• Title/Summary/Keyword: 방사선 밀도

Search Result 280, Processing Time 0.024 seconds

Dose distribution at junctional area abutting X-ray and electron fields (X-선과 전자선의 인접조사에서 접합 조사면에서의 선량분포)

  • Yang, Kwang-Mo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.91-99
    • /
    • 2004
  • Purpose : For the head and neck radiotherapy, abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Materials and methods : Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom according to depths(0 cm, 1.5 cm, 3 cm, 5 cm). 6 MV X-ray and 9 MeV electron(1Gy) were exposes to 8cm depth and surface(SSD 100cm) of phantom. The dose distribution to the junction line between photon($10cm{\times}10cm$ field with block) and electron($15cm{\times}15cm$ field with block) fields was also measured according to depths(0 cm, 0.5 1.5 cm, 3 cm, 5 cm). Results : At the junction line between photon and electron fields, the hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to $6\%$ of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was $4.5-30\%$ of reference dose in the electron field. Conclusion : When we make use of abutting photon field with electron field for the treatment of head and neck cancer we should consider the hot and cold dose area in the junction of photon and electron field according to location of tumor.

  • PDF

Decontamination of simulated radioactive metal waste by modified electrolytic Process with neutral salt electrolytes (개선된 중성염 진해공정을 이용한 모의 방사성 금속폐기물의 제염)

  • Lee, Ji-Hoon;Yuk, Wan-Yi;Yang, Ho-Yeon;Ha, Jong-Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.2
    • /
    • pp.95-100
    • /
    • 2002
  • Conventional and modified electrolytic decontamination experiment were performed in the 1.7 M solution of sodium sulfate and sodium nitrate tot decontamination of carbon steel as the simulated metal wastes which have been produced in large amounts from nuclear power plants. Anode ant cathode were used as inconel and titanium respective. The reaction time and temperature were 1 hr and $25^{\circ}C$ The analyses were performed of the characteristics such as weight loss arid thickness change of metal waste. suspended solid in electrolyte and SEM observation. In modified electrolyte decontamination system with increased current density ranged from 0.1 to $0.6A/cm^2$, the metal waste showed thickness changes of $0.48{\pm}0.005$ to $67.7{\pm}0.02{\mu}m$ in 1.7 M sodium sulfate and those of $0.06{\pm}0.005$ to $17.7{\pm}0.05{\mu}m$ in sodium nitrate. Metal waste in modified electrolyte decontamination system showed the thickness change of $9.8{\pm}0.01{\mu}m$ while it reacted up to $3.7{\pm}0.03{\mu}m$ in conventional system with $0.3 A/cm^2$ of current density and 1.7 M sodium sulfate. Decontamination efficiencies of modified electrolytic process ate much hither than that of conventional electrolytic process when both are applied to metal waste.

Measurement Method of Final Residual Radioactivity of Radioactive Metallic Waste for Clearance (규제해제 대상 방사성 금속 폐기물 최종잔류방사능 측정법)

  • Seo, Bumkyoung;Ji, Youngyong;Hong, Sangbum;Lee, Keunwoo;Moon, Jeikwon
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.228-233
    • /
    • 2013
  • It has been continuously generated the requirement for the replacement of the main components such as a steam generator due to the deterioration of the nuclear power plant all around the world. Also, a large amount of radioactive metal was generated during the decommissioning in a short period. It is required to make an accurate measurement of the residual radioactivity for recycling the metal waste for releasing from regulatory control. In planning the measurement procedures, the influence of geometry, self-absorption, density and other relevant factors on the representativeness of the measurements should be considered for the decommissioning metal waste. In this study, the method for measurement procedures, the source term evaluation, the ways to secure representative samples, the measurement device for wide area and the self-absorption correction factors for different density were evaluated. The metal samples for measurement were prepared for securing the simple geometry and representative by melting process. The developed correction method for measuring the radioactivity a variety density of metal waste could improve the reliability of the evaluation results for clearance.

The Application of 3D Bolus with Neck in the Treatment of Hypopharynx Cancer in VMAT (Hypopharynx Cancer의 VMAT 치료 시 Neck 3D Bolus 적용에 대한 유용성 평가)

  • An, Ye Chan;Kim, Jin Man;Kim, Chan Yang;Kim, Jong Sik;Park, Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.41-52
    • /
    • 2020
  • Purpose: To find out the dosimetric usefulness, setup reproducibility and efficiency of applying 3D Bolus by comparing two treatment plans in which Commercial Bolus and 3D Bolus produced by 3D Printing Technology were applied to the neck during VMAT treatment of Hypopahrynx Cancer to evaluate the clinical applicability. Materials and Methods: Based on the CT image of the RANDO phantom to which CB was applied, 3D Bolus were fabricated in the same form. 3D Bolus was printed with a polyurethane acrylate resin with a density of 1.2g/㎤ through the SLA technique using OMG SLA 660 Printer and MaterializeMagics software. Based on two CT images using CB and 3D Bolus, a treatment plan was established assuming VMAT treatment of Hypopharynx Cancer. CBCT images were obtained for each of the two established treatment plans 18 times, and the treatment efficiency was evaluated by measuring the setup time each time. Based on the obtained CBCT image, the adaptive plan was performed through Pinnacle, a computerized treatment planning system, to evaluate target, normal organ dose evaluation, and changes in bolus volume. Results: The setup time for each treatment plan was reduced by an average of 28 sec in the 3D Bolus treatment plan compared to the CB treatment plan. The Bolus Volume change during the pretreatment period was 86.1±2.70㎤ in 83.9㎤ of CB Initial Plan and 99.8±0.46㎤ in 92.2㎤ of 3D Bolus Initial Plan. The change in CTV Min Value was 167.4±19.38cGy in CB Initial Plan 191.6cGy and 149.5±18.27cGy in 3D Bolus Initial Plan 167.3cGy. The change in CTV Mean Value was 228.3±0.38cGy in CB Initial Plan 227.1cGy and 227.7±0.30cGy in 3D Bolus Initial Plan 225.9cGy. The change in PTV Min Value was 74.9±19.47cGy in CB Initial Plan 128.5cGy and 83.2±12.92cGy in 3D Bolus Initial Plan 139.9cGy. The change in PTV Mean Value was 226.2±0.83cGy in CB Initial Plan 225.4cGy and 225.8±0.33cGy in 3D Bolus Initial Plan 224.1cGy. The maximum value for the normal organ spinal cord was the same as 135.6cGy on average each time. Conclusion: From the experimental results of this paper, it was found that the application of 3D Bolus to the irregular body surface is more dosimetrically useful than the application of Commercial Bolus, and the setup reproducibility and efficiency are excellent. If further case studies along with research on the diversity of 3D printing materials are conducted in the future, the application of 3D Bolus in the field of radiation therapy is expected to proceed more actively.

Dose Alterations at the Distal Surface by Tissue Inhomogeneity in High Energy Photon Beam (조직 불균질성에 의한 고에너지 광자선의 선량변화)

  • Kim, Young-Ai;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.277-283
    • /
    • 1995
  • Purpose : This study was performed to measure dose alteration at the air-tissue interface resulting from rebuild-up to the loss of charged particle equilibrium in the tissues around the air-tissue interfaces. Materials and Methods : The 6 and 10-MV photon beam in dual energy linear accelerator were used to measure the surface dose at the air-tissue interface The polystyrene phantom sized $25{\times}25{\times}5\;cm^3$ and a water phantom sized $29{\times}29{\times}48\;cm^3$ which incorporates a parallel-plate ionization chamber in the distal side of air gap were used in this study. The treatment field sizes were $5{\times}5\;cm^2,\;10{\times}10\;cm^2\;and\;20{\times}20\;cm^2$. Air cavity thickness was variable from 10 mm to 50 mm. The observed-expected ratio (OER) was defined as the ratio of dose measured at the distal junction that is air-tissue interface to the dose measured at the same point in a homogeneous phantom. Results : In this experiment, the result of OER was close or slightly over than 1.0 for the large field size but much less (about 0.565) than 1.0 for the small field size in both photon energy. The factors to affect the dose distribution at the air-tissue interface were the field size, the thickness of air cavity. and the photon energy. Conclusion : Thus, the radiation oncologist should take into account dose reduction at the air-tissue interface when planning the head and neck cancer especially pharynx and laryngeal lesions, because the dose can be less nearly $29{\%}$ than predicted value.

  • PDF

A Study on the DWI and Pathologic Findings of Cancer Cells (암 세포주의 확산강조영상과 병리학적 관계에 관한 연구)

  • Seong, Jae-Gu;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.239-244
    • /
    • 2011
  • In this study, we evaluated diffusion weighted imaging (DWI) to investigate whether the DWI parameters can predict characteristic parameters on pathologic specimens of tumor or not. CFPAC-1 was injected subcutaneously on the back flank of athymic nude mice (n=13) then two tumors were initiated on each mouse (2${\times}$13=26 tumors). The mice were sacrificed to make specimen immediately after initial MR imaging then were compared with the MR image. A dedicated high-field (7T) small-animal MR scanner was used for image acquisitions. A T1 and T2 weighted axial image using RARE technique was acquired to measure the T2 values and tumor size. DWI MR was performed for calculating ADC values. To evaluate tumor cellularity and determine the levels of MVD, tumor cells were excised and processed for H-E staining and immunostaining using CD31. T2 values and ADC values were computed and analyzed for each half of the tumors and compared to the correlated specimens slide. Median ADC within each half of mass was compared to the cellularity and MVD in the correlated area of pathologic slide. The mean of ADC value is $0.7327{\times}10^{-3}$ $mm^2/s$ and standard deviation is $0.1075{\times}10^{-3}$ $mm^2/s$. There is a linear relationship between ADC value and tumor necrosis (R2=0.697, p< 0.001). DW image parameters including the ADC values can be utilized as surrogate markers to assess intratumoral neoangiogenesis and change of the internal structure of tumor cells.

Effects of Use of the Iodine Contrast Medium on Gamma Camera Imaging (요오드 조영제 사용이 감마카메라 영상에 미치는 영향)

  • Pyo, Sung-Jae;Cho, Yun-Ho;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.557-564
    • /
    • 2016
  • Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficient in an SPECT/CT attenuation correction will be considered herein. For experimental materials used $^{99m}TcO_4$ 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of $^{99m}TcO_4$. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope $^{99m}TcO_4$ and the saline solution were mixed. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and saline solution, the mean counting rate without correction by the CT absorption coefficient is $182{\pm}26counts$, while the counting rate with correction by the CT absorption coefficient is $531.3{\pm}34counts$. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were $166{\pm}29$, $158.3{\pm}17$, $154{\pm}36$, and $150{\pm}33counts$ depending on the densities of the contrast medium, while the mean values after attenuation correction were $515{\pm}03$, $503{\pm}10$, $496{\pm}31$, and $488.7{\pm}33counts$, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of dignosis.

Correlation between Carotid Intima-media Thickness and Risk Factors for Atherosclerosis (경동맥 내중막 두께에 따른 죽상경화반의 위험요인과의 상관관계)

  • An, Hyun;Lee, Hyo Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.339-348
    • /
    • 2019
  • The purpose of this study was to investigate the effect of carotid artery ultrasound Respectively. The carotid intima-media thickness is known to have a significant correlation with cardiovascular disease and cerebrovascular disease. We investigated the relationship between carotid intima - media thickness, body mass index, waist circumference, the blood lipid value, fasting blood glucose, glycated hemoglobin, and blood pressure using carotid artery ultrasound. The carotid artery ultrasound was considered to be abnormality of IMT thickness over 0.8 mm and the presence or absence of atherosclerotic plaque was evaluated. Serological tests were used to compare the geologic value, fasting blood glucose level, and glycated hemoglobin. As a result, waist circumference (=.022), low density cholesterol (=.004), fasting blood glucose level (.019), and glycemic index (.002) were analyzed as predictors of atherosclerosis. In the ROC curve analysis, sensitivity was 87.80% (95% CI: 73.8-95.9), specificity was 41.67% (95% CI: 30.2-53.9), sensitivity was 78.05% (95% CI: 62.4-89.4) in low density lipoprotein, Specificity was 50.00% (95% CI: 38.0-62.0), sensitivity was 73.11% (95% CI: 57.1-85.8), specificity was 61.11 (95% CI: 48.9-72.4) and sensitivity was 82.93%-91.8) and a specificity of 43.06% (31.4-55.3). In logistic regression analysis, the risk of atherosclerosis was 0.248 times at waist circumference (WC)> 76 cm, 3.475 times at low-density lipoprotein (LDL-C) ${\geq}124mg/dL$, 0.618 at HbA1c> 5.4% It appeared as a times. We suggest that prospective study of carotid artery ultrasound should be performed for the effective prevention of cardiovascular diseases.

A Study on the Correlations between Total Prostate Volume and Prostate Transition Zone Volume Assessed Using Blood and Ultrasound Tests: in the Healthy Korean Men in Thirties (혈액, 초음파 검사 결과를 이용한 전립선이행대용적의 상관관계 연구: 기초질환이 없는 30대를 대상으로)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.407-412
    • /
    • 2017
  • This study investigates the correlations between the total prostate volume (TPV), using the prostate specific antigen (PSA) and prostate specific antigen density (PSAD) as the blood test results and transrectal ultrasound (TRUS), and the prostate transition zone volume (PTZV), as well as variables such as age; the findings can be used as clinical indicators. A retrospective analysis was conducted on 68 healthy men in their 30s who underwent TRUS and PSA and PSAD blood tests from June 2007 to April 2016, with no history of treatment in their prostate. Siemens Acuson sequoia 512 and the probe Siemens EC-10C5 Endocavitary were used as the ultrasound equipment. For statistical analysis, SPSS 18.0 was used to calculate the standard deviation and mean of each variable; Pearson's correlation analysis was also performed. The descriptive statistics of the variables were $24.27{\pm}6.60$ for TPV, $6.99{\pm}6.60$ for PTZV, $2.12{\pm}2.76$ for PSA, and $0.281{\pm}0.1$ for PSAD. The coefficients of correlations between PTZV and variables were 0.831 for PSAD, 0.707 for TPV, 0.398 for age, and 0.118 for PSA. While PSA and age were positively correlated, PSAD and TPV were highly correlated. Therefore, PTZV of men in their 30s without underlying diseases can be predicted using PSAD and TPV.

Determination of Personnel Exposures in the Lower Energy Ranges of X-Ray by Photographic Dosimeter (저(低)에너지 X-선장(線場)에서 필름배지에 의한 개인피폭선량(個人被曝線量)의 결정(決定))

  • Ha, C.W.;Kim, J.R.;Suh, K.W.
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.57-64
    • /
    • 1986
  • This paper described an improved technical method required for proper evaluation of personnel exposures by means of the photographic dosimeter developed by KAERI in lower gamma or X-ray energy regions, with which response of the dosimeter varies significantly. With calibration of the dosimeter in the energy range from 30 to 300 keV, the beam spectrum was carefully selected and specified it adequately. The absorber combinations and absorber thickness used to obtain the specified X-ray spectra from a constant potential X-ray machine were determined theoretically and also experimentally. A correlation between the density and exposure for the four separate energies, such as $49\;keV_{eff},\;154\;keV_{eff}\;250\;keV_{eff}\;and\;662\;keV$, is experimentally determined. As a result, it can be directly evaluated the exposure from the measured response of dosimeter.

  • PDF