• Title/Summary/Keyword: 방사선 선량

Search Result 3,560, Processing Time 0.032 seconds

Radiation Dose Measurement of D-Shuttle Dosimeter for Radiation Exposure Management System (방사선피폭관리시스템를 위한 D-Shuttle 선량계의 방사선 선량측정)

  • Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.321-328
    • /
    • 2017
  • The purpose of the study is to provide basic data for the management of individual exposure and the monitoring of natural radiation dose using D-Shuttle dosimeter (Chiyoda Technol Corporation, Tokyo, Japan). The dose was calculated using D-Shuttle dosimeter. The dose was 1.346 mSv when exposed for 400 days, the annual dose per year was 1.228 mSv/year and the average dose per hour was $0.014{\mu}Sv/hr$. Domestic individual external dose (1.295 mSv/year = Korea average natural individual external dose) and domestic additional dose per year is -0.0663 mSv/year. D-Shuttle is a personal dosimeter for radiation monitoring. It can be used as a very useful dosimeter for ALARA because of its excellent detection capability of radiation, real-time radiation exposure management, alarm function of radiation work, and efficient and easy to use personal radiation dose management.. Radiation monitoring equipment for radiation workers and local residents can be used for radiation monitoring in hospitals, industry, medical sites, nuclear accident areas and hazardous areas in non-destructive areas.

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

The Study for Radio Protection According to a Possible Danger of Exposure During low energy X-ray Examination (저 에너지 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Jeong, Cheon-Soo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.187-188
    • /
    • 2011
  • 저 에너지 방사선검사 시 부득이하게 방사선 노출을 받게 되는 방사선 작업종사자나 환자의 보호자가 위치와 거리에 따른 방사선 피폭 선량의 감소 방안을 알아보고자 한다. Ion chamber mode 2026c, Reader기 20X6-1800을 사용하여 구강내 검사와 구강외 검사의 각각 검사실과 조정실에서의 관전압의 변화, 관전류와 조사시간의 변화, 조사방향의 변화에 따라 선량을 측정하였다. 그 결과 검사실 안에서는 최고선량이 평균 $702.8{\mu}R$으로 측정 되었으며, 조정실 안에서 측정하였을 경우 $20{\mu}R$이하의 낮은 선량을 보였으며, 후방검사보다 측방검사가 낮은 선량으로 나타났다. 방사선검사 시 위치와 거리에 따른 조사선량을 비교 분석하여, 적절한 거리 확보와 조사되는 중심방사선을 기준으로 측방($90{\sim}135^{\circ}$)에 위치함으로써 방사선 방어에 도움을 줄 것이며, 차폐문을 이용하여 방사선 피폭으로부터 감소 효과를 볼 수 있을 것이다.

  • PDF

Radiation Exposure Analysis of Female Nuclear Medicine Radiation Workers (여성 핵의학 방사선종사자의 피폭요인 분석)

  • Lee, Juyoung;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.209-225
    • /
    • 2016
  • In this study, radiation workers who work in nuclear medicine department were analyzed to find the cause of differences of radiation exposure from General Characteristic, Knowledge, Recognition and Conduct, especially females working on nuclear medicine radiation, in order to pave the way for positive defense against radiation exposure. The subjects were 106 radiation workers who were divided into two groups of sixty-four males and forty-two females answered questions about their General Characteristic, Knowledge, Recognition, Conduct, and radiation exposure dose which was measured by TLD (Thermo Luminescence Dosimeter). The results of the analysis revealed that as the higher score of knowledge and conduct was shown, the radiation exposure decreased in female groups, and as the higher score of conduct was shown, the radiation exposure decreased in male groups. In the correlation analysis of female groups, the non-experienced in pregnancy showed decreasing amount of radiation exposure as the score of knowledge and conduct was higher and the experienced in pregnancy showed decreasing amount of radiation exposure as the score of recognition and conduct was higher. In the regression analysis on related factors of radiation exposure dose of nuclear medicine radiation workers, the gender caused the meaningful result and the amount of radiation exposure of female groups compared to male groups. In the regression analysis on related factors of radiation exposure dose of female groups, the factor of conduct showed a meaningful result and the amount of radiation exposure of the experienced in pregnancy was lower compared to the non-experienced. The conclusion of this study revealed that radiation exposure of female groups was lower than that of male groups. Therefore, male groups need to more actively defend themselves against radiation exposure. Among the female groups, the experienced in pregnancy who have an active defense tendency showed a lower radiation exposure. Thus, those who have never been pregnant need to have a more active defensive conduct for the future possibility of pregnancy.

Evaluation of Skin Dose of Intensity Modulated Radiation Therapy in Breast Cancer Patients (유방암환자의 세기조절방사선치료에서 피부선량 평가)

  • Kim, Sung-Kyu;Kim, Myung-Se;Yun, Sang-Mo
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.167-171
    • /
    • 2007
  • In the case of radiotherapy following breast conservation therapy for breast cancer patients, the characteristic of skin dose was investigated in the treatment of intensity modulated radiation therapy (IMRT) for breast cancer patients by comparing and analysing entrance skin dose irradiated during radiotherapy using tangential technique radiotherpy, and IMRT. The calculation dose irradiated to breast skin was compared with TLD measurement dose in treatment planning by performing the two methods of radiotherapy using tangential technique, and IMRT in treatment planning equipment. The skin absorbed dose was measured to pass a nipple by spacing of 1 cm distance from center to edge of body. In the radiotherapy of tangential technique, for the irradiation of 180 cGy to PTV, the calculation dose was ranged from 103.5 cGy to 155.2 cGy, measurement dose was ranged from 107.5 cGy to 156.2 cGy, and skin dose in the center was maximum 1.45 times more irradiated than that in the edge. In the IMRT, for the irradiation of 180 cGy to PTV, the calculation dose was ranged 9.8 cGy at 80.2 cGy, measurement dose was ranged 8.9 cGy at 77.2 cGy, and skin dose in the center was maximum 0.23 times less irradiated than that in the edge. IMRT was more effective for skin radiation risks because radiation dose irradiated to skin in IMRT was much less than that in radiotherapy of tangential field technique.

  • PDF

Assessment of Occupational Dose to the Staff of Interventional Radiology Using Monte Carlo Simulations (몬테카를로 방법을 이용한 중재방사선시술자에 대한 선량평가)

  • Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.213-217
    • /
    • 2014
  • Medical operations and diagnosis using interventional radiology techniques have been increased. The management and monitoring of occupational radiation exposure to the staff of interventional radiology become important, specially because they stand in close proximity to the patient. The operational radiation protection quantity, Hp(10) which can be obtained from personal dosimeter do not always represent the effective dose to the staff. So, in this study, to estimate the critical organ doses to the staff of interventional radiology, Monte Carlo calculations with mathematical human phantom and dose measurements with personal dosimeters were carried out for the major interventional radiology procedures using C-arm. Results showed that the values of Hp(10) measured by personal dosimeters were higher than critical organ doses which were calculated. And the calculated dose to thyroids was much higher than those of other critical organ doses. For the proper radiation protection of the medical staff of interventional radiology, additional radiation protection for thyroids as well as for whole body shielding like wearing a lead apron should be considered.

Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator (구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성)

  • Lee, Kyung Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.465-471
    • /
    • 2012
  • In this study, three dimensional X-ray dose distribution from dental X-ray generator system was measured by ALOKA PDM-117 dosimeter. The X-ray dose distribution will be change with XCP-DS FIT in oral shot, because the distance between X-ray generator and the dosimeter. The X-ray dose change affects on patient exposure and radiograph image quality. Therefore, it is important to obtain relation between the X-ray dose and the distance. The X-ray dose at the central position was decreased with increasing the distance. Furthermore, the dose at the edge of the X-ray flux was increased with increasing the distance. The increased dose affects on the patient radiation exposure. The present results will provide for good dental radiograph image and reducing radiation over-exposure on patient.

Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea (한국에서 방사선 관련 종사자들의 개인피폭선량 실태에 관한 연구)

  • Lim, Bong-Sik
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.185-195
    • /
    • 2006
  • Purpose: This study investigated the status of radiation exposure doses since the establishment of the "Regulations on Safety Management of Diagnostic Radiation Generation Device" in January 6, 1995. Method: The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organizations, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Results: Among 57,136, men were 40,870(71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors(22.7%), nurse(2.9%) and others(24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv(limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. Conclusion: The total exposure per worker was siginifcantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided.

  • PDF

Considerations on the Concept of Dose Constraint (선량제약 개념에 대한 고찰)

  • Chang, Si-Yeong;Chung, Kyeong-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.329-338
    • /
    • 1996
  • 최근에 우리나라가 공식 회원국으로 가입한 서방 경제협력개발기구(OECD)/원자력기구(NEA) 산하의 방사선 방호 및 보건위원회(CRPPH)에서는 유럽연합(EC)의 전문가그룹과 합동으로 국제방사선방호위원회(ICRP)의 권고 60의 방사선 방호 최적화 원칙에 공식적으로 도입된 이른 바 '선량제약(dose constraint)' 개념에 대한 위원회의 논의 및 검토결과를 OECD/NEA의 공식보고서로 발간하였다. 이 보고서는 선량제약의 개념과 의미를 논리적으로 합리화하기 위하여 발간된 것이다. 선량제약이란 용어와 개념은 새로워 보이지만 실상은 전혀 새로운 것이 아니다. 우리나라에서도 방사선 방호의 실무현장에서 용어나 의미는 조금 다르다 할 수 있어도 이 개념을 부분적으로 적용해왔다고 할 수 있다. 예를 들어, 선량한도 이하의 낮은 선량으로 작업자의 피폭을 제한하기 위하여 도입된 '연간 선량목표치' 또는 '방사성 물질의 방출목표관리치' 등이 여기에 해당될 것이다. 따라서, OECD/NEA의 공식보고서를 번역한 이 해설논문이 국내의 방사선 방호분야에서 활약하고 있는 정책 입안자, 연구자, 규제업무자, 방사선 관리실무자 등 방사선 방호 업무분야의 관련자들에게 도움이 되었으면 한다.

  • PDF

EFFECTIVE DOSE FROM CONE BEAM CT FOR IMAGING OF MESIODENS (상악 정중과잉치 진단을 위한 cone beam CT의 유효선량)

  • Han, Won-Jeong;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.273-279
    • /
    • 2012
  • Purpose : This study was aimed to calculate effective dose from cone beam CT and compare effective dose from periapical and panoramic radiography for mesiodens. Materials and Methods : Upper anteiror periapical, panoramic radiography and cone-beam CT were taken for diagnosis of mesiodens. The effective dose were calculated by using an anthropomorphic phantom loaded with thermoluminescent dosimeters at the 23 sites related to sensitive organs. Results : The highest absorbed doses were received by the mandibular body, parotid gland and cheek from periapical, panoramic and cone-beam CT, respectively. The effective doses for periapical, panoramic radiography and cone-beam CT measured 2, 18 and 48 ${\mu}Sv$. Conclusion : Cone-beam CT, although providing additional diagnostic benefits, exposes patients to higher levels of radiation than conventional periapical and panoramic radiography.