Semi-Longitudinal Study on Growth Development of Children Aged 6 to 16 (한국인 정상아동 6세~16세의 악안면 성장에 관한 준종단적 연구)

  • Jeong, Mi;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.51-72
    • /
    • 1999
  • In orthodontic field, it is very important to understand the normal growth. Such an understanding can be derived from observation of normal growth in various samples from childhood to adulthood, and this builds a foundation from which growth abnormality or variation can be defined. Thus, a broad data collection of normal children, as well as basic study reviewing such data become necessary. The relationship between the mean values of cephalometric measurements in Growth and Development was studied among the groups(boys and girls) of Korean chidren from the ages 6-years to 16-years. 220 boys 170 girls were chosen as subjects : Cephalometric X-ray were taken for 3 years and hard tissue analysis on McNamara and Ricketts Analysis which was divided into measurements of 5 parts(Cranial base, Cranial base and Maxilla & Mandible, Maxilla and Mandible, Mandible, Dental measurements). The relationship of craniofacial growth was studied. The following conclusions were obtained: 1. There were statistically significant differences in anterior cranial base between the two sexes of 14 and 15-year grouips. 2. In comparison of growth amounts among different age groups, statistically singnificant difference in Posterior facial height exhisted among $10\~11,\;12\~13\;and\;14\~15$ year-old interval groups. This pattern increased with aging. 3. Na perpendicular to A showed earlier growth peak in females(11-12years) than males(12-13years). When horizontal measurements of point A and Pogonion are compared, mandibular growth appeared to be greater. 4. Maximum growth peak of cranial base and mandible was earlier in females (11-12years) than males(13-14 years). 5. Upper central incisor flared out with aging, and there were increases in lower incisor to A-Pg, and lower incisor inclination There was significant difference between the two sexes in 10-year-old group.

  • PDF

Utilization Rate and Related Factors of Unified Health Sub-center Among Rural Residents (통합보건지소 설치 전후 주민들의 보건지소 이용율 변화 및 관련요인)

  • Hwang, Tae-Yoon;Kang, Pock-Soo;Kim, Seok-Beom;Lee, Kyeong-Soo;Kang, Young-Ah
    • Journal of agricultural medicine and community health
    • /
    • v.27 no.2
    • /
    • pp.107-126
    • /
    • 2002
  • Health sub-centers(HSCs) have played an important role in primary health care in rural area in Korea. The unification of neighboring HSCs was a strategy to improve the role of HSCs. This study was conducted to reveal the efficacy of the unified HSC established in Yangbuk-myeon, Gyeongju-si in1997. The utilization patterns of HSC and its related factors, and satisfaction of consumer on HSC were compared before and after unification of two HSCs in Gampo-eup, Yangnam-myeon using questionnaire survey, and also the statistics of medical care services and public health services were compared. Four hundred forty nine subjects were questioned in survey, 156 from Gampo-eup, 147 from Yangbuk-myeon, and 146 from Yangnam-myeon. Following unification, the utilization rates and the frequency of visits in Gampo-eup declined. In all three areas, chronic illness was the common factor influencing the utilization and change in frequency of visits to the unified HSC. Following unification, aspects of consumer satisfaction, for example; accessibility and affordability decreased in Gampo-eup, but increased in both Yangbuk-myeon and Yangnam-myeon. The statistics relating to medical care, X-ray examination, home visiting service, vaccination, and health education showed an increase for the unified HSC when compared to the sum of the statistics for the previous two. The execution rates for other public health services were the same, or a little decreased. Clinical laboratory examinations and the issuing of civil affair documents were new services offered by the unified HSC. It is concluded, the overall consumer satisfaction with the unified HSC was improved. In Gampo-eup, where after unification there was no HSC, it seemed to be a barrier to accessing the unified HSC. The effect of the unified HSC, in the respect of medical care and public health services, was not as significant as expected at the time of being established. Therefore, the strategies to reenforce the unified HSC should be developed to provide all residents with comprehensive primary health care services.

  • PDF

The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy (양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증)

  • Hong, Gun-Chul;Jang, Joon-Yung;Park, Se-Joon;Cha, Eun-Sun;Lee, Hyuk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2017
  • Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 mm) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of $0^{\circ}$. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 mm in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 mm) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 mm) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 mm sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 mm and 22 mm, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 mm, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

  • PDF

THE EFFECT OF DISTAL MOVEMENT OF UPPER MOLAR USING THE PENDULUM APPLIANCE (Pendulum 장치의 상악대구치의 원심이동에 대한 효과)

  • Lee, Chang-Seop;Kim, Jae-Gwang;Kang, Dug-Il;Song, Kwang-Chul;Jung, Hyun-Ku;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.488-495
    • /
    • 2001
  • Treatment of class II malocclusions require distalization of maxillary molars into class I relationship. Intraarch distal molar movement techniques have recently assumed an important role in young patients. In this study, the dental and skeletal effects of the pendulum appliance were evaluated by means of cephalometric radiographs. The samples were consisted of 19 patients: 11 females and 8 males, mean age $11.68{\pm}1.52$ years. Measurements were obtained from cephalometric prior to and the day of removal of the pendulum appliance. Treatment changes were analyzed. The following results were obtain. 1. The pendulum appliance produced $2.94{\pm}1.54mm$ distal molar movement with a mean intrusion of $1.17{\pm}0.97mm$, mean period $18.13{\pm}7.95$ weeks. 2. The anchor tooth was $1.34{\pm}1.40mm$ forward movement and $0.48{\pm}0.99mm$ extrusion, and labial tilting of incisors. 3. The angle between palatal plane and mandibular plane increased significantly. 4. There was no significant difference in according to 2nd molar position. 5. Total movement was consisted of 74% distal movement of 1st molar and 26% forward movement of the anchor tooth.

  • PDF

Root Uptake of $^{54}Mn,\;^{60}Co,\;^{85}Sr\;and\;^{137}Cs$ Deposited at Different Times during the Growing Season of Rice (벼 재배 기간중 침적시기에 따른 Root Uptake of $^{54}Mn,\;^{60}Co,\;^{85}Sr,\;^{137}Cs$의 뿌리흡수)

  • Choi, Yong-Ho;Jo, Jae-Seong;Lee, Chang-Woo;Hong, Kwang-Hee;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.255-263
    • /
    • 1995
  • Root uptakes of $^{54}Mn,\;^{60}Co,\;^{85}Sr\;and\;^{137}Cs$ by rice were studied through a greenhouse experiment in which the upper 20 cm of the culture box was filled with an acidic loamy-sandy soil and a mixed solution of the radionuclides was applied to the surface water on the soil 2 days before, and 5 different times after, transplanting. Percent uptakes of the radionuclides to rice tops varied $3.4{\sim}13.7%,\;0.03{\sim}0.1%,\;0.6{\sim}1.5%,\;0.02{\sim}0.15%$, respectively, with application time. Among radionuclides, soil-to-plant transfer factors decreased, on the whole, in the order of $^{54}Mn>^{85}Sr>^{60}Co{\geq}^{137}Cs$, and among plant parts, in the order of straw > chaff > hulled seed. Transfer factors $(m^2/kg-dry)$ in hulled seed were, depending on application time, $1.2{\times}10^3{\sim}5.0{{\times}10^3\;for\;^{54}Mn,\;1.6{\times}10^5{\sim}2.6{\times}10^4\;for\;^{60}Co,\;1.1{\times}10^4{\sim}7.6{\times}10^4\;for\;^{85}Sr\;and\;5.2{\times}10^5{\sim}7.0{\times}10^4\;for\;^{137}Cs$. The highest factors of all the radionuclides in straw came from the application at 67 days after transplanting while those of $^{54}Mn,\;^{60}Co\;and\;^{85}Sr$ in hulled seed appeared at later applications. The data from this studv can be referred to in assessing the radiological impact of an accidental contamination during the rice growth.

  • PDF

Evaluation and Consideration on Environmental Radiation Analysis of Yeong-Gwang Nuclear Power Plant Site Inside&Outside(2000~2009 year) (영광원전 부지 내.외부의 환경방사능 분석에 대한 평가 및 고찰(2000~2009년))

  • Han, Sang-Jun;Lee, Seung-Jin;Lee, Goung-Jin;Lee, Na-Young;Kim, Hee-Gang;Mun, Ji-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.71-78
    • /
    • 2011
  • Yeong-Gwang N.P.P Private Environment Supervisory Organization analyzed over 3,000 samples including 10 marine and 24 land samples from the year 2,000 to 2009. According to the results of the analysis, artificial nuclides that resulted from the effect of Yeong-Gwang Nuclear Power Plant operations were not detected in most samples. However, from the rain and seawater samples, which were taken from inside the plants such as the intake, the discharge and the observatory, $^3H$ was detected although it was below the regulation level. The $^3H$ concentration detected in the rain taken from the observatory, by the yearly average criterion, was 30.5~40.0 $Bq{\cdot}L^{-1}$, which is around 20 times the $^3H$ concentration detected in the surroundings of the power plants, but it is 0.1% of the regulation level of 40,000 $Bq{\cdot}L^{-1}$. Also, $^3H$ concentration detected in the seawater taken from the intake and the discharge, by the yearly average criterion, was 2.75~17.8$Bq{\cdot}L^{-1}$, which means the concentration detected in the discharge is about 140~280% higher than that detected in the intake except the year 2006. Based on these results, it was determined that, although lower than the regulation level, the $^3H$ in gas and liquid form detected in the rain and seawater sampled from the observatory and the discharge was released into the environment from the power plants. Therefore, regular monitoring and analysis is required on the level of $^3H$ in the observatory and the discharge.

Technical Standards and Safety Review of the Low and Intermediate Level Radioactive Waste Disposal Facility (중.저준위 방사성폐기물 처분시설에 대한 기술기준 및 안전심사)

  • Cheong, Jae-Hak;Lee, Kwan-Hee;Lee, Yun-Keun;Jeong, Chan-Woo;Rho, Byung-Hwan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.357-368
    • /
    • 2008
  • On July 31, 2008, the Government issued the construction and operation permit for the first low and intermediate level radioactive waste disposal facility in the Republic of Korea. In this paper, the fundamental regulatory framework, regulatory requirements and technical standards of the disposal facility are introduced, and the phased review process adopted for evaluation of the safety of the facility is briefly described. The Atomic Energy Act sets forth a stepwise regulatory framework for the whole life-cycle of the disposal facility such as siting, design, construction, operation, closure and institutional control. More detailed regulatory requirements and technical standards are stipulated in the subsequent regulations of the Atomic Energy Act and a series of Notices issued by the Ministry of Eduction, Science and Technology. The Korea Institute of Nuclear Safety, as entrusted by the Ministry under the Atomic Energy Act, conducted safety review on the disposal facility, and evaluated the compliance with relevant criteria in all technical elements(i.e. siting and structural safety, radiological environmental impact, operational safety, systems and components, quality assurance, and total systematic performance assessment, etc.). The overall safety review process can be phased into inception phase, initial review phase, main review phase and completion phase. The review results were reported to and deliberated by the five Sub-committees of the Special Committee on Nuclear Safety, and then reported to the Ministry. The Ministry issued the construction and operation permit of the disposal facility through the deliberation of the review results by the Nuclear Safety Commission. Hereafter, the safety of the repository will be reassured by a series of subsequent regulatory inspections and reviews under the Atomic Energy Act. In addition, the licensee's continuous implementation of the "Safety Promotion Plan" may also enhance the long-term safety of the repository and contribute to build-up the confidence of the safety case.

  • PDF

Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study (두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study))

  • Lee, Ji-Eun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.169-174
    • /
    • 2008
  • Statement of problem: Changes of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. It was proposed that bone-retention elements such as microthreads at the coronal part of implant might help maintain the marginal bone level. Purpose: This study was designed to evaluate the effect of microthread configuration within the marginal coronal portion of the implant fixture at the marginal bone changes after loading around two different external hex implants. Material and methods: Twenty-four patients were included and randomly assigned to treatment with $Br{{\aa}}nemark$ system implants (Group 1, rough-surfaced implants, n=20) and Oneplant system implants (Group 2, rough-surfaced neck with microthreads, n=20). Clinical and radiographic examinations were conducted at baseline (implant loading) and 1 year postloading. Data analysis was performed by the SAS statistical package version 9.1.3 (SAS Institute, Cary, NC, USA) and the final model was calculated by the MIXED procedure (three-level ANCOVA) for marginal bone change of each test group at baseline and 1 year follow-up. Results: Comparing to baseline, significant differences were noted in marginal bone level changes for the 2 groups at 1 year follow-up (P<0.05). Group 1 had a mean crestal bone level changes of $0.83{\pm}0.31mm$; Group 2 had a mean crestal bone level changes of $0.44{\pm}0.36mm$. Rough-surfaced with microthreads implants showed significantly less marginal bone loss than rough surfaced neck without microthread implants. Conclusion: A rough surface with microthreads at the implant was beneficial design to maintain the marginal bone level against functional loading.

Retrospective study on survival and complication rates of posterior single implant according to the implant diameters, lengths and position (구치부 단일 임플란트의 직경과 길이, 식립 위치에 따른 생존율 및 합병증의 발생률에 대한 후향적 연구)

  • Soo-Young Hong;Seon-Ki Lee;Jin-Han Lee;Jae-In Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.101-112
    • /
    • 2023
  • Purpose. This retrospective study was to investigate the survival and complication rates of posterior single implant according to the implant diameters, lengths and position. Materials and methods. Patients who had been restored single implant prosthesis in the posterior area by the three prosthodontists in the department of prosthodontics, Daejeon dental hospital of Wonkwang university, in the period from February 2014 to May 2018 were selected for the study. A total of 505 patients with 697 implants were observed. The survival and complications of implants were investigated using electronic medical records and radiographs. Fixture diameters, lengths, position, patient's sex and age were assessed as possible factor affecting the survival and complications of implants. Results. 3-year cumulative survival rates of posterior single implants were 98.5% and 5-year cumulative survival rates were 94.4%. 5-year cumulative survival rates were higher in implants with diameter > 4.0 mm (97.0%) than implants with diameter ≤ 4.0 mm (89.5%), and in females (98.8%) than males (92.4%). There were statistically significant differences (P < .05). The mechanical complication rate was 20.1% and the biological complication rate was 4.7%. Complications occurred in order of abutment screw loosening (7.5%), decementation (6.3%), proximal contact loss (3.7%) and so on. Abutment screw loosening occurred more frequently in the lower molar region (10.5%), in males (9.5%) than females (5.1%), and in patients aged < 65 years (9.4%) than patients aged ≥ 65 years (5.1%). There were statistically significant differences (P < .05). Conclusion. The 5-year cumulative survival rates were higher in implants with diameter > 4.0 mm than implants with diameter ≤ 4.0 mm and in females than males. Abutment screw loosening which was the most commonly occurring complication occurred more frequently in the lower molar region, in males than females, and in patients aged < 65 years than patients aged ≥ 65 years. There were statistically significant differences.

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.