• Title/Summary/Keyword: 방사선 과피폭

Search Result 368, Processing Time 0.024 seconds

Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study (급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구)

  • Park, Ha-Young;Pyeon, Do-Yeong;Kim, Da-Hye;Jung, Young-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Acute stroke is a one of common disease that require fast diagnosis and treatment to save patients life. however, the acute stroke may cause lifelong disability due to brain damage with no prompt surgical procedure. In order to diagnose the Stroke, brain perfusion CT examination and possible rapid implementation of 3D angiography has been widely used. However, a low-dose technique should be applied for the examination since a lot of radiation exposure to the patient may cause secondary damage for the patients. Therefore, the degradation of the measured CT images may interferes with a clinical check in that blood vessel shapes on the CT image are significantly affected by gaussian noise. In this study, we employed the spatio-temporal technique to analyze dynamic (brain perfusion) CT data to improve an image quality for successful clinical diagnosis. As a results, proposed technique could remove gaussian noise successfully, demonstrated a possibility of new image segmentation technique for CT angiography. Qualitative evaluation was conducted by skilled radiological technologists, indicated significant quality improvement of dynamic CT images. the proposed technique will be useful tools as a clinical application for brain perfusion CT examination.

Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult (진단X선에 의한 성인의 진단행위별 유효선량평가)

  • Kim, Woo-Ran;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.155-164
    • /
    • 2002
  • Methodology to evaluate the effective doses to adults undergoing various diagnostic x-ray examinations were established by Monte Carlo simulation of the x-ray examinations. Anthropomorphic mathematical phantoms, the MIRD5 male phantom and the ORNL female phantom, were used as the target body and x-ray spectra were produced by the x-ray spectrum generation code SPEC78. The computational procedure was validated by comparing the resulting doses to the results of NRPB studies for the same diagnostic procedures. The effective doses as well as the organ doses due to chest, abdomen, head and spine examinations were calculated for x-rays incident from AP, PA, LLAT and RLAT directions. For instance, the effective doses from the most common procedures, chest PA and abdomen AP, were 0.029 mSv and 0.44 mSv, respectively. The fact that the effective dose from PA chest x-ray is far lower than the traditional value of 0.3 mSv(or 30 mrem), which results partly from the advances of technology in diagnostic radiology and partly from the differences in the dose concept employed, emphasizes necessities of intensive assessment of the patient doses in wide ranges of medical exposures. The methodology and tools established in this study can easily be applied to dose assessments for other radiology procedures; dose from CT examinations, dose to the fetus due to examinations of pregnant women, dose from pediatric radiology.

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF

Study on the Assessment of Dose Equivalent due to the Inhalation of $^{222}Rn$ and Its Daughters in Indoor Air (실내 $^{222}Rn$$^{222}Rn$ 딸핵종에 의한 피폭선량 해석연구)

  • Jun, Jae-Shik;Chai, Ha-Seok;Yi, Chul-Young;Cho, Hyuck;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.16-24
    • /
    • 1995
  • Assesment of dose equivalent given by inhaled $^{222}Rn$ and its progeny has been carried out based on the concentrations of $^{222}Rn$ and its daughters in indoor air, and equilibrium factor between them measured by charcoal canister method and alpha spectrometry. Assuming the occupancy factor to be 0.8, and breathing rate to be $0.75m^3\;h^{-1}$ for public and $1.2m^3\;h^{-1}$ for occupational exposure, respectively, the regional lung dose 대valent and the resulting annual effective dose equivalent due to the inhalation of $^{222}Rn$ and its daughters in indoor air were evaluated by use of three different lung models, namely, Jacobi-Eisfeld, James-Birchall and ICRP model.

  • PDF

A Study on the Assessment of Derived Intervention Levels in Foodstuffs Using the Dynamic Ingestion Pathway Model (동적 섭식경로모델을 이용한 음식물에 대한 유도 방사능 개입준위의 산정에 관한 연구)

  • Hwang, Won-Tae;Han, Moon-Hee;Kim, Byung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.3
    • /
    • pp.199-208
    • /
    • 1994
  • The derived intervention levels in Korean foodstuffs were estimated using the dynamic ingestion pathway model which was developed considering Korean environment. The derived intervention levels were estimated from the intervention level of dose based on the thyroid committed dose equivalent of infant in the case of I-131, and the whole body committed dose equivalent for age groups and 13 kinds foodstuffs in the cases of Cs-137 and Sr-90. The derived intervention levels were shown as a considerable variation with deposition time and radionuclide. The adult was the most important age group in the estimation of derived intervention levels for Cs-137 and Sr-90. In the adult, the derived intervention levels for rice were 2390 and 47 Bq/kg for Cs-137 and Sr-90 in the case of deposition in summer, respectively, and 198 and 79 Bq/kg in the case of deposition in winter, respectively.

  • PDF

Comparative Study on the Committed Dose Equivalent for Adults and Infants (예탁선양치(預託線量値)에서 본 성인(成人)과 유아(幼兒)와의 비교연구(比較硏究))

  • Sung, Kye-Yong;Yook, Chong-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.76-89
    • /
    • 1984
  • Weighted committed dose equivalents($W_T\;H_{50}$) per intake of unit activity of four nuclides-I-131, I-133, Cs-134 and Cs-137-, which was based on the concepts of ICRP Pub. 30, are calculated for adult who is 70 kg and 25 years old and, for infant who is 10 kg and 1 year old. Metabolism of iodine taken through oral or inhalation pathway is described by using the three-compartment model which consists of inorganic, thyroid and organic compartment. After intake, the amount of iodine in every compartment is calculated by solving the transfer equations among the these compartments. As soon as caesium is taken into the body, it is distributed uniformly in the body through the transfer compartment. In this case, the amount of caesium in total body is calculated by using the total body compartment model which is divided into two tissue compartments because of their different biological half-lifes of caesium in body. As a result of calculations, whether oral or inhalation pathway, the values of ($W_T\;H_{50}$) per intake of unit activity of I-131 for infants are about ten times as much as those of adults. On the other hand, for Cs-134 and Cs-137, the values of $W_T\;H_{50}$ per intake of unit activity show that, whether adults of infants, they have almost the same values.

  • PDF

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

A Consideration of Perception on Enforcement of Serious Accident Punishment Act(SAPA) among the Workers in the Nuclear Medicine Department (중대재해처벌법 시행에 따른 핵의학 종사자의 인식 고찰)

  • Lee, Joo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.477-490
    • /
    • 2022
  • Serious Accident Punishment Act(SAPA) went into effect as of Jan. 27, 2022. The subject of study was the worker of the nuclear medicine department and the investigation was aimed at identifying the present situation of their understanding on the issue in the here and now, which can be utilized as basic research for further study. The survey was conducted on 51 people of the worker in the nuclear medicine department. The general factors were classified by their gender, the scale of the hospitals, the period of career, and the detailed occupational categories. The conclusion was drawn, including 1 missing data in gender and 2 in the type of occupation. The targeted hospitals were tertiary hospital, university hospital, and general hospital which have nuclear medicine department in. The period of subjects' career was categorized by less than 3 years, 3 to 5 years, 5 to 10 years, and more than 10 years. The specific occupation was classified by in-vivo radiological technologist, radiation safety manager and others. The amount of pressure that the job entails was highest in the category of general hospital, the period of 3 to 5 years of job experience, and radiation safety manager each. The system of the code was well constructed in the category of general hospital, the period of less than 3-year career, and radiation safety manager, as they responded. The blood transmissible disease had the largest number of outbreak of accidents related to the serious industrial accident. In addition, the radiopharmaceutical dosing error had the highest number of outbreak of accidents related to the serious civil accident. Therefore, we need to improve SAPA, facility inspection, security of budget, security of professional manpower. It will help the stable use of radiation and ensure patient safety.

Development of the Monte Carlo Simulation Radiation Dose Assessment Procedure for NORM added Consumer Adhere·Non-Adhere Product based on ICRP 103 (ICRP 103 권고기반의 밀착형·비밀착형 가공제품 사용으로 인한 몬테칼로 전산모사 피폭선량 평가체계 개발)

  • Go, Ho-Jung;Noh, Siwan;Lee, Jae-Ho;Yeom, Yeon-Soo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Radiation exposure to humans can be caused by the gamma rays emitted from natural radioactive elements(such as uranium, thorium and potassium and any of their decay products) of Naturally Occurring Radioactive Materials(NORM) or Technologically Enhanced Naturally Occurring Radioactive Materials(TENORM) added consumer products. In this study, assume that activity of radioactive elements is $^{238}U$, $^{235}U$, $^{232}Th$ $1Bq{\cdot}g^{-1}$, $^{40}K$ $10Bq{\cdot}g^{-1}$ and the gamma rays emitted from these natural radioactive elements radioactive equilibrium state. In this study, reflected End-User circumstances and evaluated annual exposure dose for products based on ICRP reference voxel phantoms and ICRP Recommendation 103 using the Monte Carlo Method. The consumer products classified according to the adhere to the skin(bracelet, necklace, belt-wrist, belt-ankle, belt-knee, moxa stone) or not(gypsum board, anion wallpaper, anion paint), and Geometric Modeling was reflected in Republic of Korea "Residential Living Trend-distributions and Design Guidelines For Common Types of Household.", was designed the Room model($3m{\times}4m{\times}2.8m$, a closed room, conservatively) and the ICRP reference phantom's 3D segmentation and modeling. The end-user's usage time assume that "Development and Application of Korean Exposure Factors." or conservatively 24 hours; in case of unknown. In this study, the results of the effective dose were 0.00003 ~ 0.47636 mSv per year and were confirmed the meaning of necessary for geometric modeling to ICRP reference phantoms through the equivalent dose rate of belt products.