• Title/Summary/Keyword: 방출스펙트럼

Search Result 231, Processing Time 0.022 seconds

Acoustic Emission based early fault detection and diagnosis method for pipeline (음향방출 기반 배관 조기 결함 검출 및 진단 방법)

  • Kim, Jaeyoung;Jeong, Inkyu;Kim, Jongmyon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.3
    • /
    • pp.571-578
    • /
    • 2018
  • The deteriorated pipline often causes the unexpected leakage and crack. Negligence and late maintenance leads the enormous damage for gas and water resource. This paper proposes early fault detection and diagnosis algorithm for pipeline using acoustic emission (AE) signals. Early fault detection method for pipeline compares the frequency amplitude of the spectrum to that of the spectrum in normal condition. Larger amplitude of the spectrum indicates abnormal condition. Early fault diagnosis algorithm uses support vector machines (SVM), which is trained for normal and abnormal conditions to diagnose the measured AE signal from the target pipeline. In the experiment, a pipeline testbed is constructed similarly to real industrial pipeline. Normal, 5mm cracked, 10mm holed pipelines are installed and tested in this study. The proposed fault detection and diagnosis technique is validated as an efficient approach to detect early faulty condition of pipeline.

Laser-induced plasma emission spectra of halogens in the helium gas flow and pulsed jet (헬륨 가스 플로우와 가스 펄스 젯에서 할로겐족 원소들의 레이저유도 플라즈마 방출 스펙트럼)

  • Lee, Yonghoon;Choi, Daewoong;Gong, Yongdeuk;Nam, Sang-Ho;Nah, Changwoon
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.235-244
    • /
    • 2013
  • Detection of halogens using laser-induced breakdown spectroscopy (LIBS) in open air is very difficult since their strong atomic emission lines are located in VUV region. In NIR region, there are other emission lines of halogens through electronic transitions between excited states. However, these lines undergo Stark broadening severely. We report the observation of the emission lines of halogens in laser-induced plasma (LIP) spectra in NIR region using a helium gas flow. Particularly, the emission lines of iodine at 804.374 and 905.833 nm from LIPs have been observed for the first time. In the helium ambient gas, Stark broadening of the emission lines and background continuum emission could be suppressed significantly. Variations of the line intensity, plasma temperature, and electron density with the helium flow rate was investigated. Detection of chlorine and bromine in flame retardant of rubbers was demonstrated using this method. Finally, we suggest a pulsed helium gas jet as a practical and ecomonical helium gas source for the LIBS analysis of halogens in open air.

103P/Hartley 2 혜성의 고분산 스펙트럼을 이용한 미확인 분광선 연구

  • Son, Mi-Rim;Kim, Sang-Jun;Sim, Chae-Gyeong;Lee, Chung-Uk;Lee, Dong-Ju
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.42.2-42.2
    • /
    • 2011
  • 2010년 10월 28일 근일점을 통과한 103P/Hartley 2 혜성의 분광학적 특징을 연구하고자 11월 6일과 11일 양일간 보현산 천문대의 고분산 에셀 분광기 BOES(R~30,000)로 관측을 하였다. 우리는 Hartley 2 혜성의 고분산 분광자료를 Hwang et al.(2009)의 Machholz(C/2004Q2)혜성 가시광 영역($4800{\sim}8100{\AA}$) 고분산 분광 자료와 비교 분석하였고 그 결과 C2, CN, NH2,H2O+의 방출선 뿐만 아니라 다수의 미확인 분광선을 발견하였다. 또한 발견된 미확인 분광선을 설명하기 위하여 향상된 NH2방출선과 OH 방출선 등의 후보 물질을 이용하여 미확인선의 원인 물질을 제시하고자 한다. 이 발표에서는 지금까지의 분석 결과를 소개한다.

  • PDF

A Mechanism of the Bound Exciton Interaction with Longitudinal Optical Lattice Vibrations in Cathodoluminescence of Cadmium-Sulphide

  • Chung, Kie-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.9-13
    • /
    • 1974
  • The exciton emission spectra of CdS single crystals excited by electrons were measured at 80$^{\circ}$K as a function o: the wave length. The measured dissociation energy of exciton bound to neutral donor was 2.0 meV, compared to the corresponding theoretical value of 2.4 to 3.2 meV. An exciton bound to neutral donor and a longitudinal optical (LO) phonon may not interact, but a free exciton dissociated from a neutral donor and a LO phonon is expected to interact each other. Therefore the origin of the spectra consisting of interaction term was located at the spectrum consisting of a free exciton dissociated from a neutral donor (I$_2$d). From the analysis of the spectra the LO phonon energy of CdS was found to be 40.5 meV.

  • PDF

Electrodeposition of some Alpha-Emitting Nuclides and its Isotope Determination by Alpha Spectrometry (몇가지 알파입자 방출 핵종의 전해석출 및 알파 스펙트럼 측정에 의한 그의 동위원소 정량)

  • Key-Suck Jung;In-Suck Suh
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.279-286
    • /
    • 1983
  • An apparatus was made for the electrodeposition of alpha emitting actinide nuclides, $^{207}Bi$ and $^{210}Po$. The electrodeposition was made on a polished stainless steel plate cathode. The anode was made of platinum wire and to stir the solution. With the ammonium chloride as electrolyte initial pH = 4, chloride concentration = 0.6M and solution volume = 15ml, a current of 1.5 ampere(current density = 0.59A/$cm^2$) was flowed for 100 minutes for the quantitative recovery of electrodeposition and on average recovery of 98.3% was obtained within ${\pm}$0.7% uncertainty. Alpha spectrometry of the electrodeposited sample showed alpha peaks from $^{210}Po, ^{234}U$ and $^{239}Pu$ having energy resolution (FWHM) of 18.3, 21.8 and 36.0 keV respectively. The electrodeposition and alpha spectrometry for a natural uranium sample of domestic origin gave $^{238}U : ^{234}U = 1 : 6.1{\times}10^{-5}$ and for a neutron-irradiated uranium sample did $^{238}U : ^{239}Pu : ^{241}Am = 100 : 0.0263 : 5.20{times}10^{-5}$. The result of $^{238}U$ determination in the irradiated sample by electrodeposition-alpha spectrometry was in accord within ${\pm}1.6%$ of relative error with the results of solid fluorimetry and mass spectrometry. For $^{239}Pu$ the result of electrodeposition-alpha spectrometry was in accord within ${\pm}$4.0% of relative error with the results of anion exchange separation and the thenoyltrifluoroacetone(TTA) extraction both followed by alpha spectrometries.

  • PDF

Prompt Fission Neutron Spectra in Supercritical Accidents (Influence on the Fission Spectrum-averaged cross-sections of Some Threshold Activation Reactions)

  • Ro, Seung-Gy;Jun, Jae-Shik
    • Nuclear Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.119-126
    • /
    • 1975
  • On the assumption that the spectral distribution of prompt fission neutrons released from supercritical accidents can be expressed by the generalized Cranberg form with two spectral parameters, which is then transformed into the single parameter form, a variation of the fission spectrum-averaged cross-sections for some threshold reactions with varying the spectral parameter has teen calculated using an electronic computer. It appears that the average cross-sections are very sensitive to the spectral deformation, especially those for the detectors having the threshold at high neutron energy are high compared to those for the detectors of which the threshold energies are comparatively low.

  • PDF

Emission spectroscopic diagnostics of argon arc Plasma in Plasma focus device for advanced lithography light source (차세대 리소그래피 빛샘 발생을 위한 플라스마 집속장치의 아르곤 아크 플라스마의 방출 스펙트럼 진단)

  • Hong, Y.J.;Moon, M.W.;Lee, S.B.;Oh, P.Y.;Song, K.B.;Hong, B.H.;Seo, Y.H.;Yi, W.J.;Shin, H.M.;Choi, E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.581-586
    • /
    • 2006
  • We have generated the argon plasma in the diode chamber based on the established coaxial electrode type and investigated the emitted visible light for emission spectroscopy. We applied various voltages $2\sim3.5kV$ to the device by 0.5kV, and obtained the emission spectrum data for the focused plasma in the diode chamber on the argon pressure of 330 mTorr. The Ar I and Ar II emission line are observed. The electron temperature and ion density have been measured by the Boltzmann plot and Saha equation from assumption of local thermodynamic equilibrium (LTE) The Ar I and Ar II ion densities have been calculated to be $\sim10^{15}/cc\;and\;~10^{13}/cc$, respectively, from Saha equation.

A Study on Thermally Stimulated Luminescence and Exoelectron Emission Phenomena of MgO Single Crystals (MgO 단결정의 열자극 발광 및 Exo전자 방출 현상에 관한 연구)

  • Doo, Ha-Young;Sim, Sang-Hung;Kim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.165-172
    • /
    • 2006
  • On the MgO single crystals doped artificially with Cr, Cu, Fe we observed thermally stimulated luminescence(TSL) glow curves and spectra, and analyzed them in the temperatures range from at liquid nitrogen temperature(77K) to about 500K after excitation with UV or X-ray irradiation. TSL glow curves obtained from these samples show five peaks at 136.5K, 223.5K, 360K, 390K, 440K, and their estimated activation energies are 0.27eV, 0.63eV, 1.08eV, 1.08eV, 1.19eV, and 1.33eV, respectively. When we measured TSL spectrum at the range of 200nm to 650nm on the MgO single crystals. we also analyzed the peak wavelength which obtained at 345nm, 375nm, and 410nm from measurement of TSL spectrum and described their luminescence mechanisms. TSL spectrum peaks emitted from MgO:Cr, MgO:Cu, and MgO:Fe appear at the wavelengths of 345nm, 360nm, and 375nm, respectively.

  • PDF

Diagnosis of Insulation Deterioration in Cast-Resin Power Transformer using Acoustic Emission Techniques (음향방출법에 의한 몰드형 전력변압기의 절연열화 진단)

  • 이상우;김인식;이동인;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.35-42
    • /
    • 2000
  • In this paper, AE(Acoustic Emission) signals detected from the growth of the electrical tree in an epoxy resin under ac high-voltage application were analysed to diagnose the insulation deterioration of cast-resin power transformer. Frequency spectra of AE signals generated from the magnetizing and the load currents in the actual operating cast-resin power transformer of 500[kVA] under distribution system of 22.9[kV] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in the core of the transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals. The frequency spectra of AE signals generated from the cast-resin power transformer in operation due to both the magnetizing and the load currents appeared in the range of 40-120[kHz], but the frequency band of AE signals emitted from the void discharges in an epoxy resin sample was about 50[kHz] to 230[kHz].

  • PDF

In-Situ Application Study on the Power Plant Valve Leak Diagnosis Using Acoustic Emission Technology (음향방출을 이용한 발전용 밸브 누설 진단 현장 적용 연구)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.315-322
    • /
    • 2008
  • Valves in power plants are leaking internally by various damages including insertion of foreign objects on seat, seat crack, defects and fatigue crack of stem packing or welds etc. due to severe operating conditions such as high temperature and high pressure for extended period time. Acoustic emission(AE) technology should be applied in order to diagnose precisely and evaluate these valve internal leak. In this paper, results of studies which have accomplished in actual power plant are presented. We have analyzed background noise, AE signal level and frequency spectrum through laboratory tests on the basis of various actual conditions in power plant, and also have considered evaluation methods on the background noise, AE properties and the detectable minimum leak rate according to valve leak conditions through comparing with results of field tests in power plant. As a result of these studies, we conformed that evaluation of internal leak conditions including discrimination of leak or not, and the detectable minimum leak rate is possible, and also it is expected to contribute to safe operation and prevention of energy loss in power plants.