• Title/Summary/Keyword: 배기 덕트

Search Result 75, Processing Time 0.031 seconds

Control Method to Ensure Uniform Exhaust Function by Household of Apartment House (공동주택의 세대별 균등 배기량을 확보 하는 제어방법에 관한 연구)

  • Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.12
    • /
    • pp.628-637
    • /
    • 2017
  • This study was conducted to present an effective control method for the common duct system to uniformly discharge volume flow rate exhausted from the kitchen and bathroom of each household in an apartment regardless of the position of household. Since the common duct system is installed vertically and the ventilator is installed in the terminal, the static pressure of each household decreases when vertical height increases. Therefore, the volume flow rate exhausted from each household is different. In order to improve such a phenomenon, a constant air volume damper shall be installed in a branch duct coupled with a common vertical duct system. The selected ventilator should also be able to handle the maximum volume flow rate considering diversity factor. Therefore, a uniform volume flow rate must be exhausted from all households where the hood is operated. This paper mainly focuses on suggestion of an optimum exhaust control method by comparing exhaust performance of each household according to the presence or absence of a constant air volume damper.

Study on the Performance Improvement of Roof Fan Used for Local Exhaust System Installed in Apartment (공동주택의 국소배기용 루프팬 성능개선에 관한 연구)

  • Kwon, Yong-Il;Jeong, Yeol-Wha;Ahn, Jung-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.136-141
    • /
    • 2012
  • Performance improvement of local exhaust system used in toilet and cooking place are main concern in a field of ventilation. In Korea, There are many high riser residential apartments in recent years. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depends on stack effect. This study investigates on the performance improvement of terminal device, roof fan, of vertical spiral duct used in high riser residential apartments. This paper focuses mainly on the effect of accessories, number or shape of blades, composed of roof fan with function of exhaust air volume of toilet and cooking place. Roof fan with 10 blades is observed at optimum exhaust performance in this study.

Analysis of Air Flow Rate Distribution for the Bathroom Exhaust System in High-rise Buildings Using T-method (T-method를 이용한 고층 아파트 욕실 배기 시스템의 층별 유량분배 해석)

  • 문종선;강석윤;이승철;유호선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.265-272
    • /
    • 2004
  • Based on the T-method, a new scheme for predicting air flow rate distribution in a bathroom exhaust system is developed. Introduction of individual duct route enables us to disintegrate a complicated multi-fan ductwork into a set of simultaneous single-fan subsystems. The scheme is validated via the analysis of a well-posed test problem, showing physical consistency. In order to demonstrate the utility and capability of our method, the bathroom ventilation system in a 20-story residential building is selected as an example. Under the typical design condition, the air flow rate of each exhaust fan at the balancing point is successfully predicted, and such information can lead to an engineering estimation for the overall system performance. While some deficiencies in ventilation are found at bathrooms at lower floors with 6mmAq-rated exhaust fans, they disappear over the whole building by using fans of enhanced static pressures, 7 and 8mmAq. Finally the present scheme seems to be useful for practical design of multi-branched, multi-fan ventilation systems.

A Study on Optimal Ventilation Design for Gas Boxes Installed in Semiconductor Manufacturing Equipment Handling Flammable Liquids (인화성 가스를 취급하는 반도체 제조장비에 설치된 가스박스 최적 환기 설계에 대한 연구)

  • Gyu Sun Cho;Sang Ryung Kim;Won Baek Yang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.63-69
    • /
    • 2023
  • Although Korea is the world's No. 1 semiconductor producing country, most studies are conducted with risk assessment for simple material risks due to the closedness of the site for industrial protection. In terms of industrial safety, a monitoring system such as a gas detector to determine the leakage of hazardous substances has been established, but research on effectively discharging harmful gastritis substances in case of leakage has only recently begun. Semiconductor manufacturing facilities (gas boxes) where a large amount of flammable materials are handled are currently being safety managed by using a gas detector and blocking the air inlet. It is difficult to dilute in a short time in case of leakage of flammable substances. Therefore, in this study, based on various criteria, the size of the duct according to the size of the gas box is determined and the appropriate size of the air inlet is studied to minimize the exhaust performance requirement without exposing hazardous chemicals to the outside in the event of a flammable leak. We want to do an optimal exhaust design.

A Study on Regulation Improvement of Local Ventilation System (국소배기장치의 규제개선에 관한 연구)

  • kim, Nam Suk;Kim, Young Suk;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.74-83
    • /
    • 2018
  • Anyone who wants to install local ventilation system must obtain a permission from the Ministry of Employment and Labor even if he has permission from the Ministry of Environment. This is because not only the Atmospheric Environmental Protection Act, but also the manufacturing industry's hazardous risk prevention plan under Article 48 Clause 2 of the Industrial Safety and Health Act is to be submitted by 15 days before the construction. Under the current Environmental Protection Act, the Ministry of Environment regulates only the emission of pollutants from local exhaust ventilation systems into the atmosphere and the contents of workers' safety and health within industrial sites are managed by the Ministry of Employment and Labor. Even with the approval of the Ministry of Environment, the number of unsuccessful cases by the Ministry of Employment and Labor has increased, causing a growing discontent among the sites due to production delays and additional costs of improvement. In addition, local exhaust systems that are at greater risk of fire explosion have increased the risk of severe industrial accidents due to fire explosion. This is due to insufficient design of air volume, control speed, return speed, duct size, and risk of fire explosion. This is because the criteria and procedures for approval of local exhaust ventilation systems are similar, but the Industrial Safety and Health Act adds additional screening items for safety and safety of workers and fire and explosion. In this study, the Environment Ministry and the Employment and Labor Ministry seek to find a reasonable way to operate the system by comparing local exhaust ventilation system installation approval standards.

A Study on the Ventilation Efficiency of Apartment Housing Bathroom Based on the Flexible Installation Method of Exhaust Fan. (공동주택 욕실 배기팬의 플랙시블 덕트 시공상태에 따른 환기효율에 관한 연구)

  • Lee Kwang Myung;Ham Jin Sik
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.73-79
    • /
    • 2005
  • The ventilation efficiency of apartment housing bathroom has been measured by the flexible's diameter, length, and installation format to the exhaust In. The gas density attenuation method of Tracer Gas Method has been specifically utilized for this measurement. Full size mock-up of apartment housing bathroom, which was approximately $100 m^2$ in size, has been established for the ventilation emciency measurement. In addition, the ventilation efficiency has been studied by the possibility of air-supply In. The diameters of flexible are 100 mm, 125 mm, and 150mm. It also have the length of 1.0m, and 1.5 m. The installation formats are I shape, L shape, and S shape. As a result of this measurement, the flexible which has the highest ventilation efficiency was the one has bigger diameter, short in length, and I shape installation format.

일차원 음장에서의 능동소음제어

  • 남현도
    • Journal of KSNVE
    • /
    • v.5 no.4
    • /
    • pp.461-467
    • /
    • 1995
  • 본 글에서는 일차원 음장에서의 능동소음제어를 위한 적응필터 알고리즘 들 과 이의 응용 예를 주로 다루었다. 앞으로의 세기에서는 환경관련 기술이 산업화의 앞날을 좌우할 수 있는 핵심기술이 될 것이므로 능동소음제어에 관한 연구가 더욱 활발해지리라 예상된다. 공조 시스템에서의 능동소음제어 기술은 미국, 유럽 등지에 서 상품화 된지 10여년이 지났고 국내에서도 수년전에 ANC Technology사에서 상품화 를 하였으나, 아직은 가격이 비싸고 덕트의 크기나 소음원의 특성 등에 따라 성능이 제안을 받고 있어 방송국, 공연장 등 소음이 민감한 곳에서 부분적으로 사용되고 있을 뿐이나 앞으로 프로세서의 가격이 싸지고 좀 더 강인성이 보장된 알고리즘을 개발하여 성능을 향상시킬 경우 많은 응용이 기대된다. 엔진의 배기관에의 응용은 이제 시작 단계에 있으며 발전소 등과 같은 대용량 엔진에서는 어느 정도 실용성이 입증되고 있으나 자동차 엔진 등과 같은 소용량 엔진에서는 시스템의 가격이 지나치 게 비싸 이직은 적용하지 못하고 있어 저 가격화에 대한 연구가 필요하리라 생각된다. 능동소음제어 분야는 미국, 영국, 일본 등 선진국에서도 시작한지 10년 내외되는 신기술 분야로 실제 플랜트에 응용되고 사용 제품을 생산하기 시작한 것은 불과 수년 밖에 안되었으므로 앞으로 더욱 연구가 진행되면 더욱 종은 결과가 기대된다.

  • PDF

The Effect of Temperature and Flow Rate in Hot Exhaust Gas on the NOx Emission and Flame Structure of Diffusion Flame (고온 배기가스의 온도 및 유량이 확산화염의 구조 및 NOx 발생에 미치는 영향)

  • Sohn, H.S.;Jang, S.W.;Kim, H.Y.
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.139-146
    • /
    • 2001
  • The experimental study was carried out for the diffusion flame characteristics of second stage combustor with the variations of temperature and supplying rate of hot exhaust gas from first stage combustor. It also examined the flame structure and NOx formation of the second stage combustor in which the fuel(natural gas) is supplying into the mixture of oxygen hot exhaust gas from first stage combustor. The results show that the increasement of temperature and flow rate of exhaust gas lead to increase the NOx up to 30ppm with 19% $O_2$ condition

  • PDF

A study of method to refrain from the winding temperature rising of three-phase induction motor (고압전동기 권선온도 냉각설비 개선 사례 연구)

  • Choi, In-Seok;Hong, Jeong-Jo;Lee, Eun-Chun;Hong, Young-Jae;Hong, Hyun-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.831-832
    • /
    • 2015
  • K-water에서는 대청댐 하류의 용수를 취수하여 대청광역 계통에 1일 98만㎥을 공급할수 있는 현도취수장을 운영하고 있다. 취수장에는 고압전동기 10대가 운영되고 있으며, 장시간 연속운전 및 하절기 주위온도 상승 등으로 권선온도가 상승되어 설비의 안전성 문제가 제기되어 왔다. 취수펌프동 실내온도 및 고압전동기 권선온도 저감을 위해 펌프동 배기시스템 운영시간 변경 및 고압전동기 냉각 흡기덕트 설치 등의 개선 노력으로 권선온도 저감은 물론 에너지절감 및 기기의 수명연장 등 설비 운영의 안전성을 확보한 연구결과이다.

  • PDF

Analysis of Exhaust Flow of a Large Scale Fire Calorimeter using CFD Model (CFD 모델을 이용한 화재용 열량계의 유동해석)

  • Kim, Sung-Chan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.53-58
    • /
    • 2010
  • 발열량은 화재현상을 이해하고 화재의 위험도를 평가하는데 있어서 가장 기본이 되는 물리량으로 화재강도를 나타내는 척도로 인식되고 있다. 발열량의 신뢰성은 화재 물성이나 공간화재 특성의 이해뿐만 아니라 화재해석을 통한 위험성 평가에 있어서 중요한 요소이기 때문에 측정의 신뢰성이 매우 중요하다. 본 연구에서는 수치해석 모델을 통하여 화재 발열량계의 배기덕트 구조에 따른 내부 유동특성을 파악하고자 한다. 해석결과를 바탕으로 각 측정점의 위치에 따른 상태오차 정도를 분석하고 산소소모법에 의해 계산된 발열량을 비교한다. 화재 발열량계의 수치해석을 통하여 발열량 산정의 오차특성을 평가함으로써 발열량계 설계 과정을 최적화하고 효과적인 발열량계 운영을 위한 기초자료를 얻는데 기여하고자 한다.

  • PDF