• Title/Summary/Keyword: 방사선 피부관리

Search Result 16, Processing Time 0.021 seconds

Entrance Surface Dose according to Dose Calculation : Head and Wrist (피폭선량 산출을 통한 피부입사선량 계산: 머리 및 손목을 중심으로)

  • Sung, Ho-Jin;Han, Jae-Bok;Song, Jong-Nam;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.305-312
    • /
    • 2016
  • This study were compared with the direct measurement and indirect dose methods through various dose calculation in head and wrist. And, the modified equation was proposed considering equipment type, setting conditions, tube voltage, inherent filter, added filter and its accompanied back scatter factor. As a result, it decreased the error of the direct measurement than the existing dose calculation. Accordingly, diagnostic radiography patient dose comparison would become easier and radiogrphic exposure control and evaluation will become more efficient. The study findings are expected to be useful in patients' effective dose rate evaluation and dose reduction.

A Survey of Patient Satisfaction with the use of Aloe Vera Mist for Skin Care during Radiation Therapy for Breast Cancer (유방암 방사선치료 중 피부 관리를 위한 알로에 베라 미스트 사용에 대한 환자 만족도 조사)

  • Han-A Yun;Hyo-Young Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.231-242
    • /
    • 2023
  • This study aims to provide basic data to reduce the incidence of radiation dermatitis and improve patient satisfaction by investigating the management status and satisfaction level of radiation dermatitis in patients undergoing radiation therapy. From October 28, 2022, to April 4, 2023, a survey was conducted on 137 breast cancer patients who received radiation therapy at G Hospital in Busan. The Radiation Therapy Oncology Group (RTOG) cutaneous acute radiotherapy toxicity score was used as the standard for measuring skin reactions, and the association between cancer stage and RTOG was analyzed. SPSS program (ver. 18.0) was used for statistical analysis. The frequency of radiation dermatitis occurrence was relatively low, with 73% in the RTOG 0-1 group and 27% in the 2-3 group. Patient satisfaction after radiation therapy varied significantly depending on the RTOG group, with lower levels of dermatitis resulting in higher satisfaction and higher levels resulting in dissatisfaction (p=0.001). Although there was no statistically significant difference in RTOG group and skin satisfaction depending on the frequency of aloe mist use (p=0.065), the group that used it 1-2 times a day (69.3%) showed a higher satisfaction level. The perceived effects of aloe mist use were statistically significant for decreasing heat sensation (p=0.001), pain (p=0.033), itching (p=0.001), and psychological stability (p=0.027), especially in the higher RTOG groups. Additionally, as cancer stage increased, the severity of radiation dermatitis also increased, which was statistically significant (p=0.001). In conclusion, radiation dermatitis is the most common side effect of radiation therapy, and it can appear in various forms depending on individual skin sensitivity and external factors during treatment. Adequate education before treatment and the use of MD Cream and aloe vera mist are recommended to reduce the incidence and manage radiation dermatitis effectively.

Improvement Effect of Corn Silk, Perilla Leaf and Grape Stem Extract Mixture against UVB-Induced Skin Damage and Compound 48/80-Induced Pruritus (옥수수수염, 들깻잎 및 포도줄기 복합추출물의 UVB 조사 피부 손상 및 Compound 48/80 유도 가려움증 개선 효과)

  • Cho, Byoung Ok;Shin, Jae Young;Che, Denis Nchang;Hwang, Young Min;Lee, Hyun Seo;Ryu, Cheol;Choi, Jiwon;Jang, Seon Il
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.231-242
    • /
    • 2016
  • This study was conducted to evaluate the synergistic protective effects of mixtures of corn silk, perilla leaf and grape stem extract (CPG mixture) against UVB-induced skin damage and compound 48/80-induced pruritus in mice. The results showed that treatment with CPG mixture exhibited much stronger suppressive effect on erythema and melanin index as well as melanin formation than treatment with ascorbic acid (AA) in UVB-irradiated mice. Moreover, the treatment with CPG mixture showed ameliorative effect on immune cell infiltration and collagen fiber destruction in UV-irradiated mice. The treatment with CPG mixture inhibited glutathione (GSH) depletion, lipid peroxidation and production of pro-inflammatory cytokines in UVB-irradiated mice. Furthermore, the treatment with CPG mixture inhibited compound 48/80-induced scratching behavior and histological changes in mice. Taken together, these results indicated that CPG mixture has potentials as functional and therapeutic materials against skin damage and itch-related skin diseases.

A Study on the Distribution of Microorganisms in Department of Radiography (영상의학과 촬영실의 미생물 분포에 관한 연구)

  • Chang, Jeong-Hyun;Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.165-171
    • /
    • 2021
  • To prevent the secondary hospital-acquired infection (cross-infection) from occurring in the general radiographic room in the department of radiology, the microbial measurement was conducted at the points making direct close contact with radiologists and patients. For the case of radiologists, the microbial measurement and incubation were focused on the x-ray tube handle of the radiation generating device, and, for the case of patients, the microbial measurement and incubation were focused on the chin supporting device, chest-contact point, and handle. Once disinfected with Aniosurf, the sterilized media were gathered and identified, and the microorganisms were confirmed. Based on the identification results, it was confirmed that the points making direct close contact with radiologists showed a value of 103 CFU for Proteus mirabilis, Staphylococcus epidermidis, Bacillus spp. and Candida spp., and that the points making direct close contact with patients showed a value of 103~5 CFU for Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, NTM(Non-Tuberculosis Mycobacteria) and Candida spp.. It was also confirmed that the types and number of microorganisms gathered from the points making direct close contact with patients were greater. Fortunately, most of the involved microorganisms were observed to be on the skin surface and are known to become extinct when disinfected in accordance with the hospital-acquired infection control rules. However, since even minor exposure to such microorganisms may be lethal for patients with reduced immunity, caution must be taken. In particular, since the points making contact with patients showed a high level of microbial measurement, it was thought that it would be necessary for radiologists and personnel having frequent access to strictly disinfect the parts, such as instruments and handles, making frequent contact with patients. The purpose of this study was to announce the importance of safe microbial control in the radiographic inspection room in hospital, and this study is expected to be used as the baseline data for preventing hospital-acquired secondary infection and Nth infectious diseases.

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Analysis of Effectiveness of Spectrum of Energy and Image Quality Evaluation by Aluminium Filter in the added Compound Filtration (에너지 스펙트럼과 화질평가를 통한 복합부가여과에서 알루미늄 여과판의 효율성 분석)

  • Kim, Sang-Hyun;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.187-197
    • /
    • 2015
  • This study analysed the effectiveness of aluminium(Al) filter in the added compound filtration for the removal of characteristic radiation by energy spectrum and image evaluation. 0.1, 0.2, 0.3 mm copper with and without 1 mm Al were evaluated. The energy spectrum was measured using the GATE and evaluated separately by each energy. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of National Cancer Screening and Cardiovascular evaluation table. In the analysis of the quality of the energy per photon spectrum with the exception of a low energy region, without Al were superior in all area. PSNR MAE, MSE, CNR, SNR and qualitative analysis were the same or slightly better. PSNR was over 30 dB and all significant and the p>0.05 in the T-test of qualitative analysis. The energy spectrum and image quality have little difference between before and after use of Al filter. Therefore, it is effective to use the Al filter for the radiation dose management with the compensation capability of DR system.

Study on Companion Dog Practice and Management System on Animal Hospital in Seoul City (서울시내 동물병원의 애완견 진료와 관리시스템에 관한 연구)

  • Kang, Dong-Joon;Chung, Byung-Hyun;Heo, Jung;Kang, Chung-Boo
    • Journal of agriculture & life science
    • /
    • v.43 no.2
    • /
    • pp.39-46
    • /
    • 2009
  • Ten animal hospitals in Seoul were selected, and of which 41,305 practice in total for recent 1 year were analyzed based on international classification of disease(ICD) of WHO. Of the entire practice, prophylaxis cases accounted for 42.2%. Of the 9,376 cases of internal diseases, digestive system diseases accounted for 4,957 cases(52.9%), respiratory system diseases 1,776 cases(18.9%), circulatory system diseases 1,239 cases(13.2%), and neoplasms diseases 413 cases(4.4%), respectively. In the estate investment expenses, to be specific, rental guarantee deposit accounted for about 50% of the entire estate cost, foregift(48%), and monthly rent(2%). Dividing the income of animal hospitals into medical service, articles selling, and pet-dog beauty, medical service accounted for 71.6% of the entire sales, selling of articles 16.7%, and pet-dog beauty 11.6%. Publicity work for the animal hospital was done mostly through web sites on internet(47%), then through local advertising papers(23.5%), and through bulletins and telemarketing(11.8%). Manpower of the animal hospitals in this study was mostly composed of veterinarians(45.5%) up to about half of the entire staffs, while there was no veterinary technician who had specialized education in that area.

Application of Biological Accelorator Mass Spectrometry by 6 MV in KIST

  • Lee, Gi-Su;Lee, Gyeong-Hui;Jo, Hye-Mi;Lee, Gwan-Ho;Kim, Jae-Yeol;Yu, Byeong-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.146.2-146.2
    • /
    • 2014
  • KIST 6MV 가속기는 이온빔 분석 그리고 가속기 질량 분석법(Accelerator mass spectrometry)으로 활용된다. 이온빔 분석으로는 RBS, TOF ERD, PIXE. ${\mu}$-Probe을 할 수 있으며 AMS(Accelerator mass spectrometry)는 액체섬광측정법(LSC)과 비교할때 민감도는 1,000배 정도로 3H, 14C, 26Al,41Ca 을 10-21 ~ 10-18 mole/mg 까지 검출 가능하여. 응용분야로는 BAMS(Biological AMS), 전통과학, 지구과학, 환경과학에 활용되고 있다. 이중 AMS의 생-의학분야(BAMS)의 응용은 최근 매우 중요하게 연구되고 있다. BAMS의 활용 연구에 사용하는 핵종으로는 주로 3H, 14C, 41Ca, 36Cl를 사용하며, 14C 화합물은 쉽게 구할 수 있고, 자연방사선 이하의 낮은 14C labeled drug 사용하기 때문에 1948년 이후 생물학 연구에 혁신적으로 활용되고 있다. 주 활용분야로는 (1) 신약개발은 임상실험 전(Phase 0) 이용되며, 14C로 표지된 bio-molecule을 자연수준의 방사선 농도에서 추적자로 사용하여 질량을 측정하는 방법을 활용. (2) 의과학분야는 인체 내에서의 추적자 연구수행 (3) 항암제 연구는 암조직 중 약물농도와 암효과의 상관성을 연구 (4) 바이오 기술 분야에서는 생약 유효물질의 체내 대사연구 등을 할 수 있어 전세계적으로 활발히 연구가 진행되고 있다. KIST에서는 6MV가속기를 BAMS 연구에 활용하기 위하여 전처리 단계의 Combustion, Gas transfer, Reduction 등을 자체 제작하여 테스트 중에 있으며, BAMS 샘플의 Gas는 호기중의 성분, 대기 성분이 있으며, Liquid는 혈액(혈장,혈청,적혈구), Solid는 DNA, 세포, 장기 뼈, 피부, 식물조직, 사료, Drug 및 그 대사 류가 있다. AMS 측정 결과는 14C/12C 비율로 나타나며 그 결과를 농도로 환산하여 분석하게 된다. 또한 분석 데이터 신뢰를 확보하기 위하여 표준시료 및 품질관리용 시료를 사용하여 BAMS분석법에 대한 검증을 실시하였다.

  • PDF

Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology (영상의학과 응급실내의 일반촬영장비와 전산화단층촬영장비 표면에서의 세균 오염에 관한 분석)

  • Hong, Dong-Hee;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.421-427
    • /
    • 2016
  • We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.

Related Factors to Visual Display Terminal Syndrome in Employees of A General Hospital in one Metropolitan City (한 광역시 종합병원 근로자의 VDT 증후군 자각증상에 대한 관련요인 연구)

  • Yoo, Se-Jong;Hong, Jee-Young;Bae, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.297-303
    • /
    • 2011
  • The existing studies of VDT syndrome have been researched only about for nurse groups without radiological technologists. The target of this study was workers who perform VDT task in general hospital placed in Daejun City such as insurance judgement, patient affairs, medical record management, medical computing service, hospital administration, and radiological sections. This study was conducted at October 15, 2009 to November 2, 2009 using structured questionnaire. Results of group A (age 20-29, less than 5 years experience at clinical site, normal staff, and unmarried group) showed significant skin and psychological conditions among recognition symptoms of VDT syndrome. Group B (age 30-39, 6-10 years experience at clinical site, managing staff, and married group) tends to be similar at orbital, whole body and muscles' frame response among recognition symptoms of VDT syndrome. Results of "Multiple Linear Regression" with dependent variable that is scores of recognition symptoms of VDT syndrome are as follows. The factors which influences for orbital-related problem is gender, health cares and obstacles during daily life. The factors which influences for whole body-related is exercise, stress and recognition for health condition and the factors which influences muscles' frame-related is 6-10 years experience at clinical site, human relationship, health cares and obstacles during daily life. These are proved to be similar by statistic analysis. There is small difference at recognition symptom of VDT syndrome between the radiological technologist and other groups in general hospital. Yet, as the working circumstance of radiological technologist gradually changes to VDT environment, the recognition symptom of VDT syndrome became conscious. This can be prevented by regular job rotation, which will escape the continuous repetition of working pattern.