• Title/Summary/Keyword: 방사선멸균

Search Result 54, Processing Time 0.016 seconds

Regenerative Endodontic Treatment of Infected Immature Permanent Teeth with Dens Invaginatus : A Report of Two Cases (치내치를 동반한 감염된 미성숙 영구치의 재생형 근관치료)

  • Shin, Gayoung;Lee, Kwanghee;An, Soyoun;Song, Jihyun;Heo, Narang;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.2
    • /
    • pp.188-196
    • /
    • 2015
  • Endodontic management of an immature permanent tooth with dens invaginatus poses a challenge to efficient treatment planning for the clinicians. Because it is difficult to shape, disinfect, and seal the canal space effectively, teeth with complex root canal structures often require particularly extensive and thorough treatment approaches. The purpose of this case report was to share clinical insight from the results of short-term follow-ups after regenerative endodontic treatment with a dens invaginatus. Two immature maxillary lateral incisors with Oehlers type I and III dens invaginatus and infected necrotic pulp were treated using regenerative endodontic procedures. For the type III dens invaginatus case, an unusual approach toward redesigning the complex internal structure was taken, in order to have sufficient infection control and sealing. Cone-beam computed tomography (CBCT) and a surgical operating microscope were used to aid visualization and treatment. As a result, regenerative endodontic treatment appears to be effective for managing immature permanent teeth with complex dens invaginatus, and can lead not only to clinical and radiographic resolution, but also increased thickness of the dentinal walls.

Practice method and performance according to clinical practice contents of dental hygiene student (치위생과 학생의 임상실습내용에 따른 실습방법 및 수행 정도)

  • Shin, Myong-Suk;Kim, Chang-Hee;Ahn, Eun-Suk;Hwang, Ji-Min
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.2
    • /
    • pp.123-138
    • /
    • 2019
  • The clinical institution of some dental hygiene students and the degree of practice and performance according to the practice contents are identified, so as to develop clinical practice guidelines and to improve the education of universities and practical institutions. From November 2016 to March 2017, the questionnaire was prepared by self-inclusion after explaining the purpose of research and how to prepare questionnaire to some dental hygiene students. This material has been analyzed using PASW Statistics 18.0. As for the clinical practice content items of basic care and infection control, the frequency of "execution" among practice methods was high, and the distribution rate was high in oral evil face radiation, preventive dentistry, prosthesis, periodontology, orthodontics, and oral internal medicine. The conservation department has conducted various practical methods such as "executing," "observing" and "preparing." Oral surgery showed similar distribution rates, such as "observation," "preparation," and "execution" in the "preparation and cooperation of the feet." In pediatric dentistry, "observation" was the most common practice, and among them, "observation," "preparation," and "execution" were performed in "preparation and cooperation for infantile development." In addition, students with more experience in clinical practice showed statistically significant differences in basic care, oral hygiene, preventative dentistry, conservation, dental dentistry, oral surgery, orthodontics, and oral internal medicine(p<0.05). Most clinical practice shows that it is more observable than performed.It is expected that the goal of clear clinical practice content should be set by grade or number of clinical practice experiences, as well as the practice method that can be performed by the trainees.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF