• Title/Summary/Keyword: 방호물(防護物)

Search Result 191, Processing Time 0.023 seconds

Evaluation on Blast Resistance Performance of Reinforced Concrete Wall Strengthened by FRP Sheet (FRP 시트로 보강된 철근콘크리트 벽체의 방호성능 평가)

  • Lee, Kun-Ho;Kim, Jae-Min;Kim, Jae Hyun;Lee, Sang-Hoon;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.151-160
    • /
    • 2022
  • Owing to the recent increase in the frequency of explosion accidents, blast resistive design has garnered attention to reduce the damage of important structural elements. However, domestic research on the blast resistive structures is still insufficient, and domestic design guideline against blast loads are not documented yet. In this study, a numerical study on the RC blast resistive walls, where the test variable was the presence of FRP sheet, was performed using LS-DYNA program. Based on the numerical results, displacement-time hysteretic curve, pressure-impulse diagram, and fragility curve of the test specimens were derived. It was shown that the FRP sheet strengthening method is efficient to improve the blast resistive performance of the RC wall. Also, the strengthening effect of FRP sheet on the RC wall was stronger when the magnitude of the blast load was greater.

위험물저장소의 화재방호 비용효과 분석

  • Yun, Jong-Cheol
    • 방재와보험
    • /
    • s.106
    • /
    • pp.27-32
    • /
    • 2005
  • 이 글은 The Hazardous Installation Directorate의 최우수 조사관인 Alan Tyldestey와 Atkins에서 화재안전 컨설턴트로 근무하고 있는 Peter Rew와 Richard Houlding가 위험물저장소의 화재방호 비용효과분석에 관해 발표한 연구보고서를 번역한 것이다.

  • PDF

일반물자에 대한 독성작용제 액체 접촉 방호효과 연구

  • Kim, Byeong-Seop;Kim, Jeong-Su
    • Defense and Technology
    • /
    • no.2 s.288
    • /
    • pp.68-79
    • /
    • 2003
  • 화학전에서 군부대 및 민방위 등을 제외하고는 대다수 시민들이 화학방호대책을 준비하기에는 어려운 것이 사실이다. 준비된 방호수단이 없는 가운데에서 화학공격 또는 테러를 당할 경우, 최소한의 방호대책을 강구하기 위해서는 주변에서 쉽게 구할 수 있는 일반물자류 중 그 역할을 할 수 있는 대체가능물자류를 확보하는 것이 중요하다. 따라서 이번 연구는 이런 대체물자류의 선정 범위 및 그 재질의 화학방호성능을 알아보는 기초적인 연구를 실시하는데 목적이 있었으며, 대체가능물자를 선택하는데 있어 기초자료를 제공하고자 하였다.

  • PDF

Radioprotective Effects of Grifola umbellata Extracts on ${\gamma}$ - Irradiated Mice (저령(猪笭) 추출물이 감마선에 조사된 생쥐에 미치는 방사선 방호효과)

  • Yoo, Beong-Gyu;Park, Joon-Chul
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.77-80
    • /
    • 2000
  • 전신 ${\gamma}$-선 조사전 Grifola umbellata(Gu) 추출물의 단일 투여가 생쥐의 생존율, 체중, 기관 무게 및 혈액세포에 미치는 효과를 조사하였다 ${\gamma}$-선 조사 24시간 전에 Gu 추출물을 복강 투여하였을시, ${\gamma}$-선을 조사한 생쥐의 40-day 생존율을 65.5%에서 78.6%로 증가시켰다. Gu 추출물의 투여는 ${\gamma}$-선 조사에 의한 비장과 흉선의 무게 감소를 완전히 막아주었다(P<0.05, P<0.01) 또한 이와 유사하나 다소 적은 방사선 방호효과가 Gu 투여군의 고환에서도 관찰되었다(P<0.05). Gu 추출물의 투여는 ${\gamma}$-선 조사시 나타나는 조사 후 7일째까지의 백혈구와 림프구수의 현저한 감소를 지연시켰고, 회복속도를 촉진시켰다. 또한 21일째후의 적혈구수의 회복을 촉진시켰다. 이와 같은 결과에서 Gu 추출물의 방사선 방호효과를 알 수 있다.

  • PDF

Evaluation of Fracture Behaviours of Cementitious Composites by High-velocity Projectile Impact (고속 비상체 충격에 의한 시멘트 복합체의 파괴거동 평가)

  • Min, Ji-Young;Cho, Hyun-Woo;Lee, Jang-Hwa;Kim, Sung-Wook;Moon, Jae-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.55-62
    • /
    • 2015
  • An importance of infrastructures' protection against crash or blast loading has been an emerging issue as structures are becoming much bigger and population densities in downtown are growing up. However, there exists no such a standard to evaluate the protection performance of construction material itself. Prior to building standards for protection assessment techniques, this study performed gas-gun propelled projectile impact tests with series of contact-type monitoring systems to investigate the applicability of each sensing type. Through the impact tests, failure modes and protection performances of both normal concrete and UHPC (Ultra High Performance Concrete) reinforced by steel fibers were also evaluated. The results showed that LVDT could be applicable for the impact test among contact-type sensors and UHPC with fibers had a remarkable potential to improve protection against impact loading.

A Study on Impact Resistance Properties with Composition Materials and Installation Conditions of Protective Panel (방호 패널의 구성 재료 및 설치 조건에 따른 내충격 특성에 관한 연구)

  • Seok, Won-Kyun;Kim, Young-Sun;Lee, Yae-Chan;Nam, Jeong-Soo;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.6
    • /
    • pp.715-726
    • /
    • 2023
  • This study suggested that protective panels should be installed as sacrificial members as a safety design method for structures with potential explosions such as hydrogen charging stations to minimize direct damage to the structure and have resilience. To this end, the focus of the experiment is on quantitatively evaluating the impact of the structure when the protection panel is installed closely or spaced apart from the structure in a high-speed collision situation of the projectile. The experimental design used steel plates instead of concrete structural members mainly used in the past for excellent reproducibility, and the impact of structural members was compared and analyzed through deformation differences on the back of the steel plate. In addition, the impact of changes in the physical properties of the elastic body used as a separation material for the protective member and the difference in shock wave transmission time according to the protective member and the elastic body on the structural member was investigated.

Evaluation of the Protection Performance of SB4 Class Concrete Barrier with Anti-Glare Function (SB4 등급 방현기능 콘크리트 방호울타리의 방호성능 평가)

  • Joo, Bongchul;Hong, Kinam;Yun, Junghyun;Lee, Jaeha;Kim, Jungho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.93-102
    • /
    • 2021
  • This paper describes the process of developing a concrete median barrier of SB4 grade with anti-glare function. The development section has a height and width of 1,270mm and 560mm, respectively. A wire mesh is placed in the center of the cross section to improve the protection performance. Collision analysis predicted that this section satisfies the strength and occupant protection performance, and that no damage to the barrier occurs. In the actual collision test, it was confirmed that this section satisfies the strength and occupant protection performance. However, damage was observed on two concrete barrier when the truck crashed. In order to improve the accuracy of the collision analysis of the concrete barrier in the future, it is considered that a study on the model development and continuous collision analysis method for domestic commercial vehicles should be carried out.

Development of Impact·blast resistant hight performance fiber composite panel (방호·방폭용 고성능 복합섬유 패널 기술개발)

  • Kim, Woon-Hak;Kang, Seok-Won;Yun, Seung-Gyu
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.130-131
    • /
    • 2015
  • 이 논문은 패널의 각 단층 구성 재료에 고인장, 경량화, 부착성능, 내화성능 등을 향상시켜 단층 각각의 개별적인 특수 성능과 복합패널 구성물로서의 방호방폭 성능을 극대화 할 수 있는 섬유복합패널 외피와 충전재(나노복합소재) 및 접착제에 대한 기초 연구를 수행하였다.

  • PDF

STUDY ON SAFETY OF SPIRAL INSULATING & FLEXIBLE JUMPER PROTECTOR COVER (소용돌이형 점퍼선방호관의 안전성에 관한 연구)

  • Ji, Yong-Heon;Choi, Myeong-Ho;Lee, Jae-Young;Kim, Dong-Sik;Kwak, Sang-Young;Kim, Young-Chan;Kim, Nam-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.211-213
    • /
    • 2008
  • 배전선로는 항상 각종 공작물과 아주 가까운 상태에서 존재하고 있어 배전선로 근접 작업 시 전력선에 근접으로 인한 섬락 또는 접촉으로 작업원이 감전 재해를 입을 수 있으며 또는 비, 바람, 조류 등에 의한 이물 접촉으로 설비 고장을 유발 시킬 수 있다. 이러한 감전재해 및 설비고장을 예방하기 위하여 22.9kV-y 전력선의 직선부분에 사용할 수 있는 직선형 방호관을 개발하여 건설현장 주변의 전력선에 방호조치 함으로서 전력선 근접 작업 시 작업종사자의 안전 확보에 이바지함은 물론 정전사고방지에도 크게 기여하여 왔다. 그러나 22.9kV-y 배전선로의 점퍼선부분과 변압기의 인상선 등 곡선으로 되었거나 구불구불한 형상으로 된 부위는 직선형 방호관으로는 방호조치가 불가능하여 산업안전보건법이 정한 산업안전기준에 관한 규칙 제327조 제2호에 의한 방호조치를 취하지 않고 근접작업이 진행되어 감전재해와 정전사고가 발생되어 왔었다. 한전에서 협력업체와 공동으로 연구개발한 소용돌이형 점퍼선방호관을 그동안 방호조치를 취하지 못한 점퍼선이나 구불구불한 전력선부위에 방호조치를 함으로서 감전재해의 예방과 정전사고 발생을 획기적으로 감소시킬 것으로 기대된다.

  • PDF

Evaluation of impact resistance of high performance fiber reinforced cementitious composites under high-speed projectile crash (고속 비상체 충돌에 대한 고성능 섬유보강 시멘트 복합체의 방호성능 평가)

  • Moon, Jae-Heum;Park, Jung-Jun;Park, Gi-Joon;Cho, Hyun-Woo;Kim, Sung-Wook;Lee, Jang-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4950-4959
    • /
    • 2015
  • The importance of public infrastructures' protection against crash or blast loads has been emerging issue as structures are becoming bigger and population densities in downtown cities are growing up. However, there exists no sufficient study which considers the developments of protective building materials, that are essential for protective design and construction. To assess the protection performance and the applicability as protective materials of high performance fiber reinforced cementitious composites(HPFRCC), this study performed the impact tests with 40 mm gas-gun propelled projectile crash machine. From this study, it has observed that both high compressive strength of cement matrix and fiber reinforcement are beneficial for the improvement of impact resistance.