• Title/Summary/Keyword: 방사선 발생장치

Search Result 356, Processing Time 0.029 seconds

Rehabilitation using milled-bar with attachment maxilla overdenture in a patient with peri-implantitis fixed prosthesis: A case report (임플란트 주위염이 발생한 고정성보철 환자에 상악 Milled-bar와 부착장치를 이용한 피개의치로 수복한 증례)

  • Joon-Myung Lee;So-Yeun Kim;Du-Hyeong Lee;Kyu-Bok Lee;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.123-130
    • /
    • 2024
  • There are various methods for restoring the dentition of completely edentulous patients. Removable complete dentures have the advantage of being relatively economical, but they can be uncomfortable to wear. With the introduction of implant prosthodontics, various options such as implant-supported overdentures and hybrid prostheses have become available. If there is inadequate remaining ridge or limited financial resources, an overdenture supported by a few implants with additional attachments may be more suitable. In this case, due to severe peri-implantitis and other complications, the implants were removed. Subsequently, four implants (two on each side) were placed in the maxilla and a milled-bar with attachment was fabricated for each side of the maxilla.

Implementation of Water Bolus in Patient with Large Tissue Defect (조직결손이 큰 환자에서 물 볼루스의 적용에 관한 고찰)

  • Park, Hyo-Kuk;Lee, Sang-Kyu;Yoon, Jong-Won;Cho, Jeong-Hee;Kim, Dong-Wook;Kim, Joo-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.105-112
    • /
    • 2006
  • Purpose: To demonstrate that water bolus in the patient surface can decrease the dose inhomogeneity by patient surface large tissue defect when the surface is in an electron-beam field. And We tried to find a easy way to water control. Methods and Materials: To demonstrate the use of water bolus in the irregular surface clinically, the case of a patient with myxofibrosarcoma of the chest wall who was treated with electrons. We obtained dose distribution using missing tissue option of PINACLE 6.2b (ADAC, USA). We fabricate a Mev-green for water bolus in patient with defect of tissue. Then put the water bolus which is vinyl packed water into the designed Mev-green. We peformed CT scan with CT-simulator. Three-dimensional (3D) dose distributions with and without water bolus in the large irregular chest wall were calculated for a representative patient. Resulting dose distributions and dose-volume histograms of water bolus were compared with missing tissue option and non bolus plans. We fabricate a new water control device. Results: Controlled Water bolus markedly decrease the dose heterogeneity, and minimizes normal tissue exposure caused by the surface irregularities of the chest wall mass. In the test case, The non bolus plan has a maximum target dose of 132%. After applying water bolus, the maximum target dose has been reduced substantially to 110.4%. The maximum target dose was reduced by 21.6% using this technique. Conclusion: The results showed that controlled water bolus could significantly improve the dose homogeneity in the PTV for patients treated with electron therapy using water control device. This technique may reduce the incidence of normal organ complications that occur after electron-beam therapy in irregular surface. And our new device shows handiness of water control.

  • PDF

Adequacy of Source to Image Receptor Distance with Chest Postero-Anterior Projection in Digital Radiology System (디지털방사선 환경에서 흉부 후-전 방향 검사 시 초점과 영상수용체간 거리의 적절성)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;You, In-Gyu;Jung, Hong-Ryang;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.135-142
    • /
    • 2016
  • The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7~3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6~2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6~8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6~8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.

The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy (방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Patient dose verification is one of the most Important responsibilities of the physician in the treatment delivery of radiation therapy. For the task, it is necessary to use an accurate dosimeter that can verify the patient dose profile, and it is also necessary to determine the physical characteristics of beams used in intensity modulated radiation therapy (IMRT) The Beam Intensity Scanner (BInS) System is presented for the dosimetric verification of the two dimensional photon beam. The BInS has a scintillator, made of phosphor Terbium-doped Gadolinium Oxysulphide (Gd$_2$O$_2$S:Tb), to produce fluorescence from the irradiation of photon and electron beams. These fluoroscopic signals are collected and digitized by a digital video camera (DVC) and then processed by custom made software to express the relative dose profile in a 3 dimensional (3D) plot. As an application of the BInS, measurements related to IWRT are made and presented in this work. Using a static multileaf collimator (SMLC) technique, the intensity modulated beam (IMB) is delivered via a sequence of static portals made by controlled leaves. Thus, when static subfields are generated by a sequence of abutting portals, the penumbras and scattered photons of the delivered beams overlap in abutting field regions and this results in the creation of “hot spots”. Using the BInS, inter-step “hot spots” inherent in SMLC are measured and an empirical method to remove them is proposed. Another major MLC technique in IMRT, the dynamic multileaf collimator (DMLC) technique, has different characteristics from SMLC due to a different leaf operation mechanism during the irradiation of photon and electron beams. By using the BInS, the actual delivered doses by SMLC and DMLC techniques are measured and compared. Even if the planned dose to a target volume is equal in our experimental setting, the actual delivered dose by DMLC technique is measured to be larger by 14.8% than that by SMLC, and this is due to scattered photons and contaminant electrons at d$_{max}$.

  • PDF

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

The Study on the Factors for Detection of Renal Stone on Ultrasound (초음파 검사에서 신장 결석의 검출 요인에 관한 연구)

  • Sim, Hyun-Sun;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Purpose: Renal stones are common and typically arise within the collecting system. The renal sinus are contains the collection system, the renal vessels, lymphatcs, fat, and fibrous tissue. Because of the compression of all the large echoes in signal processing, the echo from the renal stone generally cannot be distinguished from large echoes emanating from normal structures of the renal sinus. Use of ultrasonography has been difficult for detecting small renal stone without posterior shadowing and chemical composition of stone. The aim of study was measuring for posterior acoustic shadowing to a stone for various scan parameter and it examines a help in renal stone diagnosis. Material & Methods: The stone was place on sponge examined in a water bath with a 3.5MHz or 7.5MHz transducer(LOGIQ 400, USA). First, tested a variety of gain. Second, tested a variety of dynamic range. Third, tested a variety of focal zone. Fourth, measuring of the echo level for low and high frequency for depth. Results: 1) Average echo level was 98 for low total gain(10 dB) and was 142 for high total gain(40 dB). Posterior acoustic shadowing of renal stone was clear for low gain. 2) Average echo level was 129 for low dynamic range(42 dB) and was 101 for high dynamic range(72 dB). Posterior acoustic shadowing of renal stone was clear for high dynamic range. 3) When stone is in focal zone of transducer, definite posterior acoustic shadow is identified. 4) Stone was clear appeared for high frequency(7.5 MHz) than low frequency(3.5 MHz) and it is not distorted. Conclusion: The demonstration of an posterior acoustic shadow of renal stone dependents on several technical factors such as gain, dynamic range, focus, and frequency. This various factors are a help in renal stone diagnosis.

  • PDF

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.

Dose Change according to Diameter Change of the Cone for Dental X-ray Apparatus (치과구내용 X선발생기의 조사통 직경 변화에 따른 선량변화)

  • Ahn, Sung-Min;Oh, Jung-Hoan;Choi, Jung-Hyun;Shin, Gwi-Soon;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.266-270
    • /
    • 2010
  • In case of the Dental X-ray apparatus, the diameter (or the field size) of the tip of the cone should be less than 7 cm according to the Diagnosis Radiation Equipment Safety Management. However, deviation from the field is not expected to be big as photography is made at close range from the skin. Also, as the size of film or digital detector used in intra-oral photography is $3\times4cm^2$, the size mentioned above can be considered to be much bigger. Furthermore, the patient dose by short-distance photography can not be ignored. Therefore, effect on the patient dose, resolution and image qualty was examined by reducing the cone diameter by 0.5 cm interval. The result showed that the patient dose was reduced and a partial improvement in picture contrast was observed. Therefore, it can be concluded from these results that further investigation may be worthwhile in terms of policy.

Characterization on corrosion damage of nickel alloy for nuclear energy instrument by chemical decontamination solution (원전기기용 니켈합금강의 화학제염용액에 따른 부식손상 특성 규명)

  • Park, Il-Cho;Yang, Ye-Jin;Jeong, Gwang-Hu;Lee, Jeong-Hyeong;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.135-135
    • /
    • 2017
  • 제염기술은 원자력발전소의 순환계통장치 및 기기류의 방사성 오염물질을 제거하는 기술이다. 현재 국내 원전의 설계 수명 및 유지보수 시기가 도래함에 따라, 작업 전 작업자의 방사선 피사량을 극소화하기 위한 제염 기술이 주목을 받고 있다. 제염 방법에는 크게 기계적 제염과 화학약품을 사용하는 화학제염이 있다. 그 중 화학제염은 복잡한 구조의 제염 대상물에 대한 큰 효과 및 간단한 공정 때문에 주로 사용되고 있다. 제염 시 방사성 산화물과 오염성분을 제거하기 위해 강산 또는 강알칼리의 화학용액이 사용된다. 강한 화학약품을 사용함으로써 큰 제염효과를 얻을 수 있는 반면, 금속 재료의 부식에 대한 구동력도 커지게 된다. 금속 재료의 경우, 강한 부식성 환경에서 공식(pitting corrosion) 및 입계부식(intergranular corrosion)형태의 손상이 크게 발생하기 때문에, 제염공정 시 사용되는 화학용액에 대한 재료의 건전성 검증이 반드시 필요하다. 본 연구에서는 원전기기용 재료인 니켈합금강 Inconel600의 화학제염 시 시험공정 3가지에 대한 부식손상 특성을 규명하였다. 산화공정은 $HMnO_4$ 실험용액을 공통으로 사용하였으며, 산화공정 종료 후 환원공정은 각 시험공정에 따라 환원공정 1은 2000ppm $H_2C_2O_4$, 환원공정 2는 1500ppm $H_2C_2O_4$ + 500ppm $H_8C_6O_7$, 그리고 환원공정 3은 3000ppm $H_2C_2O_4$ 실험용액을 각각 투입하여 수행하였다. 산화, 환원공정을 1Cycle로 하여 온도 $75^{\circ}C$로 유지된 용액에 각 2시간씩 침적하였다. 각 시험공정 별로 총 5Cycle을 실시하였다. 각 시험공정 Cycle종료 후 시험편을 취외하여 무게감량측정, SEM(Scanning electron microscope)분석, 3D현미경분석 그리고 타펠분극 실험을 실시하였다. 각 분석결과를 토대로 하여, 니켈합금 Inconel600에 대한 화학제염 시 시험공정에 따른 부식특성을 규명하였다.

  • PDF

Lung Lobe Torsion with Concurrent Intestinal Lymphangiectasia in a Maltese Dog (Maltese 개에서 림프관 확장증을 동반한 폐염전 발생 증례)

  • Yoon, Hun-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.28 no.2
    • /
    • pp.262-266
    • /
    • 2011
  • A 4-year-old intact male, Maltese dog weighing 2.2 kg was presented for evaluation of tachypnea and hyperthermia. On initial evaluation, the dog was dyspneic, but alert and responsive. Muffled heart sound was noted with auscultation of the right hemithorax. The radiographic findings were consolidation of the right middle lung lobe, pleural effusion, and abdominal fluid accumulation. Thoracic computed tomography confirmed a contrast-enhancing mass within the right middle lung lobe. Surgical exploration of the thoracic cavity was performed using a right fifth intercostal thoracotomy. Examination of the right lung lobe revealed $360^{\circ}C$ torsion of the right middle lung lobe at the level of the hilus, in a clockwise direction. Lung lobectomy was performed using a thoracoabdominal stapling device with 2.5-mm vascular staples. Full-thickness intestinal biopsy by exploratory laparotomy was taken from the jejunum for histological assessment. Histopathologic examination of the full-thickness intestinal biopsy revealed distended lacteal located within the submucosa of the jejunum. Intestinal lymphangiectasia was resolved with prednisone and low fat diets. Subsequent communication with the owner revealed that the patient was in good health 6 months post-discharge.