• Title/Summary/Keyword: 방수 시스템

Search Result 107, Processing Time 0.029 seconds

Tensile Adhesive Chracteristics of Waterproofing System for Concrete Bridge Decks (교량 바닥판 조건에 따른 교면방수 시스템의 인장접착 특성)

  • Lee, Byung-Duck;Shim, Jae-Won;Park, Sung-Ki;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.4 no.3 s.13
    • /
    • pp.15-23
    • /
    • 2002
  • The waterproofing system's performance is known to show a determing by complex interaction of material factors, design details, and the quality of construction, and the waterproofing integrity of waterproofing membranes is determined by the bond to the deck and the amount of damage to the waterproofing membrane. In this research, the basic properties of waterproofing membranes on market and the tensile adhesive chracteristics of waterproofing systems of concrete bridge deck have also been investigated in the view of the damages frequently reported from job site. For the tensile adhesive strength of sheet waterproofing membranes, the results after asphalt concrete paving tends to increase more than before those. The results of the liquid waterproofing membranes are upside-down, and the more concrete has strength, the more strength of tensile adhesive increase. The ambient temperature of asphalt concrete when application of the waterproofing membrane has considerable influence on the performance of waterproofing system. As described above, waterproofing system can be influenced by several factors. If they are not considered under construction, the overlooking will cause the damages of pavement and waterproofing system after traffic opening.

  • PDF

A Study on the Remote Controlled Fire Monitor for Plant-Only Smart Fire Monitoring (플랜트 전용 스마트 화재 모니터링 연동 방수총에 관한 연구)

  • Choi, Doo-Chan;Yang, Min-Hyeok
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.79-80
    • /
    • 2023
  • 본 논문에서는 화재 시뮬레이션을 이용하여 풍량, 풍향, 보관물질, 시설물의 위치 등 여러 요소를 고려한 플랜트 시설물의 상황별 화재 성상을 분석하여 화재진압 시나리오를 구축하고 이를 스마트 화재 모니터링 구현을 위한 아키텍처 시스템을 설계하여 화재 초기상황에 스마트 화재 모니터링을 통해 방수총을 빠르게 동작시킬 수 있다. 플랜트 시설 화재 시 스마트 화재 모니터링과 연동된 방수총의 동작 시간을 효과적으로 단축시키며 화재 취약지점에 거점타격방식으로 방수하고자 한다

  • PDF

Design of Remote & Wireless Control System for Submarine using RF (RF를 이용한 잠수함 무선 원격시스템 제어 설계)

  • Kim, Young-Keun;Ryu, Kwang-Ryol;Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.192-195
    • /
    • 2007
  • 본 논문에서는 RF 모듈을 탐재한 Atmega 시스템 설계를 통한 잠수함 원격 제어 시스템을 구현한다. 본 연구에서 제작한 RC 잠수함은 실제 잠수함의 원리와 비슷하게 잠항을 할 때는 소형펌프로 밸러스트탱크에 물을 채우고, 잠수를 할 때 수직타와 추진력을 이용하여 잠항을 한다. 이와 반대로 부상은 소형펌프로 밸러스트탱크 안에 물을 배수하여 WTC(방수실린더)안의 기압과 수직타와 추진력을 이용하여 부상을 한다. RC 잠수함은 크게 외부와 내부 그리고 방수를 하기 위한 WTC(방수 실린더)로 나누어진다. 송신 부는 RF 모듈, MCU(Atmega128), 키패드, 캐릭터LCD로 구성되며 수신부는 MCU(Atmega128), RF 모듈, 제어장치들로 구성한다. 제어장치에는 모형 잠수함은 추진력을 위하여 DC 모터에 스크류(프로펠러)를 장착하고, 방향전환 및 잠항과 부상을 위하여 RC 서보 모터를 사용하고 잠항과 부상을 위하여 펌프를 사용한다. WTC는 방수실린더로서 아크릴파이프를 이용하여 제작하고 방수를 위하여 아크릴파이프를 이용 여기에 MCU와 제어 장치들을 넣어 밀봉시켜 방수를 하여 완성한다.

  • PDF

Estimation of Development Capacity Applicable to Current Power Generation System at the Discharge Channel of Hadong Thermal Power Plant (하동화력 방수로 조류식발전 개발규모 산정 및 수리특성 분석)

  • Kim, Ji-Young;kang, Keum-Seok;Lee, Dae-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.121-124
    • /
    • 2006
  • 국내외에 아직 적용 실적이 없는 발전소의 해수방류수를 이용한 조류식발전시스템의 개발을 위하여 하동화력발전소 방수로에 시험용 조류식 발전시스템을 설계 및 제작하여 현장시험이 진행 중이며, 이를 확장하여 상업용 발전을 위한 총 개발 규모를 산정하고 경제성을 분석하였다. 조류식발전구조물의 형상 설계, 가이드 베인을 이용한 출력 조정을 통하여 방수로의 수류상태를 적절히 조절하여 설계하는 것이 가능할 것으로 판단되며, 조류식발전구조물 설치시 방수로의 수류특성 수치계산 결과로 판단할 때 발전출력에 의한 에너지 회수뿐만 아니라 조류식발전구조물의 단면축소 효과 및 수두손실이 방수로의 수위 변화에 상당한 규모로 영향을 주고 있음을 확인하였다. 조류식발전구조물 설치 이전의 유속 관측 결과를 이용하여 발전량을 산정한 경우 소수력발전 단가 적응시 경제성이 떨어지지만, 조류식발전시스템의 설치시 유속 증가 효과가 나타날 뿐만 아니라 가이드 베인 등을 이용하여 발전량 증대를 꾀하면 충분한 경제성을 확보할 수 있는 조류식발전시스템의 설치가 가능할 것으로 판단된다.

  • PDF

Assessment of Evaluation by Hybrid Waterproof-Roof Barrier Layer for Green System on Artificial Ground (인공지반 녹화시스템 활용을 위한 일체형 방수·방근 시트의 성능평가)

  • Oh, Chang-Won;Hong, Jong-Chul;Park, Ki-Bong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.4
    • /
    • pp.391-396
    • /
    • 2015
  • The demands about eco friendly space are increased as buildings are denser in downtown, and green system on the roof and the artificial ground are widely being applied. The construction of green system applies a waterproof layer, a root barrier and a protection concrete layer. Assembly of these many layers leads to a long construction term, and cause many defects. This study is to evaluate one layer-hybrid sheet which gets waterproof and root barrier performance simultaneously, which is developed to use in the new green system. As results, the performances of physical properties, durability, waterproof and root barrier not only exceeded quality standards but also showed excellent durability. In addition, mock-up test would be proceed to certify long term performance.

Capacity Estimation and System Design of Current Power Generation at the Discharge Channel of Hadong Thermal Power Plant (하동화력발전소 방수로 조류식 발전량 산정 및 시스템 설계)

  • Kang, Keum-Seok;Kim, Ji-Young;Lee, Dae-Soo;Lee, Kwang-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.509-512
    • /
    • 2006
  • 국내 대형 기력발전단지에서 냉각수로 사용되고 방류되는 해수는 약 150cms로 (100Mwe 당 약 5cms) 약 3,000kW 이상의 수력에너지를 보유하고 있으나, 현재 활용되지 못하고 그대로 해양으로 방류되고 있다. 발전소 방수로는 흐름조건이 비교적 균일하고, 파랑 내습이 없으며 부유사 해조류, 부유물 충돌 등의 문제가 발생하지 않아 자연 해양조건보다 조류력 발전에 매우 유리하나 수심이 낮고, 순환수 계통에의 영향으로 다수의 수차를 설치하기는 어려운 조건을 지니고 있다. 따라서, 인공수로의 균일하고 양호한 흐름조건에 적합한 보다 경제적인 수차를 개발하고, 발전량을 증대하기 위한 수차 배치 기술, 수차 및 발전기 지지구조물의 설계 기술, 계통 연결기술 등을 개발할 필요가 있으며, 이를 위하여 시험용 조류식 발전시스템을 제작하여 수차의 성능 및 전체 발전시스템의 성능을 평가하여 발생되는 문제점을 해결하고자 한다. 본 연구에서는 시험용 조류식 발전시스템을 하동화력발전소 방수로에 적용하기 위하여 현장 특성 분석, 형식 선정, 발전량 산정 등의 시스템 설계를 수행하였다.

  • PDF

Water Jet Experiment of Automatic Fire-tracking Water Cannon Facility combined with Indoor Hydrant Facility in Road Tunnels (도로터널의 옥내소화전설비 겸용 자동화점추적 방수총설비의 방수실험)

  • Kim, Chang-Yong;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.92-98
    • /
    • 2019
  • To determine if water-jet nozzle moves and water jetting are effective according to the location of the fire, this study examined the automatic fire-tracking water cannon system and aan indoor hydrant system, such as water jet centered directivity, water jet range maintainability and water jet shape uniformity. First, an examination to find the center of fire accurately from this system design showed that the water jet centered test was accurate. Second, the water jet range test results showed that when water is jetted at the maximum water jet radius, the water jet shows an inaccurate result but within the allowable tolerance range. Finally, the water-jet shape test result confirmed that there are no problems in setting the block from the algorithm design.

Tension Strength and Expansion Property Analysis Research to Utillize Thermoplasticity Recycling Plastic to Single Play Waterproof System for Construction (열가소성 재활용수지를 건축용 단층방수시스템에 활용하기 위한 인장 및 신장 특성 분석 연구)

  • Park, Sung-Woo;Ko, Jin-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.89-94
    • /
    • 2011
  • In this research, among thermoplasticity plastic raw material that recycling is possible polyolefine(TPO) and polyvinyl chloride(PVC) as target recycling plan examine wish to. It is polyolefine(TPO) and polyvinyl chloride(PVC)) is mediocrity material that there are a lot of amount useds among plastic material and it is material that recycling is also activated most. Long term made first new regulation raw material, by-product raw material happened at process of production at second factory and third time to examine recycling plan of this material divides this as raw material that pass through process separation and pelet Tuesday and analyzed each special quality removing each removed waste after is used. Measure tension strength and ext. heightening gradually mixing proportion of refreshing resources on standard Sample manufactured as new raw material and application examined possibility availability to single fly system.

  • PDF

Effect of Asphalt Pavement Conditions on Tensile Adhesive Strength of Waterproofing System on Concrete Bridge Deck (아스팔트 포장 조건이 교면방수 시스템의 인장접착강도에 미치는 영향)

  • Lee, Byung-Duck;Park, Sung-Ki;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.5 no.2 s.16
    • /
    • pp.15-24
    • /
    • 2003
  • The performance of waterproofing system (WPS) is known to be a function of many complex interaction of material factors, design details, and the quality of construction, but it is mainly determined by the bond strength, which is measured by tensile adhesive strength (TAS) test. to the concrete bridge deck. In this research, eight waterproofing membranes were selected from commercial market and the tensile adhesive characteristics of the WPS on concrete bridge deck were investigated in view of various factor in asphalt pavement. The factors include type of asphalt mixture, pavement thickness, paving temperature and influence of wheel loading. TAS test of different asphalt pavement types showed that TAS of WPS under SMA (Stone Mastic Asphalt) pavement was greater than that under dense asphalt pavement. TAS of sheet membranes was improved as the compaction temperature of asphalt concrete increase, but TAS of liquid membranes were not. The influence of thickness of pavement val minimal with given laboratory test condition. TAS of sheet membranes after wheel tracking test were in the order of the sites under wheel path (UWP), before wheel tracking (BWT) and nearby wheel path (NWP). Since TAS of the same WPS of UWP was higher than TAS of BWT, wheel loading had function of pressing WPS resulting in higher adhesive strength. But liquid membranes were variable on types. The feature of detached interface after TAS test showed that sheet types were all detached in between deck concrete and WPS, and liquid types were detached in between asphalt pavement and WPS.

  • PDF

Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System (인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구)

  • Park, Chang-Hwa;Oh, Sang-Keun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.189-199
    • /
    • 2011
  • Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.