• Title/Summary/Keyword: 방사선학적 평가

Search Result 772, Processing Time 0.043 seconds

RADIOLOGIC ASSESSMENT OF BONE HEALING BY FRACTAL ANALYSIS AFTER THE TREATMENT OF JAW BONE CYST BY DECOMPRESSION (프랙탈 분석을 통한 악골 내 낭종의 감압술 후 골 치유에 대한 방사선학적 평가)

  • Baek, Jin-Woo;Seok, Min;Lee, Eui-Suk;Jang, Hyun-Seok;Rim, Jae-Suk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.494-498
    • /
    • 2007
  • Purpose: This study was done to know the usefulness of fractal analysis when evaluating the radiologic changes after decompression on jaw bone cystic lesions using fractal analysis. Materials and methods: 30cases of cystic lesions were followed up after decompression. Panoramic image was used to observe radiologic changes around the cystic lesion. The part of the panoramic image which showed radiologic change was defined as region of interest(ROI); The fractal dimension of the ROI was calculated using box-counting method. Results: Using sign-rank test, there was a statistically significant difference in fractal dimensions after decompression therapy(P<0.0001). The fractal dimensions statistically increased after decompression(the median of D:0.12). Conclusions: The ROI after decompression showed higher fractal dimensions which offer the objective proof of the bone healing around cystic lesions after decompression treatment.

Development of the Decommissioning Database System to Manage and Assess Data front Decommissioning Activities of Korea Research Reactor 1 & 2 (연구로 1, 2호기 해체활동에 대한 자료 관리 및 평가를 위한 데이터베이스 시스템 개발)

  • 정관성;이동규;박희성;이근우
    • Journal of Energy Engineering
    • /
    • v.13 no.3
    • /
    • pp.191-198
    • /
    • 2004
  • Korea Research Reactor (KRR) 1 & 2 has shut down and through preparatory activities, its decommissioning activities are underway. As its decommissioning activities have been done over several years, its relevant data have been spreaded with various type and media all over the discrete place and inadvertently managed. As s result, managing and assessing data of KRR 1 & 2 has been difficult and complex and its data cannot be evaluated. By developing the decommissioning database system of KRR 1 & 2, the data of decommissioning activities fan be correctly evaluated, being systematically managed and objectively assessed. Finally, the decommissioning project of KRR 1 & 2 have come to more effectively accomplished.

3-D Conformal Radiotherapy for CNS Using CT Simulation (입체조준장치를 이용한 중추신경계의 방사선 입체조형치료 계획)

  • 추성실;조광환;이창걸
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.90-98
    • /
    • 2003
  • Purpose : A new virtual simulation technique for craniospinal irradiation (CSI) that uses a CT-simulator was developed to improve the accuracy of field and shielding placement as well as patient positioning. Materials and Methods : A CT simulator (CT-SIM) and a 3-D conformal radiation treatment planning system (3D-CRT) were used to develop CSI. The head and neck were immobilized with a thermoplastic mask while the rest of the body was immobilized with a Vac-Loc. A volumetric image was then obtained with the CT simulator. In order to improve the reproducibility of the setup, datum lines and points were marked on the head and body. Virtual fluoroscopy was performed with the removal of visual obstacles, such as the treatment table or immobilization devices. After virtual simulation, the treatment isocenters of each field were marked on the body and on the immobilization devices at the conventional simulation room. Each treatment fields was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR) and digitally composited radiography (DCR) images from virtual simulation. Port verification films from the first treatment were also compared with the DRR/DCR images for geometric verification. Results : We successfully performed virtual simulations on 11 CSI patients by CT-SIM. It took less than 20 minutes to affix the immobilization devices and to obtain the volumetric images of the entire body. In the absence of the patient, virtual simulation of all fields took 20 min. The DRRs were in agreement with simulation films to within 5 mm. This not only reducee inconveniences to the patients, but also eliminated position-shift variables attendant during the long conventional simulation process. In addition, by obtaining CT volumetric image, critical organs, such as the eyes and the spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. Differences between the DRRs and the portal films were less than 3 m in the vertebral contour. Conclusion : Our analysis showed that CT simulation of craniospinal fields was accurate. In addition, CT simulation reduced the duration of the patient's immobility. During the planning process. This technique can improve accuracy in field placement and shielding by using three-dimensional CT-aided localization of critical and target structures. Overall, it has improved staff efficiency and resource utilization by standard protocol for craniospinal irradiation.

  • PDF

Image Registration for PET/CT and CT Images with Particle Swarm Optimization (Particle Swarm Optimization을 이용한 PET/CT와 CT영상의 정합)

  • Lee, Hak-Jae;Kim, Yong-Kwon;Lee, Ki-Sung;Moon, Guk-Hyun;Joo, Sung-Kwan;Kim, Kyeong-Min;Cheon, Gi-Jeong;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.195-203
    • /
    • 2009
  • Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  • PDF

COMPARISON OF TRANSMAXILLARY AND TRANSCRANIAL PROJECTION IN THE EVALUATION OF OSTEOPHYTES Of MANDIBULAR CONDYLES (하악과두의 골증식체 평가에 있어서 transmaxillary 촬영법과 transcranial 촬영법의 비교)

  • Kim Tae Gyun;Kim Chin Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.19 no.1
    • /
    • pp.123-136
    • /
    • 1989
  • The purpose of this study was to decide the diagnostic value of transmaxillary and transcranial projection in the evaluation of mandibular condyles. Five dry skulls with intact anatomic structure were selected for this study and the artificial osteophytes were attached to 9 different are as of the mandibular condyle. Ninety transcranial and forty-five transmaxillary radiographs were taken and then the radiographs were evaluated three times. The results were as follows; In transcranial radiographs, superocentral osteophyte was easily observed in closing state than in opening state (p<0.05). But there were no significant differences in other locations (p>0.05). The osteophytes on the medial and central portion easily observed at the transmaxillary projection than transcranial projection (p<0.05), but there was no significant difference on the lateral portion (p>0.05). The osteophytes on the superior (p<0.01) and posterior (p<0.01.) portion were easily observed at the transmaxillary projection than transcranial projection, but there was no significant difference on the anterior portion (p >0.05). The more laterally located osteophytes (p<0.01) at the transcranial projections were easily observed. The more posteriorly located osteophytes (p<0.05) at the transmaxillary projections were easily observed.

  • PDF

A Study on Variation Types in Celiac Axis and Superior Mesenteric Artery using 3D Volume Rendering of MDCT (MDCT의 3차원 볼륨렌더링을 이용한 복강축과 위창자간막동맥의 변위 형태에 관한연구)

  • Lee, Jeong-Keun;Jang, Young-Ill;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • The aim of this study was to evaluate the variation which based on Celiac axis and SMA using by CT volume rendering images. 613 patients underwent abdominal CTA, there were 552 patients (99.05%, TypeI, II) with normal anatomical form and 61 (9.95%, Type III~XII) with variation. TypeI was 339(55.31%), Type II was 213 (34.74%), Type III was 18 (2.93%), Type IV was 12 patients (1.95%), Type V was 11 patient (1.79%), Type VI was 9 patients (1.46%), Type VII was 6 patients (0.97%), Type VIII was 1 patient (0.16%), Type IX was 1 patient (0.16%), Type X was 1 patient (0.16%), Type XI was 1 patient (0.16%), and Type XII was 1 patient (0.16%) into totally new types of variation. In conclusion, we could found 9 new types of variation by classifying based on celiac axis and superior mesenteric artery. These results were considered to be an important opportunity for a new vessel map.

Analysis of the Radiation Therapy Outcomes and Prognostic Factors of Thymoma (흉선종에 대한 방사선치료 성적 및 예후인자분석)

  • Lee, Seok-Ho;Lee, Kyu-Chan;Choi, Jin-Ho;Lee, Jae-Ik;Sym, Sun-Jin;Cho, Eun-Kyung
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Purpose: This retrospective study was performed to evaluate the efficacy of radiation therapy (RT) and to investigate the prognostic factors for thymoma when treated with RT. Materials and Methods: We analyzed 21 patients with thymoma and also received RT from March 2002 to January 2008. The median follow-up time was 37 months (range, 3 to 89 months). The median patient age was 57 years (range, 24 to 77 years) and the gender ratio of males to females was 4:3. Of the 21 patients, complete resections (trans-sternal thymectomy) and R2 resections were performed in 14 and 1 patient, respectively. A biopsy was performed in 6 patients (28.7%). The WHO cell types in the 21 patients were as follows: 1 patient (4.8%) had type A, 10 patients (47.6%) had type B1-3, and 10 patients (47.6%) had type C. Based on Masaoka staging, 10 patients (47.6%) were stage II, 7 patients (33.3%) were stage III, and 4 patients (19.1%) were stage IVa. Three-dimensional RT was adminstered to the tumor volume (planned target volume), including the anterior mediastinum and the residual disease. The total RT dose ranged from 52.0 to 70.2 Gy (median dose, 54 Gy). Consistent with the WHO criteria, the response rate was only analyzed for the 6 patients who received a biopsy only. The prognostic factors analyzed for an estimate of survival included age, gender, tumor size, tumor pathology, Masaoka stage, the possibility of treatment by performing surgery, the presence of myasthenia gravis, and RT dose. Results: The 3-year overall survival rate (OS) and the progression free survival rate (PFS) were 80.7% and 78.2%, respectively. Among the 10 patients with WHO cell type C, 3 of 4 patients (75%) who underwent a complete resection and 3 of 6 patients (50%) who underwent a biopsy survived. Distant metastasis developed in 4 patients (19.1%). The overall response rate in the 6 patients who received biopsy only were as follows: partial remission in 4 patients (66.7%), stable disease in 1 patient (16.6%), and progressive disease in 1 patient (16.6%). Acute RTOG radiation pneumonitis occurred in 1 patient (4.8%), grade 2 occurred in 2 patients (9.5%), grade 3 occurred in 1 patient (4.8%), and grade 4 occurred in 1 patient (4.8%). A univariate analysis revealed that the significant prognostic factors for OS were age (${\geq}60$, 58.3%; <60, 100%; p=0.0194), pathology (WHO cell type A-B3, 100%; C, 58.3%; p=0.0194) and, whether the patient underwent surgery (yes, 93.3%; no, 50%; p=0.0096). Conclusion: For the 15 patients who received surgery, there was no local failure within the radiation field. In patients with WHO cell type C, surgical procedures could have resulted in a more favorable outcome than biopsy alone. We report here our clinical experience in 21 patients with thymoma who were treated by radiation therapy.

A Retrospective Study of Critical Success Factors in Regenerative Endodontic Treatment (재생근관치료의 성공에 영향을 미치는 결정 요인에 대한 후향적 연구)

  • Jeong, Hwakyong;Lee, Nanyoung;Lee, Sangho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.47-55
    • /
    • 2017
  • This study evaluated critical factors influencing the success of regenerative endodontic treatment for necrotic immature permanent teeth. The study enrolled patients who had regenerative endodontic treatment in a necrotic immature permanent tooth through 1-year follow-up. Possible explanatory variables related to the success rates for 46 teeth were age, gender, dental stage at the initial appointment, etiology, treatment information, and clinical and radiographic outcomes. The dental stage at the time of regenerative endodontic treatment did not influence the success rate. The success rate was significantly related to the etiology of the necrotic immature tooth. The success rate according to etiology decreased in the following order: dens evaginatus, caries, and trauma. There was also a significant difference according to the type of antimicrobial. The success rate was influenced by appropriate disinfection of the root canal system, provision of a scaffold, and coronal sealing. Above all, careful case selection is necessary for treating a necrotic immature permanent tooth, especially in cases of trauma.

Local ridge augmentation using a composite of bone substitute and collagen membrane at peri-implant dehiscence defects: a clinical, radiographic and histological analyses. (성견에서 차단막/골이식재 복합체를 이용한 임플란트 주위 골유도재생 효과: 임상적, 방사선학적, 조직학적 평가)

  • Song, Young Woo;Yoon, So-Ra;Cha, Jae-Kook;Lee, Jung-Seok;Choi, Seong-Ho;Jung, Ui-Won
    • The Journal of the Korean dental association
    • /
    • v.55 no.10
    • /
    • pp.676-687
    • /
    • 2017
  • Objectives : The aim of this study was to evaluate the effects of a composite of bone substitute and collagen barrier membrane (bone patch) for local ridge augmentation at peri-implant dehiscence defects on the clinical efficacy and positional stability in dogs. Materials and methods : Implant placement and ridge augmentation procedure were performed at surgically created peri-implant dehiscence defects in canine mandible (n=6). Four treatment modalities were randomly applied: i) bone patch group, ii) Guided bone regeneration (GBR) without pin fixation group (bone graft and collagen membrane), iii) GBR with pin fixation group, and iv) negative control group. After 12 weeks, clinical, micro-CT and histological analyses were performed. Results : Histologic analysis showed that bone patch group had similar results to GBR group and GBR with fixation group in terms of new bone formation. Micro-CT analysis revealed similar results to histologic analysis in terms of total volume maintenance. Operating time was shorter in bone patch group compared to GBR group and GBR with fixation groups. Conclusions : GBR using bone patch could simplify the ridge augmentation procedure with reduced operating time and equivalent biological performance compared to the conventional procedure.

  • PDF

Geometrical QC/QA for Medical Linear Accelerator using Electronic Portal Imaging Devices(EPID) (전자포탈영상장치 (EPID)를 이용한 선형가속기의 기하학적인 QC/QA)

  • Lee, Seok;Lee, Byung-Yong;Cho, Jung-Gil;Kwon, Soo-Il;Jung, Won-Kyu;Kim, Jong-Hoon
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.59-65
    • /
    • 1997
  • We have designed the software for geometrical QC/QA for medical linear accelerator using electronic portal imaging devices (EPID). The radiation-light field congruence, the collimator rotation axis, and the gantry rotation axis could be estimated with this software. Precision of the system is within 1mm. The collimator and the gantry rotation axis could be measured by superpositioning the images from 4 different collimator (or gantry) angles. The EPID system and the analysis software which was developed in this study make it possible that the quantitative and the objective geometrical QC/QA of the linear accelerator.

  • PDF