• Title/Summary/Keyword: 배출저감

Search Result 1,312, Processing Time 0.031 seconds

Assessment of Strategy and Achievements of Eco Industrial Park (EIP) Initiative in Korea (우리나라 생태산업단지 구축사업의 추진전략과 성과평가)

  • Park, Jun-Mo;Kim, Hyeong-Woo;Park, Hung-Suck
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.12
    • /
    • pp.803-812
    • /
    • 2014
  • This study assesses the strategy and performance of Eco-industrial Park (EIP) initiative implemented by Korea Industrial Complex Corporation (KICOX) with the support of Ministry of Trade, Industry and Energy (MOTIE), Korea since 2005 to 2013 and recommends future directions. After the concept of EIP based on industrial symbiosis (IS) is introduced, the background and implementation procedure of the EIP initiative are described. Then, economic and environmental achievement was assessed. During the project periods (2005-2013), 449 industrial symbiosis project were explored, among which 296 projects have been implemented. Among (Of these 296 projects,) them, 244 projects have been completed in which 118 projects have been commercialized which shows 48% commercialization rate of the completed projects. Through these commercialized projects, around 311.1 billion won/year of economic benefits and reduction of waste by-products of 828,113 tons/year, wastewater of 215,517 tons/year, reduction in energy consumption of 250,475 toe/year and GHG emission reduction of 1,107,189 $tCO_2/year$ were achieved. This results confirmed that EIP initiative based on industrial symbiosis can enhance eco-efficiency of industrial parks and harmonize economy and environment. However, there are obstacles like absence of interagency coordination and cooperation, laws and institutional barriers, increased demand for local governments, funding for project investment. Thus, to utilize EIP initiative as a strategic tool for competiveness and environmental management of industrial parks, it needs intergovernmental collaboration and interdisciplinary approach to lower barrier in implementation.

Analysis of Modality and Procedures for CCS as CDM Project and Its Countmeasures (CCS 기술의 CDM 사업화 수용에 대한 방식과 절차 분석 및 대응방안 고찰)

  • Noh, Hyon-Jeong;Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.3
    • /
    • pp.263-272
    • /
    • 2012
  • Carbon dioxide, emitted by human activities since the industrial revolution, is regarded as a major contributor of global warming. There are many efforts to mitigate climate change, and carbon dioxide capture and geological storage (CCS) is recognized as one of key technologies because it can reduce carbon dioxide emissions from large point sources such as a power station or other industrial installation. The inclusion of CCS as clean development mechanism (CDM) project activities has been considered at UNFCCC as financial incentive mechanisms for those developing countries that may wish to deploy the CCS. Although the Conference of the Parties serving as the Meeting of the Parties to the UNFCCC's Kyoto Protocol (CMP), at Cancun in December 2010, decided that CCS is eligible as CDM project activities, the issues identified in decision 2/CMP.5 should be addressed and resolved in a satisfactory manner. Major issues regarding modalities and procedure are 1) Site selection, 2) Monitoring, 3) Modeling, 4) Boundaries, 5) Seepage Measuring and Accounting, 6) Trans-Boundary Effects, 7) Accounting of Associated Project Emissions (Leakage), 8) Risk and Safety Assessment, and 9) Liability Under the CDM Scheme. The CMP, by its decision 7/CMP.6, invited Parties to submit their views to the secretariat of Subsidiary Body for Scientific and Technological Advice (SBSTA), SBSTA prepared a draft modalities and procedure by exchanging views of Parties through workshop held in Abu Dhabi, UAE (September 2011). The 7th CMP (Durban, December 2011) finally adopted the modalities and procedures for CCS as CDM project activities (CMP[2011], Decision-/CMP.7). The inclusion of CCS as CDM project activities means that CCS is officially accredited as one of $CO_2$ reducing technologies in global carbon market. Consequently, it will affect relevant technologies and industry as well as law and policy in Korea and aboard countries. This paper presents a progress made on discussion and challenges regarding the issue, and aims to suggest some considerations to policy makers in Korea in order to demonstrate and deploy the CCS project in the near future. According to the adopted modalities and procedures for CCS as CDM project activities, it is possible to implement relevant CCS projects in Non-Annex I countries, including Korea, as long as legal and regulatory frameworks are established. Though Korea enacted 'Framework Act on Low Carbon, Green Growth', the details are too inadequate to content the requirements of modalities and procedures for CCS as CDM project. Therefore, it is required not only to amend the existing laws related with capture, transport, and storage of $CO_2$ for paving the way of an prompt deployment of CCS CDM activities in Korea as a short-term approach, but also to establish the united framework as a long-term approach.

Heating Performance Analysis of the Heat Pump System for Agricultural Facilities using the Waste Heat of the Thermal Power Plant as Heat Source (발전소 폐열을 이용한 농업시설용 히트펌프시스템의 난방 성능 분석)

  • Kang, Youn Koo;Kang, Suk Won;Paek, Yee;Kim, Young Hwa;Jang, Jae Kyung;Ryou, Young Sun
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.317-323
    • /
    • 2017
  • In this study, the heating performance and the energy saving effect of the heat pump system using hot waste water(waste heat) of the thermal power plant discharged from a thermal power plant to the sea were analyzed. The greenhouse area was $5,280m^2$ and scale of the heat pump system was 120 RT(Refrigeration Ton), which was divided into 30 RT, 40 RT and 50 RT. The heat pump system consisted of the roll type heat exchangers, hot waste water transfer pipes, heat pumps(30, 40, 50 RT), a heat storage tank and fan coil units. The roll type heat exchangers was made of PE(Poly Ethylene) pipes in consideration of low cost and durability against corrosion, because hot waste water(sea water) is highly corrosive. And the heating period was 5 months from October to February. During the heating performance test(12 hours), the inlet water temperature of evaporator was changed from $32^{\circ}C$ to $26^{\circ}C$, and heat absorption of he evaporator was changed from 175 kW to 120 kW. The inlet water temperature of the condenser rose linearly from $15^{\circ}C$ to $50^{\circ}C$, and the heat release of condenser was reduced by 40 kW from 200 kW to 160 kW. And the power consumption of the heat pump system increased from 30 kW to 42 kW. When the inlet water temperature of condenser was $15^{\circ}C$, the heating COP(Coefficient Of Performance) was over 7.0. When it was $30^{\circ}C$, it dropped to 5.0, and when it was above $40^{\circ}C$, it decreased to less than 4.0. It was analyzed that the reduction of heating energy cost was 87% when compared to the duty free diesel that the carbon dioxide emission reduction effect was 62% by recycling the waste heat of the thermal power plant as a heat source of the heat pump system.

Comparison of Greenhouse Gas Emission from Liquid Swine Manure According to Aeration Levels in Summer (돈분뇨 액비의 폭기수준에 따른 여름철 온실가스 배출량 비교)

  • Choi, Dong-Yoon;Park, Kyu-Hyun;Cho, Sung-Back;Yang, Seong-Hak;Hwang, Ok-Hwa;Kwag, Jung-Hoon;Ahn, Hee-Kwon;Yoo, Yong-Hee
    • Journal of Animal Environmental Science
    • /
    • v.17 no.3
    • /
    • pp.163-170
    • /
    • 2011
  • This study was carried out to investigate greenhouse gas (GHG), $CH_4$ and $N_2O$, emission from liquid swine manure according to aeration levels in summer. To evaluate the influence of operation methods on GHG emissions, liquid swine manure were applied with different rates of aeration (store without aeration, $1m^3/ton/h$, $2.5m^3/ton/h$, and $5m^3/ton/h$). Following are the results of this study. The liquid swine manure applied no aeration, $1m^3/ton/h$, $2.5m^3/ton/h$, and $5m^3/ton/h$ aeration rates released 315.6, 13.9, 17.9 and $9.6{\mu}g/m^2/s$ of $CH_4$ and 0.173, 0.157, 0.131, and $0.241{\mu}g/m^2/s$ of $N_2O$, respectively. Liquid swine manure applied no aeration released the most amount of GHG ($6,681.4{\mu}g/m^2/s$ $CO_2$-Eq.) and followed by $5m^3/ton/h$ ($276.4{\mu}g/m^2/s$ $CO_2$-Eq.), $2.5m^3/ton/h$ ($416.0{\mu}g/m^2/s$ $CO_2$-Eq.), and $1m^3/ton/h$ ($340.8{\mu}g/m^2/s$ $CO_2$-Eq.). Our results reveal that the aerated system may reduce GHG emissions compared to no aeration. Consequently, aeration and mixing were effective at reducing GHG emissions during liquid swine manure storage.

Contamination of the Mushim-Cheon and its Countermeasure;II. The Status of the Seasonal and Hourly Contamination of the Water(1989${\sim}$1990)-Temperature, pH, DO, BOD, COD, SS, Turbidity, and BOD Load (무심천(無心川) 수질(水質) 오염(汚染) 실태(實態)와 그 방지책(防止策);II. 계절별(季節別) 및 시간별(時間別) 현황(現況) (1989-1990)-수온, pH, DO, BOD, COD, SS, 탁도 및 BOD 부하량(負荷量))

  • Lee, Jae-Koo;Kim, Hak-Nam;Kyung, Kee-Sung;Kwak, Hee-In
    • Korean Journal of Environmental Agriculture
    • /
    • v.10 no.1
    • /
    • pp.33-49
    • /
    • 1991
  • In order to disclose the contamination of the Mushim-Cheon by pollutants and to establish the countermeasures, the water samples collected in November of 1989(lst sample), February(2nd), May(3rd) and August of 1990(4th) were analyzed to obtain the following results : 1. The water temperatures of the seasonal samples ranged from 8.6 to 16.2, 8.3 to 25.2, 18 to 26, and 24 to 32$^{\circ}C$, in the 1st, 2nd , 3rd, and 4th samples, respectively. 2. The pHs of all the samples ranged from 6.5 to 8.5. 3. In the 3rd sample, especially, DO was observed to fall down to 0.8 ppm at the downstream of St 13, which is not allowed even for agricultural use. 4. The BOD and COD values in sewers were much higher than those in the main stream, and especially the values of St 14-A reached 107-608 and 176-635 ppm, respectively, which far exceeded the limit of 40 ppm, the allowed value for the discharges from the disposal facilities. The SS value of St 14A ranged from 142 to 1, 900 ppm, which far exceeded the limit of 70 ppm, the allowed value for the discharges from the disposal facilities. 5. It turned out that the water quality of the Mushim-Cheon flowing through Cheong Ju was more worsened at sewers than the main stream, and at the downstream than the upstream of the surveyed area. Accordingly, the sewage disposal plant and the expansion of the disposal facilities are urgently needed.

  • PDF

Concentration Levels and Distribution Characteristics of Polycyclic Aromatic Hydrocarbons (PAHs) at Ambient Air in Industrial Complex Area (공단지역 대기 중 다환방향족탄화수소화합물(PAHs)의 농도수준 및 분포특성)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Cho, Sang-Won;Ok, Gon;Shon, Byung-Hyun;Lee, Kwan;Lim, Hyun-Sul
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.379-388
    • /
    • 2011
  • The purpose of this study was to investigate the concentration levels, distribution characteristics and blood concentration of Polycyclic Aromatic Hydrocarbons (PAHs) at ambient air in Industrial Complex Area. The samples were collected at 4 sites in Industrial Complex Area and its vicinities. The result indicated that there was the difference of PAHs concentration as followed local characteristics. The level of average concentration of PAHs in the air in Industrial Complex Area was $14.52{\sim}193.48ng/m^3$. The level of average concentration of six materials with possibility of cancer creation was $1.65{\sim}13.44ng/m^3$. The concentrations of PAHs were generally low, but Jechul-dong is considered an area where consistent monitoring of PAHs is required. In addition, benzo(a)pyrene was detected in every atmospheric sample, however the concentration was not high. The level of concentration of benzo(a)pyrene in the air in the Jechul-dong was $2.89ng/m^3$. But, the concentration of the PAHs in Jechul-dong showed that the Benzo(a)pyrene concentration is above $1ng/m^3$ of air quality standard(EU). The results of the concentration level of PAHs in the blood from 240 persons who were exposed directly were surveyed, it was $1.12{\sim}11.45ng/m^3$ for man and $1.20{\sim}26.89ng/m^3$ for woman. It was indicated that the difference between the genders was very little. The accumulation inside human was anticipated as the PAHs concentration in the blood for the aged was very high. Industrial Complex Area and its vicinities are an area which has been greatly influenced by PAHs and environmental contaminants. It is necessary to control the emission sources of PAHs and to construct an observation system at Industrial Complex Area from now on. It is time to reduce the risk factors for health and environmental disease to protect the health of resident in Industrial Complex Area and its vicinities.

Optimum Synthesis Conditions of Coating Slurry for Metallic Structured De-NOx Catalyst by Coating Process on Ship Exhaust Gas (선박 배연탈질용 금속 구조체 기반 촉매 제조를 위한 코팅슬러리 최적화)

  • Jeong, Haeyoung;Kim, Taeyong;Im, Eunmi;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.24 no.2
    • /
    • pp.127-134
    • /
    • 2018
  • To reduce the environmental pollution by $NO_x$ from ship engine, International maritime organization (IMO) announced Tier III regulation, which is the emmision regulation of ship's exhaust gas in Emission control area (ECA). Selective catalytic reduction (SCR) process is the most commercial $De-NO_x$ system in order to meet the requirement of Tier III regulation. In generally, commercial ceramic honeycomb SCR catalyst has been installed in SCR reactor inside marine vessel engine. However, the ceramic honeycomb SCR catalyst has some serious issues such as low strength and easy destroution at high velocity of exhaust gas from the marine engine. For these reasons, we design to metallic structured catalyst in order to compensate the defects of the ceramic honeycomb catalyst for applying marine SCR system. Especially, metallic structured catalyst has many advantages such as robustness, compactness, lightness, and high thermal conductivity etc. In this study, in order to support catalyst on metal substrate, coating slurry is prepared by changing binder. we successfully fabricate the metallic structured catalyst with strong adhesion by coating, drying, and calcination process. And we carry out the SCR performance and durability such as sonication and dropping test for the prepared samples. The MFC01 shows above 95% of $NO_x$ conversion and much more robust and more stable compared to the commercial honeycomb catalyst. Based on the evaluation of characterization and performance test, we confirm that the proposed metallic structured catalyst in this study has high efficient and durability. Therefore, we suggest that the metallic structured catalyst may be a good alternative as a new type of SCR catalyst for marine SCR system.

A Study on the Environmental Characteristics of Water Quality and Sediments in Suncheon Bay (순천만 수저질 환경특성에 관한 연구)

  • Park, Sangsook;Heo, Sung-sil;Choi, Jeong-min;Woo, Sung-won
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.10a
    • /
    • pp.9-10
    • /
    • 2019
  • 순천만은 순천시의 남쪽에 위치하여 여수반도와 고흥반도의 사이에 있는 만 지형 형태로 만 전체를 순천만이라고도 하나, 보통 고흥군반도와 여수반도 사이의 만을 여자만이라 하고 만내부에 위치한 여자도라는 섬의 위쪽으로 순천시의 해안하구에 형성된 지역을 순천만이라 일컫는다. 순천만은 순천시에서 유입되는 동천과 이사천 및 해룡천의 하류에 형성되어 있어서 육지부에서 유입되는 퇴적물과 유기물로 인하여 갯벌과 갈대등이 잘 형성된 습지로서 2003년 12월 31일 해양수산부 갯벌 습지보존지역으로 지정되어 관리되고 있으며, 2004년에는 동북아 두루미 보호 국제네트워크에 가입하였고, 2006년 1월 국내 연안습지로는 최초로 람사르협약에 "Suncheon Bay"로 등록되었으며, 2016년 6월에는 람사르습지로 지정된 국내외적으로 중요한 습지이다. 순천만습지에 형성되어 있는 갯벌($28.0km^2$)은 세계 5대 연안습지 중 하나로서, 넓은 사니질 갯벌과 갈대군락이 잘 발달되어 있는 생태계의 보고(寶庫)이자 소중한 생태자원으로서, 순천시에서는 순천만을 자연생태공원으로 지정하여 보호 관리하고 있으며, 각종 자연학습자료들과 영상물들을 갖춘 생태전시관과 갈대숲 탐방로, 용산전망대, 야생화 정원, 담수습지, 갈대정자, 갯벌관찰대 등 사계절 생태체험을 위한 각종 시설들을 잘 갖춰놓고 많은 관광객의 이용할 수 있도록 하고 있다. 갯벌은 바닷가의 넓은 벌판이란 뜻으로서 삼면이 바다인 우리나라는 갯벌의 전체 면적이 약 $2,500km^2$에 달하는데 여기에는 많은 종류의 다양한 생물들이 살아가고 있으며 어민들의 생계에 지대한 영향을 주고있다. 이러한 갯벌은 퇴적된 입자의 구성에 따라 펄갯벌, 모래갯벌, 혼합갯벌 등으로 구별되는데 이에 따라 갯벌 생태계를 구성하고 있는 생물들의 종류도 바뀌게 된다. 순천만갯벌과 여기에 조성되어 있는 습지환경에 따라 확인되고 있는 수산자원으로는 새꼬막, 꼬막, 눈알고둥, 갯고둥, 비툴이고둥, 돌조개, 접시조개, 새알조개, 가무락조개, 바지락, 우럭, 가재붙이, 방게, 칠게, 농게 등의 저서 생물들과 짱뚱어, 문절망둑 등의 어류가 있으며, 해조류로 우뭇가사리 등이 있고, 인근의 어민들의 어업형태는 꼬막 등 패류의 채취나 종패를 뿌려 일정기간 양성하여 수확하는 양식업, 육상부에서 폐염전 등을 활용한 전어나 새우 등을 양식하는 양식업, 수산물을 직접 손이나 간단한 도구를 이용하여 잡는 맨손 어업 형태가 주를 이루고 있는 것으로 나타나고 있다. 이와 같이 국내외적으로 중요할 뿐만 아니라 인근의 어민들의 생계에도 지대한 영향을 미치고 있는 순천만의 습지는 뻘층이 깊고, 분해성 미생물이 다양하게 서식하여 유기물 분해능력이 뛰어나며, 유기영양분이 풍부하여 우리나라에서 가장 질이 좋은 습지로 평가되고 있으나, 순천시 등 순천만 인근에 거주하고 있는 인간의 활동에 따른 간섭에 많은 영향을 받고 있으며, 이에 따라 끊임없는 생태환경이 변화하고 있어서 순천만의 효율적인 보전 및 지속가능한 이용을 위해서는 생태계에서 가장 기본적인 요소인 수 저질 환경의 지속적이고 체계적인 조사 및 관리가 필요하다. 한편, 오염물질의 70% 이상은 하천이나 강을 통해서 해역으로 유입된다고 알려져 있기 때문에 생태계의 보고(寶庫)라고 알려진 순천만의 지속적인 보존 및 관리를 위해서는 유입수계 하천의 수질현황 및 오염물질의 주요 배출원을 파악하고, 이에 대한 저감대책을 수립할 필요가 있다. 따라서 본 연구는 순천만의 수저질 특성과 여기에 유입되는 하천의 수질환경 현황 및 오염원을 파악함으로써 순천만의 보전을 위한 효율적 관리방안을 제시하는 것을 목적으로 수행되었다. 연구의 결과에 따르면, 순천만의 수질평가지수에 의한 등급(WQI)은 III등급으로 나타나고 있으며, 득량만, 광양만 등에 비해 비교적 높은 유기물 및 T-N, T-P의 농도 분포를 보이고 있는 것으로 조사되었다. 이는 순천만에 유입되는 하수종말처리장의 방류수와 도시하수가 유입되어 그대로 방류되고 있는 해룡천 및 연안에 위치한 어촌으로부터 직접 방류되고 있는 일부 정화조 유출수 등, 다양한 원인에 의한 것으로 판단되며 이들의 관리가 부실할 경우 순천만의 갯벌과 습지의 지속가능한 생태환경유지는 쉽지 않다. 따라서 이를 효율적으로 관리하기 위해서는 순천만 연안의 오염물질 방류를 총량관리로 전환하여 철저히 관리하는 것이 필요할 것으로 판단된다.

  • PDF

The Effect of the Surfactant on the Migration and Distribution of Immiscible Fluids in Pore Network (계면활성제가 공극 구조 내 비혼성 유체의 거동과 분포에 미치는 영향)

  • Park, Gyuryeong;Kim, Seon-Ok;Wang, Sookyun
    • Economic and Environmental Geology
    • /
    • v.54 no.1
    • /
    • pp.105-115
    • /
    • 2021
  • The geological CO2 sequestration in underground geological formation such as deep saline aquifers and depleted hydrocarbon reservoirs is one of the most promising options for reducing the atmospheric CO2 emissions. The process in geological CO2 sequestration involves injection of supercritical CO2 (scCO2) into porous media saturated with pore water and initiates CO2 flooding with immiscible displacement. The CO2 migration and distribution, and, consequently, the displacement efficiency is governed by the interaction of fluids. Especially, the viscous force and capillary force are controlled by geological formation conditions and injection conditions. This study aimed to estimate the effects of surfactant on interfacial tension between the immiscible fluids, scCO2 and porewater, under high pressure and high temperature conditions by using a pair of proxy fluids under standard conditions through pendant drop method. It also aimed to observe migration and distribution patterns of the immiscible fluids and estimate the effects of surfactant concentrations on the displacement efficiency of scCO2. Micromodel experiments were conducted by applying n-hexane and deionized water as proxy fluids for scCO2 and porewater. In order to quantitatively analyze the immiscible displacement phenomena by n-hexane injection in pore network, the images of migration and distribution pattern of the two fluids are acquired through a imaging system. The experimental results revealed that the addition of surfactants sharply reduces the interfacial tension between hexane and deionized water at low concentrations and approaches a constant value as the concentration increases. Also it was found that, by directly affecting the flow path of the flooding fluid at the pore scale in the porous medium, the surfactant showed the identical effect on the displacement efficiency of n-hexane at equilibrium state. The experimental observation results could provide important fundamental information on immiscible displacement of fluids in porous media and suggest the potential to improve the displacement efficiency of scCO2 by using surfactants.

Development of Summer Leaf Vegetable Crop Energy Model for Rooftop Greenhouse (옥상온실에서의 여름철 엽채류 작물에너지 교환 모델 개발)

  • Cho, Jeong-Hwa;Lee, In-Bok;Lee, Sang-Yeon;Kim, Jun-Gyu;Decano, Cristina;Choi, Young-Bae;Lee, Min-Hyung;Jeong, Hyo-Hyeog;Jeong, Deuk-Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.246-254
    • /
    • 2022
  • Domestic facility agriculture grows rapidly, such as modernization and large-scale. And the production scale increases significantly compared to the area, accounting for about 60% of the total agricultural production. Greenhouses require energy input to create an appropriate environment for stable mass production throughout the year, but the energy load per unit area is large because of low insulation properties. Through the rooftop greenhouse, one of the types of urban agriculture, energy that is not discarded or utilized in the building can be used in the rooftop greenhouse. And the cooling and heating load of the building can be reduced through optimal greenhouse operation. Dynamic energy analysis for various environmental conditions should be preceded for efficient operation of rooftop greenhouses, and about 40% of the solar energy introduced in the greenhouse is energy exchange for crops, so it should be considered essential. A major analysis is needed for each sensible heat and latent heat load by leaf surface temperature and evapotranspiration, dominant in energy flow. Therefore, an experiment was conducted in a rooftop greenhouse located at the Korea Institute of Machinery and Materials to analyze the energy exchange according to the growth stage of crops. A micro-meteorological and nutrient solution environment and growth survey were conducted around the crops. Finally, a regression model of leaf temperature and evapotranspiration according to the growth stage of leafy vegetables was developed, and using this, the dynamic energy model of the rooftop greenhouse considering heat transfer between crops and the surrounding air can be analyzed.