A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

Response Analysis of the NE213-PSD System for Neutron Energy Spectreum Measurement (중성자 에너지 측정을 위한 NE213-PSD 장치의 감응 분석)

  • Lee, Kyung-Ju
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.367-372
    • /
    • 1992
  • In order to measure the energy spectrum of a radioactive neutron source, the pulse shape discrimination (PSD) system with organic scintillator, NE-213, was characterized by using some of the gamma ray sources and neutron source, Am-Be. The figure of merit of the rise time spectrum of AmBe source measured by this system was about 1.13. This value agrees well with the value of 1.3 which is measured for monoenergetic source, $^{12}C(d,\;n)^{13}N$. The results of present experiment for performance test of NE213-PSD system will provide the useful technique to measure the spectrum of neutron-gamma mixed field and to establish the neutron energy spectrum and flux density standards.

  • PDF

Calibration of CR-39 for Measurement of Radon in Air (공기중의 라돈 농도 측정을 위한 CR-39의 교정)

  • Park, Y.W.;Chang, S.Y.;Ha, C.W.;Ro, S.G.
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.18-22
    • /
    • 1989
  • In order to calibrate the CR-39 Solid State Nuclear Track Detector (SSNTD), a closed -circulation type SSNTD-Calibration-System containing a radon-cup with the Millipore filter has been set-up, and the tracks produced on the SSNTD were measured for the known amount of radon concentration. Calibration factor for the time integrated radon concentration as a function of the track density on CR-39 was estimated to be $0.24{\pm}0.09(pCi/l)\;day/(Tr/cm^2)$.

  • PDF

Radiation Degradation Detection of LDPE Using Thermoluminescence Method (열발광 특성을 이용한 저밀도 폴리에틸렌의 방사선 열화 검출)

  • Lee, C.;Lee, K.W.;Park, J.N.;Lim, K.J.;Ryu, B.H.;Park, Y.G.;Kang, S.H.;Kim, K.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.43-46
    • /
    • 2001
  • Polymers are widely used as insulating materials at various part of power industry. However, electrical properties of these polymers are easily degraded with their working environments, especially radiation areas. In this research, radiation degradation of low density polyethylene (LDPE) used as cable insulation was evaluated with thermoluminescence characteristics. LDPE was irradiated with gamma ray up to 1000 kGy at a dose rate of 5 kGy/hr in the presence of air at room temperature. Each of the irradiated samples were carried out thermoluminescence analysis as a function of temperature. Interrelationships between thermoluminescence and dielectric characteristics and volume resistivity are investigated as well. The results of thermoluminescence analysis showed that those would be significant factors for evaluation of radiation degradation.

  • PDF

옥수수 전분 추출공정 및 물성개선을 위한 방사선의 이용연구

  • 강일준;이수정
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 1994.07a
    • /
    • pp.15-16
    • /
    • 1994
  • 옥수수 전분의 추출공정 개선 연구의 일환으로 메 밀 찰옥수수에 0-10 kGy범위의 감마선을 조사한 후 전분 추출시험과 추출전분의 이화학적 특성을 펴가하였다. 적정선량 범위의 감마선조사는 전분추출을 위한 침지시간을 기존 50시간에서 40시간으로 단축 시킬 수 있었으며, 환경기준 물질인 옥수수침지액(아황산용액)의 농도를 기존 0.8-1.2% 에서 0.2%로 크게 감소시킬 수 있었다. 또한 옥수수전분 추출액에 있어서 감마선 조사된 메옥수수와 찰옥수수는 비조사군에 비해 10-30% 이상의 추출율 증대효과를 나타내었다. 추 전분의 이화학적 특성시험에있어서는 두 시료 모두 감마선조사에 의해 alkaili number와 광투과도가 크게 증가 하였으며, 물 결합능력 및 swelling power는 다소 감소하는 경향이었다.전분의 색도는 조사군과 비조사군 사이에 유의적인 차이가 없었다. 효소반응 시험에서는 감마선 조사량이 증가함에 따라 효소반응 생성물인 포도당과 환원당 함량이 크게 증가하였다. Amylograph에 의한 물성시험에서는 감마선조사에 의해 전분호화액의 점도는 감소되었고, 그 경향은 메옥수수보다 찰옥수수에서 더욱 현저하였다. 또한 감마선의 이용은 옥수수 전분의 breakdown ratio 및 setback ratio를 향상시킬 수 있어 식품가공에서 전분의 고존도 사입 가능성을 시사하였다. 시사하였다.

  • PDF

Evaluation of MTF Image by Target/Filter Combined of X-ray Tube Using Mammography (유방촬영용 X선관 target/filter 조합에 따른 MTF영상평가에 관한 고찰)

  • Yang, Han-Jun;Joo, Mi-Hwa;Ko, Sin-Kwan
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.113-119
    • /
    • 2007
  • It is important to consider the contrast of object in Mammography because an absorption gap between tissues of body and breast in breast is low. This study is to evaluate MTF image with resolution chart according to change of combination of target and filter. The results were as follows : 1. There were significant differences in X-ray energy according to combination of filter(Mo/Mo, Mo/Rh. Mo/Al, Rh/Rh, Rh/Al) and acrylic thickness(2 cm, 3 cm, 4 cm). 2. The value of lp/mm on MTF to 0.5 showed that the sharpness in MTF curve was 2.4 compared to Mo/Mo and 2cm acryl, 2.63 in Mo/Rh and 4 cm acryl, and 2.9 in Rh/Rh and 6cm acryl. 3. The value of lp/mm on MTF showed that the resolution in MTF curve was 6.0 compared to Mo/Mo and 2 cm acryl, 4.60 in Rh/Al and 4cm acryl, and 6.03 in Rh/Al and 6 cm acryl. 4. The value of MTF on 2.5 lp/mm distinguishable visually was 0.48 compared to Mo/Mo and 2 cm acryl, 0.53 in Mo/Rh and 4cm acryl, and 0.59 in Rh/Rh and 6cm acryl. 5. For the evaluation of an image of the mammo-phantom, the score of Mo/Mo was 12 points, Mo/Rh 11, Rh/Rh 10.5, Mo/Al 10, Rh/Al 9.0, respectively.

  • PDF

A Study on Improvement of Image Quality Decrease due to Tooth Restoration in Facial CT (안면부 CT 검사 시 치아 충전물에 의한 화질 저하 개선 방안에 관한 연구)

  • Kim, Hyeon ju;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.497-503
    • /
    • 2018
  • The purpose of this study was to investigate the degree of image degradation and the improvement of image quality caused by the density difference between the orthodontic filling material and the surrounding anatomical structure during the examination of the facial CT by quantitative and qualitative analysis. The teeth were scanned using 64-MDCT (Discovery 750 HD, GE HEALTH CARE, Milwaukee, USA). The teeth were scanned and compared according to tube voltage, silicone application, and MAR application. As a result, 10.36% CT value decreased at 140 kVp and 5.81% decrease at the application of silicon material. As a result of the qualitative evaluation, it was evaluated that 7 of the 10 observers and 3 of the acceptors were applied to the MAR algorithm. Therefore, it is possible to reduce the unnecessary burden on the radiation exposure dose as well as to reduce the loss of image data by reducing the high density artifacts, as well as the inspection parameters used in the current clinical application and various algorithms that can reduce the high density artifacts. It can be expected to provide a lot of image information.

A Study on the Analysis of Risk Factors and Correlations of Coronary Artery Disease of the Examinee taking Coronary Computed Tomography Angiography in a Comprehensive Health Improvement Center (종합검진 수검자의 관상동맥 전산화단층 혈관조영술 검사에서 관상동맥질환의 위험요인과 관련성 분석)

  • Choi, Min-Gyeong;Gwak, Jong-Hyeok;Kim, Gwang;Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1005-1014
    • /
    • 2019
  • The purpose of this study is to evaluate the usefulness of coronary computed tomography angiography of coronary artery disease for the purpose fo health screening according to gender and age. In addition the association between hematological factors (Glucose, total cholesterol, visceral fat, body mass index, triglycerides, high density lipoprotein (HDL), low density lipoprotein (LDL)) and coronary artery disease is investigated. A retrospective analysis of coronary computed tomography angiography with 299 subjects showed that the detection rate of coronary artery disease was higher in men over 50 years of age and it was statistically significant. In particular, the prevalence rate of men (37.9%) was about 2 times higher than that of women (17.0%). Glucose and HDL as hematological factors associated with coronary artery disease were statistically significant. The prevention and management of coronary artery disease seems to require the control of glucose and high density lipoprotein (HDL). Although it is not statistically significant with other hematological factors, the need for management of coronary artery disease was identified. the coronary computed tomography angiography of coronary artery has higher radiation doses than other CT scans. Therefore, for the purpose of screening, coronary computed tomography angiography should be considered in consideration of the sex and age of the examinee, and detection of coronary artery disease through other non-invasive tests should be prioritized over coronary computed tomography angiography.

Estimation of Computed Tomography Dose in Various Phantom Shapes and Compositions (다양한 팬텀 모양 및 재질에 따른 전산화단층촬영장치 선량 평가)

  • Lee, Chang-Lae
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • The purpose of this study was to investigate CTDI (computed tomography dose index at center) for various phantom shapes, sizes, and compositions by using GATE (geant4 application for tomographic emission) simulations. GATE simulations were performed for various phantom shapes (cylinder, elliptical, and hexagonal prism PMMA phantoms) and phantom compositions (water, PMMA, polyethylene, polyoxymethylene) with various diameters (1-50 cm) at various kVp and mAs levels. The $CTDI_{100center}$ values of cylinder, elliptical, and hexagonal prism phantom at 120 kVp, 200 mAs resulted in 11.1, 13.4, and 12.2 mGy, respectively. The volume is the same, but $CTDI_{100center}$ values are different depending on the type of phantom. The water, PMMA, and polyoxymethylene phantom $CTDI_{100center}$ values were relatively low as the material density increased. However, in the case of Polyethylene, the $CTDI_{100center}$ value was higher than that of PMMA at diameters exceeding 15 cm ($CTDI_{100center}$ : 35.0 mGy). And a diameter greater than 30 cm ($CTDI_{100center}$ : 17.7 mGy) showed more $CTDI_{100center}$ than Water. We have used limited phantoms to evaluate CT doses. In this study, $CTDI_{100center}$ values were estimated and simulated by GATE simulation according to the material and shape of the phantom. CT dosimetry can be estimated more accurately by using various materials and phantom shapes close to human body.

Comparison of Hounsfield Units by Changing in Size of Physical Area and Setting Size o f Region o f Interest b y Using the CT Phantom Made with a 3D Printer (3D 프린터로 제작된 CT 팬톰을 이용한 물리적 관심영역과 설정 관심영역의 크기에 따른 하운스필드의 비교)

  • Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.421-427
    • /
    • 2015
  • In this study, we have observed the change of the Hounsfield (HU) in the alteration of by changing in size of physical area and setting size of region of interest (ROI) at focus on kVp and mAs. Four-channel multi-detector computed tomography was used to get transverse axial scanning images and HU. Three dimensional printer which is type of fused deposition modeling (FDM) was used to produce the Phantom. The structure of the phantom was designed to be a type of cylinder that contains 33 mm, 24 mm, 19 mm, 16 mm, 9 mm size of circle holes that are symmetrically located. It was charged with mixing iodine contrast agent and distilled water in the holes. The images were gained with changing by 90 kVp, 120 kVp, 140 kVp and 50 mAs, 100 mAs, 150 mAs, respectively. The 'image J' was used to get the HU measurement of gained images of ROI. As a result, it was confirmed that kVp affects to HU more than mAs. And it is suggested that the smaller size of physical area, the more decreasing HU even in material of a uniform density and the smaller setting size of ROI, the more increasing HU. Therefore, it is reason that to set maximum ROI within 5 HU is the best way to minimize in the alteration of by changing in size of physical area and setting size of region of interest.