• Title/Summary/Keyword: 방사선 촬영

Search Result 2,076, Processing Time 0.027 seconds

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

EFFECTIVE DOSE FROM CONE BEAM CT FOR IMAGING OF MESIODENS (상악 정중과잉치 진단을 위한 cone beam CT의 유효선량)

  • Han, Won-Jeong;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.273-279
    • /
    • 2012
  • Purpose : This study was aimed to calculate effective dose from cone beam CT and compare effective dose from periapical and panoramic radiography for mesiodens. Materials and Methods : Upper anteiror periapical, panoramic radiography and cone-beam CT were taken for diagnosis of mesiodens. The effective dose were calculated by using an anthropomorphic phantom loaded with thermoluminescent dosimeters at the 23 sites related to sensitive organs. Results : The highest absorbed doses were received by the mandibular body, parotid gland and cheek from periapical, panoramic and cone-beam CT, respectively. The effective doses for periapical, panoramic radiography and cone-beam CT measured 2, 18 and 48 ${\mu}Sv$. Conclusion : Cone-beam CT, although providing additional diagnostic benefits, exposes patients to higher levels of radiation than conventional periapical and panoramic radiography.

Radiographic Status of the Visited Patients at University Hospital Emergency Room (한 대학병원 응급실 내원환자의 방사선촬영 실태)

  • Ahn, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distriution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 1270 emergency outpatients who visit during JAN, 2009at ER of the general hospital in Gwang city. The results is as follows : Emergency radiography rate of simple radiography was 56.6%, special radiography 2. 5%, CT 34.2%, and ultrasonography 6.7%, In simple radiography rate. a high rate was distributed on male(63.6%), thoracicsurgery part(90.0%), admission patient(77.9%), and long stayed patient at ER. In special raiography rate, a high rate was obsurved in urologic part(28.6%), and in CT rate, observed neurosurgerty part(49.2%) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8%) and internal medicine part(15.9%). There are distributed regional radiography rate in radio-graphic type that chest(55.3%) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0%) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neuro surgery, chest(90.0%) in thoracic surgery, abdomen(58.0%) in general surgery, spine(40.0%) in neuro surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiopraphic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transferred patient(2.7) in patient type, and on nurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional party was highly distributed on chest(998 case number.) Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography. Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always sitted with CT room and monitoring patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiopraphy should be established in ER area, and the radioprapher of this room should be stationed radiologic technician who is career and can implement emergency patient care and The disposition of men which is appropriate with emergency patient increase is necessary.

Convergence and integration study related to development of digital contents for radiography training using dental radiograph and augmented reality (치과방사선사진과 증강현실을 활용한 방사선촬영법 숙련용 디지털 콘텐츠 개발에 대한 융복합 연구)

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.441-447
    • /
    • 2018
  • This study aims to develop digital techniques that enable repeated practice of dental radiography using augmented reality technology. A three-dimensional object was fabricated by superimposing a photograph of an adult model and a computed tomography image of a manikin phantom. The system was structured using 106 radiographs such that one of these saved radiographs is opened when the user attempts to take a radiograph on a mobile device. This system enabled users to repeatedly practice at the pre-clinical stage without exposure to radiation. We attempt to contribute to enhancing dental hygienists' competency in dental radiography using these techniques. However, a system that enables the user to actually take a radiograph based on face recognition would be more useful in terms of practice, so additional studies are needed on the topic.

A Study on the Environmental Condition and Safety in Dental Radiographic Room (치과 방사선 촬영실의 촬영실태와 방사선 안전관리 실태에 관한 조사 연구)

  • Kang, Eun-Ju;Lee, Kyung-Hee;Ju, On-Ju
    • Journal of dental hygiene science
    • /
    • v.5 no.2
    • /
    • pp.83-88
    • /
    • 2005
  • In spite of relatively low level of radiation dose used at dental clinics, long term exposure may be harmful, so radiation workers at dental clinics must be well aware of its danger. This study was radiation safety management by dental hygienists in order to take preventive measures for dental hygienists and suggest ideas to develop radiation safety training programs. For this, we contacted dental hygienists working at the local dental clinics for 4 months from December of 2003 to march of 2004 and obtained the following findings. 1. Regarding the intraoral radiographic method, the average daily photographing frequency of standard films stood at one to five pieces (47.5%), and the average weekly photographing frequency of digital radiation medicine stood at less than one piece (69.8%), and the average weekly photographing frequency of bitewing films stood at less than one piece (67.7%), and and the average weekly photographing frequency of occlusal films stood at less than one piece (95.5%), and the dentistries whose average weekly photographing frequency of pediatric films stood at one to five pieces accounted for 47.1 percent. 2. Regarding the extraoral radiographic method, the average weekly photographing frequency of panorama film stood at one to five pieces (63.7%), and less than one piece (20.9%), the average weekly photographing frequency of cephalometric film stood at less than one piece (72.3%), and one to five pieces (20.1%). 3. Concerning the radiation safety management training program, only 18.7% of total 278 surveyed attended the training progra., Attendance tendency of the training program by general characteristics showed statistically significant difference according to age (p<0.01), working experience (p<0.001), and marital status (p<0.01). 4. When asked about the protective equipments against radiation exposure, 40.6% of them said "modest", and 71.1% appeared equipped with led apron as a protective tool.

  • PDF

3차원 치료계획용 전산화단층촬영에서 영상증강을 위한 최적의 프로토콜에 관한 연구

  • 이상규;이석;김주호;백종걸;조정희;신동봉;박재일
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • 1. 목적 : 방사선종양학과에서 3차원 치료계획용 전산화단층촬영 시 조영제 주입율에 따른 CT 값(hounsfield unit, H.U) 변화를 정량적으로 평가하여 최적의 영상증강효과 및 방사선치료계획을 위한 기초 프로토콜을 제시하고자 한다. 2. 대상 및 방법: 연세암센터 방사선종양학과에서 3차원 치료계획용 전산화단층촬영을 시행한 상복부(폐암)환자 20명을 대상으로 하였다. 조영제 양(130mL)은 일정하게 고정하였고, 조영제주입율을 1.2, 1.5, 2.0 mL/sec로 변화시켜가며 조영제를 주입하면서 3차원 방사선치료계획영상에 적합한 조영제주입율(contrast flow rate)과 지연시간(delay time)을 도출하였고, CT 값을 측정하여 정량적 평가를 시행하였다. 관심부위는 폐동맥과 폐정맥으로 하였다. 그리고, 환자 기본정보, 조영제주입율, H.U 등 영상증강에 영향을 미치는 인자들을 통계처리 프로그램인 SPSS를 이용하여 최적의 영상을 획득할 수 있는 기초 프로토콜을 작성하였다. 3. 결과 : 폐암환자의 전산화단층촬영영상 획득 시 3차원 방사선치료계획에 적합한 영상을 얻을 수 있는 조건중 조영제주입율은 1.5 mL/sec 이었고, 지연시간은 $60{\sim}70$초이었다. 통계처리를 수행한 결과 환자의 기본정보 및 조영제주입율 등이 영상증강에 영향을 미치는 인자임을 알 수 있었다. 본 연구에서 작성한 기초 프로토콜을 이용하여 3차원 방사선치료계획 시 정확한 종양 및 정상조직 설정이 용이하게 되어 방사선치료 효율을 극대화 할 수 있었다. 4. 결론 : 방사선종양학과에서 3차원 치료계획용 전산화단층촬영 시 사용할 수 있는 기초적인 영상획득 프로토콜을 도출하였고, 향후 더 많은 임상경험과 정량적 평가가 수반된다면 임상에 적극 사용할 수 있을 것이라 사료된다.

  • PDF

Analysis of Radiation Protection, Awareness and Attitude of Radiological Technologist in Mammography Room (유방촬영실에 근무하는 방사선사의 방사선 방어, 인식 및 태도에 관한 분석)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.557-565
    • /
    • 2017
  • This study was conducted to investigate the radiation protection, awareness, and attitude of radiological technologists in the mammography room due to the low energy use of breast imaging. Data collection was performed by 222 independent radiological technologists in the breast and breast clinic of six hospitals except Jeju Island. The independent sample t-test and oneway variance analysis were performed. As a result, it was found that the lower the number of men(p<0.05), the age of 30s(p<0.05), the marriage(p<0.05), the work experience of more than 10 years(p<0.05), the working hours of 8 hours(p<0.01), the less the impact of radiation(p<0.01), the more important it was to radiation defense. appear. This is thought to be influenced by the work specificity and work environment of the mammography room, and it will be used as a basic data to raise awareness and act on the exposure through analysis with other factors.