• Title/Summary/Keyword: 방어앞치마

Search Result 4, Processing Time 0.019 seconds

Convergence Performance Evaluation of Radiation Protection for Apron using the PSNR (최대 신호 대 잡음비를 이용한 방사선 방어용 앞치마의 융복합 성능평가)

  • Kim, Dae-Ho;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.10
    • /
    • pp.377-383
    • /
    • 2015
  • This study evaluates the convergence radiation protection performance by measuring the PSNR(peak signal-to-noise ratio) values of the image J in the image evaluation program based on increased relative to this exposure of radiation workers.The aim of this study was to evaluate radiation protection performance of apron for design of it's basic information. Method was used to PSNR of Image J program and good condition apron was more than 27dB, the PSNR value of poor condition apron appeared to be less than 24dB. The result is the normality were satisfied distribution and T-test values were statistically significant with p<0.001. Results of evaluation of the performance protective apron through the more easily accessible experimental conditions and methods in the clinical was confirmed distinctly different. in order to reduce the radiation exposure we need to evaluate convergence protection performance and to be having a good performance apron.

Performance Evaluation of Radiation Protection Apron's (방사선방어 앞치마 성능 평가)

  • Kang, Jong-gu;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.373-377
    • /
    • 2019
  • Radiation exposure is on the rise as the working hours of radiation workers increase. Accordingly, the importance of protection products for decreasing the dose of exposure has risen, and excellent X-ray shielding ability and light weight are required. The purpose of this study is to compare the Pb which use currently and other elements in order to reduce the exposure of workers to the most effective protection products. For experiment, we used the general X-ray equipment and angiography equipment, and obtained the Pb and apron's shielding rate. When the shielding rate of Pb and apron was compared in general X-ray equipment, the shielding rate was 95.1% for Pb 0.5 mm, 96.1% for apron 0.5 mmPb and 95.6% for Bi+W 0.5 mmPb. When compared the shielding rate of each aprons in angiography equipment, 0.5 mmPb apron was the highest as 96.4% and Bi+W 0.25 mmPb apron was the lowest as 90.2% at the 50 cm distance. The shielding rate of 0.5 mmPb apron was the highest as 95.7% and Bi+W 0.25 mmPb apron was the lowest as 85.9% at the 100 cm distance. As a result of evaluating the apron efficiency through this study, 0.5 mmPb apron showed the best shielding rate, but it was the heaviest apron. 0.35 mmPb apron and Bi+W 0.25 mmPb apron weighed light but had low shielding rate. Through the results of this experiment, it is recommended that radiation workers reduce radiation exposure by using more efficient protection products.

Performance Evaluation of Aprons according to Lead Equivalent and Form Types (방사선 방어용 앞치마의 납당량, 형태에 따른 성능 평가)

  • Kim, Ki-Won;Choi, Sung-Hyun;Kim, Ki-Yeol;Lee, Ik-Pyo;Hwang, Sun-Gwang;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.219-225
    • /
    • 2016
  • The apron is one of the essential protectors to reduce the exposure dose of radiological technologists. This study is to provide a guideline for purchasing the aprons with excellent performance and to help reducing the exposure dose by measuring the shielding ration and uniformity of aprons according to lead equivalent and form types. The shielding ratio of aprons were measured by using radiation generator and dosimeter. Exposure conditions were 81 kVp, 25 mAs, source to image receptor distance (SID) 100 cm and field of view (FOV) $17^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$. Exposure areas for front type and around type aprons were divided into 9 areas and for 2 pieces type aprons were divided into 3 areas of top and 4 areas of skirt. The uniformity of aprons were measured by using fluoroscopy and Image J. The 4 regions of interest (ROI) were set into acquired images and measured uniformity by measuring the standard deviation of pixel intensity in ROIs. In continuous shielding ration measurement of aprons according to exposure area, there was not statistical significance (P>0.05). In ANOVA test of aprons, there was statistical significance (P<0.01). In the results of sheilding ratio, although the aprons had equal lead equivalent, there were difference in shielding ratio from 83.59% to 98.15%. In the results of uniformity, the front type aprons with equal lead equivalent indicated the similar uniformity. However, the around type and 2 pieces type apron with equal lead equivalent indicated the different uniformity each other, from 1.8 to 22.2. If the performance evaluation in this study were conducted regularly before and after purchase the aprons, the exposure does to patients and radiological technologists could be reduced.

Survey for Diagnostic Radiography Examination in Veterinary Hospital (동물병원 영상의학적검사 실태조사)

  • Lee, Won-Jeong;Jo, Sung-Mi
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.177-184
    • /
    • 2022
  • The purpose of this study is surveyed diagnostic radiography (DR) examination in veterinary hospital (VC) including non-ionization radiation such as ultra-sonography and magnetic resonance imaging. From June 1 to June 20. 2021, we surveyed the VC in 00 metropolitan city by using a structural questionnaire which are location of VC and X-ray unit et al.. Data are expressed as a mean with standard deviation for continuous variable or percent for categorical variable using SPSS ver. 26.0. As the first animal to be visited, dogs were the highest with 61.9%, followed by cats with 12.9%. In 87.1% fo cases, DR units were used, and 4 VCs did not. In 27 VCs using DR units, 48.1% separated examination room and control room, 19.8% examined in animal visited, protective clothing was in all VCs, 55.6% were measured radiation exposure dose, 92.6% was responded a necessary for examination education. From the above results, it will help to revise the guidelines for DR units and examination in korea VCs.