• Title/Summary/Keyword: 배가스 분석

Search Result 58, Processing Time 0.02 seconds

Study on Separation Characteristics of Flue Gas Using Hydroquinone Clathrate Compounds (하이드로퀴논 크러스레이트를 이용한 배가스 분리 특성 연구)

  • Lee, Jong-Won;Choi, Ki-Jong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.865-868
    • /
    • 2011
  • An organic substance, hydroquinone is used to form clathrate compounds in order to identify separation characteristics of carbon dioxide in flue gas. Formed samples were analyzed by means of the solid-state $^{13}C$ nuclear magnetic resonance (NMR) and Raman spectroscopic methods to examine enclthration behaviors of guest species. In addition, elemnetal analysis was also performed in order to evaluate separation efficiency of $CO_2$ in a quantitative way. Based on the experimental results obtained, $CO_2$ molecules are found to be captured into the clathrate compound more readily than $N_2$ molecules. Moreover, because such preferential enclathration is even more significant at low pressure conditions, $CO_2$ separation/recovery from flue gas can be achieved with minimizing additional energy cost for the technique. Experimental results obtained in this study can provide useful information on separation techniques of flue gas or selective separation of gas mixtures in the future.

Simulation of flue gas treatment section in RDF combustion process using Aspen Plus (Aspen Plus를 이용한 RDF 소각시 발생하는 배가스 처리 공정 모사)

  • Lee, Ju-Ho;Jung, Moon-Hun;Kwon, Young-Hyun;Kim, Min-Choul;Lee, Gang-Woo;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.848-850
    • /
    • 2009
  • 화석에너지 고갈로 인한 유가 상승으로 폐기물 에너지화가 이슈화 되고 있다. 폐기물 고형 연료 RDF는 에너지 문제를 해결하기위한 대안 중 하나로 수송성, 저장성, 연소안정성이 우수하나 환경오염 물질의 발생이 문제가 된다. 이러한 오염물질을 처리하기 위한 배가스 오염 물질처리를 위한 plant 설비 비용과 시간이 많이 투자된다. Aspen plus는 mass energy balance와 화학적평형, 열역학을 이용하여 공정 모사를 할 수 있는 프로그램으로 검증되었다. RDF의 삼성분, 원소분석, 발열량을 입력을 통해 HCl, SOx, NOx, CO의 배출량을 예측하고 이에 맞는 SNCR, SDA 등과 같은 반응기를 적용 하므로써 다양한 배가스 처리를 모사 할 수 있다. NOx를 제어하기위에 urea주입과 SOx와 HCl을 제거하기 위한 CaO를 주입을 모사 하므로써 실제 운영 적용 전 단계에 역할로 유용한 도구로 판단된다.

  • PDF

A Study on the Heat Exchanger Fouling Characteristics of Sludge Incinerator at the IronWorks (제철슬러지 소각로 열교환기에서의 파울링특성 연구)

  • 박상일;김정근;김기홍;박용준;조성문
    • Journal of Energy Engineering
    • /
    • v.12 no.3
    • /
    • pp.223-230
    • /
    • 2003
  • A study was performed to measure and analyze the gas-side fouling of heat exchanger to cool the exhaust gas from sludge incinerator at ironworks. The incinerator gas passes through inside of the vertical tubes of heat exchanger to preheat the combustion air. This kind of fouling occurs at the entrance region of the heat exchanger and thus the perforated fouling plate was designed to measure the gas-side fouling and to analyze the particulate deposit. As a result of analysis, the particulate deposition rate was influenced by temperature, particulate composition and size and also the deposition patterns were different according to the location of perforated fouling plate. The computational analysis was performed to obtain the deposition rates at the perforated fouling plate and the calculation showed that the deposition rate was varied with the hole size and particulate size. It was proved that the fouling at the entrance region of heat exchanger could be measured by the perforated fouling plate designed in this study.

Study on Wet Electric Precipitation with Electrospray for Removal of PM1.0 in Exhaust Gas (배가스 내 PM1.0 미세먼지 제거를 위한 정전분무 습식 전기집진기에 대한 연구)

  • Cho, Yeonjoo;Lim, Hyunjeong;Kim, Soyeon;Choi, Sangmi;Jeong, Min Kyu;Kim, Minsung
    • Plant Journal
    • /
    • v.16 no.1
    • /
    • pp.34-37
    • /
    • 2020
  • The need to improve the performance of the dust collector by increasing the fine dust pollution in Korea is eminent. In this study, electrostatic spray wet electrostatic precipitator is used to remove Particulate Matter (PM). In order to enter the Cone-jet mode, which is the most stable spray mode among the various modes of electrostatic spraying, an appropriate voltage-flow condition must be satisfied, and a voltage-flow interval enabling this can be expressed as Stability Island. The voltage at which the conduit mode starts in the Stability Island section is referred to as the electrostatic spray minimum voltage (Onset Voltage). However, the conventional electrostatic spray is uses a very low flowrate, at most few millilitres per minute. The use of much higher flowrates has introduced different patterns of electrospray modes. In this study, the different spray modes will be studied in detail.

The Operational Characteristics of CO2 5 ton/day Absorptive Separation Pilot Plant (이산화탄소 5 ton/day 흡수분리 Pilot Plant 운전 특성)

  • O, Min-Gyu;Park, So-Jin;Han, Keun-Hee;Lee, Jong-Seop;Min, Byoung-Moo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.128-134
    • /
    • 2012
  • The pilot scale experiments can handle the flue gas up to 1,000 $Nm^3/hr$ for separation of carbon dioxide included in real flue gas at coal-fired power plant. The operational characteristics was analyzed with the main experimental variables such as flue gas flow rate, absorbent circulation rate using chemical absorbents mono-ethanolamine( MEA) and 2-amino-2-methyl-1-propanol(AMP). The more flue gas flow rate decreased in 100 $m^3/hr$ in the MEA 20 wt% experiments, the more carbon dioxide removal efficiency was increased 6.7% on average. Carbon dioxide removal efficiency was increased approximately 2.8% according to raise of the 1,000 kg/hr absorbent circulation rate. It also was more than 90% at $110^{\circ}C$ of re-boiler temperature. Carbon dioxide removal efficiency of the MEA was higher than that of the AMP. In the MEA(20 wt%) experiment, carbon dioxide removal efficiency(85.5%) was 10% higher than result(75.5%) of ASPEN plus simulation.

A Study on the Property of Combustion tower Dust in EAF Process (전기로 연소탑 하단에 포집되는 분진의 특성 연구)

  • Kim, Young-Hwan;Yoo, Jung-Min
    • Resources Recycling
    • /
    • v.26 no.5
    • /
    • pp.48-53
    • /
    • 2017
  • During steelmaking on EAF, 1 ~ 2% of dust is generated. EAF Dust contains 20 ~ 30% of Zn and Fe. Dust contained in Off-gas is passed through combustion tower and cooling tower, and then captured in bag filter. About 15 wt.% of dust is dropped at the bottom of Combustion tower by its specific gravity, which was also carried out to recycle company with more higher charge than Bag filter dust. This study is focused on the combustion tower dust, and seperation as a function of operation period and particle size. As a result, Zn and Fe content of dust is more affected by size factor than operation period.

A Study on Heat Transfer Characteristics of Humidifier/HRU for MCFC (MCFC용 가습기 및 HRU의 열전달 특성 연구)

  • Park, Sungho;Kal, Hanjoo;Jeong, Youngsik;Lee, Sanghoon;Lee, Jaejun;Oh, Yongmin;Kim, Seonhwa
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.97.2-97.2
    • /
    • 2011
  • 본 연구는 연료전지 중 용융탄산염을 전해질로 하는 MCFC의 MBOP에 포함된 부품으로 매우 중요한 역할을 하는 가습기와 이때 발생되는 폐열을 회수하기 위한 장치인 HRU에 관한 것이다. 가습기는 연료와 물이 가습기 상부로 유입되어 가습기 하부로 유입되는 배가스와 열교환을 하면서 물이 스팀화 되어 연료가 가습된 상태로 가습기 출구로 일정온도를 유지하며 배출된다. 또한 HRU는 가습기에서 배출된 고온의 배가스를 물을 이용하여 열교환을 통해서 열을 회수하여 난방 및 온수로 사용할 수 있는 열교환 장치를 말한다. 먼저 이들의 특성을 파악하기 위해 가습기 및 HRU를 설계, 제작하여 각각의 특성을 확인하였다. 가습기와 HRU의 성능 향상을 위해 먼저 열교환부에 적용될 튜브의 수치해석적 분석을 통해서 최적의 열전달 성능을 얻을 수 있는 가습기 및 HRU를 설계, 제작하였으며 이들의 성능을 파악하기 위해 120,000kcal/h 용량을 테스트 할 수 있는 장치를 구축하여, 이들의 열전달 특성, 압력강하, 회수 열량, 가습기 온도 등의 특성을 파악하였다. 이 장치를 통해서 확인된 가습기와 HRU의 특성은 수치해석을 통해서 얻은 값과 거의 유사함을 확인할 수 있었으며, 가습 성능도 효과적으로 달성할 수 있었다. 가습기와 HRU의 특성 중 압력강하 부분은 지속적인 연구가 필요한 부분이며, 가습기와 HRU의 일체화를 통하여 소형화 및 설치공간 축소 효과를 얻을 것으로 본다.

  • PDF

Reviews on Gas Separation Membrane Process (분리막공정을 이용한 기체분리의 정상적 고찰)

  • 박영규;이영무
    • Membrane Journal
    • /
    • v.6 no.2
    • /
    • pp.59-71
    • /
    • 1996
  • 기체 막분리공정 기술이 점점 개발되어질수록 막분리의 성능을 이해하려는 필요성이 각 공정에서 증진될 것이며 기체 막분리 성능의 예측능 기술 발전을 위해 계속 시도되어질 것이다. 이러한 추세에 힘입어 현재 석유화학공정 배가스 중 수소를 정제하기 위한 기술 개발을 시도하고 있으며 특히 저농도의 수소를 고농도로 농축시키기 위해 막분리 공정을 적극 검토하고 있다. 본 논문에서 밝혀 본 막분리 공정의 성능 예측과 분석은 향후 공정을 설계하고 제작하는 데 크게 이바지할 뿐만 아니라 석유화학 제반 공정뿐만 아니라 관련 화학공업장치 산업에서 기체 분리를 통한 자원회수와 에너지 절약 측면에서 계속 발전해 나갈 것은 믿어 의심치 않을 것이다.

  • PDF

Source Estimation and Concentration Levels of PCBs in Ambient Air of an Industrial Area (공단지역 대기 중 PCBs의 오염농도 및 발생원 추정)

  • Kim, Kyoung-Soo;Song, Byung-Joo;Park, Seok-Un;Kim, Jong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.385-389
    • /
    • 2005
  • To understand the pollution level by polychlorinated biphenyls (PCBs) in ambient air of industrial area, PCBs concentrations were measured at Sihwa and Banwol industrial region, Korea. The concentrations of total PCB and WHO-TEQ ranged from 2,080 to $5820\;pg/m^3$ (median value is 2,760) and from 0.19 to $1.01\;pgTEQ/m^3$ (median value is 0.42), respectively. In terms of homologues composition the fraction of highly chlorinated biphenyls(from hexa-CB to deca-CB) were higher than the air samples of other regions such as jeonju and yokohama area. The cluster analysis was conducted to study the relation between the air samples and sources such as incinerator flue gases and Aroclor samples. The isomer fractions in the homologue were used as input variables. Based on the results, the industrial ambient air samples were divided from source samples with long Euclidian distance. This suggest that the ambient air samples of Sihwa and Banwol were not on the influence of Aroclor and incinerators. Therefore, further investigation on systematical air monitoring will be required to estimate the sources of PCBs in the above industrial areas.

A Study on the Characteristics of Waste Heat from the Industrial Complexes for Residential and Commercial Sectors (가정.상업부문 이용을 위한 산업체 폐열특성 연구)

  • 최영찬;박태준;홍재창;조선영
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.242-247
    • /
    • 1999
  • The characteristics of waste heat effluents from 11 industrial complexes of 7 areas were analyzed to investigate the possibility of waste heat recovery of huge amount of waste heat producing from various industrial complexes. This study presents a part of the research work for the industrial waste heat for development of energy integrated network system in broad city area, which will utilize industrial waste heat for residential and commercial areas, where they are located at some distances from the complexes. The amount of waste heat from the investigated complexes was detected as 148,913 TOE/year. However, It was analyzed 83% of the waste heat was analyzed the temperature range from 0$^{\circ}C$ to 200$^{\circ}C$. Also, it was evaluated that 82% of waste heat was exhausted by flue gases. Especially, the characteristics of waste heat for the areas where most heat concentrated, such as Tae-gu industrial complex, Ul-san petrochemitry complex, Yio-chun petrochemistry complex, and Chun-ju industrial complex were investigated more precisely. Total amount of waste heat discharged from these four areas were analyzed 114,402 TOE/year, which was occupied as 77% of the total waste heat for the studied areas, and 87% of the waste heat from the industries was exhausted by flue gaseous phase and temperature range was from 0$^{\circ}C$ to 200$^{\circ}C$ 18.1 million TOE/year waste heat was released from the fossil fuel power plants, however 95% of waste heat was analyzed as cooling water from surface condensers at power plants. The temperature range was measured from 27$^{\circ}C$ to 34$^{\circ}C$, which are unable to utilize due to its low temperature. Otherwise, 5% (894,800 TOE/year) waste heat released from power plants were observed as flue gas, which temperature ranged from 90$^{\circ}C$ to 170$^{\circ}C$.

  • PDF