• Title/Summary/Keyword: 방사선시험

Search Result 436, Processing Time 0.034 seconds

Assessment of Pass Prediction of Radiologist's license on Academic Achievement through Health law Courses of 3rd Year Students in Radiology Department of College(Focus on D Health College) (전문대학교 방사선과 3학년 학생들의 보건법규학업성취도에 관한 방사선사면허 합격예측평가(D 보건 전문대학 중심으로))

  • Jung, Hong-moon;Lee, Joon-il;park, Hyong-hu;won, Do-yeon;Jung, Jae-eun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.533-539
    • /
    • 2018
  • The National Competency Standard (NCS) is being implemented on the basis of a college of higher education. The college offers intensive education by organizing three areas of knowledge, skills and attitudes so that students can perform their full capacity at the same time as graduating in industrial field. Health Department at the College has been training for a variety of medical personnel, including medical technician regions. Especially, the medical technician and medical sector must be licensed to work in the medical field. Therefore, passing the national examination license is a prerequisite for employment. In this study, the health law scores of the third grade students (about 200 students) of the radiology department of D College were analyzed at weekly intervals. The weekly score acquisition can be predict the pattern of student class achievement of individual students. Furthermore, these results can predict the possibility of passing the radiation license examination for individual students.

Genotoxicological Safety on Water-Soluble Fraction of Gamma Irradiated Korean Soybean Fermentation Foods (감마선 조사된 장류 물추출 분획의 유전독성학적 안전성 평가)

  • 육홍선;이은미;김동호;이경행;변명우;이현자;이영남
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.4
    • /
    • pp.297-303
    • /
    • 2000
  • Gamma irradiation at 20 kGy was applied to Kanjang (soy sauce), Doenjang (soybean paste), Kochujang (hot pepper pasts) and Chungkukjang for their possible genotoxicity. The genotoxicity of 20 kGy-irradiated samples was evaluated by Salmonella typhimurium reversion assay. The Salmonella tester strains included TA98, TA100, TA1535 and TA1537 in the absence and presence of an exogenous metabolizing system (59 mix). All samples were negative in the bacterial reversion assay with S. typhimurium TA98, TA100, TA1535 and TA1537. The results indicated that 20 kGy of gamma irradiation on water-soluble fraction of Kanjang, Doenjang, Kochujang and Chungkukjang were not shown mutagenicity.

  • PDF

Proton induced Effects on Commercial Single-mode Optical Fibers (상용 단일모드 광섬유의 양성자 영향)

  • Kim, Jong-yeol;Kim, Young-woong;Ryu, Guk-been;Hwang, Young-gwan;Lee, Min-Woong;Song, Keun-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.623-625
    • /
    • 2022
  • In this paper, the proton induced attenuation characteristics were evaluated for 5 types of commercial single-mode optical fibers using a proton accelerator. The proton beam used in the irradiation test has a high energy of 100 MeV class, and the test was performed by setting the uniformity of the beam irradiation area to 10% or less. According to the type of optical fiber (internal material, impurities), the radiation induced attenuation by the proton irradiation showed a noticeable difference.

  • PDF

Thickness Evaluation of Pipeline Using Density Profile on a Radiograph (방사선투과필름에서 Density Profile을 이용한 배관의 두께 평가)

  • Lee, Sung-Sik;Jang, Byoung-Gyu;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.483-489
    • /
    • 2002
  • The computer simulation has been done for non-insulated and insulated pipes which are vacant or half filled with liquid. The simulation results showed that the density profile on the radiography is continuous and symmetrical around the center of pipe in the case of vacant pipe. On the other hand the density profiles are not symmetrical and depend on geometrical setting for radiography in the case of half filled pipes. Finally, experimental testing on a non-insulated carbon steel pipe with artificial notches of different depth is carried out using Ir-192 and industrial film. Comparing the measured density profile on the radiograph to the calculated one, it has been shown that it is possible to evaluate thickness variation by measuring density profile on a radiograph.

Development of Prototype Electronic Dosimeter using the Silicon PIN Diode Detector (실리콘 PIN 다이오드 검출기를 이용한 전자선량계 개발)

  • Lee, B.J.;Kim, B.H.;Chang, S.Y.;Kim, J.S.
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.197-205
    • /
    • 2000
  • A prototype electronic dosimeter(PED) adopting a silicon PIN diode detector as a radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this PED has been performance-tested by using a reference photon radiation field. As a result in a electronic performance test, radiation signals from a detector were well observed in the signal processing circuit. The radiation detection sensitivity of this PED after several test-irradiations to $^{137}Cs$ gamma radiation source appeared to be 1.85 cps/$Gy{\cdot}h^{-1}$ with 19.3% of the coefficient of variation, which satisfied the performance criteria for the active personnel radiation monitor. Further improvement of the electronic circuit and operating program will enable the PED to be used in personal monitoring purpose.

  • PDF

Application of the Two-Dosimeter Algorithm for Effective Dose Evaluations based on ICRP Publication 103 (ICRP 103 방사선방호 체계 하에서 유효선량 평가를 위한 Two-Dosimeter Algorithm의 적용방안)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.154-159
    • /
    • 2011
  • To evaluate the radiation exposure of workers participating in task where high radiation exposure is expected, two-dosimeter is typically provided radiation workers, one on the chest and the other on the back, at Korean nuclear power plants (NPPs). In a previous study, the NCRP (55:50) algorithm was selected as the optimal two-dosimeter algorithm (TDA) with various field tests and this TDA has been applied to all Korean NPPs since 2006. In 2007, the International Commission on Radiological Protection (ICRP) published the new ICRP recommendation, ICRP 103, which provides the revised weighting factors for both radiation and tissues and the new reference phantom. In this study, the applicability of current NCRP (55:50) algorithm at Korean NPPs for ICRP 103 was analyzed. As a result, it was found that the NCRP (55:50) algorithm is still effective to estimate the effective dose of workers under ICRP 103.

Characteristics Analysis of SiPM for Detection of High Sensitivity of Portable Detectors (휴대용 검출기의 방사선 고감도 검출을 위한 SiPM 특성 분석)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.897-902
    • /
    • 2023
  • The purpose of this paper is to analyze the characteristics of Silicon Photomultiplier (SiPM) for the realization of high-sensitivity radiation detection in portable detectors. Portable X-ray detectors offer the advantage of quickly accessing the patient's location and obtaining real-time images, allowing physicians to perform rapid diagnoses. However, this mobility comes with challenges in achieving accurate radiation detection. In existing detectors, SiPM is used for a simple purpose of detecting X-ray triggers. To verify the feasibility of high-sensitivity X-ray detection through SiPM, seven types of SiPM sensors were compared and selected, and their characteristics were analyzed. The SiPM used in the final test demonstrated the ability to distinguish signals at the ultra-low radiation level of 10 nGy, and it was observed that the slope of the signal rise curve varies with the X-ray tube voltage. Utilizing the characteristics of SiPM, which exhibits changes in signal level and duration with X-ray dose, it appears possible to achieve high-sensitivity measurements for X-ray detection.

Genotoxicological and Acute Toxicological Safeties of Gamma Irradiated Beef (감마선조사 쇠고기의 유전독성 및 급성독성학적 안전성평가)

  • Kang, Il-Jun;Kwak, Hee-Jin;Lee, Byung-Hoon;Kim, Kwang-Hoon;Byun, Myung-Woo;Yook, Hong-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.775-780
    • /
    • 1998
  • Gamma irradiation at 5 kGy was applied to beefs for evaluation of their possible genotoxicity and acute oral toxicity. The genotoxicity of 5 kGy irradiated beef was evaluated by Salmonella typhimurium reversion assay and in vivo micronucleus assay using mouse bone marrow cells. The results were negative in the bacterial reversion assay with S. typhimurium TA98, TA100, TA1535, TA1537. Clastogenic effects were not shown in vivo mouse micronucleus assay at 5 kGy dose tested. In an acute toxicity test, 5 kGy-irradiated beef was administrated orally at a dose level of 313 to 5,000 mg/kg, and then number of deaths, clinical signs, body weights, and pathological examinations were examined daily for 14 days post-administration. The results indicate that 5 kGy irradiated beef did not show any toxic effect on mice and oral $LD_{50}$ value was over 5,000 mg/kg on ICR mice.

  • PDF

Protective Effect of a Herbal Preparation (HemoHIM) on the Self-Renewal Tissues and Immune System against γ-Irradiation (방사선에 대한 생약복합조성물(HemoHIM)의 재생조직 및 면역계 방호 · 회복촉진 효과)

  • Jo, Sung-Kee;Park, Hae-Ran;Jung, Uhee;Oh, Heon;Kim, Sung-Ho;Yee, Sung-Tae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.6
    • /
    • pp.805-813
    • /
    • 2005
  • In our previous study, a novel herb mixture (HIM-I) of Angelim gigas radix, Cnidium officinale rhizoma, and Paeonia japonica radix was developed to protect the intestinal and immune systems and promote its recovery against radiation damage. In this study, a new herbal preparation (HemoHIM) with the high immune modulating activity was developed from HIM-I. HIM-I was fractionated into ethanol fraction (HIM-I-E) and polysaccharide fraction (HIM-I-P). And HemoHIM was prepared by adding HIM-I-P to HIM-I. The protective activities against $\gamma$ -irradiation were compared among HemoHIM, HIM-I and the fractions. HemoHIM and HIM-I significantly decreased the radiation-induced DNA damage in vitro, and scavenged hydroxyl radicals in a dose-dependent manner. HemoHIM showed similar activity to HIM-I. In vitro proliferation assay with mouse lymphocytes and bone marrow cells showed that HIM-I-P was remarkably higher than HIM-I and HIM-I-E in cell proliferating activity. HemoHIM showed higher activity than HIM-I and this might be associated with the higher polysaccharide content. The in vivo protective effects of HemoHIM and HIM-I were investigated in $\gamma$-irradiated mice. HemoHIM increased the surviving intestinal crypts to a similar extent compared with HIM-I. In contrast, HemoHIM appeared to be more effective than HIM-I in endogenous spleen colony formation assay. The recovery of white blood cells and lymphocytes in irradiated mice were significantly enhanced by the administration of HemoHIM. Also HemoHIM administration prolonged the survival of irradiated mice. These results showed that the novel herbal preparation, HemoHIM, effectively protected the self-renewal tissues and immune system, and promoted the survival of irradiated mice. Moreover, in comparison with HIM-I, HemoHIM maintained similar activity in the reduction of oxidative damage of self-renewal tissue but exhibited the higher activity in protection and proliferation of immune and hematopoietic cells. These results suggested that HemoHIM might be more effective than HIM-I in immune modulation as well as radioprotection.

Pulsed Photostimulated Luminescence (PPSL) of Irradiated Importation Sesame and Perilla Seeds (방사선 조사된 수입 참깨, 들깨의 광여기 발광)

  • Yi, Sang-Duk;Woo, Si-Ho;Yang, Jae-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.173-177
    • /
    • 2001
  • A study was carried out to establish a detection method for imported sesame and perilla seeds using pulsed photostimulated luminescence (PPSL) whether they have been irradiated or not. Samples were packed in polyethylene bags and irradiated at 1, 5, and 10 kGy with a dose rate of 10 kGy/h. The whole sample of sesame and perilla and the minerals separated from seeds were introduced in the sample chamber and measured PPSL photon counts for 60 and 120 s. The PPSL photon counts of samples increased with increasing irradiation dose and showed a higher correlation coefficients in separated minerals than in sesame and perilla seeds themselves. These results suggest that imported sesame and perilla seeds be possibly detected by both their whole sample and separated minerals by PPSL measurements.

  • PDF