• Title/Summary/Keyword: 배경선 검출

Search Result 107, Processing Time 0.027 seconds

Acridine Orange Stained Micronucleus Assay in Human B and T-lymphocytes after Low Dose ${\gamma}-irradiation$ (아크리딘 오렌지 형광염색법을 이용한 저선량 감마선 유도 말초혈액 B와 T-림프구 미소핵 분석)

  • Choi, Jeong-Mi;Kim, Hee-Sun;Yang, Kwang-Hee;Kim, Cha-Soon;Lim, Yong-Khi;Kim, Chong-Soon;Woon, Jae-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.9-15
    • /
    • 2004
  • Firstly, we compared the two staining techniques, Giemsa and Acridine orange, to determine micronuclei on samples of cultures of five healthy human peripheral blood lymphocytes after ${\gamma}-irradiation\;(^{137}Cs)$ in dose ranges of 0 to 800cGy. It was found that the Acridine orange staining method gives more reliable results than the usual Giemsa staining method in micronucleus tests. Moreover, the frequency of micronuclei in cytokinesis-blocked human B-lymphocytes was studied after in vitro irradiation in dose ranges of 0 to 50cGy. After setting and separating the B-lymphocytes, the frequency of radiation-induced micronuclei were observed as the end-point markers for the low-dose radiation dosimetry after staining with Giemsa and Acridine orange dyes. The micronuclei frequency in B-lymphocytes was significantly elevated from 10 to 30cGy ${\gamma}-irradiation$. The determination of micronuclei in B-lymphocytes after staining with Acridine orange was higher than that of Giemsa. The frequency of micronuclei in B-lymphocytes was observed to be at least two times higher than those of T-lymphocytes Giemsa in dose increasing. Therefore, the determination of low-dose radiation-induced micronuclei in B-lymphocytes after staining with Acridine orange is likely to have the greatest potential in the estimation of low dose radiation exposure.

3D Film Image Classification Based on Optimized Range of Histogram (히스토그램의 최적폭에 기반한 3차원 필름 영상의 분류)

  • Lee, Jae-Eun;Kim, Young-Bong;Kim, Jong-Nam
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.71-78
    • /
    • 2021
  • In order to classify a target image in a cluster of images, the difference in brightness between the object and the background is mainly concerned, which is not easy to classify if the shape of the object is blurred and the sharpness is low. However, there are a few studies attempted to solve these problems, and there is still the problem of not properly distinguishing between wrong pattern and right pattern images when applied to actual data analysis. In this paper, we propose an algorithm that classifies 3D films into sharp and blurry using the width of the pixel values histogram. This algorithm determines the width of the right and wrong images based on the width of the pixel distributions. The larger the width histogram, the sharp the image, while the shorter the width histogram the blurry the image. Experiments show that the proposed algorithm reflects that the characteristics of these histograms allows classification of all wrong images and right images. To determine the reliability and validity of the proposed algorithm, we compare the results with the other obtained from preprocessed 3D films. We then trained the 3D films using few-shot learning algorithm for accurate classification. The experiments verify that the proposed algorithm can perform higher without complicated computations.

Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis (연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.42-62
    • /
    • 2008
  • Objectives: It is well known that some parameters of the photoplethysmogram (PPG) acquired by time domain contour analysis can be used as markers of vascular aging. But the previous studies that have been performed for frequency domain analysis of the PPG to date have provided only restrictive and fragmentary information. The aim of the present investigation was to determine whether the harmonics extracted from the PPG using a fast Fourier transformation could be used as an index of vascular aging. Methods: The PPG was measured in 600 recruited subjects for 30 second durations, To grasp the gross age-related change of the PPG waveform, we grouped subjects according to gender and age and averaged the PPG signal of one pulse cycle. To calculate the conventional indices of vascular aging, we selected the 5-6 cycles of pulse that the baseline was relatively stable and then acquired the coordinates of the inflection points. For the frequency domain analysis we performed a power spectral analysis on the PPG signals for 30 seconds using a fast Fourier transformation and dissociated the harmonic components from the PPG signals. Results: A final number of 390 subjects (174 males and 216 females) were included in the statistical analysis. The normalized power of the harmonics decreased with age and on a logarithmic scale reduction of the normalized power in the third (r=-0.492, P<0.0001), fourth (r=-0.621, P<0.0001) and fifth harmonic (r=-0.487, P<0.0001) was prominent. From a multiple linear regression analysis, Stiffness index, reflection index and corrected up-stroke time influenced the normalized power of the harmonics on a logarithmic scale. Conclusions: The normalized harmonic power decreased with age in healthy subjects and may be less error prone due to the essential attributes of frequency domain analysis. Therefore, we expect that the normalized harmonic power density can be useful as a vascular aging marker.

  • PDF

Rapid Extraction of DNA using Ion Exchange Resin for Early Detection of Mycobacterium tuberculosis by the Polymerase Chain Reaction (결핵균 PCR에서 이온교환수지를 이용한 신속한 DNA 분리)

  • Kim, Cheol-Min;Park, Seung-Kyu;Shon, Mal-Hyun;Song, Sun-Dae;Kim, Young;Jun, Eun-Sook;Son, Han-Chul;Jung, Byung-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.30-37
    • /
    • 1996
  • Background: The extraction methods of DNA from clinical samples are the major obstacle to use the PCR(polymerase Chain Reaction) in routine labortary for early detection of M. tuberculosis. We tried to improve the extraction method of DNA from sputum for establishment of the PCR in routine labortary by reducing the possibility of cross contamination and performing it easily and safely. Methods: We used the $InstaGene^{TM}$ DNA extraction kit(BioRad Co.) using Chelex 100 ion exchange resin for preparation of DNA. We compared InstaGene method in 100 cases of sputum from proteinase K method which is known as the most commonly used method for DNA purification(Experiment 1). And we compared InstaGene method in 98 cases of sputum from Microwave method developed by a company in Korea(Experiment 2). In experiment 1,245bps of IS6110 were amplified and then 188bps were amplified by nested PCR. In experiment 2,536bps in primary PCR and 276bps in nested PCR were amplified and analysed by agarose gel electrophoresis and EtBr staining. Results: When we chose AFB smear, culture, or AFB smear and culture as a standard test, PCR had low specificity and positive predictive value in both experiments. The InstaGene method has higher value in sensitivity and negative predictive value significantly than proteinase K method. The InstaGene method and the Microwave methods were similar in sensitivity, specificity, positive predictive value and negative predictive value. Conclusion: Even though both methods had lower possibility of cross contamination, shorter time requirement, simplicity, and economic advantages than Proteinase K method, the InstaGene method was a little simpler than the Microwave method. Therefore, in terms of usefulness in clinical application, the Instagene method seems to be the most useful method in DNA extraction for detection of M. tuberculosis using PCR. The reliability of this method will be clarified by further studies with enough clinical samples.

  • PDF

A Study on Measuring Vehicle Length Using Laser Rangefinder (레이저 거리계를 이용한 차량 전장 측정 방법에 관한 연구)

  • Ryu, In-Hwan;Kwon, Jang-Woo;Lee, Sang-Min
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.1
    • /
    • pp.66-76
    • /
    • 2016
  • Determination of type of a vehicle is being used in various areas such as collecting tolls, collecting statistical traffic data and traffic prognosis. Because most of the vehicle type classification systems depend on vehicle length indirectly or directly, highly reliable automatic vehicle length measurement system is crucial for them. This study makes use of a pencil beam laser rangemeter and devises a mechanical device which rotates the laser rangemeter. The implemented system measures the range between a point and the laser rangemeter then indicates it as a spherical coordinate. We obtain several silhouettes of cross section of the vehicle, the rate of change of the silhouettes, signs of the rates then squares the rates to apply cell averaging constant false alarm rate (CA-CFAR) technique to find out where the border is between the vehicle and the background. Using the border and trigonometry, we calculated the length of the vehicle and confirmed that the calculated vehicle length is about 94% of actual length.

Effect of Non-Agricultural Facilities on Water Quality and Contamination in Rural Area (농촌용수 수질관리를 위한 비농업시설의 영향 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Kim, Yang-Bin;Woo, Nam-Chil;Nam, Kyoung-Phile;Lee, Jong-Min
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • This study was objected to identify the effect on water quality and contamination by non-agricultural facilities in 'A' reservoir watershed located in OO city, Kyounggi-do, Korea. Ground- and stream water samples showed (Na+K)-Cl, Ca(Cl, SO$_4$) and Ca-Cl type in an illegally discharging area of sewage and a densely industrial area indicating water contamination. Stream water of an illegally discharging area of sewage had high COD, T-N and T-P. In this area, direct incoming of sewage into stream water was induced ground water system by well pumping, and it made a progress of ground water contaminations with those components. Groundwater of a densely industrial area showed high concentrations of T-N, NO$_3$N. From a nitrogen isotope analysis, stream water of an illegally discharging area of sewage has ${\delta}^{15}N-NO_3$values of 0.7%0 was strongly affected by nitrogen originated from agrochemicals, and a densely industrial area of 19.7%0 from septic system. Ground- and stream water of a livestock fanning area were contaminated with NH$_3$-N and Mn, which was affected by intensive livestock facilities. SAR-conductivity plot indicates the water does not pose either alkalinity or salinity hazard for irrigation. COD, T-N, T-P, NO$3$-N, NH$_3$N and Mn concentrations from contaminated areas were diminished by mixing with 'A' reservoir water. There were no water contaminations in silver towns, vacationlands around reservoir and golf links. Consequently, it should be made a plan of systematic managements for past and- present possible contaminants and sewage systems in preventing water contamination by non-agricultural facilities.

Serum cholinesterase activities and serum bromide concentrations in farmers (농업인에서의 체내 잔류농약 검출)

  • Choi, Soo-Jin;Hwang, Sang-Hyun;Chun, Sa-Il;Min, Won-Ki;Lee, Seon-Ho;Kim, Sung-Ryul;Kim, Young-Sik;SunWoo, Sung;Jun, Tae-Hee;Chung, Tae-Heum
    • Journal of agricultural medicine and community health
    • /
    • v.23 no.2
    • /
    • pp.305-310
    • /
    • 1998
  • The usage or agricultural chemicals is on the increasing tendency. Methyl bromide and organophosphate are the most widely used toxic agricultural chemicals in Korea. We try to set up the methods to detect the accumulation of these chemicals in Korean farmers. Blood samples were collected for 121 farmers of slack's season in February 1998. And survey about arable acreage and usage of the gloves and masks was also performed. Serum cholinesterase activities and bromide concentrations were measured with gold chloride method and colorimetric method. The reference ranges of serum cholinesterase activity and bromide concentration were 1.6~15.9 U/mL and below $72.9{\mu}g/mL$. Serum bromide concentrations of farmers and normal controls showed no differences. Serum cholinesterase activities of farmers were significantly higher than those of normal controls. According to the arable acreages and usage of the gloves and masks, serum bromide concentrations and cholinesterase activities showed no differences. In conclusion, serum cholinesterase activities and bromide concentrations showed no differences between farmers of slack's season and normal controls.

  • PDF