• Title/Summary/Keyword: 방청성능

Search Result 41, Processing Time 0.019 seconds

Performance and Optimum Formulation of Corrosion Inhibiting Admixture (방청 혼화제의 최적 Formulation 및 성능연구)

  • Chun, Yong-Jin
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.267-269
    • /
    • 2007
  • 콘크리트 중의 철근이 염분에 의해 부식되는 것을 억제 또는 예방하고, 각종 부식 환경으로부터 구조물의 수명을 연장할 목적으로 사용되는 방청혼화제의 최적 formulation과 그에 대한 물성 및 성능 시험을 실시하였다. 철근 부식에 대한 방청 메카니즘의 이해와 방청 혼화제의 formulation에 따른 물성시험과 성능평가를 실시하여 최적 조건을 확립하였다. 성능평가는 콘크리트 공시체의 Slump, 공기량, 압축강도(3일, 7일, 28일) 측정과 함께 염수침지시험 동의 방청성능 평가를 실시하였다.

  • PDF

Synthesis and Anti-corrosion Properties of Succinic Acid Alkyl Half-Ester Derivatives (숙신산 알킬 하프-에스테르 유도체의 합성 및 해수에 대한 방청성능)

  • Baek, Seung-Yeob;Kim, Young-Wun;Chung, Keun-Wo;Yoo, Seung-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.367-375
    • /
    • 2011
  • Succinic acid ester derivatives have been used as additives for the base oil of metal working fluids and pressure working oils. In this paper, a series of succinic acid alkyl half-esters were synthesized with over 97% yields by ring-opening reaction of succinic anhydride and fatty alcohol and were soluble in 100 N base oil within 1 wt% concentration. The structures and purities of ester derivatives were confirmed by $^1H-NMR$ and FT-IR spectrum and GC analysis. Anti-corrosion properties of the esters in sea water were evaluated through ASTM D665 method and weight loss method and compared to that of succinic alkyl esters without carboxylic acid group in the molecule. As the results, anti-corrosion properties of succinic acid alkyl half-esters with carboxylic acid group were better than those of succinic acid alkyl esters without carboxylic acid group. And, Anti-corrosion properties of the esters with a shorter alkyl chain of high concentration showed better performance than those with longer alkyl chain of low concentration. Inhibition efficiency % (IE%) of the esters was over 95% in the concentration of 80 ppm and corrosion rate (CR) was below 0.3 mm/year at the same concentration. Thus, the corrosion properties of succinic acid alkyl half-esters result from the carboxylic acid groups in molecules.

Synthesis and Anti-corrosion Properties of Succinic Acid Alkyl Half-amide Derivatives (숙신산 알킬 하프-아마이드 유도체의 합성 및 해수에 대한 방청성능)

  • Baek, Seung-Yeob;Kim, Young-Wun;Chung, Keun-Wo;Yoo, Seung-Hyun;Kim, Nam-Kyun
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.314-324
    • /
    • 2011
  • Several amide derivatives have been used as additives for base oil of metal working fluids and pressure working oils. In this paper, a series of succinic acid alkyl half-amide derivatives were synthesized as over 97% yields by ring-opening reaction of succinic anhydride and several amines and were soluble in 100 N base oil within 1 wt% concentration. The structures of the synthesized amides were confirmed by $^1H$-NMR, FT-IR spectrum and GC analysis. Anti-corrosion properties of the amides in sea water were evaluated through ASTM D665 method and weight loss method. As the results of anti-corrosion properties, the properties of the amides with shorter alkyl chain and high concentration showed better performance than those with longer alkyl chain and low concentration. Also, the dialkyl amides showed better anti-corrosion properties than those of the monoalkyl amides. Inhibition efficiency% (IE%) was over 93% in the concentration of 40 ppm and corrosion rate (CR) was below 0.5 mm/year in the same concentration.

An Experimental Study on Corrosion Resistance of Epoxy Coated Reinforcements (에폭시 도포철근의 내 부식성능에 관한 실험적 연구)

  • 오병환;엄주용;권지훈
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.4
    • /
    • pp.161-170
    • /
    • 1992
  • 근래 들어 철근 콘크리트에 있어서의 철근부식이 관심의 대상이 되고 있는데 그이유는 이 현상이 실제 구조물에서 광범위하게 발생함이 확인되었고 이로 인한 보수비용이 급증하였기 때문이다. 철근의 부식이 처음 거론된 것은 해양구조물과 내화학성 구조물에서였고 최근 들어서는 교량상판, 주차공간등 염기에 노출되어 철근 부식이 우려되는 각 종의 구조물에 광범위하게 그 대책이 연구되기에 이르렀다. 이와같은 철근부식이 제어방법으로는 첫째로 콘크리트의 수밀화를 들 수 있고 다음으로 콘크리트의 표면을 처리하거나 피복두께를 늘이는 방법이 있다. 마지막으로 철근자체에 방청성능을 직접 부여하여 방법에 속하는 에폭시 도포 철근의 기본적인 방청성능을 고찰하기 위해 수행되었다. 연구결과 에폭시 도포철근의 방청성능은 매우 우수함을 발견하였고 앞으로 활용이 기대되고 있다.

A Study on the Characteristic of Anti-corrosive Performance for the Cable Members (케이블 부재의 방청성능 특성에 관한 연구)

  • Ahn, Seung-Whan;Han, Sang-Eul;Lee, Sang-Ju
    • Proceeding of KASS Symposium
    • /
    • 2006.05a
    • /
    • pp.66-72
    • /
    • 2006
  • Recently nonlinear materials are used in construction of building and bridge then various structure formats are achieved positively. one of them, cable members, are the interesting study object which increase rigidity of a total structure by inducing tension. The way of construction using cable members is increasing, so the technology of design and construction are developing. Protection Fretting Fatigue is very important to maintain efficiency of cable member permanently. However, recognition of this is somewhat humble and this paper considers anti-corrosive performance of cable.

  • PDF

A Study on the Anti-corrosion Properties of Organic and Inorganic Inhibitor by Electrochemical Evaluation Method in Saturated Aqueous Solution of Calcium Hydroxide (포화 수산화칼슘 수용액 내에서의 무기계 및 유기계 방청제의 전기화학적 방식 특성평가)

  • Kim, Soo-Young;Ryu, Hwa-Sung;Kim, Sung-Kil;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.66-74
    • /
    • 2013
  • In this study, corrosion potential ($E_{corr}$), corrosion rate, and polarization resistance were measured aimed at inorganic inhibitors (passive film type) and organic inhibitors (absorption type). The experiment was conducted using potentiostat for the variable molar ratio and chloride ion concentration of the components of inhibitors in an aqueous solution of saturated calcium hydroxide targeting corrosion. As a result, it was possible to ensure an anticorrosive performance of at least a 1.2 molar ratio of inorganic inhibitors. Also, the organic inhibitors ensured the prevention of the anticorrosive performance of at least about a 0.3 molar ratio. It also showed the tendency that between polarization resistance and corrosion rate, Ecorr and corrosion rate is inversely proportional to the linear. Conversely, the tendency between polarization resistance and Ecorr is proportional to the linear. Also, a distinct difference in organic and inorganic inhibitors' relationship to Ecorr, corrosion rate, and polarization resistance was not shown.

AnExperimental Study on Corrosion Resistance of Epoxy Coated Reinforcements (에폭시 도포철근의 내 부식성능에 관한 실험적 연구)

  • 오병환;엄주용;권지훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.88-93
    • /
    • 1992
  • 근래 들어 철근 콘크리트에 있어서의 철근 부식이 관심의 대상이 되고 있는데 그 이유는 이 현상이 실제 구조물에서 광범위하게 발생함이 확인되었고 이로 이한 보수비용이 급증하였기 때문이다. 철근의 부식이 처음 거론된 것은 해양구조물과 내화학성 구조물에서였고 최근 들어서는 교량상판, 주차공간 등 염기에 노출되어 철근 부식이 우려되는 각 종의 구조물에 광범위하레 그 대책이 연구되기에 이르렀다. 이와 같은 철근부식의 제어방법으로는 첫째로 콘크리트의 수밀화를 들 수 있고 다음으로 콘크리트의 표면을 처리하거나 피복두께를 늘리는 방법이 있다. 마지막으로 철근 자체에 방청성능을 직접 부여하여 철근의 부식을 방지하고자 하는 방법을 들 수 있다. 본 연구는 이러한 대책중에서 가장 적극적인 방법에 속하는 에폭시 도포 철근의 기본적인 방청성능을 고찰하기 위해 수행되었다.

  • PDF

Synthesis and Performance of Dialkylamine (di-)nitrobenzoates for Vapor Corrosion Inhibitor (기화성방청제 Dialkylamine (di-)nitrobenzoates 합성 및 방청성능)

  • Chun, Yong-Jin;Park, Yong-Sung;Soh, Soon-Young
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.6-11
    • /
    • 1999
  • Dialkylamine (di-)nitrobenzoates as vapor corrosion inhibitor were synthesized with dialkylamines and (di-)nitrobenzoic acids. The compounds were analyzed by elemental analyzer, FT-IR and $^1H$-NMR spectrophotometer. Corrosion inhibition of synthetic compounds and additives [$(NH_4)_2CO_3$, $NaHCO_3$] against ferrous and non-ferrous metal was investigated by potentiostatic method [1% (w/v) corrosion inhibitor in 1M $Na_2SO_4$ aqueous solution] respectively. For corrosion inhibition of ferrous metal, dialkylamine 4-nitrobenzoates were better inhibitor than dialkylamine 3, 5-dinitrobenzoates, the passivating current density ($i_p$) of dialkylamine 4-nitrobenzoate was shown $4.78mA/cm^2$. While, for non-ferrous metal, dialkylamine 3, 5-dinitrobenzoates were better, those of dipropylamine 3, 5-dinitrobenzoate and hexamethyleneimine 3, 5-dinitrobenzoate were shown 36 and $37mA/cm^2$. Additive effect of $(NH_4)_2CO_3$ and $NaHCO_3$ for corrosion inhibition of ferrous metal was excellent but that of non-ferrous metal was not. Optimum ratios of diethylamine 4-nitrobenzoate with $(NH_4)_2CO_3$ and $NaHCO_3$ were 4 : 6 and 5 : 5 (V/V), and passivating current densities ($i_p$) of the mixtures were shown 0.26 and $0.85mA/cm^2$, respectively.

  • PDF

Experimental Study on the Penetration Depth and Concentration of Corrosion Inhibitor Using Press-in Method Into the Inside of Concrete (콘크리트 내부로의 압입공법을 사용한 방청제의 침투깊이 및 농도에 관한 실험적 연구)

  • Cho, Hyeong-Kyu;Yoo, Jo-Hyeong;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.160-168
    • /
    • 2009
  • After steel bar was corroded it removes concrete contaminated, it does steel bar corrosion protection, repairing method and corrosion inhibitor spreading method are difficult to secure corrosion protection performance. Accordingly, in this research before Research and Development to penetrate corrosion inhibitor to high pressure by steel bar position, it measures penetration depth through corrosion inhibitor high pressure penetration experiment and amount of nitrite by position and then it predicts penetration depth in accordance with water-cement ratio, pressure, pressure time and it computed water-cement ratio, pressure, pressure time to be more than 0.6 mol ratio of chloride ion and nitrite to have outstanding corrosion protection performance. As a result of experiment, water-cement ratio gives the biggest influence to penetration of corrosion inhibitor and also the more depth of specimen becomes deep, concentration of penetrated corrosion inhibitor does not equal and becomes low.

The Experimental Study on Performance of Cementitious and Organic Anti-corrossion Coatings (시멘트계 및 유기계 도포재료의 방청성능에 관한 실험적 연구)

  • 신도철;이종열;박정순;오희갑;이태규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.150-154
    • /
    • 1995
  • The purpose of this study is to evalute the mechanical and the anti-corrosion characteristics of cementitious, organic coatings on steel plates. Tests are performed according to KS M 5331, 5250, etc'. For the test, we used water based epoxy, Tar epoxy, the red lead, and cementitious anti-corrosion coatings. The results of adhension tests satisfying the requirements in relevant standards The impact test shown that the impact test shown that the impact resistance of cementitious anti-corrosion test, rred lead, epoxy, cementitiouse show good corrosion resistance.

  • PDF