• Title/Summary/Keyword: 방사평형

Search Result 115, Processing Time 0.02 seconds

Radionuclides Transport from the Hypothetical Disposal Facility in the KURT Field Condition on the Time Domain (KURT 부지 환경에 위치한 가상의 처분 시설에서 누출되는 방사성 핵종의 이동을 Time Domain에서 해석하는 방법에 관한 연구)

  • Hwang, Youngtaek;Ko, Nak-Youl;Choi, Jong Won;Jo, Seong-Seock
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.4
    • /
    • pp.295-303
    • /
    • 2012
  • Based on the data observed and analyzed on a groundwater flow system in the KURT (KAERI Underground Research Tunnel) site, the transport of radionuclides, which were assumed to be released at the supposed position, was calculated on the time-domain. A groundwater pathway from the release position to the surface was identified by simulating the groundwater flow model with the hydrogeological characteristics measured from the field tests in the KURT site. The elapsed time when the radionuclides moved through the pathway is evaluated using TDRW (Time Domain Random Walk) method for simulating the transport on the time-domain. Some retention mechanisms, such as radioactive decay, equilibrium sorption, and matrix diffusion, as well as the advection-dispersion were selected as the factors to influence on the elapsed time. From the simulation results, the effects of the sorption and matrix diffusion, determined by the properties of the radionuclides and underground media, on the transport of the radionuclides were analyzed and a decay chain of the radionuclides was also examined. The radionuclide ratio of the mass discharge into the surface environment to the mass released from the supposed repository did not exceed $10^{-3}$, and it decreased when the matrix diffusion were considered. The method used in this study could be used in preparing the data on radionuclide transport for a safety assessment of a geological disposal facility because the method could evaluate the travel time of the radionuclides considering the transport retention mechanism.

Analysis of 226Ra in the Groundwater Using the Gamma-ray Spectroscopy (감마선 분광법을 이용한 지하수 중의 226Ra 분석)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.39-47
    • /
    • 2003
  • The measurement of radium ($^{226}Ra$) in the groundwater was established using ${\gamma}$-ray spectroscopy without sample preparation. The background interference by air borne radon daughter nuclides was reduced by $N_2$ gas flow into the counting chamber. Leakage of radon gas produced in the radioactive equilibrium with radium and its daughter nuclides was prevented by use of the air-tighted aluminium container. We investigated the effect of air layer in the counting container. Radioactivity variation due to emanation of radon into the air layer was within the counting error range 5%. When the nitrogen gas was flowed around the detector, peak counts of ${\gamma}$-rays from the daughters of airborne radon was decreased and detection limit was decreased to 0.02 Bq/L. The detection limit of detector was lower than 0.74 Bq/L, the $^{226}Ra$ Maximum Contaminant Level (MCL) in the groundwater proposed by US Environmental Protection Agency (EPA). It was confirmed that $^{226}Ra$ radioactivity in the groundwater could be determined by the ${\gamma}$-ray spectroscopy.

Quantities and Units in Radiation Dosimetry (방사선량(放射線量) 및 단위(單位))

  • Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.2 no.1
    • /
    • pp.38-46
    • /
    • 1977
  • 오늘날 에너지 공급(供給)을 위한 새로운 해결책(解決策)의 하나로서 등장(登場)한 원자력발전소(原子力發電所), 재래(在來)의 X선(線) 진료(診療) 이외(以外)에 의학계(醫學界)에 도입(導入)된 방사선원(放射線源), 그리고 각종(各種) 전자생산품(電子生産品) 등(等)의 증가현상(增加現象)은 방사선(放射線) 방어(防禦) 문제(問題)와 관련(關聯)하여 보건의학분야(保健醫學分野)에서 종사(從事)하는 사람들에게 지대(至大)한 관심(關心)거리가 되고있다. 그래서, 우선(于先) 방사선(放射線)에 관(關)한 사항(事項)중에서 가장 기초(基礎)가되는 방사선량계측(放射線量計測)에 있어서 그 양(量)과 단위(單位) 문제(問題)가 체계적(體系的)으로 서술(敍述)되었다. 즉(卽) 방사선(放射線)이 인체(人體)에 끼칠 수 있는 해(害)로운 영향(影響)에 그 주안점(主眼點)을 두어 조사선량(照射線量), 흡수선량(吸收線量), 선량당량(線量當量), 그리고 그들의 관계(關係) 및 방사능등(放射能等)에 관(關)하여 토론(討論)되었다. 특(特)히 조사선량률(放射線量率), X는 비(比)감마선선상수(線常數), ($\Gamma$)를 포함(包含)하는 함수(函數)로 표현(表現)되었고, 끝으로 인체(人體) 내부(內部)에 축적(蓄積)된 방사능(放射能)으로부터의 영향(影響)에 의(依)한 이른바 생물학적효과(生物學的效果) (Somatic or Genetic Effects)와 관련(關聯)되는 내부흡수선량율(內部吸收線量率)은 평형흡수선량상수(平衡吸收線量常數)($\Delta_i$)와 흡수율($F_i$)를 포함(包含)하는 수학적(數學的) 모델로 소개(紹介)되었다. 한편 방사능(放射能)은 방사선원(放射線源) 물질(物質)의 자연붕괴율(自然崩壞率)이므로 다른 방사선량(放射線量)들 즉(卽) 조사선량(照射線量), 흡수선량(吸收線量)그리고 선량당량(線量當量)과는 별도(別途)로 취급(取扱)하였음을 부언(附言)한다.

  • PDF

A Study of the Rn-222 and Ra-226 Analysis in Aqueous Samples with a Low-Level Liquid Scintillation Counter and Pulse-Shape Analysis (저준위 액체섬광계수기와 파형분석법을 이용한 수용액 중 라돈-222 및 라듐-226의 분석법 연구)

  • Shin, Hyun-Sang;Lee, Chang-Woo;Lee, Myung-Ho;Cho, Yung-Hyun;Hong, Kwang-Hee;Choi, Geun-Sik
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.428-435
    • /
    • 1999
  • A method for measuring Rn-222 and Ra-226 in aqueous sample using liquid scintillation counting technique has been studied. The Rn-222 was extracted easily from the water sample (10 mL) by 12 mL of xylene based organic scintillant. After radioactive equilibrium between Rn-222 and its alpha emitting decay products for three hours, the alpha activity from Rn-222 and its decay products were measured in a scintillation vial using the Wallae $1220^{TM}$ Quantulus liquid scintillation counter. Ra-226 concentration in aqueous sample was determined, after isolation of Ra-226 from the sample matrix, by extraction the ingrowth of the Rn-222 and its alpha emitting decay products with xylene based organic scintillant. The optimum pulse-shape analysis (PSA) value was evaluated by the figure of merit (FM) criterion. Minimum detectable activity (MDA) is about 0.14 Bq/L (3.78 pCi) for the region of Rn-222 and its alpha emitting decay products and 0.06 Bq/L (1.63 pCi) for the region of Po-214 respectively, with 200 min, counting time at PSA level 100 in the low-diffusion polyethylene vial and xylene based cocktail solution. Experiment on the optimum sample-cocktail volume ratio, the influence of agitation and the diffusion of radon from vial were carried out.

  • PDF

A Study on the Separation of Long-lived Radionuclides and Rare Earth Elements by a Reductive Extraction Process (환원추출에 의한 장수명핵종과 희토류 원소의 분리 연구)

  • 권상운;안병길;김응호;유재형
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.421-425
    • /
    • 2003
  • The reductive extraction process is an important step to refine the TRU product from the electrorefining process for the preparation of transmutation reactor fuel. In this study, it was studied on the reductive extraction between the eutectic salt and Bi metal phases. The solutes were zirconium and the rare earth elements, where zirconium was used as a surrogate for the transuranic(TRU) elements. All the experiments were performed in a glove box filled with a argon gas. Li-Bi alloy was used as a reducing agent to reduce the high chemical activity of Li. The reductive extraction characteristics were examined using ICP, XRD and EPMA analysis. The reduction reaction was equilibrated within 3 hours after the Li addition. Three eutectic salt systems were compared and Zr was successfully separated from the rare earth elements in all the three salt systems.

  • PDF

Distortion Correction of Surface Temperature Measurement Using an Infrared Camera (적외선 카메라를 이용한 표면온도측정의 왜곡 보정)

  • Lee, Sungmin;Kim, Ikhyun;Lee, Jong Kook;Byun, Yunghwan;Park, Gisu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.7
    • /
    • pp.545-551
    • /
    • 2016
  • Surface temperature of supersonic wind tunnel model was measured using an infrared thermography technique. To measure the temperature quantitatively, various calibration techniques such as blackbody calibration which converts detected camera signal to temperature, distortion correction due to the camera lens and an imbalance of camera pose, and emissivity calibration which considers viewing angles to the model surface, were employed. Throughout the study, for the quantitative as well as qualitative surface temperature measurement, it was verified that the distortion correction must be considered even for the use of two-dimensional model in aerodynamics testing.

The Study on Design of lead monoxide based radiation detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 산화납 기반 방사선 검출기 설계에 관한 연구)

  • Ahn, Ki-Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.183-188
    • /
    • 2017
  • In recent years, the automatic remote control controller of the gamma ray irradiator malfunctions, and radiation workers are continuously exposed to radiation exposure accidents. In the non-destructive testing field, much time and resources are invested in establishing a radioactive source monitoring system in order to prevent potential incidents of radiation. In this study, the gamma-ray response properties of the lead monoxide-based radiation detector were estimated through monte carlo simulation as a previous study for the development of a radioactive source location monitoring system that can be applied universally to various non-destructive testing equipment. As a result of the study, the optimized thickness of the radiation detector varies according to the gamma-ray energy emitted from the radioactive source, and the optimized thickness gradually increases with increasing energy. In conclusion, the optimized thickness of the lead monoxide-based radiation detector was $200{\mu}m$ for the Ir-192, $150{\mu}m$ for the Se-75 and $300{\mu}m$ for the Co-60. Based on these results, the appropriate thickness of lead monoxide-based radiation detector considering secondary-electron equilibrium was evaluated to be $300{\mu}m$ for general application. These results can be used as a basic data for determining the appropriate thickness required in the radiation detector when developing a radiation source location monitoring system for universal application to various non-destructive testing equipment in the future.

Study on the Measurement of Radon concentrations in soil samples using γ-spectrometer (γ-spectrometer를 이용한 토양시료의 라돈농도 측정법에 관한 연구)

  • Kang, Sunga;Lee, Sangsoo;Choi, Guirack;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.31-36
    • /
    • 2013
  • The radioactive gas radon ($^{222}Rn$), which is generated from the decay process of uranium ($^{238}U$) originating from the soil of more than 85 percent higher the porosity of the soil, the soil can radiate out the possibility that many isotopes. In order to protect the human body from radon, above all, the development of accurate measurement techniques to formulate appropriate measures should be followed. This study Gamma-ray spectrometry using a high purity germanium (HPGe) detector, if you want to measure radon unstable the nature radiation of the background problems can be reduced, radium and radon daughter nuclides after radioactive equilibrium leads to Radon concentration was measured, the soil samples from the Gamma-ray emitting nuclides, and the energy spectrum is analyzed.

An Analysis of the Sound Propagation between Rooms with Different Mediums (서로 다른 매질을 갖는 격실사이의 음파전달해석)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Lee, Seong-Hyun;Seo, Yun-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.402-407
    • /
    • 2013
  • In this paper, an analysis of sound propagation between two rooms with different mediums is discussed. Statistical energy analysis (SEA) is used to consider energy equilibrium among subsystems associated with the sound pressure levels in two rooms and the vibration level of the wall between rooms. Effect of the sound radiation from the structure-borne noise of the wall on sound pressure level of the receiving room is investigated. For a numerical example, sound propagation between engine room and water tank joined by a steel plate whose size is $8.4{\times}4$ m, is considered. It is found that when the critical frequency of the plate is above the frequency range of interest, the sound pressure level in the water tank is dominated by sound transmission through the plate, while sound radiation from the structure-borne noise of the plate is negligible except low frequency range below 63 Hz.

The Measurement of Airborne Radon Daughter Concentrations in the Atmosphere (대기중(大氣中) 라돈 붕괴생성물(崩壞生成物)의 공기중(空氣中) 방사능(放射能) 농도(濃度)의 측정(測定))

  • Ha, Chung-Woo;Lee, Jai-Ki;Moon, Philip S.;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.5-13
    • /
    • 1979
  • A simple method for determining the airborne concentration of radon daughter products has been developed, which is based on gross alpha counting of the air filter collections at several time intervals after completion of air sampling. The concentration of each nuclide is then obtained from an equation involving the alpha disintegrations, the sampling time, and the known numerical coefficients. The state of radioactive disequilibrium is also investigated. The atmosphere sampled in the TRIGA Mark-III reactor room was largely in disequilibrium. The extent of radioactive disequilibrium between radon daughter products seems likely depend on sampling times associated with turbulence conditions. The data obtained here will certainly provide useful information on the evaluation of internal exposure and calibration of effluent monitoring instruments.

  • PDF