• Title/Summary/Keyword: 방폭성능

Search Result 48, Processing Time 0.027 seconds

Understanding of Blast Resistant Design and Performance Evaluation of a Building designed for Conventional Loads (방폭설계의 이해 및 일반하중에 대해 설계된 건축물의 방폭성능 평가)

  • Hong, Jong-Kook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.83-90
    • /
    • 2018
  • Considering the increased threats from worldwide terrors and the increased demands on the blast resistant design of commercial buildings, this study is aimed at understanding the basic concept of blast resistant design and evaluating the blast performance with an actual design example. Although there are many differences between earthquake and blast loads, the design concept against both loads is similar in terms of allowing the plastic behavior of a structure and sharing the ductile detailing. Through the blast performance evaluation of a target building provided in this study, it is noted that a well-designed building for the conventional loads can have a certain level of blast resistance. However, this cannot be generalized since the blast load on a structure varies depending on the type of weapon, TNT equivalence, standoff distance, etc. Architectural planning with positioning the sacrificial structure or maintaining a sufficient standoff distance from the expected detonation is the simple and effective way of improving the blast resistance of a building.

Performance Evaluation on Blast-resistant of Gastight Door using Numerical Simulation (수치해석을 활용한 가스차단문의 폭발압력저항 성능평가)

  • Shin, Baegeun;Kim, Jiyu;Kim, Euisoo
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.27-33
    • /
    • 2022
  • As the scale of explosions diversifies along with the expansion of gas handling and storage facilities, studies on explosion-proof facilities in preparation for accidents is being actively conducted. The gastight door blocks the expansion pressure caused by blast waves or internal fires, and at the same time protects the personnel and equipment inside. For gastight doors, the regulations related to explosion-proof design are not clearly presented, and studies on the explosion pressure resistance performance evaluation of the facility are insufficient. In this study, the gastight door was modeled in a 3D shape with reference to the regulation ASTM regarding the gastight door standard. Afterwards, evaluation for blast-resistant performance of gastight door using Numerical simulation was evaluated by using ANSYS Explicit Dynamics to compare the deformation.

Development of Impact·blast resistant hight performance fiber composite panel (방호·방폭용 고성능 복합섬유 패널 기술개발)

  • Kim, Woon-Hak;Kang, Seok-Won;Yun, Seung-Gyu
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.130-131
    • /
    • 2015
  • 이 논문은 패널의 각 단층 구성 재료에 고인장, 경량화, 부착성능, 내화성능 등을 향상시켜 단층 각각의 개별적인 특수 성능과 복합패널 구성물로서의 방호방폭 성능을 극대화 할 수 있는 섬유복합패널 외피와 충전재(나노복합소재) 및 접착제에 대한 기초 연구를 수행하였다.

  • PDF

전기기계.기구의 폭발방지

  • 이관형;최상원
    • 전기의세계
    • /
    • v.42 no.2
    • /
    • pp.48-59
    • /
    • 1993
  • 산업현장의 안전을 이룩하는데 화재 및 폭발 사고의 방지는 매우 중요하다. 또한 우리 제품의 수출활성화를 위해서도 국제적으로 표준화되고 인정받는 방폭전기기기의 규격 및 성능보장이 필수적인 요건으로 대두되고 있다. 이를 위해 정부차원에서도 본격적으로 법규를 개정하고 관련규격을 제정하는 등의 제도적 뒷받침을 시작하였으며, 그 일환으로서 폭발위험지역에서의 방폭형 전기기기의 사용을 의무화하고 이들 기기의 성능검정을 실시하게 되었다. 그러나 우리나라의 전기기기 방폭기술은 아직 초기단계에 있는 만큼 관련업체, 성능 검정기관 및 정부기관의 적극적인 설비투자와 학계 및 연구기관 등의 적극적이고 지속적인 연구개발을 통하여 이를 본격적인 궤도에 올려 놓아야 할 것이다. 최근 매스콤의 잦은 보도를 통하여 알 수 있듯이 재산에 막대한 손실을 가져오므로 철저한 사전 대비에 의하여 예방토록 하여야 할 것이다. 이를 위해 위험지역에서 사용하는 전기기기의 방폭화는 필수적이다.

  • PDF

Organic fiber reinforcement for Performance improvement of Blast resistance and Flexural Performance Evaluation of Fiber reinforced concrete using organic fiber reinforcement (방폭 성능 강화용 유기계 섬유보강재 제조 및 이를 혼입한 섬유보강 콘크리트의 휨성능 평가)

  • Jeon, Chanki;Jeon, Joongkyu;Kim, Sungil;Kim, Kihyung
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.211-218
    • /
    • 2015
  • This study propose the organic fiber reinforcement for performance improvement of blast resistance. Proposed fibers are polyamide fiber, PET fiber and aramid fiber and fiber reinforcements were produced by ATY method. To evaluate strain energy absorption capacity of organic fiber reinforced concrete using organic fiber reinforcement, 4-point bending test and 3-point bending tests on notched beam were performed. Test results show that PET fiber reinforced concrete has outstanding performance. It is thought that the PET fiber is effective for the performance improvement of blast resistance.

A Study on Material Properties of Composite Panel for Impact·Blast Resistance (방호·방폭 보강용 복합패널의 재료특성에 관한 연구)

  • Kim, Woonhak;Kang, Seokwon
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.4
    • /
    • pp.373-380
    • /
    • 2016
  • In order to develop composite fiber panels that can maximize the protection and blast resistance of the existing structures by improving lightweight, high-strength and fireproof performances of the single layer material of precast panels, the basic properties of the inner and outer covers that are mixed with aramid fibers (AF) and polyester fibers (PF) were evaluated in this study. Also, a basic study was performed on the performance of composite fiber panels by testing Nano-sized composite materials that are lightweight and excellent in fire resistance for their compressive strength, bending strength and tensile strength.

Effect of Seismic Design Details in Reinforced Concrete Beams on Blast-Resistance Performance (철근콘크리트 보의 내진 설계 상세가 폭발 저항 성능에 미치는 영향)

  • Kim, Kuk-Jae;Kim, Han-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.5
    • /
    • pp.427-434
    • /
    • 2017
  • Recently, awareness of the public about the explosion damage has increased due to the increased risk of terrorism. The criteria for blast-resistance design is not sufficient in Korea, it is necessary to develop blast-resistance design for the stability and safety of building by static analysis of current blast-resistance design. In addition, as the increase of earthquake occurrence necessitates the seismic design, it is studied to judge the blast-resistance performance of members applying seismic design without blast-resistance design. Currently, the general analysis of blast load is to refer to UFC 3-340-02 manual. Blast-resistance performance was studied by applying characteristics of blast load through UFC 3-340-02 manual, beam converted into equivalent SDOF System. It is proved that blast-resistance performance is improved when seismic detail is applied considering the maximum deflection of normal, intermediate, and special moment frames.

Flexural Performance Evaluation of HPFRCC with Aramid Fiber for Impact·Blast Resistance (내충격·방폭 성능 강화용 아라미드섬유 보강 HPFRCC의 휨성능 평가)

  • Jeon, Joong-Kyu;Kim, Sun-Gil;Jeon, Chan-Ki;Kim, Ki-Hyung
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.170-171
    • /
    • 2015
  • 본 논문에서는 내충격 방폭 성능 강화를 위해 개발된 유기계 단섬유 HPFRCC의 휨인성을 평가하였다. 유기계 단섬유 보강재는 아라미드섬유를 사용하였으며, 아라미드섬유 원사를 섬유가공 방법 중에 하나인 ATY(Air texturd yarn)공법을 통해 단섬유 형태로 제조하였다. 아라미드섬유 보강재를 혼입한 HPFRCC의 휨인성 시험을 통해 아라미드섬유의 내충격 방폭 성능 강화용 섬유보강재로의 성능을 평가하였다.

  • PDF

Basic Study on Fiber Composite Panel Production for Impact·Blast Resistant (방호·방폭 보강용 복합섬유 패널 제작을 위한 기초연구)

  • Kim, Woonhak;Kang, Seokwon;Yun, Seunggyu
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.235-243
    • /
    • 2015
  • The methods to improve the protection and explosion-proof performance of concrete structures include the backside reinforcement or concrete material property improvement and the addition of structural members or supports to increase the resistance performance, but they are inefficient in terms of economics and structural characteristics. This study is about the basic study on the fiber composite panel cover, and the nano-composite material and adhesive as the filler, to maximize the specific performance of each layer and the protection and explosion-proof performance as the composite panel component by improving the tensile strength, light weight, adhesion and fire-proof performances. The fiber composite panel cover (aramid-polyester ratios of 6:4 and 6.5:3.5) had a 2,348 MPa maximum tensile strength and a 1.8% maximum elongation. The filler that contained the nano-composite material and adhesive had a 4 MPa maximum tensile shear adhesive strength. In addition, the nano-composite filler was 30% lighter than the normal portland cement

Explosion Proof of Fiber Reinforced Cement Composite Panel subjected to Contact Explosion (접촉폭발에 의한 섬유보강 시멘트 복합체의 방폭성능)

  • Kim, Yun-Hwan;Kim, Gyu-Yong;Kim, Hong-Seop;Lee, Bo-Kyeong;Lee, Sang-Gyu;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.128-129
    • /
    • 2016
  • This paper evaluates experimentally the explosion proof of fiber reinforced cement composite(FRCC) panels with various fibers of 2 % volume fraction subjected to contact explosions using an emulsion explosive. As a results, the proportion of the total damage in FRCC panels is not biased scabbing on the rear side with contrast to plain panels, which means that the local damage of FRCC panels was significantly controlled. The experimental results presented useful information for prediction of limited thickness on the local damage subjected to contact explosions through comparison with existing damage evaluation prediction equations.

  • PDF