancing topology consisting of a flyback DC/DC converter type of a SIMO (Single-Input-Multiple Output) two-switch configuration for a series battery configuration. The proposed topology shows a structure in which a DC/DC converter connected to each module and a battery cell share one transformer. The topology cell balancing operation is a principle in which the voltage balancing converter of the battery converges to the same value through a transformer that shares a magnetic flux with the cells constituting the module through a single high-frequency transformer. In this paper, the dynamic characteristics analysis of the proposed circuit using PSIM was based and it was verified through experiments on one module.