• Title/Summary/Keyword: 방사선학적 평가

Search Result 772, Processing Time 0.032 seconds

Mini-T Plate Fixation for Neer Type II Distal Clavicle Fracture (Neer 분류 제 2형 원위부 쇄골 골절의 mini-T형 금속판 고정)

  • Yum, Jae-Kwang;Lee, Sang-Lim;Ra, Ho-Jong
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Purpose: To evaluate and report the clinical and radiological outcomes of open reduction and internal fixation with a mini-T plate for unstable distal clavicle fractures. Materials and Methods: From December 2004 to July 2007, fifteen patients who had a fracture of the distal clavicle (Neer type II fracture) were treated with an open reduction and internal fixation using a mini-T plate. They were followed up for a minimum of one year and the clinical and radiological results were analyzed. Results: The average time to fracture union was 3.1(3~4) months. There were no complications, such as deep infection or fixation loss. The mean ASES score was 97 points (85~100points) at the last follow up period, and 14 patients had a full range of motion of the shoulder. Conclusion: Open reduction and internal fixation with a mini-T plate for unstable distal clavicle fracture is a good surgical method with good clinical and radiological results.

Development of Novalis Quality Assurance Protocol for Radiosurgery (방사선수술을 위한 노발리스 품질관리 프로토콜 개발)

  • Lee, Dong-Joon;Lee, Kyung-Nam;Lee, Suk;Lee, Sang-Hoon;Kim, Dae-Hong
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.99-112
    • /
    • 2010
  • In Republic of Korea, there are many Quality Assurance protocol for general radiation treatment machine such as linac. However, Quality Assurance protocol for radiosurgery treatment system is not ready perfectly. One of the radiation treatment machine for radiosurgery, novalis system needs to suitable Quality Assurance protocol for using it right way during radiation treatment and maintaining suitable accuracy for daily, weekly, monthly and annually periods. Therefore, in this article, we develop Quality Assurance protocol for novalis system. We collected and analysed domestic and foreign novalis Quality Assurance protocol. After that, we selected essential QA items and each tolerance range for developing proper QA protocol, and we made anatomical phantom for execution of selected QA items and evaluation of overall state of QA, and then, we use this measured value as a reference. Quality Assurance items are consisted of Mechanical accuracy QA part and Radiation delivery QA part. Mechanical accuracy QA part is comprised of radiation generation machine part, assistive devices part and multi-leaf collimator part. Radiation delivery QA part is divided into radiation isocenter accuracy and dosimetric evaluation. After that, developed novalis QA tables are made by using these QA items. These novalis QA tables would be used to good standard in order to maintain apt accuracy for radiosurgery in daily, weekly, monthly and annually periods.

An Analysis on the DCGL setting Method of the United States for Demonstrating Nuclear Power Plants Site Release Criteria (국내 원전 부지 해제 기준 준수 입증을 위한 미국의 유도농도기준(DCGL) 설정 방법에 대한 분석)

  • Jeon, Yeo Ryeong;Park, Sang June;Ahn, Seokyoung;Lee, Jong Seh;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • The U.S. NRC establishes a radiological criteria with regard to restricted or unrestricted use of nuclear plant site after decommissioning in NUREG-1757. According to this, a nuclear plant site can be released in a restricted way or unrestricted way only if a licensee demonstrates that the dose criteria is fulfilled after the site decontamination and remediation. In order to prove compliance with the radiological criteria of site release, LTP(License Termination Plan) must include the site release criteria, site characterization, final survey plan with major radionuclides and DCGL(Derived Concentration Guideline Levels), etc. Based on the decommissioning case of Rancho Seco nuclear power plant in the United States, this paper analyzed a method of setting the DCGL that can be applied to Kori NPP Unit 1 which will be permanently disabled in 2017.

Short-term clinical outcome of intentionally replanted posterior molars (의도적 재식술을 시행한 대구치의 단기간의 임상 평가)

  • Choi, Yong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.12-18
    • /
    • 2011
  • Objectives: This retrospective study evaluated the therapeutic effects of the intentional replantation (IR) procedure performed on the maxillary and mandibular molars of 35 patients. Materials and Methods: For the subjects, IR was performed due to difficulties in anatomically accessing the lesions and/or close proximity to the thick cortical bone, inferior alveolar nerve, or maxillary sinus, which rendered the ordinary periradicular surgery impossible. The patients'progress was followed for a year and up to 2 years and 4 months. The success of the procedure was evaluated in terms of clinical and radiographic success (%). Results: The results revealed the following: (a) 1 case (3%) of failed tooth extraction during IR; (b) 2 cases (6%) of extraction due to periodontal diseases and inflammatory root resorption; (c) 3 cases (9%) of normally functioning teeth in the oral cavity with minor mobility and apical root resorption, and; (d) 29 cases (82%) of normally functioning teeth without obvious problems. Conclusions: IR was confirmed to be a reliably repeatable, predictable treatment option for those who cannot receive conventional periradicular surgery because of anatomic limitations or patient factors.

Image Enhancement and Clinical Evaluation in Digital Chest Radiography (디지털 방사선 흉부영상의 영상개선과 임상평가)

  • Kim, Sung-Hyun;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.143-149
    • /
    • 2008
  • The aim of this study is to suggest the method for image enhancement of digital chest radiograph and evaluate clinically the quality of the resultant image. A nonlinear iterative filter was developed in order to reduce quantum noise preserving edge. Dynamic range was adjusted and adaptive image enhancement was performed based on the property of anatomic region and the degree of compatibility with neighboring pixels. The lung fields were enhanced appropriately to visualize effectively vascular tissue, bronchus and lung tissue with the desired mediastinum enhancement. Clinic evaluation was performed by three radiologists with at least 8 years experience. The anatomic regions of 11 in PA and 9 in Lateral were observed carefully in each 100 radiographs according to ITU (International Telecommunication Union) recommendation 500 protocol. The result showed the mean 3.4 between good and adequate. This means that the clinical utility of the image quality is enough. In this study, image enhancement was carried out considering image display device and human perceptual system to prevent the loss of useful anatomic information. In order to increase the diagnostic accuracy in digital radiograph, the continuous study on image enhancement is needed.

  • PDF

Correlations between the Clinical Results and Radiologic Evaluation after Surgical Treatment of Calcaneal Fracture (종골 골절의 수술적 치료 후 방사선학적 평가와 임상적 결과의 상관 관계: 종골 골절의 술 후 방사선학적인 평가)

  • Park, Hyun-Woo;Kim, Yeon-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.2
    • /
    • pp.157-160
    • /
    • 2010
  • Purpose: The purpose of this study is to find out the correlation factors for prognosis of calcaneal fractures. Materials and Methods: 120 cases (feet) of calcaneal fractures, all of them followed up for more than 1 year after surgical procedures, consisted of 101 men (105 feet) and 13 women (15 feet) were reviewed retrospectively. The collected clinical data were as follows : injury mechanism, surgical procedures, time to procedure, time to work and the radiologic data: Bohler angle, heel width, displacement of posterior facet. AOFAS hindfoot score and VAS score were checked. With ANOVA test and multiple regression analysis, the data processed statistically. Results: According Sanders classification, type II was 37 cases (31%), type III 66 cases (55%), and type IV 17 cases (14%). On plane radiography, the Bohler angle improved to average 28.4 degree from 5.6 degree, and the displacement of posterior facet was corrected to average 1.2 mm. AOFAS hindfoot score was checked average 81.7 points postoperatively, and the meaningful difference existed between types of Sanders classification. The Bohler angle represented the outline of the calcaneus had the better correlation with the clinical outcome of calcaneal fractures rather than the anatomical reduction of the posterior facet did. And the width of calcaneus had good correlation with the clinical score. Conclusion: We should also concern about the outline of calcaneus, the width of calcaneus and the Bohler angle representing anatomical reduction, not only the acute reduction of the posterior facet.

Stability of periodontally compromised teeth after splint and non-surgical therapy: two cases followed-up for 1 to 3 years (Splint 및 비외과적 치주치료를 통하여 치주질환에 이환된 치아의 안정화 증례 보고)

  • Kim, Yeon-Tae;Park, Ye-Sol;Kim, Do-Hyung;Jeong, Seong-Nyum;Lee, Jae-Hong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.338-344
    • /
    • 2018
  • This article describes cases of applying non-surgical treatment including scaling and root planing, occlusal adjustment and tooth splinting of periodontally compromised lower anterior incisors Clinical and radiographic evaluations were performed over a 1-3-year period. All clinical parameters and radiographic bone levels improved in both cases. Dramatic regeneration of alveolar bone and lamina dura were observed on radiographic images, and no specific complications occurred during the follow-up period. Within the limitations of this study, these cases demonstrated the possibility of tooth rescue through non-surgical treatment and splinting of periodontally compromised teeth typically considered for extraction.

Coronoid view: A New Radiograph for the Evaluation of the Coronoid Fractures (Coronoid view: 구상돌기 골절을 평가하는 새로운 방사선 촬영법)

  • Song, Joo-Hyoun;Lee, Joo-Yup;Yang, Sung-Cheol;Lee, Han-Yong;Kim, Jong-Ik
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.199-203
    • /
    • 2007
  • Purpose: It is very important to evaluate and fix coronoid process fractures because they are a critical element for a stable, effective elbow function. The lateral view of the elbow joint is used for a radiographic evaluation of the coronoid but an understanding of the fracture pattern is often difficult because of overlap of the radial head and obliquity of the fracture line. We developed the coronoid view, which is a new radiograph for an evaluation of the coronoid process fracture, and discuss its advantages for a postoperative follow-up. Materials and Methods: The coronoid view was designed for an evaluation of the anteromedial fragment of the coronoid process. After the patient sat on his side, the shoulder was abducted $45^{\circ}$ and the elbow was flexed $90^{\circ}$. The X-ray beam was shot perpendicular to the table. Since shoulder was abducted $45^{\circ}$ the fracture line of the coronoid process can be parallel to the X-ray beam, and the radial head can be cleared. Conclusion: The coronoid view can be a good alternative radiograph for an evaluation of a coronoid process fracture because the beam is parallel to the fracture line. The coronoid view can be particularly useful in postoperative patient follow-up where computed tomography is impractical due to metal implants and cost.

Analysis of dosimetric leaf gap variation on dose rate variation for dynamic IMRT (동적 세기조절방사선 치료 시 선량률 변화에 따른 선량학적엽간격 변화 분석)

  • Yang, Myung Sic;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young;Cha, Seok Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.47-55
    • /
    • 2016
  • To evaluate the position accuracy of the MLC. This study analyzed the variations of the dosimetric leaf gap(DLG) and MLC transmission factor to reflect the location of the MLC leaves according to the dose rate variation for dynamic IMRT. We used the 6 MV and 10 MV X-ray beams from linear accelerator with a Millennium 120 MLC system. We measured the variation of DLG and MLC transmission factor at depth of 10 cm for the water phantom by varying the dose rate to 200, 300, 400, 500 and 600 MU/min using the CC13 and FC-65G chambers. For 6 MV X-ray beam, a result of measuring based on a dose rate 400 MU/min by varying the dose rate to 200, 300, 400, 500 and 600 MU/min of the difference rate was respectively -2.59, -1.89, 0.00, -0.58, -2.89%. For 10 MV X-ray beam, the difference rate was respectively ?2.52, -1.69, 0.00, +1.28, -1.98%. The difference rate of MLC transmission factor was in the range of about ${\pm}1%$ of the measured values at the two types of energy and all of the dose rates. This study evaluated the variation of DLG and MLC transmission factor for the dose rate variation for dynamic IMRT. The difference of the MLC transmission factor according to the dose rate variation is negligible, but, the difference of the DLG was found to be large. Therefore, when randomly changing the dose rate dynamic IMRT, it may significantly affect the dose delivered to the tumor. Unless you change the dose rate during dynamic IMRT, it is thought that is to be the more accurate radiation therapy.

  • PDF

Clinical & Radiologic Result of Arthroscopic Bankart Repair Using Knotless Suture Anchor (비매듭 금속 봉합 나사못을 이용한 관절경적 방카트 복원술: 임상적 및 방사선학적 결과의 비교)

  • Oh, Jung-Hwan;Lee, Sang-Hoon;Park, Hong-Keun;Jeon, Suk-Ha;Park, Joon-Suk;Kim, Cheol-Ki;Park, Jin-Young
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.135-141
    • /
    • 2008
  • Purpose: To study the clinical and radiologic results with arthroscopic Bankart repair using knotless metal suture anchor. Materials and Methods: From February 2001 to January 2005, 68 patients, who underwent arthroscopic Bankart repair using knotless suture anchor and were followed up more than 12 months, were evaluated. A mean follow-up period was 34 months. All shoulders were evaluated by Rowe scoring system, range of motion of the shoulder, pain degree of VAS, and This was compared by radiologic findings after surgery. Results: The Rowe scoring system was 43.30 preoperatively, which improved to 95.55 postoperatively. At last follow-up, there was no significance difference between operated shoulder and non-operated shoulder in range of motion. The degree of VAS was measured from 3.3 preoperatively to 0.5 postoperatively. The radiolucent line was shown around suture anchor in 15 shoulders. 2 shoulders of 15 shoulders were reoperated due to redislocation and anchor arthropathy. In Odds ratio, this group (15 patients) had more 2.6 times the subjective instability than other group (53 patients). Conclusion: Arthroscopic Bankart repair using knotless anchor suture is very effective operative technique. But we have to be careful because the radiolucent line around anchor showed up during a follow -up period may indicate poor prognosis.

  • PDF