• Title/Summary/Keyword: 방사선 실험

Search Result 1,722, Processing Time 0.019 seconds

Development for Fishing Gear and Method of the Non-Float Midwater Pair Trawl Net (II) - Opening Efficiency of the Model Net according to Front Weight and Wing-end Weight - (무부자 쌍끌이 중층망 어구어법의 개발 (II) - 추와 날개끝 추의 무게에 따른 모형어구의 전개성능 -)

  • 유제범;이주희;이춘우;권병국;김정문
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.189-196
    • /
    • 2003
  • In this study, the vertical opening of the non-float midwater pair trawl net was maintained by controlling the length of upper warp. This was because the head rope was able to be kept linearly and the working depth was not nearly as changed with the variation of flow speed as former experiments in this series of studies have demonstrated. We confirmed that the opening efficiency of the non-float midwater pair trawl net was able to be developed according to the increase in front weight and wing-end weight. In this study, we described the opening efficiency of the non-float midwater pair trawl net according to the variation of front weight and wing-end weight obtained by model experiment in circulation water channel. We compared the opening efficiency of the proto type with that of the non-float type. The results obtained can be summarized as follows:1. The hydrodynamic resistance was almost increased linearly in proportion to the flow speed and was increased in accordance with the increase in front weight and wing-end weight. The increasing rate of hydrodynamic resistance was displayed as an increasing tendency in accordance with the increase in flow speed. 2. The net height of the non-float type was almost decreased linearly in accordance with the increase in flow speed. As the reduced rate of the net height of the non-float type was smaller than that of the net height of the proto type against increase of flow speed, the net height of the non-float type was bigger than that of the proto type over 4.0 knot. The net width of the non-float type was about 10 m bigger than that of the proto type and the change rate of net width varied by no more than 2 m according to the variation of the front weight and wing-end weight. 3. The mouth area of the non-float type was maximized at 1.75 ton of the front weight and 1.11 ton of the wing-end weight, and was smaller than that of the proto type at 2.0∼3.0 knot, but was bigger than that of the proto type at 4.0∼5.0 knot. 4. The filtering volume was maximized at 3.0 knot in the proto type and at 4.0 knot in the non-float type. The optimal front weight was 1.40 ton.

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF