• Title/Summary/Keyword: 방사선 탐지

Search Result 84, Processing Time 0.029 seconds

Development of 3D Viewer for Tree Cavity using Pulse Ultrasound (펄스 초음파를 이용한 수목 공동부 3D 구현 프로그램 제작)

  • Son, Jungmin;Kang, Sunghoon;Moon, Jongwook;Yoon, Seokkyu;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.265-271
    • /
    • 2021
  • The pattern of the tree's internal swelling depends on many causes. Since it is difficult to detect these various causes of swelling with a general method, if the state of swelling for a long time cannot be confirmed, serious damage to the trees may occur due to enlargement of the swelling area. In the method of acquiring a tree tomography image, an impulse passing through the tree is generated by tapping the sensor with a rubber mallet, and the moving speed is recorded. In this paper, to measure cracks, cavities, and swelling due to physical damage, we developed a 3D viewer that can know the internal state of a tree using a tree cross-section image acquired from Arbotom to determine the degree of swelling inside the tree. Based on this, we tried to present data that can be referred to when surgical operation of trees is required. In order to acquire a tomographic image of a tree, 6 sensors were attached to the three Yangpala and Maple trees, and a 1 m-long tree was measured using the Arbotom program, and a 3D image was implemented through the 3D Viewer created using MATLAB. In addition to simply acquiring images, the cross-sectional length and volume of the tree were measured. In the actually produced 3D Viewer, the length of the part where the swelling of the maple tree occurred was 33.12 cm, and the swelling of the yangpala tree was measured as 21.41 cm. The volume of the maple tree was measured to be 78.832 ㎤. As a result of comparing the cross-sectional image of the Arbotom and the 3D image, the same result as the real aspect of the tree was obtained, so it can be judged that the reliability of the manufactured software is also secured, and data to be applied to the surgical tree operation through the created Viewer is provided. It is believed that the damage will be minimized.

Performance Test of the Ultralow Background Gamma-Ray Measurement System (극저준위 백그라운드 감마선 측정시스템의 성능시험)

  • Na, Won-Woo;Lee, Young-Gil
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.219-226
    • /
    • 1997
  • Ultralow background gamma-ray measurement system was installed to measure and analyze gamma-rays emitted from environmental and swipe samples. The background reduction techniques applied on this system are the passive shielding to surround the HPGe detector, an active external anticosmic shield to shield cosmic-rays and the nitrogen gas supply to minimize the introduction of ubiquitous radon decay nuclei. The performance test result showed that the system background at energies between 50 keV and 2 MeV is reduced about $10^{-2}$ order and the MDA is so low as to be suitable for the environmental sample analysis. But it is appeared that the neutron produced by cosmic-ray increases the background at low energy region.

  • PDF

Fabrication of Mechanical fatigue flawed Specimen and Evaluation of Flaw Size (기계적 피로결함 시험편 제조 및 결함 크기 평가)

  • Hong, Jae-Keun;Kim, Woo-Sung;Son, Young-Ho;Park, Ban-Uk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.38-44
    • /
    • 2003
  • Performance demonstration with real flawed specimens has been strongly required for nondestructive evaluation of safety class components in nuclear power plant. Mechanical or thermal fatigue crack and intergranular stress corrosion cracking could be occured in the in-service nuclear power plant and mechanical fatigue crack was selected to study in this paper. Specimen was designed to produce mechanical fatigue flaw under tensile stress. The number of cycles and the level of stress were controlled to obtain the desired flaw roughness. After the accurate physical measurement of the flaw size and location, fracture surface was seal-welded in place to ensure the designed location and site. The remaining weld groove was then filled by using gas-tungsten are welding(GTAW) and flux-cored arc welding(FCAW). Results of radio graphic and ultrasonic testing showed that fatigue cracks were consistent with the designed size and location in the final specimens.

Verification of stereotactic target point and CT image transfer (정위적 target point 및 CT 영상전환 입증)

  • 유명진
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.47-54
    • /
    • 1999
  • Purpose: To verify the BRW coordinates of target located within the limit of XKnife hardware, and to verify the successful transfer of image data, rod detection, anatomical structure when CT images are transferred into a XKnife computer. Materials and Methods: Target coordinates of 13 patients were calculated by SCS1 computer through the rod image on the console screen and film. BRW coordinates of target and landmark calculated by SCS1 computer were compared to those acquired by XKnife localizer. Results : Vertical components of BRW coordinates of target for 13 patients are larger than -50 mm, and then the vertical components of BRW coordinates of target are localized within the limit of XKnife hardware. Average differences between XKnife and SCS1 for BRW coordinates of target and landmark were within 1 mm for AP and LAT components, 0.5 mm for VERT component. Conclusion : It was verified that the SCS1 computer is adequate tool to calculate BRW coordinates of target quickly. And by the comparison between SCS1 computer and XKnife localizer, it was verified that the image transfer into the XKnife computer was performed successfully.

  • PDF

Riboflavin Status Influences the Biosynthesis of Flavin Peptides and Related Enzyme Activities in Rat Liver Mitochondria (리보플라빈 결핍이 쥐간의 미토콘드리아의 플라빈 펩티드와 관련된 효소 활성에 미치는 영향)

  • Shin, Sook;Kim, Jae-Young;Park, In-Kook
    • The Korean Journal of Zoology
    • /
    • v.38 no.4
    • /
    • pp.498-504
    • /
    • 1995
  • The effeds of riboflavin defidency on the biosynthesis of flavin pepddes and levels of flavoenzymes and catecholamines have been investigated. The percentage of 14C. riboflavin radioactivity formed in mitochondria appeared to increase up to 2 weeks but started to decline at 3 weeks. A significant increase of radioactivity incorporation into mitochondria and into trypsin-digestable plus trypsin-non-digestibie flavin peptides was detected in riboflavin-deficient animals. More than 35% of incorporation was observed at the end of the first week and 160% higher incorporation was observed in fiavin peptide after the second week. Activities of MAO and succinate dehydrogenase were affected markedly by riboflavin status whereas those of acetyichoilnesterase were not affected. Riboflavin defidency also brought about marked reductions in levels of epineplrrine and norepinephrine. it is concluded that the levels of flavin peptides, MAO and succinate dehydrogenase, and catecholamines were affected significanily by the availability of riboflavin and in particular the duration of its depiction.

  • PDF

Mutation Frequency of Tradescantia (BNL Clone 4430) Stamen Hairs Exposed to Low Dose of Gamma Ray in the KAERI ${\gamma}$-Field (저선량율의 감마선 조사에 의한 자주 달개비의 체세포 돌연변이 출현에 관한 연구)

  • Shin Han Kwon;Young Il Lee;Kyu Hoi Chung;Jeung Haing Oh
    • Nuclear Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.161-167
    • /
    • 1981
  • For determination of mutation frequency induced by chronic irradiation of low dose gamma rays, Tradescarrfia clone 4430 was exposed to Co-60 ${\gamma}$ rays with different exposure rates from 3.6mR/day to 182R/day in or out of the Gamma Field at Kumkok Experiment Farm of KAERI. Somatic mutations based on pink mutant events of the stamen hair cells were clearly observed by the treatment. The pink mutant events were increased proportionally with increasing exposure rates of gamma ray except for relatively high dose rates of 105 R/day and 182 R/day, indicating saturation effect of mutation. The somatic pink mutations could be fairly detectable even in the low dose rate of 3.6mR/day. Therefore, this stamen hair system of Tradescantia clone 4430 seemed to be an reasonable test system for detecting mutability of low level irradiation. These results imply that artificial mutation induction in the fruit and ornamental trees could be expected in the ${\gamma}$-field.

  • PDF

Analyze Technologies and Trends in Commercialized Radiology Artificial Intelligence Medical Device (상용화된 영상의학 인공지능 의료기기의 기술 및 동향 분석)

  • Chang-Hwa Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.881-887
    • /
    • 2023
  • This study aims to analyze the development and current trends of AI-based medical imaging devices commercialized in South Korea. As of September 30, 2023, there were a total of 186 AI-based medical devices licensed, certified, and reported to the Korean Ministry of Food and Drug Safety, of which 138 were related to imaging. The study comprehensively examined the yearly approval trends, equipment types, application areas, and key functions from 2018 to 2023. The study found that the number of AI medical devices started from four products in 2018 and grew steadily until 2023, with a sharp increase after 2020. This can be attributed to the interaction between the advancement of AI technology and the increasing demand in the medical field. By equipment, AI medical devices were developed in the order of CT, X-ray, and MR, which reflects the characteristics and clinical importance of the images of each equipment. This study found that the development of AI medical devices for specific areas such as the thorax, cranial nerves, and musculoskeletal system is active, and the main functions are medical image analysis, detection and diagnosis assistance, and image transmission. These results suggest that AI's pattern recognition and data analysis capabilities are playing an important role in the medical imaging field. In addition, this study examined the number of Korean products that have received international certifications, particularly the US FDA and European CE. The results show that many products have been certified by both organizations, indicating that Korean AI medical devices are in line with international standards and are competitive in the global market. By analyzing the impact of AI technology on medical imaging and its potential for development, this study provides important implications for future research and development directions. However, challenges such as regulatory aspects, data quality and accessibility, and clinical validity are also pointed out, requiring continued research and improvement on these issues.

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF

Geometric Scheme Analysis and Region Segmentation for Industrial CR Images (산업용 CR영상의 기하학적 구도분석과 영역분할)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.4
    • /
    • pp.124-131
    • /
    • 2009
  • A reliable detection of regions in radiography is one of the most important task before the evaluation of defects on welded joints. The extracted features is to be classified into distinctive clusters for each segmented region. But conventional segmentation techniques give unsatisfactory results for this task due to the spatial superposition of intensity and low signal-to-ratio(SNR) in radiographic images. The usage of global or local processes not only provide the necessary noise resistance but also fail in classification of regions. In this paper, we presents an appropriate approach for segmentation of region-based indications in industrial Computed Radiography(CR) images. The geometric differences between welded and non-welded area which is generated on radiography as the representative regions(background, thickness, middle and welded region in steel tube image) have constructed the hierarchical structure. Although this structure is contaminated by noise, the scheme between regions can be selected by the help of local clustering based on distinctive geometric property of each region. Because of the geometric nature of the considered region and so that the region is selected layer by layer, and that the real class represents the boundary between regions, the vertical and horizontal clustering process in each layer must be judicious. In order to show the effectiveness of this approach, a comparative experiment of various segmentation method is performed on industrial steel tube CR images.

Analysis of vertical root fracture in endodontically versus nonendodontically treated teeth on patients with periodontitis (치주질환자에서 근관치료의 유무에 따른 수직 치근 파절의 실태분석)

  • Kim, Myung-Jun;Jang, Hyun-Seon;Kim, Dong-Kie;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.413-426
    • /
    • 2005
  • 수직 치근파절은 특이성을 나타내지 않기 때문에 치과의사가 정확한 진단을 하기 어렵다. 따라서 수직 치근파절의 임상적 특징, 진단적 증상을 파악하여 향후 근관치료된 치아나 치료되지 않은 치아에서 수직 치근파절의 유발인자와의 관련성 및 고찰을 통해 수직 치근파절의 예방 및 치료에 응용할 수 있을 것으로 생각된다. 연구대상은 조선대학교 부속치과병원 치주과에 내원한 환자 중 최근 2년간 144명의 환자에서 근관치료를 받았거나 받지 않았던 치아 중 임상적 및 방사선학적으로 수직 치근파절로 진단된 156개의 증례를 대상으로 하였다. 모든 불확실한 증례에서 수직 지근파절의 최종 진단은 외과적 탐지를 통해 이루어졌고, 금이 간 치아와 관련될 수 있는 치근파절의 증례의 경우는 제외되었다. 근관치료된 치아와 치료되지 않은 치아, 환자의 나이와 성별, 치아종류 및 파절된 치근부위, 자각증상의 유무를 기준으로 각각의 수치와 백분율로 분류하였다. 수직 치근파절의 증상과 증후별로 분류하였으며, 진단방법에 의한 분류, 치료방법에 따른 분류, 근관 치료 후 수직 치근파절이 발생한 기간에 따른 분류를 시행하고 통계분석을 하여 다음과 같은 결과를 얻었다. 1. 근관치료를 받지 않았던 치아의 수직 치근파절의 발생율은 58%였다. 2. 성별에 따른 발생률에 있어서 남성의 호발양상을 나타내었다. 3. 근관치료된 치아에 있어서 치료되지 않은 치아에 비해 호발연령이 낮았다. 4. 전치부의 수직 치근파절은 관찰되지 않았으며 특히, 강한 교합력을 필요로 히는 구치부에서의 높은 발생율을 나타냈다. 5. 수직 치근파절의 가장 주된 증상 및 증후는 깊은 치주낭 깊이였다. 6. 근관 치료 후 수직 치근파절이 발생한 기간은 평균 5.7년이었다. 7. 다수 증례에 있어서 3개 이하의 결손치를 가졌고, 자각증상이 나타났다. 이상의 결괴에서 한국인에 있어서 근관치료를 받지 않은 치아의 수직 치근파절은 드문 현상이 아님을 알 수 있었고 남성과 구치부에 있어서의 높은 발생율을 알 수 있었다. 그 이유로는 강한 교합력, 딱딱한 음식의 저작습관, 치조골 흡수에 따른 낮은 저항성, 골 유연성의 저하 등으로 여겨진다. 그러나, 수직 치근파절은 아직까지 정확한 진단을 내리기는 여전히 어려운 상태이며, 이를 위한 다양한 진단방법 및 더 나은 연구가 필수적이라 하겠다. 그리고, 향후 보다 많은 증례에 대한 분석, 치주질환에 이환되지 않은 경우의 분석, 치료 후 생존 기간에 대한 고찰 등도 필요하리라 사료된다.