• Title/Summary/Keyword: 배관 감육검사

Search Result 21, Processing Time 0.024 seconds

Defect Detection of the Wall Thinning Pipe of the Nuclear Power Plant Using Infrared Thermography (적외선열화상을 이용한 원자력발전소 감육 배관의 결함 검출)

  • Kim, Kyeong-Suk;Chang, Ho-Sub;Hong, Dong-Pyo;Park, Chan-Joo;Na, Sung-Won;Kim, Kyung-Su;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.85-90
    • /
    • 2010
  • The infrared energy is emitted in the infrared wavelength range that corresponds to the surface temperature of a object which has temperature that is over the absolute the temperature(OK). The infrared thermography (IRT) is a non-destrnctive testing method that provides thermal video for the user in real-time by converting the infrared quantity that is detected by the infrared detector into temperature. The pipes of nuclear power plant(NPP) could be thinned by the corrosion and fatigue and the defect could lead to a big accident. For this reason, the effective non-destructive testing method is necessary. In this study, the relationship between the measured temperature and the defect depth or size of NPP pipes were recognized and that was applied to detect the wall thinning defects of NPP pipes.

Deformation Measurement of Well Thinning Elbow by Using Shearography (전단간섭법을 이용한 감육 곡관부의 변형 계측)

  • Jung, Hyun-Chul;Kim, Koung-Suk;Chang, Ho-Sub;Jung, Sung-Wook;Kang, Ki-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.321-328
    • /
    • 2006
  • In this study, the deformation oi wall thinning elbow is measured and the position of the internal thinning defect is found out by shearography. Shearography is an optical method which has applied to nondestructive testing (NDT) and the strain/stress and deformation analysis. This technique has the merit of the directly measuring the first derivative of displacement with sensitivity which can be adjusted by handling the tilt mirror in the interferometer. In this paper, we tested carbon steel pipe locally wall thinned and loaded internal pressure and the shearography was applied to measure the out-of-plane deformation of wall thinning elbow and to investigate the internal thinning defect of it. From the results, it was confirmed that this technique is proper to the practical application on the pipe line system with internal defect.

Defect Depth Measurement of Straight Pipe Specimen Using Shearography (전단간섭계를 이용한 직관시험편의 결함 깊이 측정)

  • Chang, Ho-Seob;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.170-176
    • /
    • 2012
  • In the nuclear industry, wall thinning defect of straight pipe occur the enormous loss in life evaluation and safety evaluation. To use non-destructive technique, we measure deformation, vibration, defect evaluation. But, this techniques are a weak that is the measurement of the wide area is difficult and the time is caught long. In the secondary side of nuclear power plants mostly used steel pipe, artificiality wall thinning defect make in the side and different thickness make to the each other, wall thinning defect part of deformation measure by using shearography. In addition, optical measurement through deformation, vibration, defect evaluation evaluate pipe and thickness defects of pressure vessel is to evaluate quantitatively. By shearography interferometry to measure the pipe's internal wall thinning defect and the variation of pressure use the proposed technique, the quantitative defect is to evaluate the thickness of the surplus. The amount of deformation use thickness of surplus prediction of the actual thickness defect and approximately 7 percent error by ensure reliability. According to pressure the amount of deformation and the thickness of the surplus through DB construction, nuclear power plant pipe use wall thinning part soundness evaluation. In this study, pressure vessel of thickness defect measure proposed nuclear pipe of wall thinning defect prediction and integrity assessment technology development. As a basic research defected theory and experiment, pressure vessel of advanced stability and soundness and maintainability is expected to contribute foundation establishment.

Development of Portable Vibration Signal-Based Pipe Wall Thinning Inspection Device (진동신호기반 배관감육 측정시스템 개발)

  • Han, Soon-Woo;Park, Jin-Ho;Kang, To;Sohn, Ki Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.545-547
    • /
    • 2014
  • The portable vibration signal-based pipe wall thinning inspection device was developed in this work. Compared to wall-thinning detection using conventional ultrasonic thickness measurement gauge, the proposed device can estimate average wall thickness of wide range and be applied to in-service pipes. The measurement principle of the device was briefly described and the configrations of hardware and software were explained. It was shown that the device can gauge average wall-thickness of test specimens with high precision.

  • PDF

침식부식으로 인한 원전 2차측 배관의 잔여수명 예측 시스템 개발 및 적용

  • 황경모;노희영;진태은
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11b
    • /
    • pp.717-722
    • /
    • 1996
  • 원자력 발전소 2차측 배관에서 가장 심각한 문제로 대두되고 있는 침식부식 현상을 예측/감시하는 시스템을 개발하여 특정 원전 2차 계통의 전 부분을 망라하여 실제 평가를 수행하였으며, 이를 현장에서 초음파검사로 측정한 결과와 비교하였다. 본 시스템으로 평가한 침식부식률을 실제 측정으로 산출한 침식부식률과 비교해 본 결과, 오차 100% 이내에 포함되는 부위가 92%에 달하는 것으로 확인되었다. 본 시스템은 침식부식 이론 및 관련 변수들로부터 단상 및 2상유체 배관의 침식부식률과 ASME 코드 및 BS 코드의 허용기준에 따른 잔여수명을 예측할 수 있으며, 침식부식으로 인한 배관의 두께가 최소허용치 이하로 떨어질 경우에는 국부 배관감육평가를 수행 할 수 있는 시스템의 형태로 개발하였다.

  • PDF

Assessment of Pipe Wall Loss Using Guided Wave Testing (유도초음파기술을 이용한 배관 감육 평가)

  • Joo, Kyung-Mun;Jin, Seuk-Hong;Moon, Yong-Sig
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.295-301
    • /
    • 2010
  • Flow accelerated corrosion(FAC) of carbon steel pipes in nuclear power plants has been known as one of the major degradation mechanisms. It could have bad influence on the plant reliability and safety. Also detection of FAC is a significant cost to the nuclear power plant because of the need to remove and replace insulation. Recently, the interest of the guided wave testing(GWT) has grown because it allows long range inspection without removing insulation of the pipe except at the probe position. If GWT can be applied to detection of FAC damages, it will can significantly reduce the cost for the inspection of the pipes. The objective of this study was to determine the capability of GWT to identify location of FAC damages. In this paper, three kinds of techniques were used to measure the amplitude ratio between the first and the second welds at the elbow area of mock-ups that contain real FAC damages. As a result, optimal inspection technique and minimum detectability to detect FAC damages drew a conclusion.

Development of Leak and Vibration Monitoring System for High Pressure Steam Pipe by Using a Camera (카메라를 이용한 고압 증기 배관 누설/진동 감시시스템 개발)

  • Jeon, Hyeong-Seop;Suh, Jang-Su;Chae, Gyung-Sun;Son, Ki-Sung;Kim, Se-Oh;Lee, Nam-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.496-503
    • /
    • 2016
  • Leakages at plant structures of power and petrochemistry plants have led to casualties and economic losses. These leakages are caused by fatigue failure of pipelines and their wall thickness. Vibration measurement methods for plant pipelines mainly use acceleration and laser sensors. These sensors are difficult to install and operate and thus lead to an increase in operational cost especially for wide area surveillance. Recently, measurements of leak and vibration displacements using cameras have attracted the interest of many researchers. This method has advantages such as simple installation, long distance monitoring, and wide area surveillance. Therefore, in this paper, we have developed a system that can measure the leakage and vibrational displacement by using a camera. Furthermore, the developed system was verified with experimental data.

Evaluation of Thickness Reduction in Steel Plate by Using SH-EMATs (수평횡파 송수신용 EMAT를 이용한 스틸 박판의 두께 감육 평가)

  • Lee, Jin-Hyuk;Park, Ik-Keun;Kim, Yong-Kwon;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.47-52
    • /
    • 2011
  • An electromagnetic acoustic transducer(EMAT) is a non-contact transducer which can transmit the ultrasonic guided waves into specimens without couplant. And it can easily generate specific guided waves such as SH(shear horizontal) or Lamb waves by altering the design of coil and magnet. In this study, the SH wave, which is generated by EMAT, has been applied to estimate the thickness-reduction in a steel plate. Especially, the interesting feature of the dispersive behavior in selected wave modes is used to detect the thickness-reduction. Experimental results show that the reduction-level can be quantified by the measurement of the group velocity of the wave which passes though the thinning area.

Measurement of Inner Defects and out of Plane Deformation of Pressure Vessel in Piping of Circulation System Using Shearography (전단간섭법을 이용한 배관 순환 시스템에서의 압력용기 내부결함 및 면외변형 측정)

  • Kang, Chan-Geun;Kim, Hyun-Ho;Jung, Hyun-Il;Choi, Tae-Ho;Jung, Hyun-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.5
    • /
    • pp.349-355
    • /
    • 2014
  • Wall thinning defects can occur in the pressure vessels used in a variety of industries. Such defects are related to the flow velocity. Considering the fact that such vessels constitute up to 70 or 80% of the plant structures in a power plant, it is important to measure internal defects as part of a safety evaluation. In this study, optical measurement were applied in a non-destructive evaluation using shearography to ensure the safety and improve the reliability of a power plant through the non-contact, non-destructive evaluation of pressure vessels. In order to verify whether the pressure vessels contained faults, experimental and analytical investigation were conducted to measure any internal defects and out-of-plane deformation from inner temperature changes and pressure changes in the piping of the circulation system. The most important factors in this research were the thickness, width, and length of a defect. An increase in these could confirm an increase in the deformation. Thus, internal defects in a pressure vessel were measured using shearography, which made it possible to ensure the reliability and integrity of the pipe.

Design and Array Signal Suggestion of Array Type Pulsed Eddy Current Probe for Health Monitoring of Metal Tubes (금속배관 건전성 감시를 위한 배열형 펄스와전류 탐촉자의 설계 및 배열신호 제안)

  • Shin, Young Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.291-298
    • /
    • 2015
  • An array type probe for monitoring metal tubes is proposed in this paper which utilizes peak value and peak time of a pulsed eddy current(PEC) signal. The probe consists of an array of encircling coils along a tube and the outside of coils is shielded by ferrite to prevent source magnetic fields from directly affecting sensor signals since it is the magnetic fields produced by eddy currents that reflect the condition of metal tubes. The positions of both exciter and sensor coils are consecutively moved automatically so that manual scanning is not necessary. At one position of send-receive coils, peak value and peak time are extracted from a sensor PEC signal and these data are accumulated for all positions to form an array type peak value signal and an array type peak time signal. Numerical simulation was performed using the backward difference method in time and the finite element method for spatial analysis. Simulation results showed that peak value increases and the peak appears earlier as the defect depth or length increases. The proposed array signals are shown to be excellent in reflecting the defect location as well as variations of defect depth and length within the array probe.