• Title/Summary/Keyword: 배관설치

Search Result 300, Processing Time 0.028 seconds

Installation trend analysis of indoor cable facilities for wireless calls in the elevator (승강기내 무선통화를 위한 구내 선로설비 설치 동향 분석)

  • Cho, Pyung-dong;Choi, Mun-hwan;Lee, Sang-mu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.478-481
    • /
    • 2013
  • Wireless calls in the elevator is necessary for the safety and security of human life. The various method of installation of telecommunications equipment have been used for the current. In this paper, we analyze and compare the each installation method, and to discuss also about the direction of institutional development for this installation issues.

  • PDF

Design of Multistage Orifices for PIC System in Nuclear Reactor (원자로 압력 및 체적제어계통의 다단 오리피스 설계)

  • Shin, J.C.
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.17-21
    • /
    • 2015
  • Restriction orifices in the feed and bleed circuit of nuclear power plant are designed using computer program capable of handling multiple hole cascade orifice assembly. Single hole stages of orifice assembly are alternated with multihole stages where necessary. The distance between stages is such that it allows full pressure recovery. The minimum static pressure is higher than vapor pressure at the operating temperature so that cavitation does not occur. Piping sizes are reviewed and increased if necessary to improve rigidity.

Development of Vacuum Sprinkler Extinguishing System (부압식 스프링클러설비)

  • Oh, Ju-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.61-66
    • /
    • 2011
  • 부압식 스프링클러 설비는 우리나라에서 일반적으로 사용되고 있는 준비작동식이나 건식 또는 습식 스프링클러 설비의 2차측 배관내의 압력을 부압(진공)상태로 유지시켜 오작동(스프링클러 헤드의 파손 또는 배관의 누수) 시에 발생되는 소화수의 누수를 진공압(-0.05~-0.08MPa)으로 흡입하는 구조로 설계되어 수손피해에 대한 위험도를 제거 하여 기존의 스프링클러 시스템의 문제점을 해결 할 수 있는 획기적인 기술로 볼 수 있다. 또한 부압식 스프링클러 설비는 습식, 준비작동식에 해당하는 시설에 모두 적용이 가능하며 매년 국내, 외에서 건설되는 모든 대상물에도 설치가 가능하며 기존 설비된 건물에도 손쉽게 적용이 가능하여 앞으로 IT관련 산업, 반도체 제조공장, 호텔, 학교, 병원, 관공서, 지하철 역사, 정밀가공 제조설비 등 특히 내진설계에 적용되고 있는바 그 적용성이 무궁무진한바 본 부압식 스프링클러 시스템의 연구를 통한 확대에 대한 가능성은 무한할 것으로 예상된다.

  • PDF

영광3,4호기 가압기 밀림관의 파단전 누설 설계(LBB) 타당성

  • 전재풍;정대율
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.753-760
    • /
    • 1995
  • 본 보고서는 영광 3,4호기 가압기 밀림관(Surge Line)에 대한 파단전누설(Leak Before Break) 개념의 적용방법, 해석절차 및 해석결과에 대하여 기술하고 있다. 영광 3,4호기 가압기 밀림관에 대한 파단전누설해석은 배관계에 대한 정적, 동적 배관해석 결과를 토대로 큰 응력 값이 작용하는 부분에 대하여 수행하였다. 가상균열의 크기는 정상운전상태에서의 하중을 이용하여 결정하였으며 격납용기에 설치된 누설감지장치의 감지능력을 1.0gpm으로 가정하였다. 영광 3,4호기 가압기 밀림관에 대한 파단전 누설해석은 NUREG 1061,Vol.3 및 SRP3.6.3에 근거하여 수행하였으며 해석결과는 동 자료에서 제시하고 있는 적용기준을 만족하고 있는 것으로 평가되었다.

  • PDF

A Study on Experimental and Numerical Analysis for Behavior of Multi-layerd Pipeline Subjected to Blasting Vibration (지중 다중 관의 발파 진동 특성 분석을 위한 실험 및 수치해석적 연구)

  • Kim, Moon-Kyum;Won, Jong-Hwa;Noh, Gi-Seok;Cho, Seok-Ho;Kim, Kyung-Min
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.417-420
    • /
    • 2010
  • 지중매설관은 경우에 따라 긴 수송거리를 보이기 때문에 부식 및 충격에 의한 파손 등에 대한 모니터링이 어려운 실정이다. 이러한 조건을 극복하기 위하여 복합관 및 다중관을 설치하고 있으나, 이에 대한 연구는 아직 미비한 실정이다. 본 연구에서는 발파진동원에서 고정된 이격거리, 매설심도에서 배관 상단에 특정 진동속도를 발생시키는 발파 하중을 고려하여, 이격거리에 대한 수치해석을 수행하였으며 장약량에 따른 이격거리와 발파효율을 측정하였다. 실험값과 수치해석 값의 오차는 발파지점에서 가까울수록 크게 나타났으며 발파지점과 마주보는 방향이 반대방향보다 크게 나타났다.

  • PDF

Estimation of Plastic Bending Moment of Offshore Pipelines (해저관로의 대 변형 굽힘에 의한 소성 모멘트 추정)

  • Lee, Jong-Hyun;Choi, Han-Suk
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.20-25
    • /
    • 2002
  • 본 논문은 대 변형 굽힘에 의한 소성 모멘트의 계산시 ovality를 고려한 파이프의 중립축에 대한 모멘트에 관해 논한다. 기존의 계산방법에 의한 중립축에 대한 모멘트 계산결과와 새로운 방법에 의한 계산결과를 비교해 보았다. 파이프가 길이방향의 모멘트에 의하여 굽어질 때, 증가하는 모멘트에 따른 ovality 변화를 고려하여 중립축에 대한 모멘트 계산에 적용해 보았다. 모멘트 계산은 타원형의 파이프 단면을 미세한 단면으로 나누어서 각 단면에 대한 응력을 비선형 strain-stress 식을 이용하여 구한 다음 중립축에 대해 계산을 수행하였다. 대 변형 굽힘에서 일어나는 실제현상 중 하나인 ovality를 파이프의 계산에 적용함으로써 좀 더 정확한 중립축에 대한 모멘트를 계산할 수 있었다. 이 방법을 reel에 의한 해저배관의 설치 공법에서 사용되는 reverse bending radius 계산에 적용해 보았다.

  • PDF

Leak Location Detection of Underground Water Pipes using Acoustic Emission and Acceleration Signals (음향방출 및 가속도 신호를 이용한 지하매설 상수도배관의 누수지점 탐지연구)

  • Lee, Young-Sup;Yoon, Dong-Jin;Jeong, Jung-Chae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.227-236
    • /
    • 2003
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of relevant countermeasures against leaks is to find and repair of leak points of the pipes. Leak noise is a good source to identify the location of leak points of the pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they have not been so efficient tools. In this paper, acoustic emission (AE) sensors and accelermeters are used to detect leak locations which could provide all easier and move efficient method. Filtering, signal processing and algorithm of raw input data from sensors for the detection of leak location are described. A 120m-long pipeline system for experiment is installed and the results with the system show that the algorithm with the AE sensors and accelerometers offers accurate pinpointing of leaks. Theoretical analysis of sound wave propagation speed of water in underground pipes, which is critically important in leak locating, is also described.

An Experimental Analysis of Ultrasonic Cavitation Effect on Ondol Pipeline Management (온돌 파이프라인 관리를 위한 초음파 캐비테이션 효과에 대한 실험적 분석)

  • Lee, Ung-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.67-75
    • /
    • 2024
  • In the context of Korean residential heating systems, Ondol pipelines are a prevalent choice. However, the maintenance of these pipelines becomes a complex task once they are embedded within concrete structures. As time progresses, the accumulation of sludge, corrosive oxides, and microorganisms on the inner surfaces of these pipelines diminishes their heating efficiency. In extreme scenarios, this accumulation can induce corrosion and scale formation, compromising the system's integrity. Consequently, this research introduces an ultrasonic generation system tailored for the upkeep of Ondol pipelines, with the objective of empirically assessing its practicality. This investigation delineates three variants of ultrasonic generating apparatuses: those employing surface vibration, external generation, and internal generation techniques. To emulate the presence of contaminants within the pipelines, substances in powder, slurry, and liquid forms were employed. The efficacy of the cleaning process post-ultrasonic wave application was scrutinized over time, with image analysis methodologies being utilized to evaluate the outcomes. The findings indicate that ultrasonic waves, whether generated externally or internally, exert a beneficial effect on the cleanliness of the pipelines. Given the inherent characteristics of Ondol pipelines, external generation proves impractical, thereby rendering internal generation a more viable solution for pipeline maintenance. It is anticipated that future endeavors will pave the way for innovative maintenance strategies for Ondol pipelines, particularly through the advancement of internal generation technologies for pipeline applications.

Analysis on Signal Properties due to Concurrent Leaks at Two Points in Water Supply Pipelines (상수도 배관에서 두 지점의 동시 누수에 따른 신호특징 분석)

  • Lee, Young-Sup
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Intelligent leak detection is an essential component of a underground water supply pipeline network such as a smart water grid system. In this network, numerous leak detection sensors are needed to cover all of the pipelines in a specific area installed at specific regular distances. It is also necessary to determine the existence of any leaks and estimate its location within a short time after it occurs. In this study, the leak signal properties and feasibility of leak location detection were investigated when concurrent leaks occurred at two points in a pipeline. The straight distance between the two leak sensors in the 100A sized cast-iron pipeline was 315.6 m, and their signals were measured with one leak and two concurrent leaks. Each leak location was described after analyzing the frequency properties and cross-correlation of the measured signals.

An Experimental Study on Detection of Gas Leakage Position by Monitoring Pressure Values at City Gas Pipeline (압력값 모니터링을 통한 배관 내 가스누출감지에 대한 실험적 연구)

  • Jin, Kyoung-Min;Choi, Gyu-Hong;Lee, Song-Kyu;Chung, Tae-Yong;Shin, Dong-Hoon;Hwang, Seung-Sik;Oh, Jeong-Seok
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.292-297
    • /
    • 2011
  • Gas pipeline safety management and risk prediction are recognized as a very important issue. And the effort to prevent accidents is essential. So, in this study, it was studied through correlation of pressure changes for leak point detection in real-time. It experimented by installing the five leakage valves in the pipe of 378 m and compared the actual leak points with simulation results. The results showed that experimental leak points and the actual leak points have differences within the 6 m. And this technology has to be commercialized by the demonstration in dangerous zone.