• Title/Summary/Keyword: 방사선학적 평가

Search Result 772, Processing Time 0.021 seconds

Comparison the reference ion chamber in using the radioactive check source and field ion chamber for output dose for Co-60 source of remote afterloading system (시험선원을 이용한 기준 전리함의 감도변화와 임상필드전리함의 성능 안정성 비교)

  • 최태진
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.141-146
    • /
    • 2001
  • It is well known that assurance of the radiation therapy needs for an accuracy of $\pm$ 5 % in the delivery of an absorbed dose to target volume. Therefore, the dose evaluation of brachytherapy source and/or linear accelerate beam must be a stability with accuracy. In an advanced country, they recommended to use the radioactive check source for reference air ionization chamber for a stable response of radiation field chamber. In this experiments, the radioactive source Sr-90 and PR-05 air ionization chamber were used for standard source and reference ion chamber. The response of reference ion chamber showed as an 1.000$\pm$ 0.010 uncertainty for 10 years long and the evaliuation f dose discrepancy of clinical field ion chamber showed as 0.997 $\pm$0.011 in a $^{60}$ Co brachytherapy soruce. In our experiments, we can assuarance the long halflife standard source is reliable to preserve the calibration factor of reference chamber in stability.

  • PDF

Midterm Results of the Modified Kidner Procedure for the Symptomatic Accessory Navicular in Athletes (운동 선수에서 발생한 동통성 부주상골의 변형 Kidner 술식의 중기 결과)

  • Lee, Kyung Tai;Kim, Ki Chun;Young, Ki Won;Park, Young Uk
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.2
    • /
    • pp.82-86
    • /
    • 2012
  • Purpose: The purpose of this study was retrospectively to evaluate the results of the modified Kidner procedure for symptomatic accessory navicular in athletes. Materials and Methods: Between July 1999 and December 2004, 26 feet in 22 patients with symptomatic accessory navicular who had underwent modified Kidner procedure were available for clinical follow-up, and 12 cases in 9 patients were available for clinical and radiological follow-up with a minimum follow-up of 5 years were included in this study. All those patients had symptomatic accessory navicular bone who underwent modified Kidner procedure. American Orthopaedic Foot and Ankle Society (AOFAS) midfoot score, Visual Analogue Scale (VAS), and satisfaction rate were investigated. Talo-first metatarsal (T-MT1) angle, talo-calcaneal (TC) angle, and calcaneal pitch (CP) angle were measured in standing lateral radiograms. Results: AOFAS score was improved from $40.8{\pm}7.5$ (32~57) preoperatively to $88.7{\pm}8.0$ (72~100) postoperatively, and the difference was significant (p<0.01). VAS was improved from $7.0{\pm}0.9$ (5~9) preoperatively to $1.8{\pm}0.8$ (1~4) postoperatively, and the difference was significant (p<0.01). At the lastest follow up, 11 feet were very satisfied, 11 feet satisfied, and 4 feet unsatisfied (a satisfaction rate 85.0%). No significant difference was observed for T-MT1 angle (p=0.67), TC angle (p=0.93), and CP angle (p=0.49). Conclusion: Modified Kidner procedure for the symptomatic accessory navicular showed satisfactory results and is appeared to be one of the useful treatments.

  • PDF

The Surgical Treatment of Chronic Avulsion Fracture of the Anterior Cruciate Ligament (진구성 전방 십자 인대 견열 골절의 수술적 치료)

  • Song Eun-Kyoo;Seol Jong-Yoon;Choi Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the clinical and radiological results after treatment of old ACL(anterior cruciate ligament) avulsion fracture of tibia. Materials and Method : 11 cases who were followed up at least 2 years after treatment in chronic ACL avulsion fracture of tibia were included in this study. The average age of patients was 26(9-66) years and the mean period of follow up was 53(24-131) months. After evaluation of the lesion and treatment of associated lesion under arthroscope, open reduction and internal fixation or fragment removal was performed. Pull-out suture was performed in 8 cases, screw fixation in 2 cases. Results : The Lysholm knee score was 64.3 in average preoperatively and improved to 96.2 average at follow up. On the Lachman test, there were mild(+) instabilities in 7 cases, moderate(++) in 4 cases. On the postoperative Lachman test, there were no instabilities in 9 cases, mild(+) instabilities in only 2 cases. According to Meyers and Mckeever's evaluation protocol, 9 cases $(81.8\%)$ were excellent, 2 case $(18.2\%)$, good. On preoperative instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 201b was 7.8(10-4) min in average and 2.1(6-0) mm in average at follow-up. Conclusion : In chronic ACL avulsion fracture, it is thought that combination of arthroscopic evaluation of associated injury and open reduction and fixation and fragment removal can bring about satisfactory results.

  • PDF

Quantitative Evaluation of CT Artifact Elimination with various Cut-off Frequency of Hann Filter (Hann 필터의 Cut-off 주파수 변화에 따른 CT 영상의 Artifact 제거효과에 대한 정량적 평가)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.5-9
    • /
    • 2008
  • In the computerized tomography(CT), various filters are using in the reconstruction algorithm to reduce or eliminate the artifacts which are intrinsically induced by the imperfection of mathematical methods for reconstruction, lack of real informations about anatomic structures in the projection image, errors in data acquisition and so on. Hann filter was used to evaluate the filter effects on the elimination of reconstruction artifact in the CT image. The quantitative study was done by changing cut-off frequency of Hann filter from 0.1 to 0.9 with frequency increasement by 0.2. NPS analysis was fulfilled for the quantitative evaluation of filter effect.

  • PDF

Aspiration and Ingestion of Foreign Bodies in Dental Practice (치과진료 중 발생한 이물질의 섭취와 흡인)

  • Heo, Narang;Lee, Kwanghee;An, Soyoun;Song, Jihyun;Shin, Gayoung;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.1
    • /
    • pp.69-74
    • /
    • 2015
  • Despite preventative efforts, aspiration and ingestion of foreign bodies during clinical dental procedures occasionally occur. Careful clinical and radiographic examination and prompt emergency management can prevent potentially serious consequences. In this report, we describe a case of accidental foreign body ingestion and discuss prevention and management of dental instrument aspiration and ingestion.

Radiographic Evaluation of Femoral Tunnel Placement During ACL Reconstruction (전방 십자 인대 재건술시 대퇴 터널의 위치에 대한 방사선학적 평가)

  • Chung, Hyun Kee;Choi, Choong Hyeok;Lee, Joong Hak
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.80-84
    • /
    • 1998
  • The isometric position for the graft is important in the anterior cruciate ligament reconstruction surgery. It is well known that the femoral position is more critical than tibial side. But, there is few deciding method of proper graft position after the anterior cruciate ligament reconstruction surgery. So we planned to evaluate the ideal femoral isometric position with 6 adult cadavaric femurs and exact radiographs. After the insertion of femoral interference screw on ideal isometric position, we obtained roentgenograms of true lateral view and 10, 20, 30, 45 degree internal and external rotation views. Then we measured the shortest distance from the posterior cortical margin of lateral femoral condyle to posterior border of interference screw on the radiographs. We also measured true distance between posterior cortical margin of lateral femoral condyle to the posterior margin of femoral tunnel after cutting of distal femur. Based on this study, we could not determine the permissible rotation degree of radiographs. But we concluded that if the distance between posterior cortical margin of lateral femoral condyle and posterior border of interference screw ranges 4.5-6.5mm on the lateral view, the femoral position is considered as a relatively ideal isometric good position.

  • PDF

Radiographic Evaluation of Hip Conformation in the Dogs with Medial Patella Luxation (개에서 내측슬개골 탈구 등급에 따른 고관절 이상과의 상관관계에 대한 방사선학적 평가)

  • Lee, Ki-Ja;Park, Eun-Jeong;Kwon, Young-Hang;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.278-282
    • /
    • 2013
  • This study was performed in 41 dogs with unilateral or bilateral medial patella luxation (MPL) and/or cranial cruciate ligament rupture (CCLR). These dogs were classified into 4 groups according to MPL grading system. Radiographic evaluation was performed for pelvis and stifle joint in the dogs. Norberg, inclination, quadriceps and femoral varus angle were measured and analyzed with MPL grading and the existence of cranial cruciate ligament rupture. The Norberg and inclination angle showed no differences between 4 grading groups and between CCLR and no CCLR groups. However, quadriceps and femoral varus angle were statistically different between grade 1, 2 and grade 3, 4 groups. They also have shown the statistical difference between CCLR and no CCLR group. Further studies for how these parameters affect the prognosis and the results of surgical treatment of MPL should be needed.

Radiographic Evaluation of Canine Hip Joint in Labrador Retrievers as Guide Dog (안내견으로 사용하고 있는 Labrador Retriever 고관절의 방사선학적 평가)

  • Choi Yoon-ju;Chung Dong-hee;Kim Hwan;Yoon Jung-hee
    • Journal of Veterinary Clinics
    • /
    • v.22 no.3
    • /
    • pp.249-252
    • /
    • 2005
  • This study was carried out to assess hip joint in Labrador retrievers. From 1999 to 2004, 131 Labrador retrievers were tested by British Veterinary Association(BVA)/Kennel club(KC) scoring scheme, 66 were tested by $PennHIP^{(R)}$ method. In this study the mean score by BVA/KC scoring scheme was $12.5{\pm}6.6$ and the mean DI was $0.53{\pm}0.14$. It was found that Labrador retrievers of Samsung Guide Dog school have better hip joint condition than that of Labrador retrievers registered in BVA, and have similar mean DI to PennHIP breed mean score. This study suggested that using both BVA/KC scoring scheme and $PennHIP^{(R)}$ method was a specific method which can make the most possible definitive diagnosis, could provide baseline hip information for the hip joint in Labrador retrievers as Guide Dog.

Radiological Evaluation on Dislocation of the Hip with Spastic Cerebral Palsy (경직형 뇌성마비 아동의 고관절 탈구에 대한 방사선학적 평가)

  • Kim, Jeong-Hwan;Kim, Yong-Nam
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.1
    • /
    • pp.9-17
    • /
    • 2004
  • The purpose of this study are to determine the proper radiographic measurements for hip deformity in spastic cerebral palsy patients, and the correlation of hip deformity with neurological involvement, ability of ambulation. Thirty children with cerebral palsy(22 males, 8 females) were evaluated by measurement of the migration index, acetabular index, center edge angle from bilateral hip APs(anterior posterior view). The result are as follows; 1. The incidence of hip dislocation, among the thirty children fifteen children were found to be dislocated, and more significantly high in non-walking group than in walking group(p<0.05) and in quadriplegia than in diplegia(p<0.05). 2. When compared to normal hip and dislocation hip, the migration index was significantly higher(p<0.01) and the center edge angle was lower in the dislocation hip than in the normal hip. 3. Correlation of radiological findings in right and left hip, the migration index and the center edge angle were highly correlated(p<0.01). We recommand regular intervals X-ray study for early diagnosis and management of hip dislocation in spastic cerebral palsy.

  • PDF

ASSESSMENT OF IMPLANT STABILITY AFTER IMMEDIATE LOADING IN DOGS : CLINICAL AND RADIOGRAPHIC STUDY (성견에서 즉시 부하 후 임프란트 안정성 평가 : 임상적, 방사선학적 연구)

  • Lee, Joo-Young;Kim, Su-Gwan;Kim, Sang-Ho;Kim, Wan-Bae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.131-139
    • /
    • 2005
  • The therapeutic goal of implant dentistry is not merely tooth replacement but total oral rehabilitation. Considering dental implants as a treatment option can be provided patients with positive, long-term results. Implant dentistry has gone through many phases over the years. Modern technology and design allows us to predictably place our dental implants often load the implants at the time of placement. The purpose of this study is to evaluate the implant stability after immediate loading in dogs. The control group was performed delay loading and experimental group was immediate loading. Each group was measured periotest value(PTV) to evaluate clinical mobility and performed radiographic examination to evaluate marginal bone loss. Statistically significant difference was not founded in control group between experimental group in PTV(P>0.05) and marginal bone loss(P>0.05). Finally, implant stability after immediate loading was similar to delay loading implant.