• Title/Summary/Keyword: 배관제작

Search Result 159, Processing Time 0.022 seconds

Eddy Current Testing of Weldment by Plus(+) Point Probe (Plus(+) Point Probe를 이용한 용접부 와전류검사)

  • Lee, Hee-Jong;Kim, Yong-Sik;Nam, Mim-Woo;Yoon, Byung-Sik;Kim, Seok-Kon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.6
    • /
    • pp.426-432
    • /
    • 1999
  • A plus-point eddy current test(ECT) probe was developed to examine the defects on the welds of pumps, valves, and pipings which are the major components of the electric power plants, non-destructive evaluation (NDE) techniques for detecting and sizing the flaws were studied adapting this probe. Differential plus-point ECT probe is consists of two "I"-type coils crossed each other and has an advantage having a small influence on the sensitivity by lift-off variation to the conventional types of probe. The specimens with crack-like electro discharge machining(EDM) notches on the weld of type 304 stainless-steel were fabricated in order to evaluate the plus-point ECT probe response to the flaws. NDE techniques to detect and size the flaws and estimate the flaw type were established with this specimens.

  • PDF

Determination of $Ca^{2+}$ by Fiber Optic Fluorosensor Based on the Conformational Change of the Protein Calmodulin (Calmodulin 단백질의 형태변화를 이용한 광섬유 형광센서에 의한 $Ca^{2+}$의 정량)

  • Ri, Chang-Seop;Yang, Seung Tae
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.221-227
    • /
    • 1995
  • The fiber optic fluorosensor that shows a specific selectivity for calcium ion is studied. This sensor employs protein Calmodulin(CaM) which forms a fluorescent chelate with $Ca^{2+}$. A dialysis membrane is used to entrap a fluorescein isothiocyanate-labeled CaM solution at the common end of a bifurcated fiber optic bundle. The sensing mechanism of this sensor is based on the shifts in the fluorescence spectrum of metal-calmodulin complexes which FCaM forms a chelate with $Ca^{2+}$. Upon binding with $Ca^{2+}$, CaM undergoes a conformational change which induces a change in the fluorescence of FCaM. This change in fluorescence signal which is measured by photomultiflier tube is related to the concentration of $Ca^{2+}$ for calibration curve. Detection limit for $Ca^{2+}$ and the interference effects by $Mg^{2+}$, $Eu^{3+}$ and $La^{3+}$ for this sensor are studied. Response time and life time for this fluorosensor are also investigated.

  • PDF

Numerical Simulation of Bullet Impact for Fuel Cell of Rotorcraft (회전익항공기용 연료셀 피탄 수치모사 연구)

  • Kim, Hyun-Gi;Kim, Sung Chan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.5
    • /
    • pp.405-411
    • /
    • 2012
  • Inside a rotorcraft fuel cell, pipes and components are located for fuel storage and fuel supply into the engine. Utility helicopters, operated in battle fields, fly at lower altitude compared to fixed-wing aircraft and hence are more likely to be exposed to gunfire. Since internal pressure of fluid increases when hit, the effect on LRU due to increase in pressure must taken into account when designing the aircraft for survivability. However, it is costly and time consuming to manufacture a fuel cell for gunfire test, and due to constraints from usage of live ammunition, related data gathered through numerical simulation is needed. In this study, numerical simulation on rotorcraft fuel cell exposed to gunfire was carried out using Autodyn to analyze bullet movement inside the fuel cell after hit, and internal pressure of fluid and equivalent stress on fuel cell assessed.

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.

Feasibility Analysis of Exploring Underground Utilities Using Muon (뮤온 입자를 활용한 지하매설물 탐사 가능성 분석)

  • Seo, Seunghwan;Chung, Moonkyung;Kwak, Kiseok;Kang, Jae Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.137-147
    • /
    • 2022
  • Various geophysical exploration methods are used to determine the exact location of underground utilities, and many studies have been performed to improve the accuracy. This study analyzed the feasibility of exploring underground utilities through a new exploration method using cosmic ray muon. A prototype of a portable muon detector was manufactured by combining a scintillator and a silicon photomultiplier. Further, a calibration operation was performed on the muon count rate. The ground thickness of the ground model was measured using the muon detector prototype, where the value could be estimated with an error of about 3%, close to the actual. In addition, the theoretical basis for tomography analysis technology was analyzed to utilize the muon detector for exploring underground utilities, and a zenith angle correction method was presented. This study revealed that the technology of exploration using muon can analyze density with high resolution and will be used for exploring underground utilities.

Tasks for Development of Autogenous Pressurization System and Construction of Test Equipment (자가증기 가압시스템 개발과제 및 모사시험설비 구성)

  • Cheulwoong Kim;Jisung Yoo;Sangyeon Ji;Jae Sung Park
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.49-57
    • /
    • 2023
  • The autogenous pressurization has been widely adopted for propulsion systems of next-generation reusable rockets due to its low cost and high reliability. The autogenous pressurization has a simple structure, but an understanding of the heat and mass transfer occurring inside the tank is essential. For this reason, a simulation test of the autogenous pressurization was conceived. The experiment equipment was constructed based on overseas pressurization test facilities cases and expert advice. Unlike the actual autogenous pressurization system, the propellant tank was insulated to exclude external influences. The pressurized gas supply line and the propellant pipe were separated. Using the manufactured autogenous pressure experiment equipment, it is possible to evaluate the condensation phenomenon of pressurants in cryogenic propellants, comparison of the efficiency of pressurization using helium and evaporated gas and the pressurization capacity according to the temperature of pressurant.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Channel Structure and Header Design of Printed Circuit Heat Exchanger by Applying Internal Fluid Pressure (유체 내압을 고려한 인쇄기판형 열교환기의 채널구조 및 헤더 설계)

  • Kim, Jungchul;Shin, Jeong Heon;Kim, Dong Ho;Choi, Jun Seok;Yoon, Seok Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.767-773
    • /
    • 2017
  • Printed Circuit Heat Exchanger (PCHE) has an advantage for exchanging thermal energy between high-pressure and high-temperature fluids because its core is made by diffusion bonding method of accumulated metal thin-plates which are engraved of flow channel. Moreover, because it is possible that the flow channel can be micro-size hydraulic diameter, the heat transfer area per unit volume can be made larger than traditional heat exchanger. Therefore, PCHE can have higher efficiency of heat transfer. The smaller channel size can make the larger heat transfer area per unit volume. But if high pressure fluid flows inside the channel, the channel wall can be deformed, the structure and shape of flow channel and header have to be designed appropriately. In this study, the design methodology of PCHE channel in high pressure environment based on pressure vessel codes was investigated. And this methodology was validated by computational analysis.

A Study on the Effects of Various Disk Shape of Hydrant on the Pressure Drop (옥외소화전의 디스크 형상을 고려한 압력손실에 관한 연구)

  • You, Woo Jun;Shim, Myoung Gyu;Sung, Kun Hyuk;Yu, Jae Bum;Youm, Moon Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.1-7
    • /
    • 2013
  • In this study, the effects of various disk shapes of hydrant on the pressure drop are experimentally and numerically analyzed. The test methods for measuring pressure drop of hydrant are comply with standard of Underwriters Laboratory (UL). The hydrant as used in this study has one inlet, diameter 150 mm, and three outlet, 114.3 mm diameter for one outlet and 63.5 mm diameter for the others. The pressure of the hydrant are measured in the range 760 L/min~2,270 L/min for 63.5 mm outlet and 3,030 L/min~6,060 L/min for 114.3 mm outlet. Also, the numerical results of pressure drop are compared with the experiments to verify the accuracy and to analyze the of various valve shape of hydrant on the pressure drop. The engineering parameters, flow coefficients, are reduced from 181.57 to 136.35 ($L/min/kPa^{0.5}$) with inclined angle of disk from $0^{\circ}$ to $45^{\circ}$. These results are able to practical use for design hydrant to minimize pressure drop.

Corrosion control technique for pipeline system through injecting water stabilizer (수질안정화 약품 주입에 따른 상수도관 내부 부식제어 특성 연구)

  • Hwang, Byung-Gi;Woo, Dal-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.545-551
    • /
    • 2011
  • Recently, demands for generating high quality tap waters are increasing with high concern of water pollution and corrosion of water pipelines. For the reasons, developing water quality stabilization technique in water purification system is sought rather than replacing to a new pipelines. In this study, high-purity liquid lime($Ca(OH)_2$) was introduced for a water quality stabilization technique in water purification process and simulated water distribution system of pilot-scale size was applied to evaluate anti-corrosion control effect. The effect of anti-corrosion control was calculated in terms of LSI(Langelier Saturation Index) In conclusion, the result of pilot plant showed improvement of corrosiveness by liquid lime($Ca(OH)_2$) with reduction of released iron(Fe). Application of anti-corrosion control technique to the mild steel coupon and the copper coupon were effective by indicating 35.4, 44.5% of improvements. Besides, sample pipes which were treated with liquid lime had formated more thicker layer of corrosion product inside of pipes. As a result, the process of injecting water stabilizer can greatly contribute to the high quality of tap water.