• Title/Summary/Keyword: 방진재

Search Result 49, Processing Time 0.029 seconds

Vibration Characteristics of a Compound Mounting System on an Elastic Floor (탄성바닥에 지지된 합성방진계의 진동특성)

  • 김찬묵;윤수언
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.151-156
    • /
    • 1993
  • 본 논문에서는 탄성바닥 위에서의 세개의 질량과 두개의 방지재로 구성된 지지계에 의한 진동절연의 이론적 고찰과 실험에 의한 검증을 하였다. 효과 적인 진동절연은 본 논문에서 기본적으로 관심을 가지는 탄성바닥에서의 진 동전달률을 감소시키는 것이며, 단순한 수학적 형태로 표현되는 진동전달률 공식은 영향계수법(Receptance Method)을 이용하여 유도된다.

  • PDF

Developing Microcellular Foamed Vibration Isolator for DVD by Axiomatic Approach (공리적 접근을 이용한 DVD용 초미세 발포 방진재 개발)

  • Jeong, Pil-Jung;Cha, Seong-Un
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.12
    • /
    • pp.101-106
    • /
    • 2000
  • As the rotational speed of optical disk drive is increasing nowadays, the reliability to vibration and shock becomes more important. For this, various of rubber vibration isolators are being developed by varying the shape and hardness. But it is difficult for the hardness of common used rubber to be lowered below Duro 30 degrees, and because of the shape complexity of rubber vibration isolator there are difficulties of analysis. Microcellular foamed vibration isolator has various cell densities and cell sizes, so it can vary the stiffness and damping coefficient. In addition, its hardness can be lowered below Duro 30 degrees. Axiomatic Approach is very useful design method for designing new product or new process. Axiomatic Approach's character is scientific and analytical method. In this paper, developing process of microcellular foamed vibration isolator for DVD is presented with Axiomatic Approach.

  • PDF

The Study on Vibration Isolation of Industrial Turbo-fan (산업용 터보팬의 진동절연에 관한 연구)

  • Park, Ik-Pil;Kim, Dong-Young;Kwon, Yong-Soo;Ahn, Chan-Woo
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.609-615
    • /
    • 2001
  • A turbo-fan is easily exposed to noise and vibration as against other industrial machines and the majority of them is subject to be damaged by vibration. The most usual problem of vibration in a turbo-fan is resonance so the case of being composed of iron sheet structure with low strength like a turbo-fan should be taken seriously. In this paper, FFT(Fast Fourier Transform) and Order tracking method were used to analyze factors of vibration in a turbo-fan and hereby with proper selection of vibration isolator, we wanted to reduce vibration of base. After Order tracking, we knew resonance occurred in rotational frequency 23 Hz(1400 rpm) at the casing and the bearing. After the test of base vibration using vibration isolators, the spring isolator was more effective than the robber isolator in the base vibration and the vibration isolating is more effective in the case that the isolating pad is adhered to the bottom of the isolating spring.

  • PDF

A study of noise source identification on plate excited structure borne sound by acoustic intensity method (음향인텐시티법에 의한 고체진동 가진판의 소음원 검출에 관한 연구)

  • 오재응;김상헌;홍동표;이찬홍
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.43-55
    • /
    • 1986
  • In the studies of noise reduction, it is important to know the generation mechanism of noise in order to identify the noise source. The relation between the structural vibration and the radiated sound is very complex and so this paper deals with a simplified radiation model that was originally developed as a verification tool for the acoustic intensity measurement procedure. As the first step for the identification of the noise source, this study deals with the noise evaluation by measuring sound pressure. On the next step, the acoustic radiational pattern is determined by the acoustic intensity method and this paper established that the acoustic intensity method is effective on the detection of noise. In the study, furthermore, the method could be used to predict the change in the sound radiational characteristics with the attachment of absorber and could be used in determining the attachment position.

  • PDF

Introduction and Preliminary Design of Floating Slab Track for Rapid Transit Railway (고속철도용 플로팅 슬래브 궤도의 도입과 기본설계)

  • Kim, Yong-Jae;Lee, Eun-Ho;Park, Myoung-Gyun;Moon, Je-U;Park, Man-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.141-144
    • /
    • 2008
  • Recently, railway has been pointed to the efficiency of transportation, rapid transit, and comfortable train ride. the construction of railway near the downtown area and station building are increasing for maximization of utilization and convenience. but the heavy of transportation and rapid transit lead to increase noise and vibration. the noise and vibration of railway may cause the civil appeal, decline in the serviceability and insufficiency of environmental standard. Therefore, the solution to avoid environmental matters becomes one of the most important factor in constructing railway. In this study, floating slab system which is one of the solution to avoid noise and vibration in railway has been introduced, and the concept of preliminary design and vibration absorber of floating slab system according to the isolator has been introduced.

  • PDF

A Vibration Problem and Countermeasures for the Deck House and Stern of a Ro/Ro Ship (차량운반선의 거주구와 선미의 연성진동문제 및 방진대책)

  • Man-Cheol Han;Sang-Heon Oh;Il-Cook Baik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.135-144
    • /
    • 1994
  • The coupled vibration of the deck house and stern structure, which was experienced on a 12,900 TDW Ro/Ro ship, has been studied. It was a large-scale vibration problem where the structure resonates with the propeller excitation at the first blade passing frequency. After discussing the structural characteristics of the ship, the vibration characteristics measured ducting the sea-trial are presented and compared with the analysis results which are based on a 3 dimensional finite element(FE) model. The FE model is also used to verify various reinforcement options and to predict their effectiveness. A substantial reduction or the vibration was confirmed during the sea-trial after installing a few selected reinforcement. The forced vibration response, which is computed using the FE model, is compared with the measured data. The change of the vibration characteristics according to loading conditions is also studied.

  • PDF

Study on the vibration control acaused by unbalance force for a W-type air compressor (W형 공기압축기의 불평형진동 저감에 관한 연구)

  • Kim, Yeong-Ju
    • 연구논문집
    • /
    • s.28
    • /
    • pp.145-159
    • /
    • 1998
  • 선박이나 산업플랜트에 이용되고 있는 압축공기의 압력이 증가되고 압축기의 경량화 내지는 설치면적을 축소하기 위하여 3단압축을 하므로서 토출압력을 30기압 이상으로 증가할 수가 있다. 그러나 크랭크기구를 갖고있는 공기압축기의 실린더 배열이 복잡하고 고속운전으로 인하여 크랭크축에 연결된 왕복질량과 회전질량에 의한 불평형력이 저감되도록 왕복질량의 적절한 배치와 중량감소를 위해 주철재 피스톤 재질을 알미늄합금으로 교체하고 적절한 평형추 설치와 방진고무의 선택을 검토해야한다. 본 연구에서는 3개의 실린더가 60도 간격으로 배치되는 W형 공기압축기의 진동상태를 측정하고 이를 분석하여 진동저감을 위한 대책으로 평형추 계산이론을 도출하는데 중점을 두었다. 검토대상 공기압축기의 사양은 표1에 보이는 바와 같다.

  • PDF

A Study on the Mechanical Behavior of Resilient Sleeper in Concrete Bed by Connection (콘크리트 도상 방진 침목의 연결재 유·무에 대한 역학적 거동 고찰)

  • Kim, Sung-Chil;Lee, Ki-Sung;Kim, Jun-Hung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.1
    • /
    • pp.121-128
    • /
    • 1998
  • The rail, which supports the train road, distributes the wheel loads to the tie by rail stiffness. Subway sleeper on concrete ballast is construction of PC or RC sleeper. The present, PC sleeper is constructed of line 1, 2, 3, 4 Seoul Subway and RC sleeper is planing construction for the STEDEF system on concrete ballast of the line 5, Seoul, Taegu, and Kwangju Subway. The major purpose of this study is to check influence of the angle with analysising the behavior of sleeper according to the existent or non-existent of angle. And the study is carried to check static analysis by manufacture of same model.

  • PDF

Functional Finishing of Nonwoven Filter for Dust-proof/Medical Masks by Corona Discharging Treatment (코로나 방전에 의한 방진/의료용 마스크 여과재의 기능화 가공)

  • Hong, Young-Ki
    • Textile Coloration and Finishing
    • /
    • v.25 no.3
    • /
    • pp.232-239
    • /
    • 2013
  • In this study, 25gsm melt-blown polypropylene nonwoven for dust-proof/medical masks was finished by the corona discharging treatment. The influence of corona discharging parameters on the filtration efficiency was investigated. Several parameters such as discharging voltage, discharging speed, distance to discharging wire and configuration of discharging system had an effect on filtration efficiency, while the parameters had no effect on breathing resistance. Optimum corona discharging conditions are as follows: Wires were installed on the upper part of the nonwoven and paper pipe was installed on the lower part of the nonwoven having a distance of 5cm. The sequence of wire voltages was +60 kV, +60 kV, 0, -60 kV, and -60 kV. The discharging voltage and speed were 60 kV and 30m/min respectively. The nonwoven treated by corona discharging at the optimum condition showed a filtration efficiency of 80% or more, which is suitable for dust-proof/medical masks.

Cyclic Responses of Steel Reinforced ECC Column under Reversed Cyclic Loading Conditions (철근 보강된 ECC 기둥의 반복하중에 대한 이력거동)

  • Hyun, Jung-Hwan;Shim, Young-Heung;Bang, Jin-Wook;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.75-82
    • /
    • 2015
  • In this study, experimental research was carried out to evaluate steel reinforced ECC (Engineered Cementitious Composites) column, which exhibits excellent crack control property and highly ductile behavior. Ordinary portland cement and high volume fly ash were used as binding materials in the mixture proportions for the purpose of achieving a high level of multiple cracking property with the tightly controlled crack width. To compare with the cyclic behavior of steel reinforced ECC column specimen, a conventional reinforced concrete column was prepared and tested under reversed cyclic loading condition. Based on the cyclic load test, ECC column exhibited higher cyclic behavior, compared to the conventional RC column, in terms of load carrying capacity and energy dissipation capacity.